Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

ESPPU INPUT: C$^3$ within the "Linear Collider Vision"

The Linear Collider Vision calls for a Linear Collider Facility with a physics reach from a Higgs Factory to the TeV-scale with $e^+e^{-}$ collisions. One of the technologies under consideration for the accelerator is a cold-copper distributed-coupling linac capable of achieving high gradient. This technology is being pursued by the C$^3$ collaboration to understand its applicability to future colliders and broader scientific applications. In this input we share the baseline parameters for a C$^3$ Higgs-factory and the energy reach of up to 3 TeV in the 33 km tunnel foreseen under the Linear Collider Vision. Recent results, near-term plans and future R&D needs are highlighted.

43 PARTICLE ACCELERATORS↗

A Phase Matching, Adiabatic Accelerator

Tabletop accelerators are a thing of the future. Reducing their size will require scaling down electromagnetic wavelengths; however, without correspondingly high field gradients, particles will be more susceptible to phase-slippage – especially at low energy. We investigate how an adiabatically-tapered dielectric-lined waveguide could maintain phase-matching between the accelerating mode and electron bunch. We benchmark our simple model with CST and implement it into ASTRA; finally we provide a first glimpse into the beam dynamics in a phase-matching accelerator.

43 PARTICLE ACCELERATORS↗

Neutron generation using pyroelectric crystals

According to one embodiment, a method for producing a directed neutron beam includes producing a voltage of negative polarity of at least −100 keV on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal of less than about 40° C., the pyroelectric crystal having the deuterated or tritiated target coupled thereto, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using at least one of a voltage of the pyroelectric crystal, and a high gradient insulator (HGI) surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other methods are presented as well.

Tang, Vincent↗

Charged particle beam scanning using deformed high gradient insulator

Devices and methods are provided to allow rapid deflection of a charged particle beam. The disclosed devices can, for example, be used as part of a hadron therapy system to allow scanning of a target area within a patient's body. The disclosed charged particle beam deflectors include a dielectric wall accelerator (DWA) with a hollow center and a dielectric wall that is substantially parallel to a z-axis that runs through the hollow center. The dielectric wall includes one or more deformed high gradient insulators (HGIs) that are configured to produce an electric field with an component in a direction perpendicular to the z-axis. A control component is also provided to establish the electric field component in the direction perpendicular to the z-axis and to control deflection of a charged particle beam in the direction perpendicular to the z-axis as the charged particle beam travels through the hollow center of the DWA.

43 PARTICLE ACCELERATORS↗

Rugged, low-conductance, heat-flow probe

Lightweight, compact probe structure has low thermal conductance to enable accurate measurement of slight temperature gradients. Probe combines ruggedness, high precision, accuracy, and stability. Device can withstand vibration, shock, acceleration, temperature extremes, and high vacuums, and should interest industrial engineers and geologists.

Boudreau, E. J.↗

Understanding the Role of Extrinsic Impurities in Bulk Nb SRF Cavities

High gradient and high quality factor superconducting radiofrequency (SRF) cavities are essential for efficient particle acceleration in next-generation accelerators. This work demonstrates that the superconducting performance of bulk niobium can be enhanced through a controlled introduction of interstitial oxygen and nitrogen. Thermal and chemical surface treatments modify the concentration and distribution of these impurities, enabling systematic tuning of SRF cavity performance. By combining cavity RF measurements with quantitative materials characterizations, we isolate the impact of impurity concentration on BCS surface resistance and identify the mechanisms by which interstitial impurities alter the superconducting properties of niobium. We find that nitrogen is an order of magnitude more effective than oxygen in reducing BCS resistance at 16 MV/m and that the reduction arises from a combination of mean free path optimization and superconducting gap enhancement. Using these insights, we develop a predictive model that estimates cavity performance directly from room temperature sample material studies, reducing the reliance on full-scale cryogenic tests for surface treatment development. We then apply this model to explore co-doping strategies, demonstrating that combining interstitial oxygen and nitrogen achieves a synergistic reduction in BCS resistance. These results establish co-doping as a viable path for the development of surface-engineered niobium for future high quality factor SRF applications.

