Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Orbiting Deep Space Relay Station (ODSRS): DSN feasibility study report

Future tracking requirements and advantages over earth based stations justify the design of an orbiting, free flying very long base interferometry system to provide high resolution maps of celestial radio sources. Moderate technology development is required for the following: 30 meter to 60 meter diameter deployable parabolic antennas with less than 2 millimeters surface tolerance; a momentum wheel attitude control system with few arc/second accuracy; solar power design; a hydrogen maser atomic frequency standard; and the cryogenic receivers. The system must meet current Deep Space tracking capabilities as a minimum, and the technology must be compatible with system performance growth in the future. System lifetime must be ten years without major refurbishing.

Thornton, T.↗

Satellite Power System (SPS) international agreements

The problems in obtaining international agreements on geostationary orbit availability, microwave frequency allocations and microwave frequency standards for satellites transmitting solar power are considered. The various U.S. policy options, strategies and time frames with respect to key issues are analyzed.

Grove, S.↗

A modular multiple use system for precise time and frequency measurement and distribution

A modular CAMAC based system is described which was developed to meet a variety of precise time and frequency measurement and distribution needs. The system was based on a generalization of the dual mixer concept. By using a 16 channel 100 ns event clock, the system can intercompare the phase of 16 frequency standards with subpicosecond resolution. The system has a noise floor of 26 fs and a long term stability on the order of 1 ps or better. The system also used a digitally controlled crystal oscillator in a control loop to provide an offsettable 5 MHz output with subpicosecond phase tracking capability. A detailed description of the system is given including theory of operation and performance. A method to improve the performance of the dual mixer technique is discussed when phase balancing of the two input ports cannot be accomplished.

Reinhardt, V. S.↗

PTTI applications to deep space navigation

Radio metric deep space navigation relies nearly exclusively upon coherent, two way, Doppler and ranging for all precise applications. These data types and the navigational accuracies they can produce are reviewed. The deployment of hydrogen maser frequency standards and the development of Very Long Baseline Interferometry (VLBI) systems within the Deep Space Network are used in the development of non-coherent, one way data forms that promise much greater inherent navigational accuracy. The underlying structure between each data class and clock performance is charted. VLBI observations of the natural radio sources are the planned instrument for the synchronization task. This method and a navigational scheme using differential measurements between the spacecraft and nearby quasars are described.

Curkendall, D. W.↗

An improved storage bulb mount for DSN hydrogen masers

The presently used JPL hydrogen maser suspended atomic storage bulb and a rigid, single-plane mounted bulb are compared. The new bulb incorporates three major design changes: (1) mounting design; (2) alterations to the collimator; and (3) decrease in mass. These design changes are expected to increase the long-term stability of the frequency standard by reducing its sensitivity to vibration and thermal effects.

Dachel, P. R.↗

Phase and group delay calibration of a very long baseline interferometer by East Coast VLBI Group

Precisely timed pulses injected into the input of each receiver are used to calibrate the phase and group delay through each interferometer terminal. The short duration pulses are generated at a 1 MHz rate directly from the output of the frequency standard. The pulses are injected into the receiver at a level low enough to produce less than one percent increase in system temperature, yet can be extracted during processing with a high enough signal to noise ratio to determine the phase of the calibration rails within 1 degree in 1 second of integration. The calibration system also includes precise cable measurement electronics and a pulse echo for clock synchronization.

Rogers, A. E. E.↗

The performance of primary Cs beam clocks using quadrupole and hexapole deflection systems. Consequences for time keeping

Since 1978 the time-and-frequency standard CS1 of the Physikalisch-Technische Bundesanstalt (PTB) has operated continuously as a 'primary clock'. Its uncertainty (7.1 to the negative 15th power) is considerably smaller than that of the other existing primary standards. The CS1 is equipped with a combination of quadrupole and hexapole magnets and uses a longitudinal C-field. Consequences of utilizing primary clocks of this quality for the generation of the International Atomic Time Scale TAI are discussed.

Becker, G.↗

The LASSO experiment

An international coordinated experimental assessment of a system which promises to provide a synchronization of clocks bound to time and frequency standard laboratories, with an accuracy of one nanosecond using existing or near ground-based laser stations via a geostationary satellite (SIRIO-2) is detailed. The system performance and the technical details concerning the on-board equiment, the ground segment, and the operational configuration are discussed. Finally, the future prospects of the LASSO experiment and possible implementations are examined together.

Serene, B.↗

Demonstration of remote clock monitoring by VLBI with three baseline closures

The capability of very long baseline interferometry (VLBI) to monitor the stability of remotely located hydrogen maser frequency standards has been demonstrated by a series of experiments conducted between Deep Space Stations in Australia, Spain, and California. The measured stabilities of the clock systems, over approximately 10 day intervals, were 1 to 3 parts in 10 to the 13th power, with the instabilities due to the oscillators, the clock distribution systems, the receiving system delays, and the VLBI measurement error. Experiments were conducted independently using two different systems (BLOCK 0 and WBDAS). Later comparison shows agreement on the order of 1 part in 10 to the 13th power. Closure was demonstrated on three separate occasions to 33, 10, and 13 ns with an error uncertainty of + or - 42 ns. The results represent an important consistency check on VLBI measurements.

