Search NASA⌕ Search

SEARCH · Search NASA

Results for “FARMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Fast All-Sky Radiation Model for Solar Applications with Narrowband Irradiances on Tilted Surfaces (FARMS-NIT): Part II. The Cloudy-Sky Model

The Fast All-sky Radiation Model for Solar applications with Narrowband Irradiances on Tilted surfaces (FARMSNIT) reported in Part I of this study is enhanced to include the requirements for cloudy-sky conditions. Surface radiances in 2002 narrow-wavelength bands from 0.28 to 4.0 μm are analytically computed by solving the radiative transfer equation for five independent photon paths accounting for clear-sky absorption, Rayleigh scattering, and cloud absorption and scattering. The Simple Model of the Atmospheric Radiative Transfer of Sunshine (SMARTS) is used to provide the optical thickness of the clear-sky atmosphere. Unlike Part I, which approximates the computation of aerosol scattering using the single-scattering phase function, the cloud transmittance and reflectance are efficiently retrieved from a comprehensive look-up table pre-computed by a 32-stream DIScrete Ordinates Radiative Transfer (DISORT) model for possible cloud conditions as well as solar and viewing geometries. A resolution analysis is performed to assess the optimal balance between the computational efficiency and accuracy in the development of the look-up table. Model simulations by DISORT and TMYSPEC are used to evaluate the performance of FARMS-NIT under cloudy-sky conditions. Compared to DISORT, FARMS-NIT yields 2–3% uncertainties on average, but it substantially reduces the computational time because of the independent computation of cloud properties and the implementation of the look-up table. In contrast to TMYSPEC, which uses successive steps to empirically compute plane-of-array (POA) irradiances and spectral irradiances, FARMS-NIT directly solves spectral radiances from the radiative transfer equation, which profoundly increases the accuracy in surface irradiances, especially over inclined photovoltaics (PV) panels.

Xie, Yu↗

Farming the Future: An Approach to Precision Agriculture through UAS-based Thermal Scanners

Food waste is a global issue, and it is extremely prevalent in the United States (U.S.) where one-third of the food produced goes to waste. The most common item found in landfills is food waste, which is why it is one of the most significant contributors to global warming with 8%. These negative environmental impacts also return to affect agriculture, as global warming changes climate patterns and adversely affects farming practices. In addition, the resources that were used to grow the produce are also wasted, including money, water, and time. To tackle this problem at its roots, this paper includes a design of an unmanned thermal drone that can be a farmer’s third eye. This drone will scan over farms and provide data to the farmers about the health, ripeness, and moisture content of their crops through mounted thermal cameras and artificial intelligence. The information provided via these drones will help farmers to make more informed decisions about their crops, decreasing the chances that the crops will go bad in the field. These drones will be one of the first steps in preventing food waste, which will, in turn, help to reduce global emissions that result from farming.

UAS supported agriculture↗

Characterization and Potential Remediation Approaches for Vadose Zone Contamination at Hanford 241-SX Tank Farm

Unplanned releases of radioactive and hazardous wastes have occurred at the 241-SX Tank Farm on the U.S. Department of Energy Hanford Site in southeast Washington State. Interim and long-term mitigation efforts are currently under evaluation for 241-SX Tank Farm. Two contiguous interim surface barriers have been designed for deployment at 241-SX Tank Farm to reduce future moisture infiltration; however, construction of the surface barriers has been deferred to allow testing of alternative technologies for soil moisture reduction and possibly contaminant source term reduction. Previous tests performed by other organizations at the Hanford Site have demonstrated that: vadose zone desiccation using large diameter (greater than 4 inch) boreholes is feasible; under certain circumstances, mobile contaminants may be removed in addition to water vapor; and small diameter (approximately 2 inch) boreholes (such as those placed by the direct push hydraulic hammer) can be used to perform vapor extractions. Evaluation of the previous work combined with laboratory test results have led to the design of a field proof-of-principle test to remove water and possibly mobile contaminants at greater depths, using small boreholes placed with the direct push unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distributed Wind Case Study: Cross Island Farms, Wellesley Island, New York

