At least 325 records · Page 18

Hematite at Meridiani Planum, Mars, Investigated by Simultaneous Fitting of MER Mossbauer Spectra

The Mars Exploration Rover Opportunity encountered sedimentary outcrop rocks at its landing site. Spherules with diameters in the millimeter range were found to weather from the outcrop rocks. With Opportunity s miniaturised M ssbauer spectrometer MIMOS II, hematite was detected in spherules and in the outcrop matrix [1,2]. Figure 1 shows the target Berry Bowl, where brushed outcrop and an accumulation of spherules could be investigated on sols 46 and 48 of Opportunity s mission. Hematite undergoes a transition from a weakly ferromagnetic above to an antiferromagnetic state below the Morin temperature (T(sub M) approx.265 K for chemically pure, crystalline hematite). The magnetic hyperfine splitting (B(sub hf)) shows a general decrease with increasing temperature and a drop of approx.0.8 T at T(sub M). The quadrupole splitting ((Delta)EQ) changes its sign at T(sub M), with negative values above and positive values below the transition. Crystallinity and particle size influence the magnitude and temperature dependence of the magnetic splitting and the quadrupole splitting [3].

Fleischer, I.↗

Two Devices for Removing Sludge From Bioreactor Wastewater

Two devices a magnetic separator and a special filter denoted a self-regenerating separator (SRS) have been developed for separating sludge from the stream of wastewater from a bioreactor. These devices were originally intended for use in microgravity, but have also been demonstrated to function in normal Earth gravity. The magnetic separator (see Figure 1) includes a thin-walled nonmagnetic, stainless-steel cylindrical drum that rotates within a cylindrical housing. The wastewater enters the separator through a recirculation inlet, and about 80 percent of the wastewater flow leaves through a recirculation outlet. Inside the drum, a magnet holder positions strong permanent magnets stationary and, except near a recirculation outlet, close to the inner drum surface. To enable magnetic separation, magnetite (a ferromagnetic and magnetically soft iron oxide) powder is mixed into the bioreactor wastewater. The magnetite becomes incorporated into the sludge by condensation, onto the powder particles, of microbe flocks that constitute the sludge. As a result, the magnets inside the drum magnetically attract the sludge onto the outer surface of the drum.

Archer, Shivaun↗

Single-Chip T/R Module for 1.2 GHz

A single-chip CMOS-based (complementary-metal-oxide-semiconductorbased) transmit/receive (T/R) module is being developed for L-band radar systems. Previous T/R module implementations required multiple chips employing different technologies (GaAs, Si, and others) combined with off-chip transmission lines and discrete components including circulators. The new design eliminates the bulky circulator, significantly reducing the size and mass of the T/R module. Compared to multi-chip designs, the single-chip CMOS can be implemented with lower cost. These innovations enable cost-effective realization of advanced phased array and synthetic aperture radar systems that require integration of thousands of T/R modules. The circulator is a ferromagnetic device that directs the flow of the RF (radio frequency) power during transmission and reception. During transmission, the circulator delivers the transmitted power from the amplifier to the antenna, while preventing it from damaging the sensitive receiver circuitry. During reception, the circulator directs the energy from the antenna to the low-noise amplifier (LNA) while isolating the output of the power amplifier (PA). In principle, a circulator could be replaced by series transistors acting as electronic switches. However, in practice, the integration of conventional series transistors into a T/R chip introduces significant losses and noise. The prototype single-chip T/R module contains integrated transistor switches, but not connected in series; instead, they are connected in a shunt configuration with resonant circuits (see figure). The shunt/resonant circuit topology not only reduces the losses associated with conventional semiconductor switches but also provides beneficial transformation of impedances for the PA and the LNA. It provides full singlepole/ double-throw switching for the antenna, isolating the LNA from the transmitted signal and isolating the PA from the received signal. During reception, the voltage on control line RX/TX (raised bar) is high, causing the field-effect transistor (FET) switch S1 to be closed, forming a parallel resonant tank circuit L1||C1. This circuit presents high impedance to the left of the antenna, so that the received signal is coupled to the LNA. At the same time, FET switches S2 and S3 are open, so that C2 is removed from the circuit (except for a small parasitic capacitance). The combination of L2 and C3 forms a matching network that transforms the antenna impedance of 50 ohms to a higher value from the perspective of the LNA input terminal. This transformation of impedance improves LNA noise figure by increasing the received voltage delivered to the input transistor. This allows lower transconductance and therefore a smaller transistor, which makes it possible to design the CMOS LNA for low power consumption. During transmission, the voltage on control line RX/TX (raised bar) is low, causing switch S1 to be open. In this configuration, the combination of L1 and C1 transforms the antenna impedance to a lower value from the perspective of the PA. This low impedance is helpful in producing a relatively high output power compatible with the low CMOS operating potential. At the same time, switches S2 and S3 are closed, forming the parallel resonant tank circuit L2||C2. This circuit presents high impedance to the right of the antenna, directing the PA output signal to the antenna and away from the LNA. During this time, S3 presents a short circuit across the LNA input terminals to guarantee that the voltage seen by the LNA is small enough to prevent damage.

