Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura↗

Blade and Rim Seal Design of a First Stage High Pressure Turbine for a 300 MWe Supercritical CO2 Power Cycle

A first stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design 3D with objectives of increasing efficiency and decreasing heat load to the blade. The National Institute of Standards and Technology Reference Fluid Thermodynamic and Transport Properties Database (NIST REFPROP) [1] data for supercritical CO2 is formatted into tables of bicubic polynomial coefficients for use in condensable gas simulations in FINE/Turbo. Nearly 3000 unique shapes are evaluated via three-dimensional Reynolds Averaged Navier Stokes simulations, yielding increases in efficiency of up to 0.85 percentage points and decreases in heat load of 14%. A final blade, deemed the advanced blade, is chosen for future experimental analysis. Following this, a squealer tip optimization is performed on both the baseline and advanced blade designs. This optimization resulted in a performance gain of 1.25 points in efficiency and 15% reduction in tip heat load compared to the baseline flat tip design at the same clearance. In tandem, an optimization of the rotor-stator platform rim seal is performed using a parametrized geometry allowing for straight, meandering, and knife seal cavities. This multi-objective optimization focuses on decreasing the cooling mass flow and increasing the heat flux from the rotor and stator disk. The optimization resulted in cooling mass flow decreases of up to 26% while maintaining the average heat flux on the rim seal.

Tuite, Logan↗

Aerothermal Analysis of the Rocket Lab Venus Probe Heatshield

This document provides an overview of the aerothermodynamic analyses performed by the Aerothermodynamics Branch at NASA Langley Research Center for the Rocket Lab Venus Probe (RLVP). In addition to defining the baseline heating environment to the heatshield, this document pursues the experimental validation of key physical models at RLVP-relevant conditions. This experimental validation analysis, which captures the model form uncertainty, is used as one of two primary components of the margin assessment, where the other component is the parametric uncertainty. These model form (experimental) and parametric uncertainty components are used to construct a spatial and time varying margin for the heating to the RLVP heatshield. The margin is evaluated as the sum of the parametric and model form uncertainty components. The model form uncertainty is defined as the difference between the RLVP-relevant measurements and their simulations, using the upper limit uncertainty bounds for both the measurements and simulations in the comparisons. The differences in the dominant physics in the stagnation region and flank lead to the separate RLVP-relevant measurements for assessing the model form uncertainty in these two regions. These regions are addressed as follows: Stagnation Region Heating Environment: For the high-temperature stagnation-region, both the radiative heating and impact of blowing on convective heating are significant, while the impacts of turbulence and roughness are negligible. Coupled radiation and ablation LAURA/HARA solutions with ray-tracing provide the radiative heating over the entire vehicle, including the contributions from the Venus atmosphere and ablation species. Non-ablating LAURA simulations provide the convective heating. During the material-response computation typically used for TPS sizing, this non-ablating convective heating is corrected for the impact of ablation using the blowing correction. Coupled ablation LAURA simulations that capture finite-rate sur-face processes show that this blowing correction may be non-conservative over most of the heatshield. This non-conservatism is due to hydrogen recombination in the finite-rate surface model, which tends to increase the coupled ablation convective heating to near the non-ablating values, therefore making any reduction in the non-ablating value through the blowing correction non-conservative. This non-conservatism due to H catalysis is captured in the parametric component of the margin. The best available ground-test measurements that capture the impact of blowing on stagnation region convective heating, at RLVP-relevant conditions, indicate that the current blowing reduction model is non-conservative by up to 20% at RLVP-relevant blowing rates (the coupled blowing simulations were also non-conservative). Because of the relatively low velocity of the ground tests and the non-Venus atmospheric chemistry, these measurements do not capture the chemistry and therefore do not inform the uncertainty due to H catalysis. However, they do capture the fluid mechanics of blowing. The non-conservatism of the blowing correction implied by these measurements is covered by the model form component of the margin, which leads to total margin values over 50%. For the radiative heating, the shock-tube informed bias approach suggests a model form uncertainty of roughly 20%, while the parametric uncertainty analysis suggests values over 100%. The combined stagnation-point radiation margin of over 100% leads to peak margined radiative heating values of over300 W/cm2, which remains small relative to the peak margined convective heating of nearly 2000 W/cm2. Based on this analysis, at the stagnation point, the peak margined heat rate is 2203 W/cm2 and the margined total heat load is 31.5 kJ/cm2 for the current nominal trajectory. Flank Heating Environment: The forebody flank (and near-shoulder) heating environment is dominated by the impact of turbulence, roughness augmentation, and ablation on the convective heating. An extensive collection of ground test measurements with RLVP-relevant turbulence and roughness is studied to show that the maximum difference between the simulated and measured convective heating is 5%. However, with the exception of the Holden measurements from the 1980s, these measurements do not include roughness elements extending into the supersonic region of the boundary layer, which is likely to occur for RLVP (due to the 45 degree sphere-cone geometry). The interaction between the supersonic flow and roughness could cause convective heating augmentation fundamentally different than for locally subsonic flow. Although these Holden measurements are consistent with the other measurements considered, another path was pursued to assure that the rough-ness height extending into supersonic flow does not fundamentally change the roughness augmentation. This additional path was a computational effort to resolve the roughness elements in the CFD grid, so that the interaction be-tween the roughness elements and locally supersonic flow may be simulated in detail. This roughness-resolved CFD simulation is feasible because of the RLVP forebody TPS’s patterned roughness, which may be approximated analytically, and because of the axisymmetric nominal flow field, which allows a narrow surface region to be simulated and therefore make the computational expense feasible. These grid-resolved roughness simulations, which are performed at actual RLVP flight conditions, result in heating augmentation values that are below the design approach for roughness augmentation. This provides evidence that the design approach for RLVP roughness augmentation is sufficient. Based on this analysis, at this flank or near-shoulder location, the peak margined total heat rate is 2088 W/cm2and the margined total heat load is 26.0 kJ/cm2for the current nominal trajectory. Heat flux, shear, pressure and heat transfer coefficient at the RLVP stagnation point and near shoulder location are evaluated for the entire trajectory, and curved fit to a functional form of F=AρB∞UC∞. These simplified relationships for the nominal and margined aerothermal environments are referred to as aerothermal indicators, and presented at the end of this document.

