Color Maintenance of LEDs in Laboratory and Field Applications

Synopsis: To date, consideration for parametric failure of LED products has largely been focused on lumen maintenance. However, color shift is a cause of early failure for some products, and is especially important to consider in certain applications, like museums, where visual appearance is critical. Example data collected by the GATEWAY program for LED lamps installed in museums shows that many have changed color beyond a reasonable tolerance well before their rated lifetime was reached, necessitating replacement. Similar data collected by the CALiPER program between 2008 and 2010 reveals that many early products shifted beyond acceptable tolerances in as little as a few thousand hours. In contrast, data from the L Prize program illustrates that commercially available LED products can have exemplary color stability that is unmatched by traditional light sources. Beyond presenting data from the aforementioned DOE programs, this report discusses the metrics used for communicating color shift—namely MacAdam ellipses and Δu'v'—as well as providing guidance for end users on how to monitor color shift and what to look for in manufacturer warranties. Also included are descriptions of the physical changes that have been documented as leading to color shift in some example types of LED packages. As with complete products, the data presented herein for LED packages shows that a wide variety of products are available; in order for specifiers and consumers to make educated choices, more detailed and standardized information should be made available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dielectrics Under Extreme Electric Fields: In Situ Studies on Nanoscale Mechanisms (Final Technical Report)

The lack of materials that can function reliably under extreme electric fields is a critical roadblock to achieving higher energy efficiency and extended service lifetime of devices in electricity generation, transmission, and consumption. Materials typically fail at two or three orders of magnitude below their theoretical dielectric breakdown strength. Identifying the origins of premature dielectric breakdown using state-of-the-art characterization tools will, therefore, enable the design and discovery of transformational materials capable of approaching their intrinsic limits. The vast improvement in the resolution power of imaging tools, combined with the recently developed in situ electric biasing technique, has made high resolution observations of dielectric breakdown as it happens possible. The overall goal of the project is to directly image the dynamic processes of defect formation, accumulation, and interaction with preexisting defects (e.g., dislocations, domain walls, and grain boundaries in crystalline dielectric films) under electric fields up to 1,000 MV/m with a temporal resolution better than 5 microseconds. Using the newly acquired, custom-made Hysitron PI95 transmission electron microscopy (TEM) specimen holder, in situ TEM observations of breakdown at the sub nanometer resolution will be made on representative dielectric compounds with progressive complexities: the linear dielectric SiO 2 , CuO, and TiO 2 , the ferroelectric BaTiO 3 nanocrystals and nanocubes. Through direct observation of the breakdown event at high spatial and temporal resolutions, the nanoscale mechanisms for the failure of dielectrics under intense electric fields will be identified. The results of the project will be applied to the design and processing of new dielectric materials with higher efficiency, improved reliability, and a prolonged lifetime. Such new dielectrics are urgently needed for modernizing energy infrastructures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electro-Thermal Simulation Studies of SiC Junction Diodes Containing Screw Dislocations Under High Reverse-Bias Operation

The objective of this work was to conduct a modeling study of SiC P-N junction diodes operating under high reverse biased conditions. Analytical models and numerical simulation capabilities were to be developed for self-consistent electro-thermal analysis of the diode current-voltage (I-V) characteristics. Data from GRC indicate that screw dislocations are unavoidable in large area SiC devices, and lead to changes in the SiC diode electrical response characteristics under high field conditions. For example, device instability and failures linked to internal current filamentation have been observed. The physical origin of these processes is not well understood, and quantitative projections of the electrical behavior under high field and temperature conditions are lacking. Thermal calculations for SiC devices have not been reported in the literature either. So estimates or projections of peak device temperatures and power limitations do not exist. This numerical study and simulation analysis was aimed at resolving some of the above issues. The following tasks were successfully accomplished: (1) Development of physically based models using one- and two-dimensional drift-diffusion theory for the transport behavior and I-V characteristics; (2) One- and two-dimensional heat flow to account for internal device heating. This led to calculations of the internal temperature profiles, which in turn, were used to update the electrical transport parameters for a self-consistent analysis. The temperature profiles and the peak values were thus obtainable for a given device operating condition; (3) Inclusion of traps assumed to model the presence of internal screw dislocations running along the longitudinal direction; (4) Predictions of the operating characteristics with and without heating as a function of applied bias with and without traps. Both one and two-dimensional cases were implemented; (5) Assessment of device stability based on the operating characteristics. The presence of internal non-uniformities, particularly filamentary structures, was probed and demonstrated; (6) Cause and physical origins of filamentary behavior and unstable I-V characteristics were made transparent; (7) It was demonstrated that diodes containing defects would be more prone to thermal breakdown associated with the temperature dependent decrease in the thermal conductivity; and (8) Finally, negative differential resistance (S-shaped NDR) which can potential lead to device instability and filamentary behavior was shown to occur for diodes containing a line of defects such as could be associated with a screw dislocation line.