Installing a small wind turbine can sometimes be challenging due to economics, zoning issues, public perception, and other barriers. Persistence and innovation, however, can result in a successful installation. Dani Baker and David Belding own Cross Island Farms, a 102-acre certified organic farm on Wellesley Island in northern New York. In 2009, they took their interest in renewable energy to the next level by researching the logistics of a small wind installation on their land to make their farm even more sustainable. Their renewable energy system consists of one 10-kilowatt Bergey Excel wind turbine, a solar array, and a propane-powered generator. This case study describes funding for the project and the installation process.

distributed wind↗

Multi-scale simulations of wind farm performance with complex terrain and weather events

Predicting the response of wind farms to local weather is necessary for optimal design and operation. In this work, simulation and analysis of a frontal passage through a utility scale wind farm is achieved for the first time using a seamless multi-scale modeling approach. A generalized actuator disk (GAD) wind turbine model is used to represent turbine wakes, and results are compared to novel radar observations during the frontal passage. The Weather Research and Forecasting (WRF) model is employed with a nested grid setup that allows for coupling between multi-scale atmospheric conditions and turbine response. Starting with mesoscale forcing, the atmosphere is dynamically downscaled to the region of interest, where the interaction between turbulent flows and individual wind turbines is simulated with the GAD at10 m resolution. Several improvements are made to the GAD model to mimic realistic turbine operation, including a yawing capability and a power output calculation. Ultimately, the model is able to capture both the dynamics of the frontal passage and the turbine response; predictions show good agreement with observed turbine wake structure, velocity deficit, and power output after accounting for a phase shift in the mesoscale forcing. This study demonstrates the utility of the WRF-GAD framework for simulating wind farm performance under complex atmospheric conditions.

17 WIND ENERGY↗

Progress on Optimizing Wind Farms and Rotor Designs Using Adjoints

Modern wind plants are increasingly tasked with multiple performance objectives. In addition to designing plants that maximize power output and minimize the levelized cost of energy (LCOE), the design and operation of wind plants is increasingly influenced by challenges regarding grid integration of variable generation renewables. This places a growing emphasis on making wind plants more controllable and predictable. WindSE is a Reynolds-averaged Navier-Stokes (RANS) model designed around analytical gradient and adjoint methods, with the ability to capture terrain-induced effects, as shown in Figure 1. The recent addition of an unsteady solver with an actuator line method (ALM) and ongoing work to enable massively parallel optimizations gives it a unique niche to explore coupled plant-level controls and design problems. This code is an open source python package built on the FEniCS framework that utilizes fast, parallel PETSc solvers to model fluid flow throughout wind-farm scale domains. Two recent studies performed using WindSE demonstrate the capability to optimize under a wide variety of flow conditions and objective functions. In the first, we present an optimization focused on modifying the layout of a wind farm with a fixed number of turbines for maximum total power output [1]. This study highlights the ability to quickly perform simulations using the steady Navier-Stokes solver combined with rotors represented as actuator disks while also stressing the importance of capturing terrain-induced effects. Gradient-based optimization using the RANS equations is viable due to the inclusion of efficiently computed adjoint derivatives. We interpret the physical results of the optimal layout and also discuss the computational cost of scaling to larger problems. In the second study, we present the capabilities of the unsteady Navier-Stokes solver, where rotor-blade profiles represented by actuator lines are optimized to enhance wake steering effects and overall power production [2]. We quantify the wind plant performance gains obtained from this type of simultaneous control co-design optimization as compared to optimizing the blade design and yaw independently. Figure 2 shows the differences between a baseline two-turbine system and an optimized system where we fine-tune the blade chord profile. Results and challenges from each study are quickly summarized and used to motivate the current development efforts within WindSE. Current and future work is focused on enabling higher-resolution studies with more degrees of freedom through parallelization of both the simulation and optimization algorithms. We present benchmarking results to show that WindSE performs well in both weak- and strong-scaling tests and further demonstrate that the optimizer obtains the same convergence rates in both shared- and distributed-memory environments. Using larger wind farms, we can study deep-array effects within an optimization context, allowing the use of objective functions that have been previously unstudied. As an example, we present ongoing work on a blockage metric which characterizes the loss of available kinetic energy due to wake effects from multiple upstream turbines.

