Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Assessment of Testing Options for the NTR at the INL (Final Report)

One of the main technologies that can be developed to dramatically enhance the human exploration of space is the nuclear thermal rocket (NTR). Several studies over the past thirty years have shown that the NTR can reduce the cost of a lunar outpost, reduce the risk of a human mission to Mars, enable fast transits for most missions throughout the solar system, and reduce the cost and time for robotic probes to deep space. Three separate committees of the National Research Council of the National Academy of Sciences have recommended that NASA develop the NTR. One of the primary issues in development of the NTR is the ability to verify a flight ready unit. Three main methods can be used to validate safe operation of a NTR: 1) Full power, full duration test in an above ground facility that scrubs the rocket exhaust clean of any fission products; 2) Full power , full duration test using the Subsurface Active Filtering of Exhaust (SAFE) technique to capture the exhaust in subsurface strata; 3) Test of the reactor fuel at temperature and power density in a driver reactor with subsequent first test of the fully integrated NTR in space. The first method, the above ground facility, has been studied in the past. The second method, SAFE, has been examined for application at the Nevada Test Site. The third method relies on the fact that the Nuclear Furnace series of tests in 1971 showed that the radioactive exhaust coming from graphite based fuel for the NTR could be completely scrubbed of fission products and the clean hydrogen flared into the atmosphere. Under funding from the MSFC, the Center for Space Nuclear Research (CSNR) at the Idaho National laboratory (INL) has completed a reexamination of Methods 2 and 3 for implementation at the INL site. In short, the effort performed the following: 1) Assess the geology of the INL site and determine a location suitable SAFE testing; 2) Perform calculations of gas transport throughout the geology; 3) Produce a cost estimate of a non-nuclear , sub-scale test using gas injection to validate the computational models; 4) Produce a preliminary cost estimate to build a nuclear furnace equivalent facility to test NTR fuel on a green field location on the INL site. The results show that the INL geology is substantially better suited to the SAFE testing method than the NTS site. The existence of impermeable interbeds just above the sub-surface aquifer ensure that no material from the test, radioactive or not, can enter the water table. Similar beds located just below the surface will prevent any gaseous products from reaching the surface for dispersion. The extremely high permeability of the strata between the interbeds allows rapid dispersion of the rocket exhaust. In addition, the high permeability suggests that a lower back-pressure may develop in the hole against the rocket thrust, which increases safety of operations. Finally, the cost of performing a sub-scale, non-nuclear verification experiment was determined to be $\$$3M. The third method was assessed through discussions with INL staff resident at the site. In essence, any new Category I facility on any DOE site will cost in excess of $\$$250M. Based on the results of this study, a cost estimate for testing a nuclear rocket at the INL site appears to be warranted. Given the fact that a new nuclear fuel may be possible that does not release any fission products, the SAFE testing option appears to be the most affordable.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technical Assistance for Characterization Studies of Personal Protection Equipment (PPE) (Final CTAP Report)

Sandia National Laboratories (SNL) conducted an independent assessment of three different certified N95 respirators for the State of New Mexico Department of Homeland Security and Emergency Management. The testing conducted under this effort mimicked traditional NIOSH certification testing methodologies, where possible (NIOSH 2019). This included the use of a commercially available off-the-shelf (COTS) instrument typically used in industry for N95 respirator certification (ATI 2018). The COTS system, an Air Techniques International 100Xs automated filter tester, was used for all the testing reported in this document. It is important to note that SNL is NOT a certification laboratory, and all quantitative results are for informational purposes only. Additional technical information of N95-related efforts conducted by this team may be found in: Omana et al. (2020a), Omana et al. (2020b), Celina et al. (2020)

42 ENGINEERING↗

Integrated Approach to Investigating Historic Cemeteries

Ground-penetrating radar (GPR) and terrestrial laser scanning (TLS) surveys were conducted at a historic cemetery at Cape Canaveral Air Force Station, Florida, U.S., in order to confirm the presence of burials corresponding to grave markers and detect potential unmarked burials. Noise in the GPR data from surface features and subtle terrain differences must be addressed to determine the extent of anomalies of interest. We use singular value decomposition (SVD) to isolate and remove energy from GPR data. SVD allows one to remove unwanted signals that traditional processing techniques cannot. With SVD filtering, we resolve an anomaly adjacent to confirmed burials otherwise overprinted by unwanted signal. The migration of SVD-filtered data produces more distinct, spatially constrained point reflectors. Ground elevation is derived from georeferenced TLS data and compared to that from airborne laser scanning (ALS) to highlight subtle terrain that can assist data interpretation. TLS elevations show a subtle modern mound over the burial plot where ALS elevations show a depression. The targets of interest are approximately 20–30 cm higher in elevation if a topographic correction is performed using TLS versus ALS. In archaeological applications, a notable change is often recorded at the sub-meter scale. The combined approach presented here better resolves geophysical response of buried features and their positions in the ground relative to each other.

