Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Design principle and calculations of a Scheffler fixed focus concentrator for medium temperature applications

Scheffler fixed focus concentrators are successfully used for medium temperature applications in different parts of the world. These concentrators are taken as lateral sections of paraboloids and provide fixed focus away from the path of incident beam radiations throughout the year. The paper presents a complete description about the design principle and construction details of an 8 m{sup 2} surface area Scheffler concentrator. The first part of the paper presents the mathematical calculations to design the reflector parabola curve and reflector elliptical frame with respect to equinox (solar declination = 0) by selecting a specific lateral part of a paraboloid. Crossbar equations and their ellipses, arc lengths and their radii are also calculated to form the required lateral section of the paraboloid. Thereafter, the seasonal parabola equations are calculated for two extreme positions of summer and winter in the northern hemisphere (standing reflectors). The slopes of the parabola equations for equinox (solar declination = 0), summer (solar declination = +23.5) and winter (solar declination = -23.5) for the Scheffler reflector (8 m{sup 2} surface area) are calculated to be 0.17, 0.28, and 0.13 respectively. The y-intercepts of the parabola equations for equinox, summer and winter are calculated as 0, 0.54, and -0.53 respectively. By comparing with the equinox parabola curve, the summer parabola is found to be smaller in size and uses the top part of the parabola curve while the winter parabola is bigger in size and uses the lower part of the parabola curve to give the fixed focus. For this purpose, the reflector assembly is composed of flexible crossbars and a frame to induce the required change of the parabola curves with the changing solar declination. The paper also presents the calculation procedure of seasonal parabola equations for standing reflectors in the southern hemisphere as well as for laying reflectors in the northern and southern hemispheres. Highly reflective aluminium sheets are used on the crossbar profiles to complete the concentrator. The reflector is installed at the required site by setting its axis of rotation at an angle equal to the latitude of the site. For daily tracking, these concentrators rotate along an axis parallel to the polar axis of the earth at an angular velocity of one revolution per day with the help of simpler and cheaper self-tracking devices. For seasonal tracking, the reflector rotates at half the solar declination angle with the help of a telescopic clamp mechanism. The design procedure is simple, flexible and does not need any special computational setup, thus offering the prospect of potential application in domestic as well as industrial configurations. (author)

14 SOLAR ENERGY↗

Correlative Raman spectroscopy and focused ion beam for targeted phase boundary analysis of titania polymorphs

Site-specific preparation of specimens using focused ion beam instruments for transmission electron microscopy is at the forefront of targeting regions of interest for nanoscale characterization. Typical methods of pinpointing desired features include electron backscatter diffraction for differentiating crystal structures and energy-dispersive X-Ray spectroscopy for probing compositional variations. Yet there are situations, notably in the titanium dioxide system, where these techniques can fail. Differentiating between the brookite and anatase polymorphs of titania is either excessively laborious or impossible with the aforementioned techniques. However, due to differences in bonding structure, Raman spectroscopy serves as an ideal candidate for polymorph differentiation. In this work, a correlative approach utilizing Raman spectroscopy for targeted focused ion beam specimen preparation was employed. Dark field imaging and diffraction in the transmission electron microscope confirmed the region of interest located via Raman spectroscopy and demonstrated the validity of this new method. Correlative Raman spectroscopy, scanning electron microscopy, and focused ion beam is shown to be a promising new technique for identifying site-specific preparation of nanoscale specimens in cases where conventional approaches do not suffice.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Quantifying Dissolution Dynamics in Porous Media Using a Spatial Flow Focusing Profile

Abstract The diverse range of patterns in porous media formed by dissolution processes depends on the relative magnitude of flow, transport, and chemical reactions at pore surfaces. However, distinguishing between regimes often relies solely on qualitative, visual comparisons of emergent structures. Here, we propose a quantitative measure capable of identifying different regimes using the concept of the spatial flow focusing profile, which segments the medium into cross sections along the flow direction to calculate the flow focusing index for each section. We employ this measure in numerical simulations of a dissolving porous medium using a pore network model. We obtain a morphological phase diagram of dissolution patterns, which we characterize using the flow focusing profile. In particular, we demonstrate that analyzing the temporal changes in the profile allows one to quantitatively distinguish between wormholing and channeling. The transition between them is shown to be affected by the heterogeneity of the system.