adjoint optimization↗

The American WAKE experimeNt (AWAKEN): Groundbreaking International Field Research Addresses Wind Farm Atmosphere Interactions

To help provide that understanding, the U.S. Department of Energy's (DOE's) Wind Energy Technologies Office (WETO) funds the American WAKE experimeNt (AWAKEN). AWAKEN is an international, multi-institutional wind energy field campaign designed to answer the most pressing science questions about the impacts of wind turbine wake effects. From 2022 to 2024, AWAKEN will gather observational data about the atmosphere around and within operational wind farms, validate wind farm models, and advance understanding of wind farm behavior.

AWAKEN↗

Characterization and Potential Remediation Approaches for Vadose Zone Contamination at Hanford 241-SX Tank Farm - 13235

Unplanned releases of radioactive and hazardous wastes have occurred at the 241-SX Tank Farm on the U.S. Department of Energy Hanford Site in southeast Washington State. Interim and long-term mitigation efforts are currently under evaluation for 241-SX Tank Farm. Two contiguous interim surface barriers have been designed for deployment at 241-SX Tank Farm to reduce future moisture infiltration; however, construction of the surface barriers has been deferred to allow testing of alternative technologies for soil moisture reduction and possibly contaminant source term reduction. Previous tests performed by other organizations at the Hanford Site have demonstrated that: vadose zone desiccation using large diameter (greater than 4 inch) boreholes is feasible; under certain circumstances, mobile contaminants may be removed in addition to water vapor; and small diameter (approximately 2 inch) boreholes (such as those placed by the direct push hydraulic hammer) can be used to perform vapor extractions. Evaluation of the previous work combined with laboratory test results have led to the design of a field proof-of-principle test to remove water and possibly mobile contaminants at greater depths, using small boreholes placed with the direct push unit. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

F-Tank Farm Performance Assessment Updates through the Special Analysis Process at Savannah River Site - 12169

The F-Area Tank Farm (FTF) is owned by the U.S. Department of Energy and operated by Savannah River Remediation, LLC (SRR), Liquid Waste Operations contractor at DOE's Savannah River Site (SRS). The FTF is in the north-central portion of the SRS and occupies approximately 22 acres within F-Area. The FTF is an active radioactive waste storage facility consisting of 22 carbon steel waste tanks and ancillary equipment such as transfer lines, evaporators and pump tanks. An FTF Performance Assessment (PA) was prepared to support the eventual closure of the FTF underground radioactive waste tanks and ancillary equipment. The PA provides the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements identified below for final closure of FTF. The FTank Farm is subject to a state industrial waste water permit and Federal Facility Agreement. Closure documentation will include an F-Tank Farm Closure Plan and tank-specific closure modules utilizing information from the performance assessment. For this reason, the State of South Carolina and the Environmental Protection Agency must be involved in the performance assessment review process. The residual material remaining after tank cleaning is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005. The projected waste tank inventories in the FTF PA provide reasonably bounding FTF inventory projections while taking into account uncertainties in the effectiveness of future tank cleaning technologies. As waste is removed from the FTF waste tanks, the residual contaminants will be sampled and the remaining residual inventory is characterized. In this manner, tank specific data for the tank inventories at closure will be available to supplement the waste tank inventory projections currently used in the FTF PA. For FTF, the new tank specific data will be evaluated through the Special Analysis process. The FTF Special Analyses process will be utilized to evaluate information regarding the final residual waste that will be grouted in place in the FTF Tanks and assess the potential impact the new inventory information has on the FTF PA assumptions and results. The Special Analysis can then be used to inform decisions regarding FTF tank closure documents. The purpose of this paper is to discuss the Special Analysis process and share insights gained while implementing this process. An example of an area of interest in the revision process is balancing continuous improvement versus configuration control of agreed upon methodologies. Other subjects to be covered include: 1) defining the scope of the revisions included in the Special Analysis, 2) determining which PA results should be addressed in the Special Analysis, and 3) deciding whether the Special Analysis should utilize more qualitative or quantitative assessments. For the SRS FTF, an FTF PA has been prepared to provide the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements for final closure of FTF. The FTF Special Analyses process will be utilized to evaluate the impact new information has on the FTF PA assumptions and results. The Special Analysis can then be used to inform decisions regarding FTF tank closure documents. In preparing SAs, it is crucial that the scope of the SA be well defined within the SA, since the specific scope will vary from SA to SA. Since the SAs are essentially addendums to the PA, the SA scope should utilize the PA as the baseline from which the SA scope is defined. The SA needs to focus on evaluating the change associated with the scope, and not let other changes interfere with the ability to perform that evaluation by masking the impact of the change. In preparing the SA, it is also important to let the scope determine whether the Special Analysis should utilize more qualitative or quantitative assessments and also which results from the PA should be addressed in the Special Analysis. These decisions can vary from SA and should not be predetermined. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Farms and Waste Feed Delivery - 12507