Downs, Christine (ORCID:0000000237229381)↗

A Visual Analytics Approach for Correlation, Classification, and Regression Analysis

New approaches that combine the strengths of humans and machines are necessary to equip analysts with the proper tools for exploring today s increasing complex, multivariate data sets. In this paper, a visual data mining framework, called the Multidimensional Data eXplorer (MDX), is described that addresses the challenges of today s data by combining automated statistical analytics with a highly interactive parallel coordinates based canvas. In addition to several intuitive interaction capabilities, this framework offers a rich set of graphical statistical indicators, interactive regression analysis, visual correlation mining, automated axis arrangements and filtering, and data classification techniques. This chapter provides a detailed description of the system as well as a discussion of key design aspects and critical feedback from domain experts.

Steed, Chad A↗

Mechanical cutting of irradiated reactor internal components

Mechanical cutting methods to volume reduce and package reactor internal components are now a viable solution for stakeholders challenged with the retirement of first generation nuclear facilities. The recent completion of the removal of the Reactor Vessel Internals (RVI) from within the Sacramento Municipal Utility District's (SMUD) Rancho Seco Nuclear Power Plant demonstrates that unlike previous methods, inclusive of plasma arc and abrasive water-jet cutting, mechanical cutting minimizes exposure to workers, costly water cleanup, and excessive secondary waste generation. Reactor internal components were segmented, packaged, and removed from the reactor building for shipment or storage, allowing the reactor cavity to be drained and follow-on reactor segmentation activities to proceed in the dry state. Area exposure rates at the work positions during the segmentation process were generally 1 mR per hr. Radiological exposure documented for the underwater segmentation processes totaled 13 person rem. The reactor internals weighing 343,000 pounds were segmented into over 200 pieces for maximum shipping package efficiency and produced 5,600 lb of stainless steel chips and shavings which were packaged in void spaces of existing disposal containers, therefore creating no additional disposal volume. Because no secondary waste was driven into suspension in the reactor cavity water, the water was free released after one pass through a charcoal bed and ion exchange filter system. Mechanical cutting techniques are capable of underwater segmentation of highly radioactive components on a large scale. This method minimized radiological exposure and costly water cleanup while creating no secondary waste.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Wavelet Denoising of Mobile Radiation Data

The FY08 phase of this project investigated the merits of video fusion as a method for mitigating the false alarms encountered by vehicle borne detection systems in an effort to realize performance gains associated with wavelet denoising. The fusion strategy exploited the significant correlations which exist between data obtained from radiation detectors and video systems with coincident fields of view. The additional information provided by optical systems can greatly increase the capabilities of these detection systems by reducing the burden of false alarms and through the generation of actionable information. The investigation into the use of wavelet analysis techniques as a means of filtering the gross-counts signal obtained from moving radiation detectors showed promise for vehicle borne systems. However, the applicability of these techniques to man-portable systems is limited due to minimal gains in performance over the rapid feedback available to system operators under walking conditions. Furthermore, the fusion of video holds significant promise for systems operating from vehicles or systems organized into stationary arrays; however, the added complexity and hardware required by this technique renders it infeasible for man-portable systems.

