At least 325 records · Page 18

Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow

OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

NASA Discipline Cardiopulmonary↗

Effect of Actual and Simulated Microgravity on Cardiac Mass and Function in the Rat

The purpose of this study was to test the hypothesis that exposure to actual or simulated microgravity induces cardiac atrophy in male Sprague-Dawley rats. For the microgravity study, rats were subdivided into four groups: Preflight (PF, n = 12); Flight (FL, n = 7); Flight Cage Simulation (SIM, n = 6), and Vivarium Control (VIV, n = 7). Animals in the FL group were exposed to 7 days of microgravity during the Spacelab 3 mission. Animals in the simulated microgravity study were subdivided into three groups: Control (CON, n = 20); 7 day hindlimb unloaded (7HU, n = 10); and 28 day unloaded (28HU, n = 19). In a subset of CON (n = 7) and 28HU (n = 6) rats, a catheter was advanced into the left ventricle to measure the rate of rise in ventricular pressure (+dP/dt) during standing as an estimate of cardiac contractility. After completion of their respective treatments, hearts were removed and weighed. Animals in the PF group were sacrificed 24 hr prior to launch while the FL group was sacrificed 11- 17 hr after landing. The SM and VIV groups were sacrificed 48 and 96 hr after the FL group, respectively. Heart mass was unchanged in adult animals exposed to 7 days of actual microgravity (PF 1.33 +/- .03 g; FL 1.32 +/- 0.02 g; SIM 1.28 +/- 0.04 g; VIV 1.35 +/- 0.04 g). Similarly, heart mass was unaltered with hin~limb unloading (CON 1.40 +/- 0.04 g; 7HU 1.35 +/- 0.06 g; 28HU 1.42 +/- 0.03 g). Hindlimb unloading also had no effect on myocardial contractility (CON 8055 +/- 385 mmHg/sec; 28HU 8545 +/- 755 mmHg/sec). These data suggest that cardiac atrophy does not occur following short-term exposure to microgravity, and that neither short- nor long-term simulated microgravity alter cardiac mass or function.

Ray, Chester H.↗

Condition of cardiovascular systems of astronauts during flight of Soyuz orbital station

Extensive studies of blood circulation functions during manned space flight demonstrated a pronounced tendency toward an increase in minute volume of the blood and a decrease in pulse wave propagation rate. Individual blood circulation indices had large amplitude fluctuations. Physical work loads caused slow recovery of heart rate, arterial pressure and minute blood volume.

Degtyarev, V. A.↗

Artificial Gravity as a Multi-System Countermeasure to Bed Rest Deconditioning: Preliminary Results

Artificial gravity paradigms may offer effective, efficient, multi-system protection from the untoward effects of adaptation to the microgravity of space or the hypogravity of planetary surfaces. Intermittent artificial gravity (AG) produced by a horizontal short-radius centrifuge (SRC) has recently been utilized on human test subjects deconditioned by bed rest. This presentation will review preliminary results of a 41 day study conducted at the University of Texas Medical Branch, Galveston, TX bed rest facility. During the first eleven days of the protocol, subjects were ambulatory, but confined to the facility. They began a carefully controlled diet, and participated in multiple baseline tests of bone, muscle, cardiovascular, sensory-motor, immunological, and psychological function. On the twelfth day, subjects entered the bed rest phase of the study, during which they were confined to strict 6deg head down tilt bed rest for 21 days. Beginning 24 hrs into this period, treatment subjects received one hour daily exposures to artificial gravity which was produced by spinning the subjects on a 3.0 m radius SRC. They were oriented radially in the supine position so that the centrifugal force was aligned with their long body axis, and while spinning, they "stood" on a force plate, supporting the centrifugal loading (2.5 g at the feet, 1.0 g at the heart). The subject station allowed free translation over approximately 10 cm to ensure full loading of the lower extremities and to allow for anti-orthostatic muscle contractions. Control subjects were positioned on the centrifuge but did not spin. Following the bed rest phase, subjects were allowed to ambulate again, but remained within the facility for an additional 9 days and participated in multiple follow-up tests of physiological function.

