Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUIDICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Multiphase Large Eddy Simulation of a Pulsed Sieve-Plate Extraction Column - 18125

Presented here is research resulting from a framework of single-phase and multiphase modelling trials. These are intended to accurately simulate the internal flow phenomena arising in pulsed sieve-plate extraction columns representative of those found in industry. Three-dimensional unsteady flow calculations using large eddy simulation coupled with dynamic sub-grid scale modelling have been used to capture the transient effects of sinusoidal flow conditions using the open source CFD code OpenFOAM{sup R}. Multiphase interface interactions are modelled using the volume of fluid method with appropriate heavy and light phase fluidic properties capturing surface tension, density and viscous effects. The system studied consists of a 150 mm diameter column with two perforated plates with a fractional free area of 25 %, operational under 1 Hz pulsing frequency at a 50 mm amplitude and plate spacing of 300 mm. The materials simulated include water (single-phase) and 3 M nitric acid and dodecane / tributyl phosphate mixture at 30 vol% (multiphase). Results are compared with appropriate correlations from literature. The dispersive mixing efficiency of the system was also evaluated via a mixing index value which allows quantification of the ratio of rotational and irrotational flow components. This study has found that the predictive methods employed are effective at capturing the different scales of turbulence present within pulsed sieve-plate extraction columns, and its influence on their operation. As such, the work highlights the ability of large eddy simulation-based modelling to predict the complex flows in such column geometries. Furthermore, the techniques employed provide valuable insight into the hydrodynamic flow characteristics and mixing mechanisms arising within pulsed sieve-plate extraction columns. (authors)

42 ENGINEERING↗

In Situ X-Ray Analysis of Protein Crystals in Low-Birefringent And X-Ray Transmissive Plastic Microchannels

Plastic microchannel crystallization template designs made from inexpensive cyclic olefin copolymers have been shown to be low-birefringent, X-ray transmissive and compatible with microfluidic fabrication in restricted geometry. The model proteins thaumatin, lysozyme and bacteriorhodopsin demonstrated the feasibility of conducting counter-diffusion equilibration within the new plastic configuration. Crystals of each of these proteins were directly evaluated in situ using synchrotron radiation and their diffraction quality was evaluated without invasive manipulation or cryofreezing. Protein crystals able to produce complete X-ray data sets were used to calculate electron-density maps for structure determination. Fluidic crystallization in the plastic platform was also coupled with a commercialized automated imager and an in situ X-ray scanner that allowed optical and X-ray inspection of crystallization hits. The results demonstrate the feasibility of rapid nanovolume counter-diffusion crystallization experiments without the need for additional instrumentation.

43 PARTICLE ACCELERATORS↗

Offline solid phase microextraction sampling system

An offline solid phase microextraction (SPME) sampling apparatus for enabling SPME samples to be taken a number of times from a previously collected fluid sample (e.g. sample atmosphere) stored in a fused silica lined bottle which keeps volatile organics in the fluid sample stable for weeks at a time. The offline SPME sampling apparatus has a hollow body surrounding a sampling chamber, with multiple ports through which a portion of a previously collected fluid sample may be (a) released into the sampling chamber, (b) SPME sampled to collect analytes for subsequent GC analysis, and (c) flushed/purged using a fluidically connected vacuum source and purging fluid source to prepare the sampling chamber for additional SPME samplings of the same original fluid sample, such as may have been collected in situ from a headspace.

Harvey, Chris A↗

AUTOMATED PROCESS MONITORING: APPLYING PROVEN AUTOMATION TECHNIQUES TO INTERNATIONAL SAFEGUARDS NEEDS

Identification and quantification of specific alpha- and beta-emitting radionuclides in complex liquid matrices is highly challenging, and is typically accomplished through laborious wet chemical sample preparation and separations followed by analysis using a variety of detection methodologies (e.g., liquid scintillation, gas proportional counting, alpha energy analysis, mass spectrometry). Analytical results may take days or weeks to report. Chains of custody and sample security measures may also complicate or slow the analytical process. When an industrial process-scale plant requires the monitoring of specific radionuclides as an indication of the composition of its feed stream or of plant performance, radiochemical measurements must be fast, accurate, and reliable. Scientists at Pacific Northwest National Laboratory have assembled a fully automated prototype Process Monitor instrument capable of a variety of tasks: automated sampling directly from a feed stream, sample digestion / analyte redox adjustment, chemical separations, radiochemical detection and data analysis / reporting. The system is compact, its components are fluidically inter-linked, and analytical results could be immediately transmitted to on- or off-site locations. The development of a rapid radiochemical Process Monitor for 99Tc in Hanford tank waste processing streams, capable of performing several measurements per hour, will be discussed in detail. More recently, the automated platform was modified to perform measurements of 90Sr in Hanford tank waste stimulant. The system exemplifies how automation could be integrated into reprocessing facilities to support international nuclear safeguards needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RAPID AUTOMATED RADIOCHEMICAL ANALYZER FOR DETERMINATION OF TARGETED RADIONUCLIDES IN NUCLEAR PROCESS STREAMS