Christopher O Johnston↗

Method Improvements in Thermal Analysis of Mach 10 Leading Edges

Several improvements have recently been made in the thermal analysis methods for leading edges of a hypersonic vehicle. The leading edges of this vehicle undergo exceptionally high heat loads that incorporate extreme spatial gradients as well as severe transients. Due to the varying flight conditions, complex geometry, and need for thermal loads at many points along the trajectory, full computational fluid dynamics (CFD) analysis of the aeroheating; loads is not feasible. Thus, engineering methods must be used to determine the aeroheating on the vehicle surfaces, and that must be utilized in the thermal analysis. Over the last year, the thermal analysis of a hypersonic vehicle has been enhanced in several ways. Two different engineering codes are used to predict aeroheating loads: one over the curve near the stagnation point, and the other on flat surfaces downstream of the leading edge. These two are matched together at the intersection point using a method that allows closer approximation of CFD results. User-developed FORTRAN, which is part of the thermal solver PATRAN Thermal, is used to accomplish this. The customizable FORTRAN code also allows use of many different time- and space-dependent factors, interpolation of the heat load in time and space, and inclusion of both highly swept and unswept grid structures. This FORTRAN is available to other PATRAN users who may want to accomplish a similar objective in analysis. Flux, rather than convective coefficient, is used to define heat loads, which allows more accurate analysis as well as better application of margins. Improvements have also been made in more efficient utilization of imported CAD geometry, by creating faces on solids to facilitate load application.

Amundsen, Ruth M.↗

Thermal links for the implementation of an optical refrigerator

Optical refrigeration has been demonstrated by several groups of researchers, but the cooling elements have not been thermally linked to realistic heat loads in ways that achieve the desired temperatures. The ideal thermal link will have minimal surface area, provide complete optical isolation for the load, and possess high thermal conductivity. We have designed thermal links that minimize the absorption of fluoresced photons by the heat load using multiple mirrors and geometric shapes including a hemisphere, a kinked waveguide, and a tapered waveguide. While total link performance is dependent on additional factors, we have observed net transmission of photons with the tapered link as low as 0.04%. Our optical tests have been performed with a surrogate source that operates at 625 nm and mimics the angular distribution of light emitted from the cooling element of the Los Alamos solid state optical refrigerator. We have confirmed the optical performance of our various link geometries with computer simulations using CODE V optical modeling software. In addition we have used the thermal modeling tool in COMSOL MULTIPHYSICS to investigate other heating factors that affect the thermal performance of the optical refrigerator. Assuming an ideal cooling element and a nonabsorptive dielectric trapping mirror, the three dominant heating factors are (1) absorption of fluoresced photons transmitted through the thermal link, (2) blackbody radiation from the surrounding environment, and (3) conductive heat transfer through mechanical supports. Modeling results show that a 1 cm{sup 3} load can be chilled to 107 K with a 100 W pump laser. We have used the simulated steady-state cooling temperatures of the heat load to compare link designs and system configurations.

