A Fast Quasi-Static Time Series Simulation Method for PV Smart Inverters with Var Control using Linear Sensitivity Model.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Efficient, rechargeable Mg and Ca batteries Divalent rechargeable metal batteries such as those based on magnesium and calcium are of interest because of the abundance of these elements and their lower tendency to form dendrites, but practical demonstrations are lacking. Hou et al . used methoxyethyl amine chelants in which the ligands attach to the metal atom in more than one place, modulating the solvation structure of the metal ions to enable a facile charge-transfer reaction (see the Perspective by Zuo and Yin). In full battery cells, these components lead to high efficiency and energy density. Theoretical calculations were used to understand the solvation structures. —MSL
We investigate the solution of low-rank matrix approximation problems using the truncated singular value decomposition (SVD). For this purpose, we develop and optimize graphics processing unit (GPU) implementations for the randomized SVD and a blocked variant of the Lanczos approach. Our work takes advantage of the fact that the two methods are composed of very similar linear algebra building blocks, which can be assembled using numerical kernels from existing high-performance linear algebra libraries. Furthermore, the experiments with several sparse matrices arising in representative real-world applications and synthetic dense test matrices reveal a performance advantage of the block Lanczos algorithm when targeting the same approximation accuracy.
Explore the source record for details and available documents.
Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety.
Explore the source record for details and available documents.
A large fraction of the gas in the Galaxy is cold, dense, and molecular. If all this gas collapsed under the influence of gravity and formed stars in a local free-fall time, the star formation rate in the Galaxy would exceed that observed by more than an order of magnitude. Other star-forming galaxies behave similarly. Yet, observations and simulations both suggest that the molecular gas is indeed gravitationally collapsing, albeit hierarchically. Prompt stellar feedback offers a potential solution to the low observed star formation rate if it quickly disrupts star-forming clouds during gravitational collapse. However, this requires that molecular clouds must be short-lived objects, raising the question of how so much gas can be observed in the molecular phase. This can occur only if molecular clouds form as quickly as they are destroyed, maintaining a global equilibrium fraction of dense gas. We therefore examine cloud formation timescales. We first demonstrate that supernova and superbubble sweeping cannot produce dense gas at the rate required to match the cloud destruction rate. On the other hand, Toomre gravitational instability can reach the required production rate. We thus argue that, although dense, star-forming gas may last only around a single global free-fall time; the dense gas in star-forming galaxies can globally exist in a state of dynamic equilibrium between formation by gravitational instability and disruption by stellar feedback. At redshift z ≳ 2, the Toomre instability timescale decreases, resulting in a prediction of higher molecular gas fractions at early times, in agreement with the observations.
We present optical and ultraviolet spectra of the first electromagnetic counterpart to a gravitational-wave (GW) source, the binary neutron star merger GW170817. Spectra were obtained nightly between 1.5 and 9.5 days post-merger, using the Southern Astrophysical Research and Magellan telescopes; the UV spectrum was obtained with the Hubble Space Telescope at 5.5 days. Our data reveal a rapidly fading blue component (T≈5500 K at 1.5 days) that quickly reddens; spectra later than ≳4.5 days peak beyond the optical regime. The spectra are mostly featureless, although we identify a possible weak emission line at ∼7900 Å at t≲4.5 days. The colors, rapid evolution, and featureless spectrum are consistent with a “blue” kilonova from polar ejecta comprised mainly of light r-process nuclei with atomic mass number A≲140. This indicates a sightline within θ{sub obs}≲45{sup ∘} of the orbital axis. Comparison to models suggests ∼0.03 M {sub ⊙} of blue ejecta, with a velocity of ∼0.3c. The required lanthanide fraction is ∼10{sup −4}, but this drops to <10{sup −5} in the outermost ejecta. The large velocities point to a dynamical origin, rather than a disk wind, for this blue component, suggesting that both binary constituents are neutron stars (as opposed to a binary consisting of a neutron star and a black hole). For dynamical ejecta, the high mass favors a small neutron star radius of ≲12 km. This mass also supports the idea that neutron star mergers are a major contributor to r-process nucleosynthesis.
Explore the source record for details and available documents.
Abstract not provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.
The Flow Analysis Software Toolkit, FAST, is a software environment for visualizing data. FAST is a collection of separate programs (modules) that run simultaneously and allow the user to examine the results of numerical and experimental simulations. The user can load data files, perform calculations on the data, visualize the results of these calculations, construct scenes of 3D graphical objects, and plot, animate and record the scenes. Computational Fluid Dynamics (CFD) visualization is the primary intended use of FAST, but FAST can also assist in the analysis of other types of data. FAST combines the capabilities of such programs as PLOT3D, RIP, SURF, and GAS into one environment with modules that share data. Sharing data between modules eliminates the drudgery of transferring data between programs. All the modules in the FAST environment have a consistent, highly interactive graphical user interface. Most commands are entered by pointing and'clicking. The modular construction of FAST makes it flexible and extensible. The environment can be custom configured and new modules can be developed and added as needed. The following modules have been developed for FAST: VIEWER, FILE IO, CALCULATOR, SURFER, TOPOLOGY, PLOTTER, TITLER, TRACER, ARCGRAPH, GQ, SURFERU, SHOTET, and ISOLEVU. A utility is also included to make the inclusion of user defined modules in the FAST environment easy. The VIEWER module is the central control for the FAST environment. From VIEWER, the user can-change object attributes, interactively position objects in three-dimensional space, define and save scenes, create animations, spawn new FAST modules, add additional view windows, and save and execute command scripts. The FAST User Guide uses text and FAST MAPS (graphical representations of the entire user interface) to guide the user through the use of FAST. Chapters include: Maps, Overview, Tips, Getting Started Tutorial, a separate chapter for each module, file formats, and system administration.