58 GEOSCIENCES↗

Intensity dependence of relativistic focusing of intense laser beams propagating in plasmas

Optical guiding of an intense laser beam propagating in uniform plasmas is analyzed by means of the variational method. The focusing properties of the beam are shown to be governed by the laser power as well as the laser intensity. An increase in the laser intensity leads to an enhancement of ponderomotive self-channeling but a stronger weakening of relativistic self-focusing. The oscillations of the beam spot size along the propagation distance come from the variability of the focusing force in terms of the laser intensity; and the dependence on the laser intensity is negligible in the weakly relativistic limit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Activation Technique and MCNP Calculations for Measurement of Fast Neutron Spatial Distribution at the MJ Plasma Focus Device

In this paper Plasma-Focus (PF) neutron emission properties have been studied using Monte Carlo calculations for neutron and photon transport. A Thermal Neutron Scaling Factor as a function of angular position of silver activation detectors placed around MJ Plasma Focus (PF-1000) device has been calculated. Detector responses calculated for 2.5 MeV neutrons and neutrons produced by Am-Be calibration source have been obtained .The results have shown the detector response dependence on the kind of calibration neutron source and on local geometrical/structural characteristics of the PF-1000 devices. Thus the proper calibration procedure ought to be performed for correct measurement of neutron yield within Plasma-Focus devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of plasma distribution in electron-focused electric field enhanced glow discharge plasma immersion ion implantation

In enhanced glow discharge plasma immersion ion implantation (EGDPIII) that involves a small pointed anode and large area tabular cathode, the high negative substrate bias not only acts as the plasma producer but also supplies the implantation voltage. Consequently, an electric field is created to focus the electrons and the electron-focusing field enhances the glow discharge process. In this work, the plasma distribution is measured using a Langmuir probe to obtain the plasma density. Numerical interpolation is performed to obtain the plasma density distribution throughout the entire discharge region. The effects of different distances between the anode and cathode on the glow discharge characteristics and the influence of the plasma electron density are also evaluated. Our results experimentally verify the electron-focusing phenomenon and suggest optimal processing windows for enhanced ionization rates and efficiency in EGDPIII.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small angle x-ray scattering with a beryllium compound refractive lens as focusing optic

At BW4 at HASYLAB a beryllium compound refractive lens (Be-CRL) is used for the focusing in small-angle x-ray scattering experiments. Using it provides the advantages of higher long-term stability and a much easier alignment compared to a setup with focusing mirrors. In our investigations presented here, we show the advantages of using a Be-CRL in small-angle and also ultra small-angle x-ray scattering. We investigated the beam characteristics at the sample position with respect to spot size and photon flux. The spot size is comparable to that of a setup with focusing mirrors but with a gain in flux and better long-term stability. It is also shown that plane mirrors are still necessary to suppress higher order energies passing the monochromator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined effect of tight-focusing and frequency-chirping on laser acceleration of an electron in vacuum

The investigation [Gupta et al., Appl. Phys. Lett. 91, 211101 (2007)] for electron acceleration by a tightly focused laser beam is revisited by including the effect of laser frequency chirping. The frequency chirping plays an important role to enhance the electron energy if the laser is tightly focused. Due to the combined effect of frequency chirping and tight focusing of a laser beam, an electron can be accelerated for a longer time in vacuum. As a result, from the proposed investigation, the electron energy gain during the laser acceleration is found to be considerably higher.

43 PARTICLE ACCELERATORS↗

Ion energy distribution near a plasma meniscus for multielement focused ion beams

The axial ion energy spread near a plasma meniscus for multielement focused ion beams is investigated experimentally in atomic and molecular gaseous plasmas of krypton, argon, and hydrogen by tailoring the magnetic field in the region. In the case of magnetic end plugging, the ion energy spread reduces by approx50% near the meniscus as compared to the bulk plasma, thereby facilitating beam focusing. A quadrupole filter can be used to control the mean energy of the ions. Comparison with standard Maxwellian and Druyvesteyn distributions with the same mean energy indicates that the ion energy distribution in the meniscus is deficient in the population of low and high energy tail ions, resulting in a Gaussian-like profile with a spread of approx4 and approx5 eV for krypton and argon ions, respectively. By carefully tuning the wave power, plasma collisionality, and the magnetic field in the meniscus, the spread can be made lower than that of liquid metal ion sources, for extracting focused ion beams of other elements with adequate current density, for research and applications in nanosystems

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft x-ray yield from NX2 plasma focus

The Lee model code is used to compute neon soft x-ray yield Y{sub sxr} for the NX2 plasma focus as a function of pressure. Comparison with measured Y{sub sxr} shows reasonable agreement in the Y{sub sxr} versus pressure curve, the absolute maximum yield as well as the optimum pressure. This gives confidence that the code gives a good representation of the neon plasma focus in terms of gross properties including speeds and trajectories and soft x-ray yields, despite its lack of modeling localized regions of higher densities and temperatures. Computed current curves versus pressure are presented and discussed particularly in terms of the dynamic resistance of the axial phase. Computed gross properties of the plasma focus including peak discharge current I{sub peak}, pinch current I{sub pinch}, minimum pinch radius r{sub min}, plasma density at the middle duration of pinch n{sub pinch}, and plasma temperature at middle duration of pinch T{sub pinch} are presented and the trends in variation of these are discussed to explain the peaking of Y{sub sxr} at optimum pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Results Of A 600 Joules Small Plasma Focus Device

Preliminary results of a 600 J (3.7 muF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0+-0.5 mubar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validity of closed periodic magnetic focusing for sheet electron beams