47 OTHER INSTRUMENTATION↗

Injection of multiple shattered pellets for disruption mitigation in DIII-D

Plasma shutdown experiments in DIII-D have injected multiple shattered pellets at different toroidal locations for the first time, as is planned for the ITER disruption mitigation system. Systematically varying the relative timing of the two pellets suggests that simultaneously injected pellets may influence the assimilation of each other, altering the resulting disruption characteristics compared to a single pellet injecting similar neon quantities. Thermal quench (TQ) radiation measured near the injection location is reduced with the dual pellets, contrary to TQ radiation measured away from the injection ports, which does not show a clear difference between single or dual pellet injections. The mitigation of other disruption loads, such as the current quench (CQ) duration and divertor heat loads, decrease when the pellets enter the plasma simultaneously compared to single shattered pellet injections with similar neon quantities. This similar reduction in mitigation of CQ and conductive loads is consistent with the observed reduction in total TQ radiation. The time between initial pellet injection and the end of the TQ is shorter when both pellets are injected simultaneously compared to a single pellet. This lower cooling duration may limit the amount of the neon assimilated by the plasma prior to the end of the TQ, consistent with the observed reduction in radiation. The injected impurities spread primarily in the parallel direction, away from the source at the injection location. The addition of two shattered pellet injectors shows that the initial poloidal radiation is spread out into two distinct regions, cooling multiple flux tubes simultaneously, which may induce global MHD instabilities more rapidly than a single flux tube of impurities leading to a shorter cooling duration. The electron density increased by approximately a factor of two with the addition of multiple pellets, but is highly sensitive to the time between injections. Here, a maximum density increase is found when both pellets arrive at the plasma prior to the start of the TQ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and analysis of the Space Station Freedom Active Thermal Control System radiators using SINDA/FLUINT

Detailed SINDA/FLUINT models have been developed to assess the adequacy of the Space Station Freedom External Thermal Control System's radiator design, as well as to simulate the effects of various operational scenarios. Design margins can be deduced by quantifying such real-world effects as flow maldistribution due to line-pressure drop and uneven heat loads. The factor which most reduced the heat-rejection capacity is an uneven heat load split between the two low temperature loops.

Andish, Kambiz K.↗

Low temperature barriers with heat interceptor wells for in situ processes

A system for reducing heat load applied to a frozen barrier by a heated formation is described. The system includes heat interceptor wells positioned between the heated formation and the frozen barrier. Fluid is positioned in the heat interceptor wells. Heat transfers from the formation to the fluid to reduce the heat load applied to the frozen barrier.

42 ENGINEERING↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Design and test of a pumped two-phase mounting plate

The design, fabrication, and testing of the full-scale development unit of a pumped two-phase mounting plate (TPMP) used in advanced two-phase spacecraft thermal control systems are described. The mounting plate is tested with R-11 in the evaporator mode for total heat loads of over 3000 watts and local heat fluxes over 4 W/sq cm, and in the condenser mode with condenser loads from 60 to 400 watts and inlet qualities from 8 to 94 percent. The calculated heat-transfer coefficients are between 0.66 and 1.0 W/sq cm/C and are nearly independent of the flow rate and heat load except at very low heat loads. It is shown that the TPMP can be run with inlet conditions down to 22 C subcooling without any significant gradients in the plate and that it performs well with nonuniform heat fluxes.

Grote, M. G.↗

Effects of filament geometry on the arc efficiency of a high-intensity He{sup +} ion source

A strongly focusing high-intensity He{sup +} ion source equipped with three concave electrodes has been designed and constructed as the beam source for a high-energy He{sup 0} neutral beam probe system to diagnose fusion-produced alpha particles in thermonuclear fusion plasmas. The reduction of heat load onto the concave extraction electrodes is particularly important for a long pulse operation, as the heat load deforms the electrodes and thus the beam focal length. The effects on the arc efficiency (beam current/arc power) of the ion source due to the discharge filament structure (straight-type and L-shape-type filaments), size (filament diameters of 2 and 1.5 mm), number, and the locations have been studied. Choice of the appropriate filament structure improved the arc efficiency by 17%.

