Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

DSN system performance test Doppler noise models; noncoherent configuration

The newer model for variance, the Allan technique, now adopted for testing, is analyzed in the subject mode. A model is generated (including considerable contribution from the station secondary frequency standard), and rationalized with existing data. The variance model is definitely sound; the Allan technique mates theory and measure. The mean-frequency model is an estimate; this problem is yet to be rigorously resolved. The unaltered defining expressions are noncovergent, and the observed mean is quite erratic.

Bunce, R.↗

The effect of reducing dietary lipid and food availability on precocious male maturation in Chinook Salmon: A production-scale hatchery experiment

Abstract Objective Age of maturation in Chinook Salmon Oncorhynchus tshawytscha is phenotypically plastic, influenced by both genotype and environmental factors, including the availability and composition of the diet. Salmon hatchery programs often rear fish under accelerated growth regimes using high-lipid diets that can result in earlier age at maturity, including increased prevalence of age-2 males (minijacks). The goal of this investigation was to compare alternative dietary regimes to mitigate for this shift in age at maturity in hatchery-reared Umatilla River fall Chinook Salmon. Methods Juvenile fish were reared at Bonneville Hatchery, Oregon, under four dietary treatments across four replicate brood years. Dietary treatments included two feeding frequencies (standard [fed 7 days/week] and reduced [fed 4 days/week]) and two dietary lipid levels (standard [18%] and reduced [12%]) in a 2 × 2 factorial design. Dietary treatments were applied for approximately 9 months, beginning in March (a month after fry emergence) and lasting until December of the first year, after which all fish were reared on the standard feeding regime (7 days–18%) until the time of release the following spring as yearlings. Result We observed significant interannual variation in the proportion of minijacks produced among dietary treatments. For all brood years, decreasing the feeding frequency from 7 to 4 days/week reduced the proportion minijacks by 35.9%, and lowering dietary lipid from 18% to 12% reduced the proportion minijacks by 30%. The combined effects of reducing the feeding frequency and lowering dietary lipid were additive, reducing the proportion minijacks by 65.5% compared to the standard rearing regime. Growth and energetic indices were monitored throughout and confirmed findings from previous laboratory-based studies indicating that physiological status 10–12 months prior to spawn timing is important for the “decision” to mature. Conclusion Results of this investigation provide useful insights for optimizing rearing regimes for the Umatilla River program and other Chinook Salmon hatchery programs.

Harstad, Deborah L. (ORCID:0000000202676085)↗

Ion ring in a linear multipole trap for optical frequency metrology

A ring crystal of ions trapped in a linear multipole trap is studied as the basis for an optical frequency standard. The equilibrium conditions and cooling possibilities are discussed through an analytical model and molecular dynamics simulations. A configuration is proposed that reduces the frequency sensitivity to the fluctuations of the number of trapped ions. The systematic shifts for the electric quadrupole transition of calcium ions are evaluated for this ring configuration. This study shows that a ring of 10 or 20 ions allows a better short-term stability to be reached than for a single ion without introducing limiting long-term fluctuations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time and frequency requirement for the earth and ocean physics applications program

The application of time and frequency standards to the Earth and Ocean Physics Applications Program (EOPAP) is discussed. The goals and experiments of the EOPAP are described. Methods for obtaining frequency stability and time synchronization are analyzed. The orbits, trajectories, and characteristics of the satellites used in the program are reported.

Vonbun, F. O.↗

On Precision Measurement of the Frequency of the 1{sup 1}S–2{sup 3}S Forbidden Transition of a Helium Atom

The possibility is demonstrated of a precision frequency measurement for the 1{sup 1}S{sub 0}−2{sup 3}S{sub 1} forbidden transition (at 62.6 nm) of a helium atom using the stimulated Raman scattering method. The 1{sup 1}S{sub 0} singlet state is the ground state of {sup 4}He, while the metastable 2{sup 3}S{sub 1} state has the lowest energy in the triplet part of the spectrum ({sup 4}He*). The transition has a very small natural width, which allows us to consider it as a possible reference for creation of a frequency standard in the vacuum ultraviolet region.