07 ISOTOPE AND RADIATION SOURCES↗

Total skin electron beam therapy using an inclinable couch on motorized table and a compensating filter

Total skin electron beam is a specialized technique that involves irradiating the entire skin from the skin surface to only a few millimetres in depth. In the Stanford technique, the patient is in a standing position and six different directional positions are used during treatment. Our technique uses large electron beams in six directions with an inclinable couch on motorized table and a compensating filter was also used to spread the electron beam and move its intensity peak. Dose uniformity measurements were performed using Gafchromic films which indicated that the surface dose was 2.04 ± 0.05 Gy. This technique can ensure the dose reproducibility because the patient is fixed in place using an inclinable couch on a motorized table.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission gas bubble identification using MATLAB's image processing toolbox

Automated image processing routines have the potential to aid in the fuel performance evaluation process by eliminating bias in human judgment that may vary from person-to-person or sample-to-sample. This study presents several MATLAB based image analysis routines designed for fission gas void identification in post-irradiation examination of uranium molybdenum (U–Mo) monolithic-type plate fuels. Frequency domain filtration, enlisted as a pre-processing technique, can eliminate artifacts from the image without compromising the critical features of interest. This process is coupled with a bilateral filter, an edge-preserving noise removal technique aimed at preparing the image for optimal segmentation. Adaptive thresholding proved to be the most consistent gray-level feature segmentation technique for U–Mo fuel microstructures. The Sauvola adaptive threshold technique segments the image based on histogram weighting factors in stable contrast regions and local statistics in variable contrast regions. Once all processing is complete, the algorithm outputs the total fission gas void count, the mean void size, and the average porosity. The final results demonstrate an ability to extract fission gas void morphological data faster, more consistently, and at least as accurately as manual segmentation methods. - Highlights: •Automated image processing can aid in the fuel qualification process. •Routines are developed to characterize fission gas bubbles in irradiated U–Mo fuel. •Frequency domain filtration effectively eliminates FIB curtaining artifacts. •Adaptive thresholding proved to be the most accurate segmentation method. •The techniques established are ready to be applied to large scale data extraction testing.

36 MATERIALS SCIENCE↗

Lowering Whole-Body Radiation Doses in Pediatric Intensity-Modulated Radiotherapy Through the Use of Unflattened Photon Beams;Flattening filter; Pediatric; Intensity-modulated radiotherapy; Second cancers; Radiation-induced malignancies

Purpose: Intensity modulated radiotherapy (IMRT) has been linked with an increased risk of secondary cancer induction due to the extra leakage radiation associated with delivery of these techniques. Removal of the flattening filter offers a simple way of reducing head leakage, and it may be possible to generate equivalent IMRT plans and to deliver these on a standard linear accelerator operating in unflattened mode. Methods and Materials: An Elekta Precise linear accelerator has been commissioned to operate in both conventional and unflattened modes (energy matched at 6 MV) and a direct comparison made between the treatment planning and delivery of pediatric intracranial treatments using both approaches. These plans have been evaluated and delivered to an anthropomorphic phantom. Results: Plans generated in unflattened mode are clinically identical to those for conventional IMRT but can be delivered with greatly reduced leakage radiation. Measurements in an anthropomorphic phantom at clinically relevant positions including the thyroid, lung, ovaries, and testes show an average reduction in peripheral doses of 23.7%, 29.9%, 64.9%, and 70.0%, respectively, for identical plan delivery compared to conventional IMRT. Conclusions: IMRT delivery in unflattened mode removes an unwanted and unnecessary source of scatter from the treatment head and lowers leakage doses by up to 70%, thereby reducing the risk of radiation-induced second cancers. Removal of the flattening filter is recommended for IMRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-Intrusive Measurements Using Femtosecond Laser in Atmospheric Pressure Plasma Jet

Femto-second (fs) lasers offer state-of-the art non-intrusive diagnostic capabilities in plasma flow environments. The diagnostics in plasma flows using a fs-laser that are relevant to this proposal include Two-photon Absorption Laser Induced Fluorescence (TALIF) for measuring the number density of an atomic species, and Femto-second Laser Electronic Excitation Tagging (FLEET) for performing velocity measurements in plasma flows. Various aspects of these diagnostics using fs-lasers are still an active domain of research. The TALIF technique has been used to measure the number density of atomic species in various plasma flow environments like atmospheric pressure plasma jet (APPJ) and arc-jet flows. This technique utilizes a fs-laser to excite an atomic species and the subsequent relaxation process through fluorescence is recorded to make measurements. A narrow band-pass filter is used to isolate the fluorescence signal that is in the infra-red regime. However, broad-band background emissions can potentially pass through the filter and induce noise in the TALIF signal. Particularly, arc-jet plasma flows inherently contain background emissions. In such plasma flow environments, in addition to the filter, the background-subtraction technique will play an important role in reducing the noise that is induced in the number density measurements using TALIF. The proposed research focuses on evaluating the effectiveness of a background-subtraction technique by measuring atomic oxygen using a femtosecond (fs) TALIF in APPJ with induced background emissions and comparing measurements obtained without inducing the emissions. Therefore, by quantifying the changes in the signal-to-noise ratio caused by a background-subtraction technique applied for APPJ, it will enable a better understanding of the uncertainties in the background subtracted fs-TALIF measurements for arc-jet plasma flows. In addition to this, FLEET will be used to obtain velocity in the APPJ, and the impact of background emissions will be analyzed. Under this effort, the experimenters and research personnel will gain the technical know-how in the operational and theoretical aspects of the advanced fs-laser-based diagnostic techniques. The knowledge gained in this process will then also directly be applied to a separate ONR funded project at the Aerodynamics Research Center (ARC), UT Arlington, related to arc-jet flow characterization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial filtering with photonic crystals

