Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Radiation transfer in gamma-ray bursts

We have calculated gamma-ray radiative transport in regions of high-energy density, such as gamma-ray burst source regions, using a discrete ordinate, discrete energy group method. The calculations include two-photon pair production and annihilation, as well as three-photon annihilation. The radiation fields itself acts as an absorbing medium, and the optical depth depends on its intensity, so the problem is intrinsically nonlinear. Spherical divergence produces effective collimation of the flux. At high optical depth the high energy (E is greater than 1 MeV) portion of the emergent spectrum assumes a nearly universal form. An approximate limit is derived for the high-energy flux from a gamma-ray burst source region of given size, and the implications of this limit for the distance to the 1979 March 5 event are briefly discussed. We discuss more generally the problem of very luminous bursts, and implications of Galactic halo distances for flare models.

Carrigan, B. J.↗

Genotoxic effects of high-energy iron particles in human lymphoblasts differing in radiation sensitivity

The effects of (56)Fe particles and (137)Cs gamma radiation were compared in TK6 and WTK1 human lymphoblasts, two related cell lines which differ in TP53 status and in the ability to rejoin DNA double-strand breaks. Both cell lines were more sensitive to the cytotoxic and clastogenic effects of (56)Fe particles than to those of gamma rays. However, the mutagenicity of (56)Fe particles and gamma rays at the TK locus was the same per unit dose and was higher for gamma rays than for (56)Fe particles at isotoxic doses. The respective RBEs for TK6 and WTK1 cells were 1.5 and 1.9 for cytotoxicity and 2.5 and 1.9 for clastogenicity, but only 1 for mutagenicity. The results indicate that complex lesions induced by (56)Fe particles are repaired less efficiently than gamma-ray-induced lesions, leading to fewer colony-forming cells, a slightly higher proportion of aberrant cells at the first division, and a lower frequency of viable mutants at isotoxic doses. WTK1 cells (mutant TP53) were more resistant to the cytotoxic effects of both gamma rays and (56)Fe particles, but showed greater cytogenetic and mutagenic damage than TK6 cells (TP53(+)). A deficiency in the number of damaged TK6 cells (a) reaching the first mitosis after exposure and (b) forming viable mutants can explain these results.

Non-NASA Center↗

Observations of diffuse galactic gamma rays

The observations of galactic diffuse gamma radiation are reviewed. The connections of the gamma ray observations with galactic structure and cosmic rays are discussed. The high latitude galactic component and the low latitude emission from the galactic plane are examined. The observations in other regions of the gamma ray spectrum are discussed.

Simpson, G. A.↗

The effects of nuclear power generators upon electronic instrumentation

Radiation sensitivity of electronic instruments susceptible to neutron and gamma radiation is evaluated by means of a radioisotope thermoelectric generator /RTG/. The gamma field of the RTG affects instrument operation and requires shielding, the neutron field does not affect operation via secondary capture-gamma production.

Miller, C. G.↗

Investigation of Radiological Contamination at Parks in the Gateway National Recreation Area - 20350

In 2005, the National Park Service was notified that elevated radiation levels were detected at Great Kills Park during a baseline radiological mapping effort conducted by the Counter Terrorism Bureau of the New York City Police Department and the United States Department of Energy. Great Kills Park is in the Staten Island Unit of the Gateway National Recreation Area. A records search determined that approximately 280 acres of the park was established over an area in which the New York City Department of Sanitation placed approximately 15.1 million cubic yards of waste fill from 1944 to 1948. Since 2005, a series of response actions and investigations were conducted on behalf of the National Park Service to mitigate risk to human health and the environment and to determine the nature of radiological contamination at Great Kills Park. The findings support that radiological contamination is related to certain components of waste fill, including incinerator residue from both on and offsite incinerators, coal ash from the historical use of coal-fired boilers for heating, and incidental radiological artifacts in the waste fill due to their historical use and subsequent disposal. A majority of the radiological artifacts were determined to contain radium-226 and included radioluminescent markers, radium impregnated switch board buttons, radium paint containers, and brachytherapy devices. The National Park Service has several other Parks in the Gateway National Recreation Area that were established in areas with a similar history to Great Kills Park, and overlie waste fill historically placed during landfilling operations, including Spring Creek Park and Dead Horse Bay. Over the last year, the National Park Service has performed additional radiological investigations at Great Kills Park as part of the ongoing Remedial Investigation under the Comprehensive Environmental Response, Compensation, and Liability Act. In addition, preliminary radiological investigations were performed at Spring Creek Park and Dead Horse Bay Park in the Jamaica Bay Unit of Gateway National Recreation Area. These investigation activities identified gamma radiation levels above the ambient level, several of which were attributable to radiological artifacts similar in nature to those recovered at Great Kills Park. Ongoing investigations at Parks in the Gateway National Recreation Area support an association between radiological contamination and historical landfilling practices that were common prior to the regulation and control of radioactive materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A simple code for use in shielding and radiation dosage analyses

