Search NASA⌕ Search

SEARCH · Search NASA

Results for “HVAC efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Dual Fuel Heat Pump

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Dual Fuel Heat Pump" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Levelized Cost of Exergy Framework

Exergy is the amount of energy within a substance or within a transfer of energy that can be used to produce work or some other useful output when interacting with some reference environment. Two different energy systems that produce the same output with the same exergetic efficiency must necessarily have the same amount of exergy input, even if the amount of energy input to the two systems is vastly different. For example, a low-grade heat-driven desalination would require far more energy input than a reverse osmosis (RO) plant producing the same amount of water, but if their exergetic efficiencies were the same, they would require the same amount of exergy input. Thus, comparisons between different energy sources on the basis of energy is not always appropriate. Instead, a comparison on a per unit exergy basis provides more insight on the cost-effectiveness of different energy sources and systems. In this presentation, we describe a framework for analyzing the levelized cost of exergy (LCOEx) for both inputs and outputs of various energy systems. Our framework illustrates how the cost per unit exergy of a system's energy source, as well as the exergetic efficiency of the system, greatly affect the cost of the system output. We use the levelized cost of electricity as a benchmark value for LCOEx, due to electricity's ubiquity as an energy source, and because it is relatively inexpensive on a per unit exergy basis. The LCOEx of various heat sources are then compared to the LCOEx of electricity. Medium- and high-grade industrial heat (> 150 degrees C) produced by natural gas tends to have an LCOEx on par with electricity. This is due to the low cost of natural gas, as well as the high exergy content of heat at higher temperatures. Meanwhile, low-grade heat tends to be an expensive exergy source, owing to the low exergy content of the low-grade heat. We first apply our framework to desalination, where RO has come to dominate, due to the low LCOEx of the energy source (electricity) and relatively high exergetic efficiency of RO compared to thermal desalination systems. We then use this framework to highlight an opportunity for dehumidification systems to experience a similar cost improvement as desalination has. If an electrically-driven, high exergetic efficiency dehumidification system were developed (such as the membrane-based dehumidification systems proposed in literature), it would use a low cost exergy source with a high exergetic efficiency and could potentially lower the cost of dehumidification in the way that RO has done for desalination. Finally, we apply our framework to various fuels (natural gas, hydrogen, gasoline, etc.) and energy systems across different sectors (desalination, dehumidification, vehicles, etc.) to understand the variation in the cost of exergy input and exergetic efficiency of different systems and technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparative study on the overall energy performance between photovoltaic and Low-E insulated glass units

In this report a novel semi-transparent building integrated photovoltaic (BIPV) laminate was developed and introduced in this paper. It was produced by cutting standard mono-crystalline silicon solar cells into small strips and then making electrical connections between each strip before laminating the cells between two layers of glass. The overall energy performance and energy saving potential of the BIPV insulated glass unit (IGU) under real world conditions were identified through a side by side comparative study. Compared to the reference IGU, the BIPV IGU had lower solar heat gain coefficient (SHGC) but much higher U-factor. The average HVAC electricity saving of the BIPV IGU was about 10% relative to the reference IGU. Daylighting measurement and analysis were carried out to evaluate the trade-offs associated with the BIPV IGU between daylight, glare, and lighting energy use. The results indicated that the BIPV IGU is better than the reference IGU in reducing discomfort glare. However, if the most conservative viewpoint near the window is used for the assessment, a lower transmittance BIPV IGU is required to bring the overall discomfort levels below the perceptible level. Lastly, the net energy saving potential associated with the novel BIPV IGU was identified based on the power, thermal and daylighting performance. On average, the BIPV IGU saved 16.8% of the total electricity use of the room. Further studies and improvement on the energy conversion efficiency of solar cells, the optimal transmittance as well as the thermal properties would make this technology more energy-efficient and affordable.