74 ATOMIC AND MOLECULAR PHYSICS↗

The time and frequency comparisons via Loran-C and National TV Network in Yugoslavia

Time comparisons were made between cesium clocks in Yugoslavia and other cesium clocks in the country by the Laboratory of Federal Bureau of Measures and Precious Metals. Regional standard frequency and time signals dissemination is over National TV network by so called active TV system. International comparisons are performed via Loran-C system and by clock transportation. The method of calculation and approximation of the time signal propagation delays is given. Settled comparison results of the cesium clocks via TV network, Loran-C, and by clock transportation are also discussed in this paper.

Markovic, Z. M.↗

VLBI and GPS-based Time-Transfer Using CONT08 Data

One important prerequisite for geodetic Very Long Baseline Interferometry (VLBI) is the use of frequency standards with excellent short term stability. This makes VLBI stations, which are often co-located with Global Navigation Satellite System (GNSS) receiving stations, interesting for studies of time- and frequency-transfer techniques. We present an assessment of VLBI time-transfer based on the data of the two week long consecutive IVS CONT08 VLBI campaign by using GPS Carrier Phase (GPSCP). CONT08 was a 15 day long campaign in August 2008 that involved eleven VLBI stations on five continents. For CONT08 we estimated the worst case VLBI frequency link stability between the stations of Onsala and Wettzell to 1e-15 at one day. Comparisons with GPSCP confirm the VLBI results. We also identify time-transfer related challenges of the VLBI technique as used today.

Rieck, Carsten↗

Reference frequency transmission over optical fiber

A 100-MHz reference frequency from a hydrogen maser frequency standard has been transmitted via optical fiber over a 14-km distance with a measured stability of 1.5 X 10 to the-15 power for 1000 seconds averaging time. This capability was demonstrated in a frequency distribution experiment performed in April, 1986. The reference frequency was transmitted over a single-mode fiber-optic link from Deep Space Station (DSS) 13 to DSS 12 and back. The background leading up to the experiment and the significance of stable reference frequency distribution in the Deep Space Network (DSN) is discussed. Also described are the experiment, including the fiber-optic link, the measurement method and equipment, and finally the results of the experiment.

Lutes, G.↗

Progress Report for a New Cryogenic Sapphire Oscillator

We present design progress and subsystem test results for a new short-term frequency standard, the Voltage Controlled Sapphire Oscillator (VCSO). Included are sapphire resonator and coupling design, cryocooler environmental sensitivity tests, Q measurement results, and turnover temperature results. A previous report presented history of the design related to resonator frequency and frequency compensation [1]. Performance goals are a frequency stability of 1x10(exp -14) (1 second less than or equal to (tau) less than or equal to 100 seconds) and two years or more continuous operation. Long-term operation and small size are facilitated by use of a small Stirling cryo-cooler (160W wall power) with an expected 5 year life.

oscillator↗

Spacecraft Tests of General Relativity

Current spacecraft tests of general relativity depend on coherent radio tracking referred to atomic frequency standards at the ground stations. This paper addresses the possibility of improved tests using essentially the current system, but with the added possibility of a space-borne atomic clock. Outside of the obvious measurement of the gravitational frequency shift of the spacecraft clock, a successor to the suborbital flight of a Scout D rocket in 1976 (GP-A Project), other metric tests would benefit most directly by a possible improved sensitivity for the reduced coherent data. For purposes of illustration, two possible missions are discussed. The first is a highly eccentric Earth orbiter, and the second a solar-conjunction experiment to measure the Shapiro time delay using coherent Doppler data instead of the conventional ranging modulation.

Anderson, John D.↗

A low phase noise microwave frequency synthesis for a high-performance cesium vapor cell atomic clock

We report the development, absolute phase noise, and residual phase noise characterization of a 9.192 GHz microwave frequency synthesis chain devoted to be used as a local oscillator in a high-performance cesium vapor cell atomic clock based on coherent population trapping (CPT). It is based on frequency multiplication of an ultra-low phase noise 100 MHz oven-controlled quartz crystal oscillator using a nonlinear transmission line-based chain. Absolute phase noise performances of the 9.192 GHz output signal are measured to be −42, −100, −117 dB rad{sup 2}/Hz and −129 dB rad{sup 2}/Hz at 1 Hz, 100 Hz, 1 kHz, and 10 kHz offset frequencies, respectively. Compared to current results obtained in a state-of-the-art CPT-based frequency standard developed at LNE-SYRTE, this represents an improvement of 8 dB and 10 dB at f = 166 Hz and f = 10 kHz, respectively. With such performances, the expected Dick effect contribution to the atomic clock short term frequency stability is reported at a level of 6.2 × 10{sup −14} at 1 s integration time, that is a factor 3 higher than the atomic clock shot noise limit. Main limitations are pointed out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of trapped-ion heating on generalised Ramsey methods for suppressing frequency shifts caused by a probe field in atomic clocks