Some industrial process-scale plants require the monitoring of specific radionuclides as an indication of the composition of their feed streams or as indicators of plant performance. In this process environment, radiochemical measurements must be fast, accurate, and reliable. Manual sampling, sample preparation, and analysis of process fluids are highly precise and accurate, but tend to be expensive and slow. Scientists at Pacific Northwest National Laboratory (PNNL) have assembled and characterized a fully automated prototype Process Monitor instrument which was originally designed to rapidly measure Tc-99 in the effluent streams of the Waste Treatment Plant at Hanford, WA. The system is capable of a variety of tasks: extraction of a precise volume of sample, sample digestion / analyte redox adjustment, column-based chemical separations, flow-through radiochemical detection and data analysis / reporting. The system is compact, its components are fluidically inter-linked, and analytical results can be immediately calculated and electronically reported. It is capable of performing a complete analytical cycle in less than 15 minutes. The system is highly modular and can be adapted to a variety of sample types and analytical requirements. It exemplifies how automation could be integrated into reprocessing facilities to support international nuclear safeguards needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automation of Extraction Chromatograhic and Ion Exchange Separations for Radiochemical Analysis and Monitoring

Radiochemical analysis, complete with the separation of radionuclides of interest from the sample matrix and from other interfering radionuclides, is often an essential step in the determination of the radiochemical composition of a nuclear sample or process stream. Although some radionuclides can be determined nondestructively by gamma spectroscopy, where the gamma rays penetrate significant distances in condensed media and the gamma ray energies are diagnostic for specific radionuclides, other radionuclides that may be of interest emit only alpha or beta particles. For these, samples must be taken for destructive analysis and radiochemical separations are required. For process monitoring purposes, the radiochemical separation and detection methods must be rapid so that the results will be timely. These results could be obtained by laboratory analysis or by radiochemical process analyzers operating on-line or at-site. In either case, there is a need for automated radiochemical analysis methods to provide speed, throughput, safety, and consistent analytical protocols. Classical methods of separation used during the development of nuclear technologies, namely manual precipitations, solvent extractions, and ion exchange, are slow and labor intensive. Fortunately, the convergence of digital instrumentation for preprogrammed fluid manipulation and the development of new separation materials for column-based isolation of radionuclides has enabled the development of automated radiochemical analysis methodology. The primary means for separating radionuclides in solution are liquid-liquid extraction and ion exchange. These processes are well known and have been reviewed in the past.1 Ion exchange is readily employed in column formats. Liquid-liquid extraction can also be implemented on column formats using solvent-impregnated resins as extraction chromatographic materials. The organic liquid extractant is immobilized in the pores of a microporous polymer material. Under suitable conditions, the analyte of interest partitions into the immobilized organic phase while other matrix speces and interferences are washed away in the mobile aqueous phase. After the wash step, retained analytes are rapidly released in one or more steps by changing the aqueous eluent, such that the analytes now partition back into the mobile phase. The development of solvent impregnated resins, their physical chemistry, technological applications for metal and radionuclide recovery, and analytical uses were described in detail in a previous chapter in this series by Cortina and Warshawsky. The extraction chromatographic approach is well suited for the isolation of radionuclides from complex sample matrixes in a rapid automated format. The development of automated radioanalytical methods is, in fact, closely coupled to the availability of such materials. In this review, we will focus on the application of radiochemical separations in automated fluidic formats for the analysis of alpha- and beta-emitting radionuclides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Carbon nanotube heat-exchange systems

A carbon nanotube heat-exchange system (10) and method for producing the same. One embodiment of the carbon nanotube heat-exchange system (10) comprises a microchannel structure (24) having an inlet end (30) and an outlet end (32), the inlet end (30) providing a cooling fluid into the microchannel structure (24) and the outlet end (32) discharging the cooling fluid from the microchannel structure (24). At least one flow path (28) is defined in the microchannel structure (24), fluidically connecting the inlet end (30) to the outlet end (32) of the microchannel structure (24). A carbon nanotube structure (26) is provided in thermal contact with the microchannel structure (24), the carbon nanotube structure (26) receiving heat from the cooling fluid in the microchannel structure (24) and dissipating the heat into an external medium (19).