Joshi, R. P.↗

Synergies Between the Kepler, K2 and TESS Missions with the PLATO Mission (Revised)

Two transit survey missions will have been flown by NASA prior to the launch of ESA's PLATO Mission in 2026, laying the groundwork for exoplanet discovery via the transit method. The Kepler Mission, which launched in 2009, collected data on its 100+ square degree field of view for four years before failure of a reaction wheel ended its primary mission. The results from Kepler include 2300+ confirmed or validated exoplanets, 2200+ planetary candidates, 2100+ eclipsing binaries. Kepler also revolutionized the field of asteroseismology by measuring the pressure mode oscillations of over 15000 solar-like stars spanning the lifecycle of such stars from hydrogen-burning dwarfs to helium-burning red giants. The re-purposed Kepler Mission, dubbed K2, continues to observe fields of view in and near the ecliptic plane for 80 days each, significantly broadening the scope of the astrophysical investigations as well as discovering an additional 156 exoplanets to date. The TESS mission will launch in 2017 to conduct an all-sky survey for small exoplanets orbiting stars 10X closer and 100X brighter than Kepler exoplanet host stars, allowing for far greater follow-up and characterization of their masses as well as their sizes for at least 50 small planets. Future assets such as James Webb Space Telescope, and ground-based assets such as ESOs Very Large Telescope (VLT) array, the Exremely Large Telescope (ELT), and the Thirty Meter Telescope (TMT) will be able to characterize the atmospheric composition and properties of these small planets. TESS will observe each 24 X 96 field of view for 30 days and thereby cover first the southern and then the northern hemisphere over 13 pointings during each year of the primary mission. The pole-most camera will observe the James Webb continuous viewing zone for one year in each hemisphere, permitting much longer period planets to be detected in this region. The PLATO mission will seek to detect habitable Earth-like planets with an instrument composed of 26 small telescopes in several 2232 square deg FOVs with a range of observation durations over a mission lifetime of up to eight years. This paper summarizes the findings of the KeplerK2 missions, previews the likely results from the TESS mission, and explores the lessons learned and to be learned from these prior missions that can be incorporated into the observation and data reduction strategy for the PLATO Mission so as to maximize the science return.

exoplanet detection↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A phase-field fracture formulation for generalized standard materials: The interplay between thermomechanics and damage

Accurately modeling fracture of ductile materials poses open challenges in the field of computational mechanics due to the multiphysics nature of their failure processes. Integrating the interplay between thermodynamics and damage into ductile fracture models is vital for predicting critical failure modes. Here, in this paper, we develop a versatile phase-field (PF) framework for modeling ductile fracture, taking into account finite-strain elasto-plasticity. The framework stems from a variational formulation of constitutive relations for generalized standard materials (GSMs), whose response is described by a Helmholtz free energy and a dissipation pseudo-potential. Its variational structure is based on a minimum principle for a functional that expresses the sum of power densities for reversible and irreversible processes. By minimizing this functional with a constraint on a von Mises yield function, we derive the evolution equation for the equivalent plastic strain and an associative flow rule. This constrained optimization problem is analytically solved for a wide class of thermo-viscoplasticity models. The key innovations of the current work include (i) a cubic plastic degradation function that accounts for a non-vanishing damage-dependent yield stress, (ii) closed-form expressions of the Helmholtz free energy and dissipation pseudo-potential for three thermo-viscoplasticity models, (iii) an extended Johnson–Cook plasticity model with a nonlinear hardening law, and (iv) a plastic work heat source that depends on the plastic degradation function and a variable Taylor–Quinney (TQ) coefficient. The capabilities of the proposed framework are tested with the aid of four ductile fracture problems, including the Sandia Fracture Challenge. In each of these problems, we examine the evolution of relevant field variables such as the PF order parameter, the equivalent plastic strain, the temperature, and the internal power dissipation density, in addition to the overall structural response quantified by the force–displacement curve. These numerical studies demonstrate that the proposed framework effectively represents ductile fracture, yielding computational results that exhibit good agreement with experimental data.

