Neutron-emission measurements at a white neutron source
Abstract Not Provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
High sensitivity radio searches of unassociated γ-ray sources have proven to be an effective way of finding new pulsars. Using the Five-hundred-meter Aperture Spherical radio Telescope (FAST) during its commissioning phase, we have carried out a number of targeted deep searches of Fermi Large Area Telescope (LAT) γ-ray sources. On February 27, 2018 we discovered an isolated millisecond pulsar (MSP), PSR J0318+0253, coincident with the unassociated γ-ray source 3FGL J0318.1+0252. PSR J0318+0253 has a spin period of 5.19 ms, a dispersion measure (DM) of 26 pc cm−3 corresponding to a DM distance of about 1.3 kpc, and a period-averaged flux density of (∼11±2) µJy at L-band (1.05–1.45 GHz). Among all high energy MSPs, PSR J0318+0253 is the faintest ever detected in radio bands, by a factor of at least ∼4 in terms of L-band fluxes. With the aid of the radio ephemeris, an analysis of 9.6 years of Fermi-LAT data revealed that PSR J0318+0253 also displays strong γ-ray pulsations. Follow-up observations carried out by both Arecibo and FAST suggest a likely spectral turn-over around 350 MHz. This is the first result from the collaboration between FAST and the Fermi-LAT teams as well as the first confirmed new MSP discovery by FAST, raising hopes for the detection of many more MSPs. Such discoveries will make a significant contribution to our understanding of the neutron star zoo while potentially contributing to the future detection of gravitational waves, via pulsar timing array (PTA) experiments.
The detection of coherent X-ray pulsations at ∼314 Hz (3.2 ms) classifies MAXI J1957+032 as a fast-rotating, accreting neutron star. We present the temporal and spectral analysis performed using NICER observations collected during the latest outburst of the source. Doppler modulation of the X-ray pulsation revealed the ultra-compact nature of the binary system characterized by an orbital period of ∼1 h and a projected semimajor axis of 14 lt-ms. The neutron star binary mass function suggests a minimum donor mass of 1.7 × 10 −2 M ⊙ , assuming a neutron star mass of 1.4 M ⊙ and a binary inclination angle lower than 60 deg. This assumption is supported by the lack of eclipses or dips in the X-ray light curve of the source. We characterized the 0.5–10 keV energy spectrum of the source in outburst as the superposition of a relatively cold black-body-like thermal emission compatible with the emission from the neutron star surface and a Comptonization component with photon index consistent with a typical hard state. We did not find evidence for iron K α lines or reflection components.
• In Neutron shielding, neutron energy is the primary determinant of shield characteristics. • Fast Neutrons (E ≥1 MeV) must first me thermalized with high neutron scattering materials. • These thermal neutrons can then be absorbed or shielded with high cross sections for neutron absorption. • Rain-gauges, which utilize principles of nucleic detection, operate with thermal neutron detectors. • Systems such as He-3 detectors measure rain by correlating neutron moderation with rain level. • From this relationship its possible to determine unknown levels of substance with a known detector signal strength.
The Neutron Imaging System has proven to be an important diagnostic in studying DT implosion characteristics at the National Ignition Facility. Here, the current system depends on a polystyrene scintillating fiber array, which detects fusion neutrons born in the DT hotspot as well as neutrons that have scattered to lower energies in the surrounding cold fuel. Increasing neutron yields at NIF, as well as a desire to resolve three-dimensional information about the fuel assembly, have provided the impetus to build and install two additional next-generation neutron imaging systems. We are currently investigating a novel neutron imaging system that will utilize a deuterated polystyrene (CD) fiber array instead of standard hydrogen-based polystyrene (CH). Studies of deuterated xylene or deuterated benzene liquid scintillator show an improvement in imaging resolution by a factor of two, but also a reduction in light output as compared to standard plastic. Tests of the relative light output of deuterated polystyrene and standard polystyrene were completed using 14 MeV fusion neutrons generated through implosions of deuterium-tritium filled capsules at the OMEGA laser facility. In addition, we collected data of the relative response of these two scintillators to a wide energy range of neutrons (1-800 MeV) at the Weapons Neutrons Research Facility. Results of these measurements are presented.
The large majority of neutron stars (NSs) in low-mass X-ray binaries (LMXBs) have never shown detectable pulsations despite several decades of intense monitoring. The reason for this remains an unsolved problem that hampers our ability to measure the spin frequency of most accreting NSs. The accreting millisecond X-ray pulsar (AMXP) HETE J1900.1-2455 is an intermittent pulsar that exhibited pulsations at about 377 Hz for the first two months and then turned into a nonpulsating source. Understanding why this happened might help us to understand why most LMXBs do not pulsate. We present a seven-year coherent timing analysis of data taken with the Rossi X-ray Timing Explorer. We discover new sporadic pulsations that are detected on a baseline of about 2.5 years. We find that the pulse phases anti-correlate with the X-ray flux as previously discovered in other AMXPs. We place stringent upper limits of 0.05% rms on the pulsed fraction when pulsations are not detected and identify an enigmatic pulse phase drift of {approx}180 Degree-Sign in coincidence with the first disappearance of pulsations. Thanks to the new pulsations we measure a long term spin frequency derivative whose strength decays exponentially with time. We interpret this phenomenon as evidence of magnetic field burial.