Idaho National Laboratory has a long and internationally recognized history of performing irradiation testing of advanced fast reactor fuels in the Experimental Breeder Reactor II (EBR-II) and the Advanced Test Reactor (ATR). Since EBR-II’s decommissioning in the early 1990’s, irradiation testing has been exclusively performed in ATR. The testing of fast reactor fuels in ATR is challenging given its thermal neutron spectrum and coolant temperatures far below those prototypic of fast reactors. Adept researchers have overcome these obstacles through the use of Cadmium shrouds which attenuate all thermalized neutrons and an experiment design that fosters fuel and cladding temperatures prototypic of fast neutron reactors. Although this design has successfully demonstrated temperatures and temperature gradients that closely mimic those seen in fast reactors, irradiation performance is highly sensitive to fabrication tolerances and the time requirements necessary for high fuel burnup, where irradiation performance data of fast fuel is lacking, are significant. This work summarizes two novel experiment designs and their associated physics analyses for testing fast reactor fuels in ATR; an accelerated irradiation experiment and a fast spectrum experiment. The accelerated irradiation experiment does not utilize a Cadmium shroud, has been shown to triple the burnup rate, yet yields temperatures and radial power profiles prototypic of fast reactor fuels. The fast spectrum experiment utilizes a booster fuel element that that hardens the incident neutron spectrum and also yields temperatures and radial power profiles prototypic of fast reactor fuels. These experiment designs efficiently reduce irradiation time requirements, are more economical, and significantly increase ATR throughput. Fast reactor experiments that capitalize on these designs expedite irradiation performance data for fast reactor fuels and provide information invaluable to fuel performance modeling and simulation validation over a wide range of parameters.
We have recently shown that conscious adrenalectomized rats exhibit nearly normal recovery of arterial blood pressure during the 5 h after hemorrhage. In those experiments, it appeared that a previous reduction in food intake might have compromised the recovery of blood pressure and increased mortality. These experiments were designed to test in conscious sham-adrenalectomized (control) and adrenalectomized rats prepared with indwelling arterial and venous cannulae: 1. The effects of a 20- to 24-h fast (compared to rats fed ab libitum) on the mobilization of plasma substrates and recovery of arterial blood pressure after a 15 ml/kg - 5 min hemorrhage, and 2. Vascular responsivity to pressor agents in fed or fasted groups before or 2 h after hemorrhage. In all rats hemorrhage resulted in decreased arterial pressure and heart rate. Arterial pressure recovered to near normal in both fed and fasted control groups and in the led adrenalectomized rats, and all of these rats survived for 24 h after stress. By contrast, in the fasted adrenalectomized rats, arterial pressure recovered only during the first 1.5 - 2 h and then failed, resulting in 100% mortality by 3-5 h. Compared to the other three groups, in which substrate levels either increased or remained fairly stable, plasma glucose and beta-hydoxybutyrate concentrations fell steadily, from 1.5-2 h after hemorrhage until death occurred in the fasted adrenalectomized rats. Basal ACTH concentrations were elevated cormpared to control values in both adrenalectomized groups (fed and fasted). Hemorrhage caused increases in plasma ACTH in all groups; the magnitude of the responses did not differ among the groups. The dilution of Evans' blue dve after hemorrhage (used as an index of fluid movement into the vascular space) was not different in contol and adrenalectomized rats (either fed or fasted). There were no differences in pressor responses to phenylephrine, vasopressin, or angiotensin-II between the fed and fasted condition in the control rats either before or after hemorrhage. There was a fasting-associated decrease in vascular responsivity, to vasopressin, but normal responsivity to phenylephrine and angiotensin-II, in the adrenal-ectomized rats both before and after hemorrhage. We conclude that: (1) since fed adrenalectomized rats all survived the stress, adrenal hormones are not required for survival unless fasting is a prior condition; (2) vascular responsiveness to phenylephrine and angiotensin-II is not altered by fasting and is, therefore, probably not the proximate cause of cardiovascular svstem failure; and (3) from these data we cannot distinguish between a failure in substrate supply and a failure in some component of the cardiovascular svstem, other than vascular responsivity, that results in death after hemorrhage in fasted adrenalectomized rats.
For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly {sup 3}He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of {mu}s) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.