14 SOLAR ENERGY↗

Toluene adsorption and capacity regeneration using zeolite-based monolith and activated carbon fiber felt

Common adsorbents studied to remove volatile organic compounds (VOCs) from indoor air can release previously adsorbed VOCs back into the indoor space when the adsorbent is saturated or if the VOC concentration fluctuates. A durable adsorbent with a continuous regeneration strategy could prevent this recontamination of the indoor air and reduce adsorbent disposal waste. A deeper understanding of the adsorption and desorption behavior of VOC adsorbents is needed to create an efficient regeneration strategy. This study investigated the adsorption and thermal desorption behavior of toluene on two different adsorbents, (1) a zeolite-based adsorbent and (2) an activated carbon fiber (ACF) felt. Consistent adsorption behavior across a series of toluene concentrations was used to experimentally determine effective adsorption capacity. When the cumulative adsorption between thermal regeneration steps was maintained below the maximum effective capacity with 0% breakthrough, the zeolite-based adsorbent was found to effectively minimize passive desorption. The impact of regeneration feed conditions, such as inert, oxidizing, humidified air, on thermal desorption was examined. These conditions influenced desorption of the zeolite-based adsorbent but had minimal impact on the ACF felt adsorbent, which would lead to different regeneration schedules and methods for applications in buildings' heating, ventilation, and air conditioning (HVAC) systems.

Moses-DeBusk, Melanie [Oak Ridge National Laborato↗

State-of-the-art on research and applications of machine learning in the building life cycle

Fueled by big data, powerful and affordable computing resources, and advanced algorithms, machine learning has been explored and applied to buildings research for the past decades and has demonstrated its potential to enhance building performance. This study systematically surveyed how machine learning has been applied at different stages of building life cycle. By conducting a literature search on the Web of Knowledge platform, we found 9579 papers in this field and selected 153 papers for an in-depth review. The number of published papers is increasing year by year, with a focus on building design, operation, and control. However, no study was found using machine learning in building commissioning. There are successful pilot studies on fault detection and diagnosis of HVAC equipment and systems, load prediction, energy baseline estimate, load shape clustering, occupancy prediction, and learning occupant behaviors and energy use patterns. None of the existing studies were adopted broadly by the building industry, due to common challenges including (1) lack of large scale labeled data to train and validate the model, (2) lack of model transferability, which limits a model trained with one data-rich building to be used in another building with limited data, (3) lack of strong justification of costs and benefits of deploying machine learning, and (4) the performance might not be reliable and robust for the stated goals, as the method might work for some buildings but could not be generalized to others. Finally, findings from the study can inform future machine learning research to improve occupant comfort, energy efficiency, demand flexibility, and resilience of buildings, as well as to inspire young researchers in the field to explore multidisciplinary approaches that integrate building science, computing science, data science, and social science.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

Decarbonizing Building Thermal Systems: A How-to Guide for Heat Pump Systems and Beyond

Buildings account for a substantial portion of carbon emissions, primarily due to the widespread use of fossil fuels in heating systems. Decarbonization of heating is essential to meet climate targets and reduce the environmental impact of buildings. Heat pumps are capable of leveraging renewable energy sources and can provide heating and cooling in an energy-efficient manner. By leveraging heat pump technology, buildings can significantly reduce their carbon footprint, minimize energy consumption, and decrease their reliance on fossil fuels. The design and construction community plays a pivotal role in facilitating the transition to heat pump systems for heating and cooling. However, this transition requires specialized knowledge and expertise. This resource was developed for architects, engineers, and contractors in response to an industry need for a comprehensive technical resource that guides them through the intricacies of heat pump system design, installation, and maintenance. This resource provides detailed information on system sizing, selection of appropriate heat systems, heat sources, and integration with existing building systems. Moreover, it emphasizes best practices for ensuring operational efficiency, system longevity, and reliability. The development of this recourse was a collaborative effort between NREL/DOE Better Buildings Design and Construction Allies and ASHRAE Task Force for Building Decarbonization. This resource is composed of two complimentary portions that will be completed and released on separate time frames. The first portion will be completed and released in 2023, while the second portion will be released in 2024.

building thermal systems↗

Market Barriers and Drivers for the Next Generation Fault Detection and Diagnostic Tools