The mission of the Department of Energy's Office of River Protection (ORP) is to safely retrieve and treat the 56 million gallons of Hanford's tank waste and close the Tank Farms to protect the Columbia River. Our discussion of the Tank Farms and Waste Feed Delivery will cover progress made to date with Base and Recovery Act funding in reducing the risk posed by tank waste and in preparing for the initiation of waste treatment at Hanford. The millions of gallons of waste are a by-product of decades of plutonium production. After irradiated fuel rods were taken from the nuclear reactors to the processing facilities at Hanford they were exposed to a series of chemicals designed to dissolve away the rod, which enabled workers to retrieve the plutonium. Once those chemicals were exposed to the fuel rods they became radioactive and extremely hot. They also couldn't be used in this process more than once. Because the chemicals are caustic and extremely hazardous to humans and the environment, underground storage tanks were built to hold these chemicals until a more permanent solution could be found. The underground storage tanks range in capacity from 55,000 gallons to more than 1 million gallons. The tanks were constructed with carbon steel and reinforced concrete. There are eighteen groups of tanks, called 'tank farms', some having as few as two tanks and others up to sixteen tanks. Between 1943 and 1964, 149 single-shell tanks were built at Hanford in the 200 West and East Areas. Heat generated by the waste and the composition of the waste caused an estimated 67 of these single-shell tanks to leak into the ground. Washington River Protection Solutions is the prime contractor responsible for the safe management of this waste. WRPS' mission is to reduce the risk to the environment that is posed by the waste. All of the pumpable liquids have been removed from the single-shell tanks and transferred to the double-shell tanks. What remains in the single-shell tanks are solid and semi-solid wastes. Known as salt-cakes, they have the consistency of wet beach sand. Some of the waste resembles small broken ice, or whitish crystals. Because the original pumps inside the tanks were designed to remove only liquid waste, other methods have been developed to reach the remaining waste. Access to the tank waste is through long, typically skinny pipes, called risers, extending out of the tanks. It is through these pipes that crews are forced to send machines and devices into the tanks that are used to break up the waste or push it toward a pump. These pipes range in size from just a few inches to just over a foot in diameter because they were never intended to be used in this manner. As part of the agreement regulating Hanford cleanup, crews must remove at least 99% of the material in every tank on the site, or at least as much waste that can be removed based on available technology. To date, seven single-shell tanks have been emptied, and work is underway in another 10 tanks in preparation for additional retrieval activities. Two barriers have been installed over single-shell tanks to prevent the intrusion of surface water down to the tanks, with additional barriers planned for the future. Single and double-shell tank integrity analyses are ongoing. Because the volume of the waste generated through plutonium production exceeded the capacity of the single-shell tanks, between 1968 and 1986 Hanford engineers built 28 double-shell tanks. These tanks were studied and made with a second shell to surround the carbon steel and reinforced concrete. The double-shell tanks have not leaked any of their waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FARM : an automated malware analysis environment.