Warren, L. E.↗

Implementation of the NASA AG-Bed Rest Pilot

To examine the efficacy of artificial gravity (AG) as a countermeasure to spaceflight deconditioning, intermittent AG produced by a horizontal short-radius centrifuge (SRC) was utilized on human test subjects deconditioned by bed rest. This poster will present the subject screening, study design, logistics, and implementation of the 41 day pilot study conducted at the University of Texas Medical Branch, Galveston, TX bed rest facility. An extensive screening process was employed to exclude subjects that were dissimilar to the U.S. astronaut population. Candidates underwent a modified U.S. Air Force Class III physical and tests of bone density, cardiovascular fitness, vestibular system function, psychological fitness and centrifuge tolerance. 15 subjects completed the study; 7 control and 8 AG treatment. All provided written consent to volunteer after the nature of the study and its hazards were clearly explained to them. Standard conditions were strictly regulated; Ta = 72 +/- 2 F, humidity = 70 +/- 5%, light/dark cycle 16h:8h. All fluid intake (minimum 28.5 ml/kg body weight/day) and urine output was monitored. Caloric intake was adjusted as necessary to maintain body weight. Carbohydrate, fat and protein were provided in a ratio of 55:30:15. Phosphorus intake was 1400 mg/d, sodium intake was 2 mmol/kg/d, potassium intake was 1.3 mmol/kg/d, and dietary calcium intake was 1000 mg/d. A physician examined each subject daily. During the first 11 days of the study protocol, subjects were ambulatory, but confined to the facility. Subjects participated in multiple baseline tests of bone, muscle, cardiovascular, sensory-motor, immunological, and psychological function. On the 12th day, subjects entered the bed rest phase of the study, during which they were confined to strict 6? head down tilt bed rest for 21 days. Beginning 24 hrs into this period, treatment subjects received 1 hour daily exposures to artificial gravity which was produced by spinning the subjects on a 3.0 m radius SRC. They were oriented radially in the supine position so that the centrifugal force was aligned with their long body axis, and while spinning, they #stood# on a force plate, supporting the centrifugal loading (2.5 g at the feet, 1.0 g at the heart). The subject station allowed free translation over approximately 10 cm to ensure full loading of the lower extremities and to allow for anti-orthostatic muscle contractions. Control subjects were positioned on the centrifuge but did not spin. Following the bed rest phase, subjects were allowed to ambulate again, but remained within the facility for an additional 9 days and participated in multiple follow-up tests of physiological function.

Warren, L. E.↗

Mechanisms responsible for decreased glomerular filtration in hibernation and hypothermia

Measurements of blood pressure, heart rate, red blood cell and plasma volumes, and relative distribution of cardiac output were made on hibernating and hypothermic adult male and female golden hamsters weighing 120-140 g to study the mechanisms underlying the elimination or marked depression of renal function in hibernation and hypothermia. The results suggest that the elimination or marked depression in renal function reported in hibernation and hypothermia may partly be explained by alterations in cardiovascular system function. Renal perfusion pressure which decreases nearly 60% in both hibernation and hypothermia and a decrease in plasma volume of roughly 35% in the hypothermic animal might both be expected to markedly alter glomerular function.

Tempel, G. E.↗

Cardiac Repolarization Abnormalities and Potential Evidence for Loss of Cardiac Sodium Currents on ECGs of Patients with Chagas' Heart Disease