Moussessian, Alina↗

Raman Scattering Studies in Dilute Magnetic Semiconductor Zn(1-x)Co(x)O

Raman spectra of ZnO and Co substituted Zn1-xCoxO (ZCO) were carried out using the Raman microprobe system with an p.,+ ion laser source of 514.5 nm wavelength. The shift towards the lower frequency side of the nonpolar E210w mode and the broadening due to Co substitution in ZnO were analyzed using the phonon confinement model. The magnetic measurements showed ferromagnetic behavior with the maximum saturation magnetization (1.2micron Beta/ErCo) for 10% Co substitution, which decreased wi th at further increase in Co concentrations. The intensities of E1(LO) at 584 cm-1 and multiphonon modes at 540 cm-1 were increased with an increase in Co substitution. The additional Raman modes in ceramic targets of ZCO spectra for higher concentration of Co substitution (x=15%-20%) were identified to be due to the spinel ZnCo2O4 secondary phase.

Samanta, K.↗

Magnetocaloric Pumping of Liquid Oxygen

The field-induced force density on a magnetic fluid is proportional to the magnetic susceptibility times the gradient of the magnetic field squared. The direction of the force is towards increasing magnetic field (positive gradient). Applying a magnetic field to a magnetic fluid will result in a force from all directions towards the location of peak field. Since the magnetic field is conservative and there are no magnetic monopoles, the net field-induced force on any fluid of constant susceptibly will be zero. The only manner to obtain a nonzero net field-induced force is to vary the susceptibility of the fluid. At the gas/liquid interface of liquid oxygen, the susceptibility varies drastically, and the exploitation of the resultant large net forces. An alternative method of varying the magnetic susceptibility is to vary the temperature of the fluid. The magnetic susceptibility of paramagnetic liquid oxygen obeys the Curie-Weiss law: it is inversely proportional to temperature. By applying a temperature gradient in the presence of a symmetric magnetic field, a nonzero net force results. Much of the theory of the so-called Magnetocaloric Effect has previously been developed for and applied to ferromagnetic fluids, or ferrofluids, but is readily applied to paramagnetic liquid oxygen.

Immer, Christopher↗

Electron-Spin Filters Based on the Rashba Effect

Semiconductor electron-spin filters of a proposed type would be based on the Rashba effect, which is described briefly below. Electron-spin filters more precisely, sources of spin-polarized electron currents have been sought for research on, and development of, the emerging technological discipline of spintronics (spin-based electronics). There have been a number of successful demonstrations of injection of spin-polarized electrons from diluted magnetic semiconductors and from ferromagnetic metals into nonmagnetic semiconductors. In contrast, a device according to the proposal would be made from nonmagnetic semiconductor materials and would function without an applied magnetic field. The Rashba effect, named after one of its discoverers, is an energy splitting, of what would otherwise be degenerate quantum states, caused by a spin-orbit interaction in conjunction with a structural-inversion asymmetry in the presence of interfacial electric fields in a semiconductor heterostructure. The magnitude of the energy split is proportional to the electron wave number. The present proposal evolved from recent theoretical studies that suggested the possibility of devices in which electron energy states would be split by the Rashba effect and spin-polarized currents would be extracted by resonant quantum-mechanical tunneling. Accordingly, a device according to the proposal would be denoted an asymmetric resonant interband tunneling diode [a-RITD]. An a-RITD could be implemented in a variety of forms, the form favored in the proposal being a double-barrier heterostructure containing an asymmetric quantum well. It is envisioned that a-RITDs would be designed and fabricated in the InAs/GaSb/AlSb material system for several reasons: Heterostructures in this material system are strong candidates for pronounced Rashba spin splitting because InAs and GaSb exhibit large spin-orbit interactions and because both InAs and GaSb would be available for the construction of highly asymmetric quantum wells. This mate-rial system affords a variety of energy-band alignments that can be exploited to obtain resonant tunneling and other desired effects. The no-common-atom InAs/GaSb and InAs/AlSb interfaces would present opportunities for engineering interface potentials for optimizing Rashba spin splitting.