We present the forensic analysis repository for malware (FARM), a system for automating malware analysis. FARM leverages existing dynamic and static analysis tools and is designed in a modular fashion to provide future extensibility. We present our motivations for designing the system and give an overview of the system architecture. We also present several common scenarios that detail uses for FARM as well as illustrate how automated malware analysis saves time. Finally, we discuss future development of this tool.

99 GENERAL AND MISCELLANEOUS↗

STATUS OF MECHANICAL SLUDGE REMOVAL AND COOLING COILS CLOSURE AT THE SAVANNAH RIVER SITE - F TANK FARM CLOSURE PROJECT - 9225

The Savannah River Site F-Tank Farm Closure project has successfully performed Mechanical Sludge Removal using the Waste on Wheels (WOW) system within two of its storage tanks. The Waste on Wheels (WOW) system is designed to be relatively mobile with the ability for many components to be redeployed to multiple tanks. It is primarily comprised of Submersible Mixer Pumps (SMPs), Submersible Transfer Pumps (STPs), and a mobile control room with a control panel and variable speed drives. These tanks, designated as Tank 6 and Tank 5 respectively, are Type I waste tanks located in F-Tank Farm (FTF) with a capacity of 2839 cubic meters (750,000 gallons) each. In addition, Type I tanks have 34 vertically oriented cooling coils and two horizontal cooling coil circuits along the tank floor. DOE intends to remove from service and operationally close Tank 5 and Tank 6 and other HLW tanks that do not meet current containment standards. After obtaining regulatory approval, the tanks and cooling coils will be isolated and filled with grout for long term stabilization. Mechanical Sludge Removal of the remaining sludge waste within Tank 6 removed {approx} 75% of the original 25,000 gallons in August 2007. Utilizing lessons learned from Tank 6, Tank 5 Mechanical Sludge Removal completed removal of {approx} 90% of the original 125 cubic meters (33,000 gallons) of sludge material in May 2008. The successful removal of sludge material meets the requirement of approximately 19 to 28 cubic meters (5,000 to 7,500 gallons) remaining prior to the Chemical Cleaning process. The Chemical Cleaning Process will utilize 8 wt% oxalic acid to dissolve the remaining sludge heel. The flow sheet for Chemical Cleaning planned a 20:1 volume ratio of acid to sludge for the first strike with mixing provided by the submersible mixer pumps. The subsequent strikes will utilize a 13:1 volume ratio of acid to sludge with no mixing. The results of the Chemical Cleaning Process are detailed in the 'Status of Chemical Cleaning of Waste Tanks at the Savannah River Site--F Tank Farm Closure Project--Abstract 9114'. To support Tank 5 and Tank 6 cooling coil closure, cooling coil isolation and full scale cooling coil grout testing was completed to develop a strategy for grouting the horizontal and vertical cooling coils. This paper describes in detail the performance of the Mechanical Sludge Removal activities and SMP operational strategies within Tank 5. In addition, it will discuss the current status of Tank 5 & 6 cooling coil isolation activities and the results from the cooling coil grout fill tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FARM : an automated malware analysis environment.

We present the forensic analysis repository for malware (FARM), a system for automating malware analysis. FARM leverages existing dynamic and static analysis tools and is designed in a modular fashion to provide future extensibility. We present our motivations for designing the system and give an overview of the system architecture. We also present several common scenarios that detail uses for FARM as well as illustrate how automated malware analysis saves time. Finally, we discuss future development of this tool.