Hu, Hannah [Chicago U.]↗

High-throughput fabrication and semi-automated characterization of oxide thin film transistors

High throughput experimental methods are known to accelerate the rate of research, development, and deployment of electronic materials. For example, thin films with lateral gradients in composition, thickness, or other parameters have been used alongside spatiallyresolved characterization to assess how various physical factors affect material properties under varying measurement conditions. Similarly, multi-layer electronic devices that contain such graded thin films as one or more of their layers can also be characterized spatially in order to optimize the performance. In this work, we apply these high throughput experimental methods to thin film transistors (TFTs), demonstrating combinatorial device fabrication and semiautomated characterization using sputtered oxide TFTs as a case study. Here, we show that both extrinsic and intrinsic types of device gradients can be generated in a TFT library, such as channel thickness and length, channel cation compositions, and oxygen atmosphere during deposition. We also present a semi-automated method to measure the 44 devices fabricated on a 50x50mm substrate that can help to identify properly functioning TFTs in the library and finish the measurement in a short time. Finally, we propose a fully automated characterization system for similar TFT libraries, which can be coupled with high throughput data analysis. These results demonstrate that high throughput methods can accelerate the investigation of TFTs and other electronic devices.

36 MATERIALS SCIENCE↗

Distributed coupling and multi-frequency microwave accelerators

A microwave circuit for a linear accelerator has multiple metallic cell sections, a pair of distribution waveguide manifolds, and a sequence of feed arms connecting the manifolds to the cell sections. The distribution waveguide manifolds are connected to the cell sections so that alternating pairs of cell sections are connected to opposite distribution waveguide manifolds. The distribution waveguide manifolds have concave modifications of their walls opposite the feed arms, and the feed arms have portions of two distinct widths. In some embodiments, the distribution waveguide manifolds are connected to the cell sections by two different types of junctions adapted to allow two frequency operation. The microwave circuit may be manufactured by making two quasi-identical parts, and joining the two parts to form the microwave circuit, thereby allowing for many manufacturing techniques including electron beam welding, and thereby allowing the use of un-annealled copper alloys, and hence greater tolerance to high gradient operation.

43 PARTICLE ACCELERATORS↗

Analysis of field errors for LARP Nb 3 Sn HQ03 quadrupole magnet

The U.S. LHC Accelerator Research Program, in close collaboration with CERN, has developed three generations of high-gradient quadrupole (HQ) Nb 3 Sn model magnets, to support the development of the 150 mm aperture Nb 3 Sn quadrupole magnets for the High-Luminosity LHC. The latest generation, HQ03, featured coils with better uniformity of coil dimensions and properties than the earlier generations. We tested the HQ03 magnet at FNAL, including the field quality study. The profiles of low-order harmonics along the magnet aperture observed at 15 kA, 1.9 K can be traced back to the assembled coil pack before the magnet assembly. Based on the measured harmonics in the magnet center region, the coil block positioning tolerance was analyzed and compared with earlier HQ01 and HQ02 magnets to correlate with coil and magnet fabrication. Our study the capability of correcting the low-order non-allowed field errors, magnetic shims were installed in HQ03. Furthermore, the expected shim contribution agreed well with the calculation. For the persistent-current effect, the measured a4 can be related to 4% higher in the strand magnetization of one coil with respect to the other three coils. Lastly, we compare the field errors due to the inter-strand coupling currents between HQ03 and HQ02.