Some individuals with Chagas disease develop right precordial lead ST segment elevation in response to an ajmaline challenge test, and the prevalence of right bundle branch block (RBBB) is also high in Chagas disease. Because these same electrocardiographic abnormalities occur in the Brugada syndrome, which involves genetically defective cardiac sodium channels, acquired damage to cardiac sodium channels may also occur in Chagas disease. We studied several conventional and advanced resting 12-lead/derived Frank-lead ECG parameters in 34 patients with Chagas -related heart disease (mean age 39 14 years) and in 34 age-/gender-matched healthy controls. All ECG recordings were of 5-10 min duration, obtained in the supine position using high fidelity hardware/software (CardioSoft, Houston, TX). Even after excluding those Chagas patients who had resting BBBs, tachycardia and/or pathologic arrhythmia (n=8), significant differences remained in multiple conventional and advanced ECG parameters between the Chagas and control groups (n=26/group), especially in their respective QT interval variability indices, maximal spatial QRS-T angles and low frequency HRV powers (p=0.0006, p=0.0015 and p=0.0314 respectively). In relation to the issue of potential damage to cardiac sodium channels, the Chagas patients had: 1) greater than or equal to twice the incidence of resting ST segment elevation in leads V1-V3 (n=10/26 vs. n=5/26) and of both leftward (n=5/26 versus n=0/26) and rightward (n=7/26 versus n=3/26) QRS axis deviation than controls; 2) significantly increased filtered (40-250 Hz) QRS interval durations (92.1 8.5 versus 85.3 plus or minus 9.0 ms, p=0.022) versus controls; and 3) significantly decreased QT and especially JT interval durations versus controls (QT interval: 387.5 plus or minus 26.4 versus 408.9 plus or minus 34.6 ms, p=0.013; JT interval: 290.5 plus or minus 26.3 versus 314.8 plus or minus 31.3 ms; p=0.0029). Heart rates and Bazett-corrected QTc/JTc intervals were not significantly different between groups. Patients with Chagas heart disease have increased cardiac repolarization abnormalities, especially by advanced ECG. Moreover, as a group, they have decreased uncorrected JT and QT interval durations and increased filtered QRS interval durations (versus age/gender-matched controls), all suggesting a potential loss of cardiac sodium channel function that might be mediated, in part, by cardiac autonomic damage. Overall findings support Brugada et al's recent hypothesis that the pathway leading to sudden death may often be similar in Chagas' disease and Brugada syndrome i.e., damage to the sodium channel (infectious/immunologic/autonomic in Chagas' genetic in Brugada) with consequent loss of sodium currents may facilitate a phase II-reentry based arrhythmic substrate for ventricular fibrillation in both conditions. In general, JT interval-related results have been underreported in the Chagas literature.

Schlegel, T. T.↗

TPSAS-NF1676L-14834-DND

A recent spin-off from flight deck adaptive automation research at NASA Langley Research Center is a biocybernetic invention referred to informally as MindShift. When using the MindShift technology, a person is able to play off-the-shelf Nintendo Wii games enhanced with biofeedback, which is used to improve self-regulation of physiological functioning. Therefore, the user experiences the challenge of regulating their physiological responses during gameplay in addition to the intended challenges presented in the video game. The research projects being conducted under the supervision of Dr. Alan Pope and Chad Stephens at NASA Langley Research Center examine the effects of interacting with the MindShift invention technology on subjects' self-regulation of heart rate and brainwave activity, performance in the games, performance on cognitive tasks, and subjective experience of effort (i.e., workload). The MindShift invention's effects are being compared to the effects of interacting with the games without the MindShift technology and to the effects of interacting with commercial-off-the-shelf (COTS) brain-computer interface (BCI) technology, specifically the Mattel Mind Flex and the Uncle Milton Star Wars Force Trainer. A 32-channel electroencephalograph system is used to record subjects' brainwave and electrocardiographic activity. The potential for biofeedback game system applications is wide-ranging - from a more engaging form of clinical biofeedback training to a new challenge for avid gamers. Consequently, research needs to be conducted to fully understand the effects that these new games have on a person's physiological and psychological functioning. Biocybernetic technology like MindShift developed from the idea that operators of critical systems such as aerospace systems could hone their stress management and attention skills in biofeedback-augmented leisure activities while off-the-job in order to positively affect their on-the-job performance. This human performance enhancement technology is applicable to skill training on manually controlled critical tasks, such as unmanned aerial vehicle teleoperation, thus enabling the training of cognitive skills to be concurrent with manual skills. Furthermore, this type of technology can apply to medical and clinical uses of biofeedback by serving as an additional form of clinical biofeedback training that may be particularly useful for those with ADHD.