Ting, David Z.-Y.↗

Tunable Optical True-Time Delay Devices Would Exploit EIT

Tunable optical true-time delay devices that would exploit electromagnetically induced transparency (EIT) have been proposed. Relative to prior true-time delay devices (for example, devices based on ferroelectric and ferromagnetic materials) and electronically controlled phase shifters, the proposed devices would offer much greater bandwidths. In a typical envisioned application, an optical pulse would be modulated with an ultra-wideband radio-frequency (RF) signal that would convey the information that one seeks to communicate, and it would be required to couple differently delayed replicas of the RF signal to the radiating elements of a phased-array antenna. One or more of the proposed devices would be used to impose the delays and/or generate the delayed replicas of the RF-modulated optical pulse. The beam radiated or received by the antenna would be steered by use of a microprocessor-based control system that would adjust operational parameters of the devices to tune the delays to the required values. EIT is a nonlinear quantum optical interference effect that enables the propagation of light through an initially opaque medium. A suitable medium must have, among other properties, three quantum states (see Figure 1): an excited state (state 3), an upper ground state (state 2), and a lower ground state (state 1). These three states must form a closed system that exhibits no decays to other states in the presence of either or both of two laser beams: (1) a probe beam having the wavelength corresponding to the photon energy equal to the energy difference between states 3 and 1; and (2) a coupling beam having the wavelength corresponding to the photon energy equal to the energy difference between states 3 and 2. The probe beam is the one that is pulsed and modulated with an RF signal.

Kulikov, Igor↗

Electromagnetic Characterization Of Metallic Sensory Alloy

Ferromagnetic shape-memory alloy (FSMA) particles undergo changes in both electromagnetic properties and crystallographic structure when strained. When embedded in a structural material, these attributes can provide sensory output of the strain state of the structure. In this work, a detailed characterization of the electromagnetic properties of a FSMA under development for sensory applications is performed. In addition, a new eddy current probe is used to interrogate the electromagnetic properties of individual FSMA particles embedded in the sensory alloy during controlled fatigue tests on the multifunctional material.

Wincheski, Russell A.↗

Non-Magnetic, Tough, Corrosion- and Wear-Resistant Knives From Bulk Metallic Glasses and Composites

Quality knives are typically fabricated from high-strength steel alloys. Depending on the application, there are different requirements for mechanical and physical properties that cause problems for steel alloys. For example, diver's knives are generally used in salt water, which causes rust in steel knives. Titanium diver's knives are a popular alternative due to their salt water corrosion resistance, but are too soft to maintain a sharp cutting edge. Steel knives are also magnetic, which is undesirable for military applications where the knives are used as a tactical tool for diffusing magnetic mines. Steel is also significantly denser than titanium (8 g/cu cm vs. 4.5 g/cu cm), which results in heavier knives for the same size. Steel is hard and wear-resistant, compared with titanium, and can keep a sharp edge during service. A major drawback of both steel and titanium knives is that they must be ground or machined into the final knife shape from a billet. Since most knives have a mirrored surface and a complex shape, manufacturing them is complex. It would be more desirable if the knife could be cast into a net or near-net shape in a single step. The solution to the deficiencies of titanium, steel, and ceramic knives is to fabricate them using bulk metallic glasses (or composites). These alloys can be cast into net or near-net shaped knives with a combination of properties that exceed both titanium and steel. A commercially viable BMG (bulk metallic glass) or composite knife is one that exhibits one or all of the following properties: It is based on titanium, has a self-sharpening edge, can retain an edge during service, is hard, is non-magnetic, is corrosion-resistant against a variety of corrosive environments, is tough (to allow for prying), can be cast into a net-shape with a mirror finish and a complex shape, has excellent wear resistance, and is low-density. These properties can be achieved in BMG and composites through alloy chemistry and processing. For each desired property for knife fabrication and performance, there is an alloy development strategy that optimizes behavior. Although BMG knives have been demonstrated as far back as 1995, they never found commercial success because they had to be ground (which presented problems because the alloys contained beryllium), they weren't low cost (because they weren't cast to a net-shape), they were brittle (because they were made with a low-quality commercial material), and they had extremely poor corrosion resistance (because corrosion was not well-understood in these materials). Ultimately, these shortcomings prevented the widespread commercialization. In the current work, the inventors have applied more than a decade of research on BMGs from Caltech and JPL to develop a better understanding of how to make BMG knives that exhibit an optimal combination of properties, processing and cost. Alloys have been developed based in titanium (and other metals), that exhibit high toughness, high hardness, excellent corrosion resistance, no ferromagnetism, edge-retaining selfsharpening, and the ability to be cast like a plastic using commercially available casting techniques (currently used by commercial companies such as Liquidmetal Technologies and Visser Precision Casting). The inventors argue that depending on the application (diving, military, tactical, utility, etc.) there is an optimal combination of design and alloy composition. Moreover, with new casting technologies not available at the inception of these materials, net-shaped knives can be cast into complex shapes that require no aftermarket forming, except for sharpening using water-cooled polishing wheel. These combinations of discoveries seek to make low-cost BMG knives commercially viable products that have no equal among metal or ceramic knives. Current work at JPL focuses on net-shape casting of these alloys and testing their mechanical properties versus commercially available knives to demonstrate their benefits.