36 MATERIALS SCIENCE↗

Multiscale Characterization of Photovoltaic Modules—Case Studies of Contact and Interconnect Degradation

The current popularity of photovoltaic (PV) systems is due in large part to their exceptional reliability and significantly lower cost than other energy sources. Studying cell and module degradation is key to promote further development in the state of the art. Fielded or accelerated aged modules exhibit different failure modes, of which metallization degradation (contacts and interconnections) is prevalent. In this work, we discuss how multiscale characterization methods can be applied to a variety of module technologies that have been field exposed and have undergone accelerated age testing. These methods include performing characterization on the module level, cell level, and finally the materials level. The observed performance losses from the module- and cell-level characterization can be correlated with materials properties to find out the root cause of degradation. We recommend an initial nondestructive characterization suite, including module- and cell-level current-voltage ( I--V ), Suns-V OC , photoluminescence and electroluminescence imaging, quantum efficiency, ultraviolet fluorescence imaging, and thermal infrared imaging. Samples are then extracted from particularly degraded regions of the module and prepared for materials characterization techniques, such as top-down and cross-sectional scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry, Raman spectroscopy, and transmission electron microscopy, allowing a deeper look into the mechanism behind the metallization degradation. This article serves as an instructional review to introduce the different multiscale characterization methods and how they can be effectively applied to perform PV degradation studies. Furthermore, we also share some of our examples and discuss the strengths, limitations, and best practices for each of the characterization techniques.

14 SOLAR ENERGY↗

An Effective Preoperative Three-Dimensional Radiotherapy Target Volume for Extremity Soft Tissue Sarcoma and the Effect of Margin Width on Local Control

Purpose: There is little information on the appropriate three-dimensional (3D) preoperative radiotherapy (XRT) volume for extremity soft-tissue sarcomas (STS). We retrospectively analyzed the pattern of local failure (LF) to help elucidate optimal field design. Methods and Materials: We analyzed the 56 patients who underwent computed tomography-planned XRT for Stage I to III extremity STS between June 2000 and December 2006. Clinical target volume (CTV) included the T1 post-gadolinium-defined gross tumor volume with 1- to 1.5-cm radial and 3.5-cm longitudinal margins. Planning target volume expansion was 5 to 7 mm, and {>=}95% of dose was delivered to the planning target volume. Preoperative XRT was 44 to 50.4 Gy (median, 50). Postoperative boost of 10 to 20 Gy was given to 12 patients (6 with positive and 6 with close margins). Results: Follow-up ranged from 15 to 76 months (median, 41 months). The 5-year local control, freedom from distant metastasis, disease-free survival, and overall survival were 88.5%, 80.0%, 77.5% and 82.8%, respectively. Three patients (all with positive margin) experienced local failure (LF) as first relapse (2 isolated, 1 with distant failure), and 2 additional patients (all with margin<1 mm) had late LF after distant metastasis. The LFs were within the CTV in 3 patients and within and also extending beyond the CTV in 2 patients. Conclusions: These target volume definitions appear to be appropriate for most patients. No local recurrences were observed with surgical margins {>=}1 mm, and it appears that these may be adequate for patients with extremity STS treated with preoperative radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FPGA Reliability and Failure Rate Analysis for Launch and Space Vehicles Environments

Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will demonstrate guidelines to estimate FPGA failure rates for ascent and in space operations. The guidelines will account for hardware and radiation-induced failures, as well as Bayesian updates to failure rates. The hardware contribution of the approach accounts for physical failures of the FPGA IC. The radiation portion will expand on FPGA susceptibility to different space radiation environments.

Al Hassan, Mohammad↗

Dielectrics for long term space exposure and spacecraft charging: A briefing

Charging of dielectrics is a bulk, not a surface property. Radiation driven charge stops within the bulk and is not quickly conducted to the surface. Very large electric fields develop in the bulk due to this stopped charge. At space radiation levels, it typically requires hours or days for the internal electric fields to reach steady state. The resulting electric fields are large enough to produce electrical failure within the insulator. This type failure is thought to produce nearly all electric discharge anomalies. Radiation also induces bond breakage, creates reactive radicals, displaces atoms and, in general, severely changes the chemistry of the solid state material. Electric fields can alter this process by reacting with charged species, driving them through the solid. Irradiated polymers often lose as much as a percent of their mass, or more, at exposures typical in space. Very different aging or contaminant emission can be induced by the stopped charge electric fields. These radiation effects are detailed.