Cheetham, C. M.↗

Signal to noise ratio calculation for fiber optics links

The signal to noise ratio (SNR) effect upon the maximum transmission length of a fiberoptic system is discussed. The relationships of different system parameters are discussed. A general formula to obtain the SNR of a single mode fiberoptic system is derived. The SNR attainable with single mode and multimode fiber optics links was calculated from fundamental noise considerations. It was found that for single mode fibers, laser noise dominates the noise contributions for links less than 30 km long, while thermal noise dominates for longer links. Multimode fibers degrade SNR for long links because of intermode dispersion. For frequency standard transmission, as long as the baseband modulation signals are within the bandwidth of the fibers, respectable SNR can be attained with low loss fibers (approximately 1 dB/km) for links as long as 70 km. For wideband transmission SNR is decreased by a factor equal to the ratio of the bandwidth.

Lau, K. Y.↗

Precise Phase Comparator for Nearly Equal Frequencies

New circuit precisely compares phases of two RF signals nearly equal in frequency, such as two hydrogen-maser frequency standards. Measuring circuit minimizes interactions between two sources. Also stabilized against thermal effects and against noise that could produce erroneous readings. Heat sinking, buffer amplifiers, and low-noise zero-crossing detector make picosecond precision possible.

Reinhardt, V. S.↗

Precise RF timing signal distribution to remote stations

A method and apparatus are disclosed for distributing a stable reference frequency from a hydrogen maser frequency standard, or similar RF source, to remote stations over great distances with very good phase stability, and with constant amplitude, at each distribution point using a light beam carrier. A technique for providing automatic gain control at an optical receiver with phase stability in the RF reference is provided.

Lutes, G. F.↗

Government and industry interactions in the development of clock technology

It appears likely that everyone in the time and frequency community can agree on goals to be realized through the expenditure of resources. These goals are the same as found in most fields of technology: lower cost, better performance, increased reliability, small size and lower power. Related aspects are examined in the process of clock and frequency standard development. Government and industry are reviewed in a highly interactive role. These interactions include judgements on clock performance, what kind of clock, expenditure of resources, transfer of ideas or hardware concepts from government to industry, and control of production. Successful clock development and production requires a government/industry relationship which is characterized by long-term continuity, multidisciplinary team work, focused funding and a separation of reliability and production oriented tasks from performance improvement/research type efforts.

Hellwig, H.↗

The SA-2239/WLQ-4(V) Cutty Sark distribution system

A redundant frequency and time distribution system provides a multiplicity of isolated outputs, all of which are derived from three atomic frequency standards. The distribution system monitors input parameters of the signals coming from the Cesium Standards and selects one to be the primary standard, phase locks an internal oscillator which has excellent aging characteristics in the open loop mode and acts as a filter to provide phase noise improvement, and generates 1 megahertz and 100 kHz by direct synthesis. Additionally, the system distributes RF and timing signals consisting of 5 MHz, 1 MHz, 100 kHz, BCD Time-of-Day, 1 pps and 1 ppm.

Vulcan, A.↗

The impact of WARC-79 on space applications

It is pointed out that the decisions of WARC-79 are crucial to the future utility of applications evolving from research and development of space techniques. WARC-79 provided the spectrum allocations and protection which will permit continued development of a broad range of space applications. Space research and earth-exploration satellite services are discussed, taking into account remote sensing, spectrum requirements, implications for designers and regulators, and space research and earth exploration satellite services. Meteorological satellites are considered along with search-and-rescue operations, standard frequency and time satellites, the search for extraterrestrial intelligence, and the solar-power satellite. The WARC rejected a U.S. allocation proposal for the solar-power satellite on the basis that the proposal was premature because spectrum, biological, and ecological impacts have not yet been fully examined.

Kiebler, J. W.↗

A rubidium clock for GPS

The design objectives and approach; the more important design features; the signal parameters and error budget; and early test results in the development of a second-source rubidium frequency standard for use in the GPS navigation satellites are discussed. Tests of a breadboard version of the RFS show that the measured time-domain stability is within the goal specification. The results are uncorrected for the conribution of the reference and are probably limited by the reference stability in the medium term region. The Rb reference is bbetter in the medium term region, but the Cs reference is etter at 10,000 seconds and longer, probably because of the barometric sensitivity of the rubidium reference unit.

Riley, W. J.↗

Satellite time and frequency transfer (STIFT)

The concept of placing a hydrogen maser high stability clock in Earth orbit to provide accurate time and frequency comparisons worldwide to major timing centers and to a large number of radio observatory antenna sites involved in VLBI measurements was studied. The proposal was chiefly directed toward studies and initial hardware designs for time comparisons between hydrogen maser frequency standards and to modifications of the hydrogen maser for long-term use in space.

Vessot, R. F. C.↗