Hoffman, Douglas C.↗

Evaluation of Magnetoresistive RAM for Space Applications

Magnetoresistive random-access memory (MRAM) is a non-volatile memory that exploits electronic spin, rather than charge, to store data. Instead of moving charge on and off a floating gate to alter the threshold voltage of a CMOS transistor (creating different bit states), MRAM uses magnetic fields to flip the polarization of a ferromagnetic material thus switching its resistance and bit state. These polarized states are immune to radiation-induced upset, thus making MRAM very attractive for space application. These magnetic memory elements also have infinite data retention and erase/program endurance. Presented here are results of reliability testing of two space-qualified MRAM products from Aeroflex and Honeywell.

Heidecker, Jason↗

Magnetic Tunnel Junction-Based On-Chip Microwave Phase and Spectrum Analyzer

A magnetic tunnel junction (MTJ)-based microwave detector is proposed and investigated. When the MTJ is excited by microwave magnetic fields, the relative angle between the free layer and pinned layer alternates, giving rise to an average resistance change. By measuring the average resistance change, the MTJ can be utilized as a microwave power sensor. Due to the nature of ferromagnetic resonance, the frequency of an incident microwave is directly determined. In addition, by integrating a mixer circuit, the MTJ-based microwave detector can also determine the relative phase between two microwave signals. Thus, the MTJbased microwave detector can be used as an on-chip microwave phase and spectrum analyzer.

Fan, Xin↗

Magnetic Tunnel Junction-Based On-Chip Microwave Phase and Spectrum Analyzer

A magnetic tunnel junction (MTJ)-based microwave detector is proposed and investigated. When the MTJ is excited by microwave magnetic fields, the relative angle between the free layer and pinned layer alternates, giving rise to an average resistance change. By measuring the average resistance change, the MTJ can be utilized as a microwave power sensor. Due to the nature of ferromagnetic resonance, the frequency of an incident microwave is directly determined. In addition, by integrating a mixer circuit, the MTJ-based microwave detector can also determine the relative phase between two microwave signals. Thus, the MTJ-based microwave detector can be used as an on-chip microwave phase and spectrum analyzer.

microwave spectra↗

Broadband Characterization of Stress Induced Anisotropy in Nanocomposite Co74.6Fe2.7Mn2.7Nb4Si2B14

We report on the broadband characterization of Co74:6Fe2:7Mn2:7Nb4Si2B14 (at%) melt-spun, soft magnetic alloy ribbons after various secondary processing treatments. Ribbons were investigated in the as-cast (melt-spun) condition, after annealing under stress at 50 - 200 MPa, and after transverse magnetic field (TMF) annealing. The magnetization dynamics of these materials have been studied from 10 - 60 GHz using ferromagnetic resonance (FMR). The in-plane uniaxial anisotropy was determined from the FMR data and permeability extracted for each condition. The permeability determined from broadband FMR was in good agreement with independently determined values using vibrating sample magnetometry and impedance spectrometry of toroidal cores. The effective damping parameter (α (sub ϱff)) of all the samples was close to 0.015 except for the TMF sample, which showed higher damping, possibly due to two magnon scattering.