A simple code for use in analyses of gamma radiation effects in laminated materials is described. Simple and good geometry is assumed so that all multiple collision and scattering events are excluded from consideration. The code is capable of handling laminates up to six layers. However, for laminates of more than six layers, the same code may be used to incorporate two additional layers at a time, making use of punch-tape outputs from previous computation on all preceding layers. Spectrum of attenuated radiation are obtained as both printed output and punch tape output as desired.

Wan, C. C.↗

Measuring changes in environmental radiological background from construction of an advanced nuclear reactor testing facility

We present a method to survey and track changes in the environmental radiological background during the construction and operation of advanced nuclear reactor facilities. We discuss the results of two surveys of the environmental gamma-radiation background at NEXT Lab, an advanced nuclear reactor research facility on the campus of Abilene Christian University, prior to the introduction of radioactive material. In both surveys, the observed radiation dosage rates are low, with the highest rates at 15% of the average total radiation dosage rate for the United States. We observe ≈20% changes in the radiological background of the property in locations where the environment was changed by construction and ≈20% variations within the facilities correlated with variations in building materials.

Environment↗

Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings

The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.

Wagner, L. J.↗

Radiation Signature Training Device Gamma Equivalent Spheres

Radiation signature training device sources are a continuation of a previous effort to produce a highly enriched uranium equivalent sphere. The original research was designed and motivated to produce a Department of Transportation special form source that emulated the passive gamma signature of a solid metal highly enriched uranium sphere. In addition, the mass reduction (i.e., of the 235 U) minimized logistical costs (security, criticality safety, radiological safety and transportation requirements). Radiation signature training device sources expand on the original concept, redesigning the encapsulation in a modular fashion that allows a variety of loadings. The result is a reconfigurable special nuclear material source set that can vary greatly in the magnitude of the gamma flux and the isotopic distribution. Use of the source to test a variety of standards (N42.34-2015, N42.38-2015, N42.43-2015, N42.53-2018, N42.48-2018, DHS-TCS Backpack Based Radiation Detection Systems, DHS-TCS Handheld Instruments Used for the Detection and Identification of Radionuclides, DHS-TCS Vehicle Mounted Mobile Systems) will be discussed.

Blessinger, Christopher S.↗

Characterization of the degradation of gamma-irradiated elastomers using Raman spectroscopy

This report presents key findings from Raman spectroscopic analysis of gamma-irradiated rubber samples extracted from a laminated lead-damped rubber (LDR) seismic isolation device. The samples were exposed to gamma radiation from a 60Co source in a Foss Therapy Services gamma irradiator, reaching absorbed doses up to 1600 kGy. A distinct threshold near 400 kGy was identified, beyond which significant spectral changes were observed. Two Raman peaks - at approximately 425 cm-1 and 2440 cm-1 - were tracked as a function of dose using Gaussian fitting. The 425 cm-1 peak, attributed to sulfur–sulfur (S–S) bond stretching (resulting from vulcanization of the rubber), exhibited a dose-dependent upshift, indicating radiation-induced crosslinking within the sulfur-based polymer network. Conversely, the 2440 cm-1 peak, likely associated with vibrational modes of additives or impurities, showed a downward shift with increasing dose, suggesting chain scission and degradation of non-rubber constituents. These results provide first-of-a-kind insights into the microstructural evolution of elastomers under high-dose gamma irradiation and establish a preliminary dose threshold for significant degradation. Future work will incorporate multi-modal characterization—including Fourier Transform Infrared (FTIR) spectroscopy, scanning electrom microscopy (SEM) of the rubber surface morphology, thermogravimetric analysis (TGA) to determine changes in thermal stability, and mechanical testing—to correlate molecular-level changes with macroscopic performance of these elastomers as damping media in seismic isolation devices. These findings are expected to provide regulatory guidance and design criteria for qualifying low-damping rubber seismic isolators in advanced nuclear reactor applications.