Frederickson, A. R.↗

Tension fracture of laminates for transport fuselage. Part 2: Large notches

Tests were conducted on over 200 center-crack specimens to evaluate: (a) the tension-fracture performance of candidate materials and laminates for commercial fuselage applications; and (b) the accuracy of several failure criteria in predicting response. Crack lengths of up to 12 inches were considered. Other variables included fiber/matrix combination, layup, lamination manufacturing process, and intraply hybridization. Laminates fabricated using the automated tow-placement process provided significantly higher tension-fracture strengths than nominally identical tape laminates. This confirmed earlier findings for other layups, and possibly relates to a reduced stress concentration resulting from a larger scale of repeatable material inhomogeneity in the tow-placed laminates. Changes in material and layup result in a trade-off between small-notch and large-notch strengths. Toughened resins and 0 deg-dominate layups result in higher small-notch strengths but lower large-notch strengths than brittle resins, 90 deg and 45 deg dominated layups, and intraply S2-glass hybrid material forms. Test results indicate that strength-prediction methods that allow for a reduced order singularity of the crack-tip stress field are more successful at predicting failure over a range of notch sizes than those relying on the classical square-root singularity. The order of singularity required to accurately predict large-notch strength from small-notch data was affected by both material and layup. Measured crack-tip strain distributions were generally higher than those predicted using classical methods. Traditional methods of correcting for finite specimen width were found to be lacking, confirming earlier findings with other specimen geometries. Fracture tests of two stiffened panels, identical except for differing materials, with severed central stiffeners resulted in nearly identical damage progression and failure sequences. Strain-softening laws implemented within finite element models appear attractive to account for load redistribution in configured structure due to damage-induced crack tip softening

Walker, Tom H.↗

Post-impact fatigue of cross-plied, through-the-thickness reinforced carbon/epoxy composites

An experimental investigation of the post-impact fatigue response of integrally woven carbon/epoxy composites was conducted. Five different through-the-thickness (TTT) reinforcing fibers were used in an experimental textile process that produced an integrally woven (0/90/0/90/0/90/0/90/0)(sub T) ply layup with 21K AS4 carbon tow fiber. The resin was Hercules 3501-6, and the five TTT reinforcing fibers were Kevlar, Toray carbon, AS4 carbon, glass, and IM6 carbon. The purpose of this investigation was to study the post-impact fatigue response of these material systems and to identify the optimum TTT fiber. Samples were impacted with one half inch diameter aluminum balls with an average velocity of 543 ft/sec. Post-impact static compression and constant amplitude tension-compression fatigue tests were conducted. Fatigue tests were conducted with a loading ratio of R=-5, and frequency of 4 Hz. Damage growth was monitored using x-radiographic and sectioning techniques and by examining the stress-strain response (across the impact site) throughout the fatigue tests. The static compressive stress versus far-field strain response was nearly linear for all material groups. All the samples had a transverse shear failure mode. The average compressive modulus (from far-field strain) was about 10 Msi. The average post-impact static compressive strength was about 35.5 Ksi. The IM6 carbon sample had a strength of over 40 Ksi, more than 16 percent stronger than average. There was considerable scatter in the S-N data. However, the IM6 carbon samples clearly had the best fatigue response. The response of the other materials, while worse than IM6 carbon, could not be ranked definitively. The initial damage zones caused by the impact loading and damage growth from fatigue loading were similar for all five TTT reinforcing materials. The initial damage zones were circular and consisted of delaminations, matrix cracks and ply cracks. Post-impact fatigue loading caused delamination growth, ply cracking and fiber bundle failures, typically 45 deg from impact load direction. During the initial 97 percent of fatigue life, delaminations, ply cracks and fiber bundle failures primarily grew at and near the impact site. During the final 3 percent of life, damage grew rapidly transverse to the loading direction as a through-the-thickness transverse shear failure. The stress-strain response was typically linear during the initial 50 percent of life, and stiffness dropped about 20 percent during this period. During the next 47 percent of life, stiffness dropped about 34 percent, and the stress-strain response was no longer linear. The stiffness decreased about 23 percent during the final 3 percent of life. These trends were typical of all the materials tested. Therefore, by monitoring stiffness loss, fatigue failure could be accurately anticipated.

Serdinak, Thomas E.↗

Mathematical test criteria for filtering complex systems: Plentiful observations

An important emerging scientific issue is the real time filtering through observations of noisy turbulent signals for complex systems as well as the statistical accuracy of spatio-temporal discretizations for such systems. These issues are addressed here in detail for the setting with plentiful observations for a scalar field through explicit mathematical test criteria utilizing a recent theory [A.J. Majda, M.J. Grote, Explicit off-line criteria for stable accurate time filtering of strongly unstable spatially extended systems, Proceedings of the National Academy of Sciences 104 (4) (2007) 1124-1129]. For plentiful observations, the number of observations equals the number of mesh points. These test criteria involve much simpler decoupled complex scalar filtering test problems with explicit formulas and elementary numerical experiments which are developed here as guidelines for filter performance. The theory includes information criteria to avoid filter divergence with large model errors, asymptotic Kalman gain, filter stability, and accurate filtering with small ensemble size as well as rigorous results delineating the role of various turbulent spectra for filtering under mesh refinement. These guidelines are also applied to discrete approximations for filtering the stochastically forced dissipative advection equation with very turbulent and noisy signals with either an equipartition of energy or -5/3 turbulent spectrum with infrequent observations as severe test problems. The theory and companion simulations demonstrate accurate statistical filtering in this context with implicit schemes with large time step with very small ensemble sizes and even with unstable explicit schemes under appropriate circumstances provided the filtering strategies are guided by the off-line theoretical criteria. The surprising failure of other strongly stable filtering strategies is also explained through these off-line criteria.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Why PV Inverter Failures May Lead to AC Power Quality Issues