42 ENGINEERING↗

Real-time gross actinide monitoring in extreme (10 6 :1) beta-gamma background fluid streams using mini-ATMFDs

Real-time, trace alpha activity monitoring in extreme mixed radiation fields is a well-known challenge in fission product-rich streams containing mixtures of beta-gamma-alpha radiation-emitting isotopes, arising due to the extreme 10 6 :1 ratio of background beta-gamma vs. alpha radiation activity levels. This paper presents results from a novel approach to addressing this challenge, based on Tensioned Metastable Fluid Detector (TMFD) sensing technology. An acoustically driven technique was developed and tested at Purdue University (using dissolved Rn-Po and U-chain alpha emitters), and validated (with dissolved Pu) at Savannah River National Laboratory for real-time monitoring of alpha activity in the 100–10,000 dpm/mL range.

Environmental Monitoring↗

A wearable patch for continuous analysis of thermoregulatory sweat at rest

The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl - , and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson’s disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.

47 OTHER INSTRUMENTATION↗

Functional Janus structured liquids and aerogels

Janus structures have unique properties due to their distinct functionalities on opposing faces, but have yet to be realized with flowing liquids. We demonstrate such Janus liquids with a customizable distribution of nanoparticles (NPs) throughout their structures by joining two aqueous streams of NP dispersions in an apolar liquid. Using this anisotropic integration platform, different magnetic, conductive, or non-responsive NPs can be spatially confined to opposite sides of the original interface using magnetic graphene oxide (mGO)/GO, Ti 3 C 2 T x /GO, or GO suspensions. The resultant Janus liquids can be used as templates for versatile, responsive, and mechanically robust aerogels suitable for piezoresistive sensing, human motion monitoring, and electromagnetic interference (EMI) shielding with a tuned absorption mechanism. The EMI shields outperform their current counterparts in terms of wave absorption, i.e., SE T ≈ 51 dB, SE R ≈ 0.4 dB, and A = 0.91, due to their high porosity ranging from micro- to macro-scales along with non-interfering magnetic and conductive networks imparted by the Janus architecture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An apparatus for studying scintillator properties at high isostatic pressures

We describe the design and operation of a unique hydraulic press for the study of scintillator materials under isostatic pressure. This press, capable of developing a pressure of a gigapascal, consists of a large sample chamber pressurized by a two-stage hydraulic amplifier. The optical detection of the scintillation light emitted by the sample is performed, through a large aperture optical port, by a photodetector located outside the pressure vessel. In addition to providing essential pressure-dependent studies on the emission characteristics of radioluminescent materials, this apparatus is being developed to elucidate the mechanisms behind the recently observed dependency of light-yield nonproportionality on electronic band structure. The variation of the light output of a Tl:CsI crystal under 511-keV gamma excitation and hydrostatic pressure is given as an example.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Macroscopic strain controlled ion current in an elastomeric microchannel

We report on the fabrication of an ultra-high aspect ratio ionically conductive single microchannel with tunable diameter from ≈ 20 μm to fully closed. The 4 mm-long channel is fabricated in a Polydimethylsiloxane (PDMS) mold and its cross-sectional area is controlled by applying macroscopic compressive strain to the mold in a direction perpendicular to the channel length. We investigated the ionic conduction properties of the channel. For a wide range of compressive strain up to ≈ 0.27, the strain dependence of the resistance is monotonic and fully reversible. For strain > 0.27, ionic conduction suddenly shuts off and the system becomes hysteretic (whereby a finite strain reduction is required to reopen the channel). Upon unloading, the original behavior is retrieved. This reversible behavior is observed over 200 compression cycles. The cross-sectional area of the channel can be inferred from the ion current measurement, as confirmed by a Nano-Computed Tomography investigation. We show that the cross-sectional area decreases monotonically with the applied compressive strain in the reversible range, in qualitative agreement with linear elasticity theory. We find that the shut-off strain is affected by the spatial extent of the applied strain, which provides additional tunability. Our tunable channel is well-suited for multiple applications in micro/nano-fluidic devices.

36 MATERIALS SCIENCE↗

Note: On-chip multifunctional fluorescent-magnetic Janus helical microswimmers

Microswimmers integrated into microfluidic devices that are capable of self-illumination through fluorescence could revolutionize many aspects of technology, especially for biological applications. Few illumination and propulsion techniques of helical microswimmers inside microfluidic channels have been demonstrated. This paper presents the fabrication, detachment, and magnetic propulsions of multifunctional fluorescent-magnetic helical microswimmers integrated inside microfluidics. The fabrication process is based on two-photon laser lithography to pattern 3-D nanostructures from fluorescent photoresist coupled with conventional microfabrication techniques for magnetic thin film deposition by shadowing. After direct integration inside a microfluidic device, injected gas bubble allows gentle detachment of the integrated helical microswimmers whose magnetic propulsion can then be directly applied inside the microfluidic channel using external electromagnetic coil setup. With their small scale, fluorescence, excellent resistance to liquid/gas surface tension, and robust propulsion capability inside the microfluidic channel, the microswimmers can be used as high-resolution and large-range mobile micromanipulators inside microfluidic channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-range forces affecting equilibrium inertial focusing behavior in straight high aspect ratio microfluidic channels