Photonic crystals are well known for their celebrated photonic band-gaps—the forbidden frequency ranges, for which the light waves cannot propagate through the structure. The frequency (or chromatic) band-gaps of photonic crystals can be utilized for frequency filtering. In analogy to the chromatic band-gaps and the frequency filtering, the angular band-gaps and the angular (spatial) filtering are also possible in photonic crystals. In this article, we review the recent advances of the spatial filtering using the photonic crystals in different propagation regimes and for different geometries. We review the most evident configuration of filtering in Bragg regime (with the back-reflection—i.e., in the configuration with band-gaps) as well as in Laue regime (with forward deflection—i.e., in the configuration without band-gaps). We explore the spatial filtering in crystals with different symmetries, including axisymmetric crystals; we discuss the role of chirping, i.e., the dependence of the longitudinal period along the structure. We also review the experimental techniques to fabricate the photonic crystals and numerical techniques to explore the spatial filtering. Finally, we discuss several implementations of such filters for intracavity spatial filtering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Channel Estimation for Filter Bank Multicarrier Systems in Low SNR Environments

Channel estimation techniques are crucial for reliable communications. This paper is concerned with channel estimation in a filter bank multicarrier spread spectrum (FBMCSS) system. We explore two channel estimator options: (i) a method that makes use of a periodic preamble and mimics the channel estimation techniques that are widely used in OFDM-based systems; and (ii) a method that stays within the traditional realm of filter bank signal processing. For the case where the channel noise is white, both methods are analyzed in detail and their performance is compared against their respective Cramer-Rao Lower Bounds (CRLB). Advantages and disadvantages of the two methods under different channel conditions are given to provide insight to the reader as to when one will outperform the other.

99 GENERAL AND MISCELLANEOUS↗

Additively Manufactured Interdigital Filters for Ultra- Wideband Radar

Abstract— In this paper, we present the development of ultrawideband (UWB) inter-digital cavity filters manufactured with an additive technique. We employed a selective laser melting process with stainless steel via a “flipping and fixturing” approach to achieve dimensional accuracy and frequency selectivity (no postfabrication tuning) comparable to that of conventional micromachining. The filters operate at a center frequency of 3.75 GHz and 6 GHz, respectively, with an instantaneous bandwidth of 2 GHz. This paper presents design and fabrication details, a discussion of measured characteristics for both filters, and a performance comparison with respect to subtractively manufactured parts.

Keywords— Interdigital filters, UWB radar, additiv↗

SU-E-I-37: Low-Dose Real-Time Region-Of-Interest X-Ray Fluoroscopic Imaging with a GPU-Accelerated Spatially Different Bilateral Filtering