Based on a simple one-dimensional model, we consider the effect of trapped-ion heating on the efficiency of generalised Ramsey methods for the probe-induced frequency shift suppression in optical frequency standards based on single ultracold ions. It is shown that ion heating reduces the efficiency of all previously proposed one-loop generalised Ramsey methods, leading in all cases to the appearance of a linear dependence of the reference frequency shift on the residual field frequency shift. Two versions of the most heating stable generalised Ramsey schemes, for which the proportionality coefficient in this dependence is minimal, are demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser system for secondary cooling of {sup 87}Sr atoms

A laser system with a narrow generation line for secondary laser cooling of {sup 87}Sr atoms has been developed and investigated. It is planned to use ultracold {sup 87}Sr atoms loaded in an optical lattice in an optical frequency standard. To this end, a 689-nm semiconductor laser has been stabilised using an external reference ultrastable cavity with vibrational and temperature compensation near the critical point. The lasing spectral width was 80 Hz (averaging time 40 ms), and the frequency drift was at a level of 0.3 Hz s{sup -1}. Comparison of two independent laser systems yielded a minimum Allan deviation: 2 Multiplication-Sign 10{sup -14} for 300-s averaging. It is shown that this system satisfies all requirements necessary for secondary cooling of 87Sr atoms using the spectrally narrow {sup 1}S{sub 0} - {sup 3}P{sub 1} transition ({lambda} = 689 nm). (cooling of atoms)

74 ATOMIC AND MOLECULAR PHYSICS↗

Higher Pole Linear Traps for Atomic Clock Applications

We investigate experimentally and theoretically higher pole linear ion traps for frequency standard use. We have built a 12-pole trap and have successfully loaded ions into it from a linear quadrupole trap. By solving the Boltzmann equation describing large ion clouds where space charge interactions are important, we show that clock frequency changes due to ion number fluctuations are much smaller in ion clocks based multipole traps than comparable clocks based on quadrupole linear traps.

Prestage, John D.↗

Measurement of the power spectral density of phase of the hydrogen maser

Hydrogen masers are being developed for the Deep Space Network as improved frequency standards, in order to achieve better timing accuracies, reduced Doppler residuals, and lower phase noise in the tracking system. Performance data for the masers are given in two forms: time domain performance, useful for analyzing time keeping systems and Doppler systems; and frequency domain performance, useful for analyzing tracking systems. Particular attention is given to frequency domain performance, as obtained from both time domain measurements and direct measurements.

Sward, A.↗

Shuttle time and frequency transfer experiment

A proposed space shuttle experiment to demonstrate techniques for global high precision comparison of clocks and primary frequency standards is described. The experiment, using transmitted microwave and pulsed laser signals, compared a hydrogen maser clock onboard the space shuttle with a clock in a ground station in order to demonstrate time transfer with accuracies of 1 nsec or better and frequency comparison at the 10 to the -14th power accuracy level.

Allan, D. W.↗

Stabilized Photonic Links for Deep Space Tracking, Navigation, and Radio Science Applications

Stable fiber optic links have been operational in NASA's DSN for over 20 years providing distribution limited fractional frequency stability below 10-14 at one second and reaching 10-18 at approx 10,000 seconds. We summarize recent stabilized photonic link developments for DSN operation capable of high performance and reliability, and at much lower cost than previous systems. Recent research has focused on two applications, 1) actively stabilized links to transport 100 MHz metrology frequency references to sites up to 30 km from the central atomic frequency standard, and 2) stabilized links transporting broadband S, X, and Ka band signals used in deep space tracking and navigation and antenna arraying applications.

frequency distribution↗