43 PARTICLE ACCELERATORS↗

A vectorized, finite-volume, adaptive-grid algorithm for Navier-Stokes calculations

An adaptive grid, finite-volume method has been used to solve the Navier-Stokes equations for complete (forebody and afterbody) flowfields around blunt bodies. The code, which is applicable for axisymmetric or two-dimensional flows, allows the mesh to adjust during the computation to provide a closer spacing of mesh points in regions of high gradients, thus minimizing the number of required computational points. The solution technique is explicit, utilizing a maximum time-step advancement at each grid point to accelerate convergence to the steady state. The code has been fully vectorized for efficient solution on the CYBER 203 computer. A very flexible rezoning routine is used to concentrate mesh points anywhere in the field, either by a user-defined weighting function or by allowing high gradient regions to adjust the grid. The grid adjustment routine is implicit in nature and represents a very small portion of the total computational cost. Currently, the code runs in approximately 0.000016 seconds per grid point per iteration.

Gnoffo, P. A.↗

Multi-metallic conduction cooled superconducting radio-frequency cavity with high thermal stability

Superconducting radio-frequency cavities are commonly used in modern particle accelerators for applied and fundamental research. Such cavities are typically made of high-purity, bulk Nb and with cooling by a liquid helium bath at a temperature of ~2 K. The size, cost and complexity of operating a particle accelerator with a liquid helium refrigerator make the current cavity technology not favorable for use in industrial-type accelerators. We have developed a multi-metallic 1.495 GHz elliptical cavity conductively cooled by a cryocooler. The cavity has a ~2 µm thick layer of Nb 3 Sn on the inner surface, exposed to the rf field, deposited on a ~3 mm thick bulk Nb shell and a bulk Cu shell, of thickness $\geqslant\! 5$ mm deposited on the outer surface by electroplating. A bolt-on Cu plate 1.27 cm thick was used to thermally connect the cavity equator to the second stage of a Gifford-McMahon cryocooler with a nominal capacity of 2 W at 4.2 K. The cavity was tested initially in liquid helium at 4.3 K and reached a peak surface magnetic field of ~36 mT with a quality factor of 2 × 10 9 . The cavity cooled by the cryocooler achieved a peak surface magnetic field of ~29 mT, equivalent to an accelerating gradient of 6.5 MV m –1 . The conduction-cooled cavity could be operated in continuous-wave with as high as 5 W dissipation in the cavity for 1 h without any thermal breakdown, because of the Cu outer layer with high thermal conductivity. This result represents a paradigm shift in the technology of superconducting accelerator cavities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultra-high quality factors in superconducting niobium cavities in ambient magnetic fields up to 190 mG

Ambient magnetic field, if trapped in the penetration depth, leads to the residual resistance and therefore sets the limit for the achievable quality factors in superconducting niobium resonators for particle accelerators. Here, we show that a complete expulsion of the magnetic flux can be performed and leads to: (1) record quality factors Q > 2 × 10{sup 11} up to accelerating gradient of 22 MV/m; (2) Q ∼ 3 × 10{sup 10} at 2 K and 16 MV/m in up to 190 mG magnetic fields. This is achieved by large thermal gradients at the normal/superconducting phase front during the cooldown. Our findings open up a way to ultra-high quality factors at low temperatures and show an alternative to the sophisticated magnetic shielding implemented in modern superconducting accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vacuum RF Breakdown of Accelerating Cavities in Multi-Tesla Magnetic Fields

Ionization cooling of intense muon beams requires the operation of high-gradient, normal-conducting RF structures within multi-Tesla magnetic fields. The application of strong magnetic fields has been shown to lead to an increase in vacuum RF breakdown. This phenomenon imposes operational (i.e. gradient) limitations on cavities in ionization cooling channels, and has a bearing on the design and operation of other RF structures as well, such as photocathodes and klystrons. We present recent results from Fermilab's MuCool Test Area (MTA), in which 201 and 805 MHz cavities were operated at high power both with and without the presence of multi-Tesla magnetic fields. We present an analysis of damage due to breakdown in these cavities, as well as measurements related to dark current and their relation to a conceptual model describing breakdown phenomena.