Abhishek Srivastava↗

TPSAS-NF1676L-13664-DND

The safety of aerospace vehicles is largely dependent on the ability of modern non-destructive evaluation (NDE) tools to accurately detect structural damage before a critical flaw size is reached. However, existing NDE technologies are inherently limited by the physical response of the materials being inspected making the detection of small cracks or pre-crack damage difficult. One innovative solution to this problem is to create a multifunctional metallic material that can be used in structural applications and contains second phase sensory particles that significantly enhance the ability of conventional NDE techniques to detect incipient damage during use and at regularly scheduled inspections. Ferromagnetic shape-memory alloys (FSMAs) are an ideal material for use as this second phase material as they undergo a uniform and repeatable change in both magnetic properties and crystallographic structure when strained. These changes are more readily detected than small cracks, thereby, allowing for enhanced detection of damage by conventional NDE techniques. In this study, a multifunctional metallic material was produced by embedding the sensory material particles within an aluminum alloy to form a sensory alloy. The NDE response of the FSMA and the sensory alloy during tension/compression and fatigue loading have been investigated. These results suggest that sensory alloys can be utilized for improved on-board structural health monitoring and to improve the accuracy and reduce time for ground-based inspection.

T. A. Wallace↗

Stratigraphy of the Apollo 17 Landslide Core 73002 From FMR Maturity and VNIR and Mössbauer Spectroscopy

A suite of samples from the Apollo missions to the Moon (1969-1973) were set aside and stored under controlled conditions to have unexamined lunar samples available decades later for analyses that take advantage of evolved sample handling techniques, maturation of then existing instrumentation, and development of new analytical techniques and instrumentation [e.g., 1]. One preserved sample is the Apollo 17 double drive tube core (73001/2) that was driven into the lunar surface on the landslide deposit at Station 3 on the South Massif in the Taurus-Littrow valley [2]. The deeper section (73001) was stored frozen in a Core Sample Vacuum Container (CSVC) to maximize preservation of lunar volatiles. We report here, as a part of the Apollo Next Generation Sample Analysis (ANGSA) Initiative [1,3], stratigraphy for the upper core section (73002) with respect to maturity (ferromagnetic resonance (FMR) maturity index Is/FeO [4-6]), visible-near-IR (VNIR) spectroscopy, and, for representative samples, grain-size analysis and Mössbauer spectroscopy. Stratigraphy provides data to model the dynamics of lunar landslide deposits and their post-emplacement evolution in comparison to impact-driven mixing on an airless body and stratigraphic context for volatile and (if any) organic behavior. Reported by [7] are preliminary results for multispectral imaging and hyperspectral scanning of the first dissection pass of 73002.

R. V. Morris↗

Determining Surface Exposure Ages of Regolith Grains in Lunar Core Sample 73002 By Investigating Solar Particle Irradiation Damage

Space weathering causes the surface soils of airless bodies like the Moon to be micro-structurally and chemically altered by exposure to micrometeoroid bombardment and solar wind irradiation. These alterations accumulate in surface grains with continued residence in the uppermost millimeters of regolith. Low energy solar wind ions (largely H+ and He+) produce a layer of radiation damage as they become implanted in grain surfaces. Also present are solar energetic particle (SEP) tracks, which are nanoscale lineations within grain interiors formed by heavy, high-energy ions (mainly Fe group nuclei) penetrating up to millimeters below the surface. Recent work has determined that the width of solar wind-damaged rims on anorthite and olivine, and their respective SEP track densities are correlated with each other and with grain surface exposure age. Core sample 73002, recently released under the Apollo Next Generation Sample Analysis (ANGSA) Program, has provided an opportunity to study material collected from the light mantle formation in the Taurus-Littrow Valley during Apollo 17. The light mantle is thought to have been deposited vial and slide originating from the neighboring South Massif. Spectral analysis of bulk core soils found a plagioclase rich composition, confirming a highlands origin of the formation. Spectral profiles and ferromagnetic resonance (FMR) measurements of bulk soils sampled at cm-intervals from 73002 indicate that regolith up to~9.5 cm in depth have maturity indices consistent with longer durations of surface processing than samples deeper in the core. Thus, this upper ~9 cm layer likely represents the maximum extent of an in-situ reworking zone which may have persisted over 5 to 17million years. Here we present an analysis of grain exposure ages within the in-situ reworking zone of 73002derived from SEP track density measurements via transmission electron microscopy.

J A McFadden↗