43 PARTICLE ACCELERATORS↗

RF-sheath heat flux estimates on Tore Supra and JET ICRF antennae. Extrapolation to ITER

RF-sheath induced heat loads are identified from infrared thermography measurements on Tore Supra ITER-like prototype and JET A2 antennae, and are quantified by fitting thermal calculations. Using a simple scaling law assessed experimentally, the estimated heat fluxes are then extrapolated to the ITER ICRF launcher delivering 20 MW RF power for several plasma scenarios. Parallel heat fluxes up to 6.7 MW/m{sup 2} are expected very locally on ITER antenna front face. The role of edge density on operation is stressed as a trade-off between easy RF coupling and reasonable heat loads. Sources of uncertainty on the results are identified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heaters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

cryocooling↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Crycooling↗

Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and to verify its ability to cool large areas or components in the 3 degrees Kelvin temperature range. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by simply applying power to both the capillary pump and the evaporator plate without pre-conditioning. It could adapt to a rapid heat load change and quickly reach a new steady state. Heat removal between 10 megawatts and 140 megawatts was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Thermal Control Systems↗

Improvements of the magnetic field design for SPIDER and MITICA negative ion beam sources

The design of the magnetic field configuration in the SPIDER and MITICA negative ion beam sources has evolved considerably during the past four years. This evolution was driven by three factors: 1) the experimental results of the large RF-driven ion sources at IPP, which have provided valuable indications on the optimal magnetic configurations for reliable RF plasma source operation and for large negative ion current extraction, 2) the comprehensive beam optics and heat load simulations, which showed that the magnetic field configuration in the accelerator is crucial for keeping the heat load due to electrons on the accelerator grids within tolerable limits, without compromising the optics of the negative ion beam in the foreseen operating scenarios, 3) the progress of the detailed mechanical design of the accelerator, which stimulated the evaluation of different solutions for the correction of beamlet deflections of various origin and for beamlet aiming. On this basis, new requirements and solution concepts for the magnetic field configuration in the SPIDER and MITICA beam sources have been progressively introduced and updated until the design converged. The paper presents how these concepts have been integrated into a final design solution based on a horizontal “long-range” field (few mT) in combination with a “local” vertical field of some tens of mT on the acceleration grids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heuristic predictions of RMP configurations for ELM suppression in ITER burning plasmas and their impact on divertor performance

Abstract A subspace of resonant magnetic perturbation (RMP) configurations for edge localized mode (ELM) suppression is predicted for H-mode burning plasmas at 15 MA current and 5.3 T magnetic field in ITER. Perturbations to the core plasma can be reduced by a factor of 2 for equivalent edge stability proxies, while the perturbed plasma boundary geometry remains mostly resilient. The striated domain of perturbed field lines connecting from the main plasma (normalized poloidal flux < 1 ) to the divertor targets is found to be significantly larger than the expected heat load width in the absence of RMPs. This facilitates heat load spreading with peak values at an acceptable level below 10 MW m − 2 on the outer target already at moderate gas fueling and low Ne seeding for additional radiative dissipation of the 100 MW of power into the scrape-off layer (SOL). On the inner target, however, re-attachment is predicted away from the equilibrium strike point due to increased upstream heat flux, higher downstream temperature and less efficient impurity radiation.

3D plasma boundary modeling↗

Material Assessment for ITER's Collective Thomson Scattering first mirror

The International Thermonuclear Energy Reactor (ITER) Collective Thomson Scattering (CTS) system is a diagnostic instrument that measures plasma density and velocity through Thomson scattering of microwave radiation. Some of the key components of the CTS are quasi-optical mirrors that are used to produce astigmatic beam patterns, which have impact on the strength and spatial resolution of the diagnostic signal. The mirrors are exposed to neutron radiation, which may alter the quality of the signal received. In this work, three different materials (molybdenum (Mo), stainless steel 316 (SS-316) and tungsten (W)) are considered for the first mirror of the CTS. The objective is to access which of the material studied are best suited for this mirror, considering different neutron radiation loads simulated scenarios defined by ITER, based on the resultant stresses and temperature distributions. For it, the neutron irradiation, and subsequent heat-load on the mirrors are simulated using the Monte Carlo N-Particle (MCNP) code. Based on the MCNP heat-load results, transient thermal-structural Finite Element Analysis (FEA) of the mirror over a 400 s discharge, with and without cooling on the rear side, are conducted using in commercial FEA software ANSYS. Results show that of the tested materials Mo and W are the most suitable material for this application. Even though, this study does not yet consider the variation of the material properties with temperature, it presents a quick initial satisfactory assessment that may be considered in subsequent and more complex analysis. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