Case study examines a common PV inverter failure that can drive uncommon issues in the field - namely, damage to the AC protection equipment from DC fault currents for short periods during transformer-less inverter power electronic failures.

14 SOLAR ENERGY↗

Shear strain anomalies in composite beam specimens by moire interferometry

Experimental analyses were performed for determination of in-plane deformations and shear strains in unidirectional and quasi-isotropic graphite-epoxy beams. Forty-eight-ply beams were subjected to five-point and three-point flexure. Whole-field measurements were recorded at load levels from about 20 percent to more than 90 percent of failure loads. Contour maps of U and W displacement fields were obtained by moire interferometry, using reference gratings of 2400 lines/mm. Clearly defined fringes with fringe orders exceeding 1000 were obtained. Whole-field contour maps of shear strains were obtained. Various anomalous effects were detected in the displacement fields. Their analysis indicated excess shear strains in resin-rich zones in regions of shear tractions; free-edge shear strains in quasi-isotropic specimens in regions of normal stresses, and shear stresses associated with cyclic shear compliances of quasi-isotropic laminates in regions of shear tractions. Their contributions could occur independently or in superposition. Qualitative analyses addressed questions of the effect of specimen overhang, nonlinearity, and characteristics of five-point and three-point flexure tests.

Post, D.↗

Turbomachine Sealing and Secondary Flows: Review of Rotordynamics Issues in Inherently Unsteady Flow Systems With Small Clearances - Part 2

Today's computational methods enable the determination of forces in complex systems, but without field validation data, or feedback, there is a high risk of failure when the design envelope is challenged. The data of Childs and Bently and field data reported in NASA Conference Proceedings serve as sources of design information for the development of these computational codes. Over time all turbomachines degrade and instabilities often develop, requiring responsible, accurate, turbomachine diagnostics with proper decisions to prevent failures. Tam et al. (numerical) and Bently and Muszynska (analytical) models corroborate and implicate that destabilizing factors are related through increases in the fluid-force average circumferential velocity. The stability threshold can be controlled by external swirl and swirl brakes and increases in radial fluid film stiffness (e.g., hydrostatic and ambient pressures) to enhance rotor stability. Also cited are drum rotor self-excited oscillations, where the classic fix is to add a split or severed damper ring or cylindrical damper drum, and the Benkert-Wachter work that engendered swirl brake concepts. For a smooth-operating, reliable, long-lived machine, designers must pay very close attention to sealing dynamics and diagnostic methods. Correcting the seals enabled the space shuttle main engine high-pressure fuel turbopump (SSME HPFTP) to operate successfully.

Hendricks, R. C.↗

In-situ imaging of flexure-induced fracture in tape-laminate composites using high-resolution X-ray computed tomography

Here, this study presents development of an in-situ flexure test for imaging progressive inter- and intralaminar fracture in tape-laminate composites using X-ray computed tomography (CT). The intent of this test is to provide detailed experimental observations of ply-level damage that can be used to validate existing, and develop new, progressive damage analysis (PDA) tools. The test consists of a vertically mounted specimen which is flexed using two eccentric compressive loads using an in-situ uniaxial load stage. The flexure specimen contains a starter notch mid-span which promotes initiation of composite failure within the X-ray field of view. Specimens with two different laminate stacking sequences were tested, imaged, analyzed. For a quasi-isotropic laminate with large angle changes between adjacent plies, there was near simultaneous growth of transverse cracks and delaminations below the midplane of the laminate. For a laminate with small angles between adjacent plies, there was extensive formation of transverse crack networks which penetrated the laminate thickness without delamination growth. In addition to imaging fracture, the X-ray CT data from both specimen types were used to quantify the variability in thickness and analyze the local orientation of individual plies. Overall, the proposed test and the image-data analysis methodology provided an important insight into the fracture processes in tape laminates and highlights the inherent ply-level geometrical variabilities that should be accounted for in PDA simulations.

42 ENGINEERING↗