Purpose: The purpose of our study is to reduce imaging radiation dose while maintaining image quality of region of interest (ROI) in X-ray fluoroscopy. A low-dose real-time ROI fluoroscopic imaging technique which includes graphics-processing-unit- (GPU-) accelerated image processing for brightness compensation and noise filtering was developed in this study. Methods: In our ROI fluoroscopic imaging, a copper filter is placed in front of the X-ray tube. The filter contains a round aperture to reduce radiation dose to outside of the aperture. To equalize the brightness difference between inner and outer ROI regions, brightness compensation was performed by use of a simple weighting method that applies selectively to the inner ROI, the outer ROI, and the boundary zone. A bilateral filtering was applied to the images to reduce relatively high noise in the outer ROI images. To speed up the calculation of our technique for real-time application, the GPU-acceleration was applied to the image processing algorithm. We performed a dosimetric measurement using an ion-chamber dosimeter to evaluate the amount of radiation dose reduction. The reduction of calculation time compared to a CPU-only computation was also measured, and the assessment of image quality in terms of image noise and spatial resolution was conducted. Results: More than 80% of dose was reduced by use of the ROI filter. The reduction rate depended on the thickness of the filter and the size of ROI aperture. The image noise outside the ROI was remarkably reduced by the bilateral filtering technique. The computation time for processing each frame image was reduced from 3.43 seconds with single CPU to 9.85 milliseconds with GPU-acceleration. Conclusion: The proposed technique for X-ray fluoroscopy can substantially reduce imaging radiation dose to the patient while maintaining image quality particularly in the ROI region in real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apodized RFI Filtering of Synthetic Aperture Radar Images

Fine resolution Synthetic Aperture Radar (SAR) systems necessarily require wide bandwidths that often overlap spectrum utilized by other wireless services. These other emitters pose a source of Radio Frequency Interference (RFI) to the SAR echo signals that degrades SAR image quality. Filtering, or excising, the offending spectral contaminants will mitigate the interference, but at a cost of often degrading the SAR image in other ways, notably by raising offensive sidelobe levels. This report proposes borrowing an idea from nonlinear sidelobe apodization techniques to suppress interference without the attendant increase in sidelobe levels. The simple post-processing technique is termed Apodized RFI Filtering (ARF).

42 ENGINEERING↗

Updates on the Progress of the Alternate Topology Modulator (AT-HVCM) to support the Proton Power Upgrade (PPU) at the Spallation Neutron Source

The AT-HVCM, achieved by series-stacking the dual-function resonant filter capacitors following each rectification stage, is the baseline design for the PPU project at the SNS [1]. The project requires three AT-HVCM modulators to power 28 additional 700kW klystrons and associated high beta cavities to accelerate 38mA of beam current to 1.3GeV. Each modulator produces an 82 kV, 120A output pulse of 1.35ms duration at a 60Hz repetition rate. The AT design approach improves upon the existing HVCM topology, reducing stresses on the H bridge IGBTs using zero voltage (ZVS) and current switching (ZCS) techniques and on the resonant filter capacitors by limiting voltage reversal. This paper reviews the prototype development progress, currently focused on evaluating system reliability, and discusses some design techniques to achieve the modulator performance requirements.

Solley, Dennis J.↗

Constraints on Metastable Helium in the Atmospheres of WASP-69b and WASP-52b with Ultranarrowband Photometry

Infrared observations of metastable 2{sup 3}S helium absorption with ground- and space-based spectroscopy are rapidly maturing, as this species is a unique probe of exoplanet atmospheres. Specifically, the transit depth in the triplet feature (with vacuum wavelengths near 1083.3 nm) can be used to constrain the temperature and mass-loss rate of an exoplanet’s upper atmosphere. Here, we present a new photometric technique to measure metastable 2{sup 3}S helium absorption using an ultranarrowband filter (FWHM 0.635 nm) coupled to a beam-shaping diffuser installed in the Wide-field Infrared Camera on the 200 inch Hale Telescope at Palomar Observatory. We use telluric OH lines and a helium arc lamp to characterize refractive effects through the filter and to confirm our understanding of the filter transmission profile. We benchmark our new technique by observing a transit of WASP-69b and detect an excess absorption of 0.498% ± 0.045% (11.1σ), consistent with previous measurements after considering our bandpass. We then use this method to study the inflated gas giant WASP-52b and place a 95th percentile upper limit on excess absorption in our helium bandpass of 0.47%. Using an atmospheric escape model, we constrain the mass-loss rate for WASP-69b to be 5.25{sub −0.46}{sup +0.65}×10{sup −4} M{sub J} Gyr{sup −1} (3.32{sub −0.56}{sup +0.67}×10{sup −3} M{sub J} Gyr{sup −1}) at 7000 K (12,000 K). Additionally, we set an upper limit on the mass-loss rate of WASP-52b at these temperatures of 2.1×10{sup −4} M{sub J} Gyr{sup −1} (2.1×10{sup −3} M{sub J} Gyr{sup −1}). These results show that ultranarrowband photometry can reliably quantify absorption in the metastable helium feature.

79 ASTRONOMY AND ASTROPHYSICS↗