Commercial buildings in the U.S. consume as much as 30% excess energy compared to buildings that operate fault free and efficiently. Fault detection and diagnostic (FDD) platforms help to continually identify operational inefficiencies and maintain low-carbon performance. However, the recommendations generated by FDD tools need to be implemented by technicians, resulting in delays or lost savings opportunities. Recent research advances showed fault AUTOcorrection integrating with commercial FDD offerings filled this gap. Seven innovative AUTOcorrection algorithms were integrated into two FDD platforms and deployed across four buildings. The enhanced tools successfully correct faults focusing on incorrectly programmed schedules, override not released, control hunting, rogue zone, and suboptimal setpoints. Although its technical efficacy has been proven in the field, fault AUTO-correction is still early in the deployment cycle and opportunities and barriers need to be understood to reach its full potential in market transformation. This paper broadly introduces the new technology that automatically corrects HVAC faults. The authors describe in detail technology potential, market barriers, and enablers for scalability based on field testing results and interviews with the FDD providers and facility managers. The interviewees agreed that AUTO-correction can reduce the extent to which savings are dependent upon human intervention, scale building operators’ ability to act on FDD findings (especially for facilities with small operation teams), and achieve significant savings. To enable scalable deployment, future efforts are needed to overcome the barriers such as cybersecurity and accountability concerns from building operators and standardization of control parameters used in building automation systems.

Pritoni, Marco↗

Optimal Management of Grid-Interactive Efficient Buildings via Safe Reinforcement Learning

Reinforcement learning (RL)-based methods have achieved significant success in managing grid-interactive efficient buildings (GEBs). However, RL does not carry intrinsic guarantees of constraint satisfaction, which may lead to severe safety consequences. Besides, in GEB control applications, most existing safe RL approaches rely only on the regularisation parameters in neural networks or penalty of rewards, which often encounter challenges with parameter tuning and lead to catastrophic constraint violations. To provide enforced safety guarantees in controlling GEBs, this paper designs a physics-inspired safe RL method whose decision-making is enhanced through safe interaction with the environment. Different energy resources in GEBs are optimally managed to minimize energy costs and maximize customer comfort. The proposed approach can achieve strict constraint guarantees based on prior knowledge of a set of developed hard steady-state rules. Simulations on the optimal management of GEBs, including heating, ventilation, and air conditioning (HVAC), solar photovoltaics, and energy storage systems, demonstrate the effectiveness of the proposed approach.

Huo, Xiang↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial building loads providing ancillary services In PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Understanding Electric Vehicle Range and Charging Needs: Interactions Between Ambient Temperature, Commute Patterns, and State-of-Charge Usage

Electric vehicle (EV) performance can vary substantially under real-world operating conditions, particularly due to ambient temperature effects on energy consumption, battery behavior, and thermal management requirements. This study quantifies how weather conditions, daily driving patterns, and State-of-Charge (SOC) usage strategies jointly influence EV driving range, charging frequency, and overall energy efficiency. A detailed and experimentally validated Autonomie vehicle model is developed, integrating a powertrain, a mono-zonal cabin model, and a battery electro-thermal model. Three battery sizes (200-, 300-, and 400-mile homologated ranges) are assessed across five commute profiles (20–200 miles) and six ambient temperatures (−18 °C to 50 °C), including scenarios with and without preconditioning. Results show that extreme temperatures could significantly decrease the maximum achievable range by up to 55% in cold conditions (−18 °C) and 40% in hot conditions (50 °C), relative to moderate conditions. Larger battery packs retain a greater fraction of their nominal range under thermal stress, while smaller packs experience sharper relative penalties due to the higher contribution of thermal loads to total energy demand. The analysis further demonstrates that limiting operation to partial SOC windows (e.g., 80–20%), a common real-world practice, significantly reduces achievable range and increases charging frequency, particularly in cold weather. Thermal preconditioning while plugged in is shown to mitigate these effects for short trips, reducing energy consumption by up to 31% in hot conditions and 7% in cold conditions. The findings demonstrate how climate, SOC usage behavior, and thermal management jointly shape the practical driving capability of EVs, highlighting the importance of efficient thermal management and realistic user charging strategies for ensuring reliable EV operation across diverse climatic scenarios.

33 ADVANCED PROPULSION SYSTEMS↗