Theoretical analyses and numerical calculations have demonstrated that a closed periodic cusped magnetic (PCM) field can effectively confine a sheet electron beam in two transverse directions (i.e., in the wide and narrow dimensions, simultaneously) for stable long distance transport in which the sizes of the beam cross section are set by referring to the present state of the art. Moreover, the method for matching the transverse magnetic focusing force and the inner space charge force in the wide dimension of the sheet electron beam is given, and the longitudinal periodic length and the cross sectional shape of the closed PCM focusing structure can be determined. Calculations also demonstrate that the optimum focusing state can be attained by adjusting the wide dimension on the transverse section of the closed PCM structure independently. The work presented in this paper indicates that the closed PCM structure is very promising for the confinement of the sheet electron beam, and it can be helpful for guiding practical engineering design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emittance estimation by an ion optical element with variable focusing strength and a viewing target

The emittance of an extracted ion beam can be estimated to first order by a series of three linear independent profile measurements. This estimation is restricted to the evaluation of an upper limit of the emittance value for a homogeneous, nonfilamented beam. The beam is assumed to be round, respectively elliptical, without any structure of the intensity distribution, no space charge has been assumed for the drifting beam, and the optics is assumed to be linear. Instead of using three different drift sections, a linear focusing element with three different focusing strengths can be used. Plotting the beam radius as function of focusing strength, three independent solutions can be used to calculate the Twiss parameters {alpha}, {beta}, and {gamma} and furthermore the emittance {epsilon}. Here we describe the measurements which have been performed with the SECRAL ion source at Institute of Modern Physics Lanzhou.

43 PARTICLE ACCELERATORS↗

Highly asymmetric Laue focusing monochromator

By using two highly asymmetric Laue crystals in a dispersive arrangement with a circular profile (Oe 8 mm) we have created a sagittaly focusing Laue system for the first time. The crystallographic planes (111) of the two Si crystals formed an angle of 7.95 deg. with the entrance surface. The crystals dimensions were 40 mmx20 mm and the diffracting surface was a 0.5 mm thick neck between the two circular profiles. The 15.35 keV diffracted beam formed an angle of 0.55 deg. with the exit surface. The calculated focusing distance of the Laue-Laue focusing system was 14 m.

43 PARTICLE ACCELERATORS↗

Nonstationary ponderomotive self-focusing of a Gaussian laser pulse in a plasma

A model of relaxing ponderomotive nonlinearity is developed to study the nonstationary self-focusing of a Gaussian laser pulse in a plasma. The ponderomotive force acts on the electrons instantaneously but the plasma density redistribution via the process of ambipolar diffusion is taken to evolve on the time scale {tau}{sub R} congruent with r{sub 0}/c{sub s}, where r{sub 0} is the laser spot size and c{sub s} is the sound speed. The paraxial ray approximation is used to solve the wave equation. The focusing is stronger at the rear of the pulse than at the front, causing considerable distortion of the pulse when pulse duration is comparable to nonlinearity relaxation time. The saturation effect of nonlinearity leads to focusing of any portion of the pulse to a minimum spot size r{sub 0}f{sub min} at an optimum distance z{sub op} and then the spot size increases. f{sub min} and z{sub op} depend on the intensity of the portion of the pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ponderomotive acceleration of electrons by a self focused laser pulse

Ponderomotive acceleration of electrons by a short laser pulse undergoing relativistic self-focusing in a plasma is investigated. The saturation in nonlinear plasma permittivity causes periodic self-focusing of the laser. The periodicity lengths are different for different axial segments of the pulse. As a result, pulse shape is distorted. An electron initially on the laser axis and at the front of the self-focusing pulse gains energy from the pulse until it is run over by the pulse peak. By the time electron reaches the tail, if pulse begins diverging, the deceleration of the electron is slower and the electron is left with net energy gain. The electrons slightly off the laser axis see a radial ponderomotive force too. Initially, when they are accelerated by the pulse front the acceleration is strong as they are closer to the axis. When they see the tail of the pulse (after being run by the pulse), they are farther from the axis and the retardation ponderomotive force is weaker. Thus, there is net energy gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal and spatial study of neon ion emission from a plasma focus device

The temporal and spatial characteristics of the neon ion beam emissions from a low energy plasma focus device have been studied by employing a multiple Faraday cup assembly and the CR-39 track detectors at different angular and axial positions. In addition, the operating gas pressures were also varied to study the temporal and spatial characteristics of the neon ion beam emissions. The Faraday cup analyses show that the ion flux strongly depends on the operating gas pressure as well as the angular positions. The estimated ion energy measurements at the aperture of the Faraday cup indicate that the plasma focus device is a source of polyenergetic ions ranging from approximately a few keV to a few hundreds of keV, irrespective of the angular positions. The exposed CR-39 detectors have shown the formation of multiple ion tracks with diameter ranging from 2 to 13 {mu}m. The populations of lower diameter tracks (2-6 {mu}m) are observed to be more at 0 deg. and 10 deg. angles. It is also noticed that the most populated track counts have shifted toward the higher diameter as the angular positions change from 0 deg. to 70 deg. The present study enables us to predict a clear picture of ion flux and energy distribution inside the plasma focus chamber that will help to use the device for material irradiation application in a more controlled manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