The controlled and directed focusing of particles within flowing fluids is a problem of fundamental and technological significance. Microfluidic inertial focusing provides passive and precise lateral and longitudinal alignment of small particles without the need for external actuation or sheath fluid. The benefits of inertial focusing have quickly enabled the development of miniaturized flow cytometers, size-selective sorting devices, and other high-throughput particle screening tools. Straight channel inertial focusing device design requires knowledge of fluid properties and particle-channel size ratio. Equilibrium behavior of inertially focused particles has been extensively characterized and the constitutive phenomena described by scaling relationships for straight channels of square and rectangular cross section. In concentrated particle suspensions, however, long-range hydrodynamic repulsions give rise to complex particle ordering that, while interesting and potentially useful, can also dramatically diminish the technique’s effectiveness for high-throughput particle handling applications. We have empirically investigated particle focusing behavior within channels of increasing aspect ratio and have identified three scaling regimes that produce varying degrees of geometrical ordering between focused particles. To explore the limits of inertial particle focusing and identify the origins of these long-range interparticle forces, we have explored equilibrium focusing behavior as a function of channel geometry and particle concentration. Experimental results for highly concentrated particle solutions identify equilibrium thresholds for focusing that scale weakly with concentration and strongly with channel geometry. Balancing geometry mediated inertial forces with estimates for interparticle repulsive forces now provide a complete picture of pattern formation among concentrated inertially focused particles and enhance our understanding of the fundamental limits of inertial focusing for technological applications.

42 ENGINEERING↗

Microfluidic volumetric flow determination using optical coherence tomography speckle: An autocorrelation approach

Functional modalities of Optical Coherence Tomography (OCT) based on speckle analysis are emerging in the literature. We propose a simple approach to the autocorrelation of OCT signal to enable volumetric flow rate differentiation, based on decorrelation time. Our results show that this technique could distinguish flows separated by 3 μl/min, limited by the acquisition speed of the system. We further perform a B-scan of gradient flow inside a microchannel, enabling the visualization of the drag effect on the walls.

42 ENGINEERING↗

Evidence of a rolling motion of a microparticle on a silicon wafer in a liquid environment

The interaction of micro- and nanometer-sized particles with surfaces plays a crucial role when small-scale structures are built in a bottom-up approach or structured surfaces are cleaned in the semiconductor industry. For a reliable quantification of the interaction between individual particles and a specific surface, however, the motion type of the particle must be known. We developed an approach to unambiguously distinguish between sliding and rolling particles. To this end, fluorescent particles were partially bleached in a confocal laser scanning microscope to tailor an optical inhomogeneity, which allowed for the identification of the characteristic motion pattern. For the manipulation, the water flow generated by a fast moving cantilever-tip of an atomic force microscope enabled the contactless pushing of the particle. We thus experimentally evidenced a rolling motion of a micrometer-sized particle directly with a fluorescence microscope. A similar approach could help to discriminate between rolling and sliding particles in liquid flows of microfluidic systems.

42 ENGINEERING↗

Robotic automation of droplet microfluidics

Droplet microfluidics enables powerful analytic capabilities but often requires workflows involving macro- and microfluidic processing steps that are cumbersome to perform manually. Here, we demonstrate the automation of droplet microfluidics with commercial fluid-handling robotics. The workflows incorporate common microfluidic devices including droplet generators, mergers, and sorters and utilize the robot's native capabilities for thermal control, incubation, and plate scanning. The ability to automate microfluidic devices using commercial fluid handling will speed up the integration of these methods into biological workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic Cell for Studying the Precrystallization Stage Structure of Protein Solutions by Small-Angle X-Ray Scattering

A microfluidic cell has been developed for studying the structure of protein solutions using small-angle X-ray scattering. The use of prefabricated elements, which provide a small sample volume, allows one to adjust the microfluidic cell parameters to specific problems. Tests of lysozyme solutions were performed on a laboratory diffractometer AMUR-K (Institute of Crystallography, Russian Academy of Sciences), BM29 beamline (ESRF, Grenoble), and “DICSY” beamline of the Kurchatov synchrotron radiation source (National Research Centre “Kurchatov Institute”). Experiments showed that, when a 60-μm-thick quartz glass of special purity grade is applied as an X-ray-transparent window, the intrinsic level of cell background scattering in the range of measured angles is lower than that for quartz capillaries, due to which the measurement accuracy can be increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