Brittany N Neilson↗

In Vivo Model to Test Implanted Biosensors for Blood pH

Biosensors for monitoring physiologic data continuously through telemetry are available for heart rate, respiration, and temperature but not for blood pH or ions affected by hydrogen ion concentration. A telemetric biosensor for monitoring blood pH on-line could be used to identify and manage problems in fluid and electrolyte metabolism, cardiac and respiratory function during space flight and the acid-base status of patients without the need for venipuncture in patients on Earth. Critical to the development of biosensors is a method for evaluating their performance after implantation. Mature rats, prepared with jugular, cannulas for repeated blood samples, were exposed to a gas mixture containing high levels of carbon dioxide (7%) in a closed environment to induce mild respiratory acidosis. Serial blood gas and pH measurements in venous blood were compared with electrical responses from sensors implanted in the subcutaneous tissue. Animals became slightly tachypneic after exposure to excess CO2, but remained alert and active. After 5 minutes, basal blood pH decreased from 7.404 +/- 0.013 to 7.289 +/- 0.010 (p less than 0.001)and PC02 increased from 45 +/- 6 to 65 +/- 4 mm. Hg (p les than 0.001). Thereafter pH and blood gas parameters remained stable. Implanted sensors showed a decrease in millivolts (mV) which paralleled the change in pH and averaged 5-6 mV per 0.1 unit pH. Implanted sensors remained sensitive to modest changes in tissue pH for one week. A system for inducing acidosis in rats was developed to test the in vivo performance of pH biosensors. The system provides a method which is sensitive, rapid and reproducible in the same and different animals with full recovery, for testing the performance of sensors implanted in subcutaneous tissues.

Arnaud, Sara B.↗

Extended Fayans energy density functional: optimization and analysis

The Fayans energy density functional (EDF) has been very successful in describing global nuclear properties (binding energies, charge radii, and especially differences of radii) within nuclear density functional theory. In a recent study, supervised machine learning methods were used to calibrate the Fayans EDF. Building on this experience, in this work we explore the effect of adding isovector pairing terms, which are responsible for different proton and neutron pairing fields, by comparing a 13D model without the isovector pairing term against the extended 14D model. At the heart of the calibration is a carefully selected heterogeneous dataset of experimental observables representing ground-state properties of spherical even–even nuclei. To quantify the impact of the calibration dataset on model parameters and the importance of the new terms, we carry out advanced sensitivity and correlation analysis on both models. The extension to 14D improves the overall quality of the model by about 30%. The enhanced degrees of freedom of the 14D model reduce correlations between model parameters and enhance sensitivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Marked Exacerbation of Orthostatic Intolerance After Long vs. Short-Duration Spaceflight in Veteran Astronauts

The incidence of postflight orthostatic intolerance following short-duration spaceflight is about 20%. However, the incidence following long-duration spaceflight is unknown. We performed tilt tests on six astronauts before and after their long-duration (129 - 190 days) spaceflights and compared these data to those obtained during stand tests before and after their previous short-duration missions and also to tilt test data from 20 different short-duration (8 - 16 days) flight astronauts. Five of these six became presyncopal during tilt testing after long-duration flights: only one had become presyncopal during stand testing after short-duration flights. Five of the twenty astronauts who flew on other short-duration flights, became presyncopal during upright tilt on landing day. Long-duration presyncopal subjects had lower stroke volumes, lower cardiac outputs and higher peripheral vascular resistance than short-duration presyncopal subjects, but their heart rate responses were not different. One subject had subnormal norepinephrine release with upright posture after a long but not short flight. Plasma volume losses were not greater after long flights. Long-duration spaceflight markedly increases orthostatic intolerance, probably related to altered autonomic function.