36 - MATERIALS SCIENCE↗

GeV gamma-ray astronomy telescopes with high angular resolution

Gamma-ray telescopes flown on satellites have poor angular resolution with typical point source error circles of a few square degrees. It is shown that a major improvement in angular resolution for the detection of gamma-rays in the GeV region can be obtained with a single crystal as converter. The electron produced by a gamma ray incident at a small angle to a major crystal axis or plane is captured into channeling and radiates gamma rays. The channeling radiation and the electron-positron pair can be detected and yield point source locations with a precision of 5 arcseconds at 10 GeV. This is an improvement of three orders of magnitude on the angular precision of telescopes sensitive to gamma-rays above 50 MeV flown on Satellites.

Mcbreen, B.↗

Pulsed high-energy gamma rays from PSR 1055-52

The Energetic Gamma Ray Experiment Telescope (EGRET) aboard the Compton Gamma Ray Observatory has detected a high-energy gamma-ray source at a position coincident with that of the radio pulsar PSR 1055-52. Analysis of the EGRET data at the radio pulsar period of 197 ms has revealed pulsed gamma-radiation at energies above 300 MeV, making PSR 1055-52 the fifth detected high-energy gamma-ray pulsar. The pulsed radiation from PSR 1055-52 has a very hard photon spectral index of -1.18 +/- 0.16 and a high efficiency for converting its rotational energy into gamma-rays. No unpulsed emission was observed.

Fierro, J. M.↗

Space radiation effects on composite matrix materials - Analytical approaches

In-vacuo ultraviolet and gamma radiation exposure tests are utilized in a study aimed at the identification of radiation damage mechanisms in composite materials, with the objective of predicting the long-term behavior of composite structures in a space environment at geosynchronous orbit. Physical and chemical methods of polymer characterization are utilized for the study of composite matrix degradation, in conjunction with GC/MS techniques for the analysis of volatile by-products.

Giori, C.↗

Utility of DF-1 for Radioprotection in Lymphocytes

The development of degenerative changes in the vasculature, such as atherosclerosis, is a known consequence of exposure to ionizing radiation, and is thus a concern for astronaut health following long duration space flight. Cellular damage caused by radiation is due to free radical generation and DNA damage. The goal of this project was to assess the ability of a C60-derivative, DF-1, to mitigate cellular damage resulting from radiation exposure in primary human lymphocytes. DF-1 is a water-soluble C60 fullerene encapsulated in dendrimeric functional groups that is proposed to exhibit antioxidant properties. Human lymphocytes are radiosensitive and travel throughout the body potentially causing bystander effects in any tissues they contact. These cells were subjected to varying doses of gamma radiation in the presence or absence of DF-1. Cells were collected at 48 hours post-irradiation for chromosomal aberration studies and at 72 hours post-irradiation for micronuclei studies. These studies showed that the irradiated cells contained more chromosomal aberrations and micronuclei than the control cells. Addition of the DF-1 reduced the amount of observed DNA damage in the irradiated cells. Growth curves were measured for the lymphocytes exposed to 0 and 4 Gray gamma irradiations, and we observed less growth in the cells irradiated at 4 Gy. 2,7-dichlorofluorescein diacetate was used to detect reactive oxygen species production, and increased production of ROS was observed in the irradiated lymphocytes. Human lymphocytes were subjected to varying doses of gamma or photon radiation in the presence and absence of DF-1 and a known radioprotectant, amifostine. After irradiation, the production of reactive oxygen species, growth curves and cell viability were measured. These cells were also collected to quantify chromosomal aberrations and micronuclei formation. We predict that irradiated cells will show the most damage and that DF-1 will provide protective effects similar to those of amifostine, an established radioprotectant.

Reynolds, Julia↗

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