The scintillation properties of Ce-activated alkali-lutetium double phosphate single crystals that vary with the alkali ion type and activation level are summarized and compared. The materials investigated here have been identified as fast and efficient scintillators for the detection of x-ray and radiation, and in case of Li3Lu(PO4)2:Ce, for thermal neutron detection as well.
In this work, a 'fission electron-collection' neutron detector was studied using the Monte Carlo method. The detector consists of two metal electrodes mounted in a vacuum, named coated and collection electrodes, respectively. The first electrode is coated with triuranium octoxide. The detector uses the 'fission electron-collection' technique, which does not need an intermediate material but directly collects electrons from the coating. Such a detector can realize a flat energy response and a fast time response, both of which are important in the fluence measurement of pulsed neutron sources. In this paper, the physical processes of detection are presented, as well as Monte Carlo simulation studies using the Geant4 toolkit. From the results, the sensitivity of the detector is approximately 1.5 x 10{sup -21} [C/(n/cm{sup 2})], and the FWHM of response function is 2.5 nanoseconds. Additionally, the characterization of escaping electrons is also presented, and the sensitivity of the detector is determined for various coating thicknesses. (authors)
Sixteen Medipix2 pixel detector based (MPX) devices were operated at various positions within the ATLAS detector and cavern continuously from early 2008 up to 2013. In addition to photons, each MPX detector is capable to detect charged particles, and neutrons as it is covered with a mask of converter materials dividing its area into regions sensitive to thermal or fast neutrons. The MPX detector network was effectively used for real-time measurements of the spectral characteristics and composition of complex radiation fields in ATLAS. This article reports comparison of the results of measurements performed with MPX detectors during the LHC operation period in 2010 and 2011 with Monte Carlo simulations results from the FLUGG and GCALOR codes. For the purpose of this comparison, the MPX detectors were operated in tracking mode with low threshold (8–10 keV) allowing one to distinguish among particle categories based on the recognition of track patterns left by the particles in the MPX sensitive layer. The comparison of measurements with simulations shows that the agreement between measured and simulated data is satisfactory in most cases within a factor of two.
This article reports an improved independent measurement of neutrino mixing angle θ 13 at the Daya Bay Reactor Neutrino Experiment. Electron antineutrinos were identified by inverse β-decays with the emitted neutron captured by hydrogen, yielding a data set with principally distinct uncertainties from that with neutrons captured by gadolinium. With the final two of eight antineutrino detectors installed, this study used 621 days of data including the previously reported 217-day data set with six detectors. The dominant statistical uncertainty was reduced by 49%. Intensive studies of the cosmogenic muon-induced 9 Li and fast neutron backgrounds and the neutron-capture energy selection efficiency, resulted in a reduction of the systematic uncertainty by 26%. The deficit in the detected number of antineutrinos at the far detectors relative to the expected number based on the near detectors yielded sin 2 2θ 13 = 0.071 ± 0.011 in the three-neutrino-oscillation framework. As a result, the combination of this result with the gadolinium-capture result is also reported.
We present Clusterrank, a new algorithm for identifying dispersed astrophysical pulses. Such pulses are commonly detected from Galactic pulsars and rotating radio transients (RRATs), which are neutron stars with sporadic radio emission. More recently, isolated, highly dispersed pulses dubbed fast radio bursts (FRBs) have been identified as the potential signature of an extragalactic cataclysmic radio source distinct from pulsars and RRATs. Clusterrank helped us discover 14 pulsars and 8 RRATs in data from the Arecibo 327 MHz Drift Pulsar Survey (AO327). The new RRATs have DMs in the range 23.5–86.6 pc cm{sup −3} and periods in the range 0.172–3.901 s. The new pulsars have DMs in the range 23.6–133.3 pc cm{sup −3} and periods in the range 1.249–5.012 s, and include two nullers and a mode-switching object. We estimate an upper limit on the all-sky FRB rate of 10{sup 5} day{sup −1} for bursts with a width of 10 ms and flux density ≳83 mJy. The DMs of all new discoveries are consistent with a Galactic origin. In comparing statistics of the new RRATs with sources from the RRATalog, we find that both sets are drawn from the same period distribution. In contrast, we find that the period distribution of the new pulsars is different from the period distributions of canonical pulsars in the ATNF catalog or pulsars found in AO327 data by a periodicity search. This indicates that Clusterrank is a powerful complement to periodicity searches and uncovers a subset of the pulsar population that has so far been underrepresented in survey results and therefore in Galactic pulsar population models.
An instrument that will directly image the fast fission neutrons from a special nuclear material source has been described. This instrument can improve the signal to background compared to non imaging neutron detection techniques by a factor given by ratio of the angular resolution window to 4.pi.. In addition to being a neutron imager, this instrument will also be an excellent neutron spectrometer, and will be able to differentiate between different types of neutron sources (e.g. fission, alpha-n, cosmic ray, and D-D or D-T fusion). Moreover, the instrument is able to pinpoint the source location.