Fritsch-Yelle, Janice M.↗

Doppler echo evaluation of pulmonary venous-left atrial pressure gradients: human and numerical model studies

The simplified Bernoulli equation relates fluid convective energy derived from flow velocities to a pressure gradient and is commonly used in clinical echocardiography to determine pressure differences across stenotic orifices. Its application to pulmonary venous flow has not been described in humans. Twelve patients undergoing cardiac surgery had simultaneous high-fidelity pulmonary venous and left atrial pressure measurements and pulmonary venous pulsed Doppler echocardiography performed. Convective gradients for the systolic (S), diastolic (D), and atrial reversal (AR) phases of pulmonary venous flow were determined using the simplified Bernoulli equation and correlated with measured actual pressure differences. A linear relationship was observed between the convective (y) and actual (x) pressure differences for the S (y = 0.23x + 0.0074, r = 0.82) and D (y = 0.22x + 0.092, r = 0.81) waves, but not for the AR wave (y = 0. 030x + 0.13, r = 0.10). Numerical modeling resulted in similar slopes for the S (y = 0.200x - 0.127, r = 0.97), D (y = 0.247x - 0. 354, r = 0.99), and AR (y = 0.087x - 0.083, r = 0.96) waves. Consistent with numerical modeling, the convective term strongly correlates with but significantly underestimates actual gradient because of large inertial forces.

Non-NASA Center↗

Estimation of left ventricular operating stiffness from Doppler early filling deceleration time in humans

Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.

Non-NASA Center↗

Reduced levels of skeletal muscle Na+K+ -ATPase in McArdle disease

We evaluated the hypothesis that impaired sarcolemmal function associated with exaggerated potassium release, impaired potassium uptake, or both may contribute to exertional fatigue and abnormal circulatory responses to exercise in McArdle disease (MD). The cellular mechanism of exertional fatigue and muscle injury in MD is unknown but likely involves impaired function of the ATPases that couple ATP hydrolysis to cellular work, including the muscle sodium potassium pump (Na+K+-ATPase). However, the concentration of muscle Na+K+ pumps in MD is not known, and no studies have related exercise increases in blood potassium concentrations to muscle Na+K+ pump levels. We measured muscle Na+K+ pumps (3H-ouabain binding) and plasma K+ in response to 20 minutes of cycle exercise in six patients with MD and in six sex-, age-, and weight-matched sedentary individuals. MD patients had lower levels of 3H-ouabain binding (231 +/- 18 pmol/g w.w., mean +/- SD, range, 210 to 251) than control subjects (317 +/- 37, range, 266 to 371, p < 0.0004), higher peak increases in plasma potassium in response to 45 +/- 7 W cycle exercise (MD, 1.00 +/- 0.15 mmol/L; control subjects, 0.48 +/- 0.09; p < 0.0001), and mean exercise heart rate responses to exercise that were 45 +/- 12 bpm greater than control subjects. Our results indicate that Na+K+ pump levels are low in MD patients compared with healthy subjects and identify a limitation of potassium reuptake that could result in sarcolemmal failure during peak rates of membrane activation and may promote exaggerated potassium-activated circulatory responses to submaximal exercise. The mechanism of the low Na+K+ pump concentrations in MD is unknown but may relate to deconditioning or to disruption of a close functional relationship between membrane ion transport and glycolysis.

Non-NASA Center↗

A new technique to determine the correlation between the QT interval and heart-rate for control and SIDS babies

The ability of the autonomic nervous system to alter the QT interval in response to heart rate changes is essential to cardiovascular control. An accurate way to determine the relation between QT intervals and their corresponding RR intervals is described. A computer algorithm measures the RR intervals using digital filtering and cross-correlating the QRS sections of consecutive waveforms. The QT intervals is calculated by choosing a section of, the ECG that includes the T wave and cross-correlating it with all the consecutive T waves. At least 4000 pairs of QT-RR intervals are computed for each subject and a best fit correlation function determines the relations between the QT and RR intervals. This technique enables to establish a precise correlation between RR and QT in order to distinguish between control and SIDS babies.