97 MATHEMATICS AND COMPUTING↗

T Tank Farm Interim Surface Barrier Demonstration - Vadose Zone Monitoring FY08 Report

DOE’s Office of River Protection constructed a temporary surface barrier over a portion of the T Tank Farm as part of the T Farm Interim Surface Barrier Demonstration Project. The surface barrier is designed to minimize the infiltration of precipitation into the contaminated soil zone created by the Tank T-106 leak and minimize movement of the contamination. As part of the demonstration effort, vadose zone moisture is being monitored to assess the effectiveness of the barrier at reducing soil moisture. A solar-powered system was installed to continuously monitor soil water conditions at four locations (i.e., instrument Nests A, B, C, and D) beneath the barrier and outside the barrier footprint as well as site meteorological conditions. Nest A is placed in the area outside the barrier footprint and serves as a control, providing subsurface conditions outside the influence of the surface barrier. Nest B provides subsurface measurements to assess surface-barrier edge effects. Nests C and D are used to assess changes in soil-moisture conditions beneath the interim surface barrier.

54 ENVIRONMENTAL SCIENCES↗

Load assessment of a wind farm considering negative and positive yaw misalignment for wake steering

Wake steering strategies are employed to increase the overall power production of wind farms by deflecting wakes of upstream turbines away from downstream ones. The gain in net power comes at the expense of increased fatigue loads experienced by downstream turbines. In this work we investigate performance and fatigue loading characteristics of a small farm consisting of five aligned International Energy Agency Wind Technology Collaboration Programme 15 MW wind turbines. A parametric study is performed where, for every wind direction from −20 to 20°, the yaw misalignment angle varies from −25 to 25°. This setup allows us to investigate asymmetries and identify optimal conditions for a given wind direction. In general, we find that positive yaw configurations are preferred and that yaw configurations that result in attractive power differences when compared to a baseline no-yaw scenario (25 %) come with significant increase in fatigue loading (we use the standard deviation and damage-equivalent load (DEL) of the blade-root, low-speed shaft, and tower-base moments as proxies for fatigue load). We find that for any given positive wind inflow angle, yaw angles between −2.5 and 15° yield power differences of 10 %–20 % over a no-yaw baseline, and positive yaw is preferred because of lower fatigue loading. For any given negative wind inflow angles, positive yaw also results in lower magnitudes of standard deviation and DEL for the channels investigated. A small power loss of up to 2 % is observed for some positive yaw angles under negative wind directions (as compared to symmetric negative yaw and positive wind cases), but improvements in terms of loads exceed 25 % and may be enough to justify a positive yaw configuration under negative winds as well. We show that such behavior can be explained by partial waking and the direction of the rotation of the rotor.

17 WIND ENERGY↗

America’s First Offshore Wind Farm

This video display’s America’s first offshore wind farm. It’s the Block Island Wind Farm off the coast of Rhode Island. Its 5 turbines will produce 30MW of clean energy.

17 WIND ENERGY↗

AMR-Wind: A Performance-Portable, High-Fidelity Flow Solver for Wind Farm Simulations

We present AMR-Wind, a verified and validated high-fidelity computational-fluid-dynamics code for wind farm flows. AMR-Wind is a block-structured, adaptive-mesh, incompressible-flow solver that enables predictive simulations of the atmospheric boundary layer and wind plants. It is a highly scalable code designed for parallel high-performance computing with a specific focus on performance portability for current and future computing architectures, including graphical processing units (GPUs). In this paper, we detail the governing equations, the numerical methods, and the turbine models. Establishing a foundation for the correctness of the code, we present the results of formal verification and validation. The verification studies, which include a novel actuator line test case, indicate that AMR-Wind is spatially and temporally second-order accurate. The validation studies demonstrate that the key physics capabilities implemented in the code, including actuator disk models, actuator line models, turbulence models, and large eddy simulation (LES) models for atmospheric boundary layers, perform well in comparison to reference data from established computational tools and theory. We conclude with a demonstration simulation of a 12-turbine wind farm operating in a turbulent atmospheric boundary layer, detailing computational performance and realistic wake interactions.

17 WIND ENERGY↗