We present the results of analysis of triton burn-up process using the data from diamond detector. Neutron monitor based on CVD diamond was installed in JET torus hall close to the plasma center. We measure the part of 14 MeV neutrons in scenarios where plasma current varies in a range of 1-3 MA. In this experiment diamond neutron monitor was also able to detect strong gamma bursts produced by runaway electrons arising during the disruptions. We can conclude that CVD diamond detector will contribute to the study of fast particles confinement and help predict the disruption events in future tokamaks.
For the fission neutron spectrum measurement, the neutron energy is determined in a time-of-flight experiment by the time difference between the fission event and detection of the neutron. Therefore, the neutron energy resolution is directly determined by the time resolution of both neutron and fission detectors. For the fission detection, the detector needs not only a good timing response but also the tolerance of radiation damage and high {alpha}-decay rate. A parallel-plate avalanche counter (PPAC) has many advantages for the detection of heavy charged particles such as fission fragments. These include fast timing, resistance to radiation damage, and tolerance of high counting rate. A PPAC also can be tuned to be insensitive to particles, which is important for experiments with - emitting actinides. Therefore, a PPAC is an ideal detector for experiments requiring a fast and clean trigger for fission. In the following sections, the description will be given for the design and performance of a new low-mass PPAC for the fission-neutron spectrum measurements at LANL.
We present the design and performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20-30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8 0.5% of the true value. Finally, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5-10% level for a two hour scan time. Experimental performance was evaluated with various thicknesses of polyethylene. The detector response in terms of energy, particle identification, and timing are presented as well.
A brief analysis is given of the modern instrumental methods of monitoring the ash content of coal. Their particulars and drawbacks are examined. A neutron gamma-method of monitoring the ash content is proposed on the basis of integrated use of prompt γ-radiation accompanying inelastic scattering of fast neutrons and radiative capture of thermal neutrons by nuclei of the primary elements comprising the organic and mineral components of coal. The instrumental-methodological parameters of monitoring (sizes of the analyzed samples, energy intervals of the detected gamma radiation) making it possible to the increase the sensitivity of the method with respect to the ash content and to minimize the impact of the variability of the moisture content of coal on its material composition, are optimized. The method has been certified and recommended for representative monitoring of the quality of coarse coal.
Results are presented from experimental studies of the plasma formation dynamics in a Z-pinch produced from a cylindrical microporous agar-agar load. The experiments were performed on the S-300 facility at a current of 2 MA and current rise time of 100 ns. To enhance the energy concentration, a deuterated polyethylene neck with a mass density of 50-75 {mu}g/cm{sup 3} and diameter of 1-2 mm was made in the central part of the load. The spatiotemporal characteristics of the Z-pinch were studied using an optical streak camera and fast frame photography in the optical and soft X-ray spectral ranges. X-ray emission was detected using semiconductor and vacuum diodes, and neutron emission was studied by means of the time-of-flight method. It is found that, in the course of continuous plasma production, hot spots with a diameter of 100 {mu}m form in the pinch plasma. The hot spots emit short soft X-ray pulses with a duration of 2-4 ns, as well as neutron pulses with an average neutron energy of about 2.45 MeV. The maximum neutron yield was found to be 4.5 x 10{sup 9} neutrons per shot. The scenario of hot spot formation is adequately described by two-dimensional MHD simulations.
The subcritical reactivity, ρ, of a neutron multiplying system is of interest to many factions of the nuclear community. The subcritical reactivity in a nuclear system can be inferred from measurements of the prompt neutron decay constant, α. Near critical, the reactivity is linearly proportional with α, but the linearity between these quantities does not hold in systems with low multiplication or significantly above prompt critical. This work examines a large range of subcritical prompt neutron decay constant measurements on a thermal HEU metal system. This system is designed to mimic a solution system and to have the optimal H/ 235 U ratio to minimize the critical mass. The reactivity of these measurements varies between 0$\$$ and 70$\$$ below critical. In addition to experimental measurements on the thermal system, simulations are performed on both the thermal HEU system and a fast HEU metal system. Both the fast and thermal results are compared to baseline simulations performed using criticality eigenvalue (KCODE) mode in MCNP®6.2. These simulations are used for comparisons on the linearity between α and ρ. Prompt neutron decay constant measurements in this work are performed using the Rossi-α method. The measurements are taken using a 3 He neutron detection system and a Los Alamos National Laboratory designed list-mode data acquisition system. A specially designed computer program determines α from list-mode data. The α-eigenvalue, or α at delayed critical, for the thermal HEU system is -199:4±4:4 s -1 as measured during this work. The α-eigenvalue for the fast HEU system was previously measured to be -8:5 x 10 -5 s -1 . The results from the thermal HEU system study suggest that the relationship between ρ and α is linear when k eff > 0:80 based on the simulation results. The experimental results also agree with this result, but have less fidelity. No experimental results are available for the fast HEU system.