Non-NASA Center↗

Myocardial correlates of helium-cold induction and maintenance of hypothermia.

Hypothermia was induced in the golden hamster Mesocricetus auratus, using the helium-cold method. The first group of hamsters was sacrificed immediately after induction to rectal temperature 7 C, a second group was sacrificed after being maintained at a body temperature of 7 C for 18-24 hr, and a third group consisted of unexposed controls. The hearts were excised and the ventricles analyzed for hypoxic damage, glycogen, and catecholamines. In the short-term hypothermic animals, resting tension was increased while peak isometric tension, generated tension after 10 min of anoxic exposure, glycogen, and catecholamines were all reduced. All of the functional parameters recovered in the long-term hypothermic group, while glycogen and catecholamines showed a trend toward recovery. It is concluded that myocardial hypoxia develops during induction into hypothermia when using the helium-cold method. This effect is reversible and hypoxic damage does not increase as the hypothermic exposure is prolonged.

Anderson, G. L.↗

Cardiovascular, renal, electrolyte, and hormonal changes in man during gravitational stress, weightlessness, and simulated weightlessness: Lower body positive pressure applied by the antigravity suit

Because of their erect posture, humans are more vulnerable to gravitational changes than any other animal. During standing or walking man must constantly use his antigravity muscles and his two columns, his legs, to balance against the force of gravity. At the same time, blood is surging downward to the dependent portions of the body, draining blood away from the brain and heart, and requiring a series of complex cardiovascular adjustments to maintain the human in a bipedal position. It was not until 12 April 1961, when Yuri Gagarin became the first human being to orbit Earth, that we could confirm man's ability to maintain vital functions in space -- at least for 90 min. Nevertheless, man's adaptation to weightlessness entails the deconditioning of various organs in the body. Muscles atrophy, and calcium loss leads to loss of bone strength as the demands on the musculoskeletal system are almost nonexistent in weightlessness. Because of the lack of hydrostatic pressures in space, blood rushes to the upper portions of the body, initiating a complex series of cardioregulatory responses. Deconditioning during spaceflight, however, first becomes a potentially serious problem in humans returning to Earth, when the cardiovascular system, muscles and bones are suddenly exposed to the demanding counterforce of gravity -- weight. One of the main purposes of our studies was to test the feasibility of using Lower Body Positive Pressure, applied with an antigravity suit, as a new and alternative technique to bed rest and water immersion for studying cardioregulatory, renal, electrolyte, and hormonal changes in humans. The results suggest that Lower Body Positive Pressure can be used as an analog of microgravity-induced physiological responses in humans.

Kravik, Stein E.↗

Effects of prolonged head-down bed rest on physiological responses to moderate hypoxia

To determine the effects of hypoxia on physiological responses to simulated zero-gravity cardiopulmonary and fluid balance measurements were made in 6 subjects before and during 5-degree head-down bed rest (HDBR) over 8 d at 10,678 ft and a second time at this altitude as controls (CON). The V-dot(O2)(max) increased by 9 percent after CON, but fell 3 percent after HDBR. This reduction in work capacity during HDBR could be accounted for by inactivity. The heart rate response to a head-up tilt was greatly enhanced following HDBR, while mean blood pressure was lower. No significant negative impact of HDBR was noted on the ability to acclimatize to hypoxia in terms of pulmonary mechanics, gas exchange, circulatory or mental function measurements. No evidence of pulmonary interstitial edema or congestion was noted during HDBR at the lower PIO2 and blood rheology properties were not negatively altered. Symptoms of altitude illness were more prevalent, but not marked, during HDBR and arterial blood gases and oxygenation were not seriously effected by simulated microgravity. Declines in base excess with altitude were similar in both conditions. The study demonstrated a minimal effect of HDBR on the ability to adjust to this level of hypoxia.

Loeppky, J. A.↗