43 PARTICLE ACCELERATORS↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

SU-F-BRF-08: Conformal Mapping-Based 3D Surface Matching and Registration

Purpose: Recently, non-rigid 3D surface matching and registration has been used extensively in engineering and medicine. However, matching 3D surfaces undergoing non-rigid deformation accurately is still a challenging mathematical problem. In this study, we present a novel algorithm to address this issue by introducing intrinsic symmetry to the registration Methods: Our computational algorithm for symmetric conformal mapping is divided into three major steps: 1) Finding the symmetric plane; 2) Finding feature points; and 3) Performing cross registration. The key strategy is to preserve the symmetry during the conformal mapping, such that the image on the parameter domain is symmetric and the area distortion factor on the parameter image is also symmetric. Several novel algorithms were developed using different conformal geometric tools. One was based on solving Riemann-Cauchy equation and the other one employed curvature flow Results: Our algorithm was implemented using generic C++ on Windows XP and used conjugate gradient search optimization for acceleration. The human face 3D surface images were acquired using a high speed 3D scanner based on the phase-shifting method. The scanning speed was 30 frames/sec. The image resolution for each frame was 640 × 480. For 3D human face surfaces with different expressions, postures, and boundaries, our algorithms were able to produce consistent result on the texture pattern on the overlapping region Conclusion: We proposed a novel algorithm to improve the robustness of conformal geometric methods by incorporating the symmetric information into the mapping process. To objectively evaluate its performance, we compared it with most existing techniques. Experimental results indicated that our method outperformed all the others in terms of robustness. The technique has a great potential in real-time patient monitoring and tracking in image-guided radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conduction Cooling of a Niobium SRF Cavity Using a Cryocooler

Superconducting Radio Frequency (SRF) cavities are the primary choice for accelerating charged particles in high-energy research accelerators. Institutions like Fermilab use SRF cavities because they enable significantly higher gradients and quality factors than normal-conducting RF cavities and DC voltage cavities. To cool the SRF cavities to low temperatures (typically around 2 K), liquid helium refrigerators are used. Producing and maintaining the necessary liquid helium requires large, elaborate cryogenic plants involving dewars, compressors, expansion engines, and recyclers. The cost, complexity, and space required for such plants is part of the reason that industry has not yet adopted SRF-based accelerators. At the Illinois Accelerator Research Center (IARC) at Fermilab, our team seeks to make SRF technology accessible not only to large research accelerators, but to industry as well. If we eliminate the complexity associated with liquid helium plants, SRF-based industrial accelerators may finally become a reality. One way to do this is to eliminate the use of liquid helium baths altogether and develop a brand-new cooling technique for SRF cavities: conduction cooling using a cryocooler. Recent advances in SRF technology have made it possible to operate SRF cavities at 4 K, a temperature easily achievable using commercial cryocoolers. Our IARC team is taking advantage of this technology to cool SRF cavities.

43 PARTICLE ACCELERATORS↗

Cryogenic testing of the 2.1 GHz five-cell superconducting RF cavity with a photonic band gap coupler cell

We present results from cryogenic tests of the multi-cell superconducting radio frequency (SRF) cavity with a photonic band gap (PBG) coupler cell. Achieving high average beam currents is particularly desirable for future light sources and particle colliders based on SRF energy-recovery-linacs (ERLs). Beam current in ERLs is limited by the beam break-up instability, caused by parasitic higher order modes (HOMs) interacting with the beam in accelerating cavities. A PBG cell incorporated in an accelerating cavity can reduce the negative effect of HOMs by providing a frequency selective damping mechanism, thus allowing significantly higher beam currents. The multi-cell cavity was designed and fabricated of niobium. Two cryogenic (vertical) tests were conducted. The high unloaded Q-factor was demonstrated at a temperature of 4.2 K at accelerating gradients up to 3 MV/m. The measured value of the unloaded Q-factor was 1.55 × 10<8>, in agreement with prediction.

43 PARTICLE ACCELERATORS↗