Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Hand Held Device for Wireless Powering and Interrogation of Biomems Sensors and Actuators

A compact, hand-held device for wireless powering, interrogation and data retrieval from at least one implanted sensor. The hand-held device includes an antenna for powering an implanted sensor and for receiving data from the implanted sensor to the hand-held device for at least one of storage, display or analysis. The hand-held device establishes electromagnetic coupling with a low radiating radio frequency power inductor in the implanted sensor at a predefined separation and the antenna geometry allows for the antenna to power, interrogate and retrieve data from the implanted sensor without strapping the hand-held device to a human body housing the implanted sensor The hand-held device optionally allows for activation of the implanted sensor only during interrogation and data retrieval.

Miranda, Felix Antonio↗

The Statistical Mechanics of Solar Wind Hydroxylation at the Moon, Within Lunar Magnetic Anomalies, and at Phobos

We present a new formalism to describe the outgassing of hydrogen initially implanted by the solar wind protons into exposed soils on airless bodies. The formalism applies a statistical mechanics approach similar to that applied recently to molecular adsorption onto activated surfaces. The key element enabling this formalism is the recognition that the interatomic potential between the implanted H and regolith-residing oxides is not of singular value but possess a distribution of trapped energy values at a given temperature, F(U,T). All subsequent derivations of the outward diffusion and H retention rely on the specific properties of this distribution. We find that solar wind hydrogen can be retained if there are sites in the implantation layer with activation energy values exceeding 0.5eV. We especially examine the dependence of H retention applying characteristic energy values found previously for irradiated silica and mature lunar samples. We also apply the formalism to two cases that differ from the typical solar wind implantation at the Moon. First, we test for a case of implantation in magnetic anomaly regions where significantly lower-energy ions of solar wind origin are expected to be incident with the surface. In magnetic anomalies, H retention is found to be reduced due to the reduced ion flux and shallower depth of implantation. Second, we also apply the model to Phobos where the surface temperature range is not as extreme as the Moon. We find the H atom retention in this second case is higher than the lunar case due to the reduced thermal extremes (that reduces outgassing).

Solar Wind↗

Skeletal response to corticosteroid deficiency and excess in growing male rats

The study was designed to investigate bone histomorphometric changes induced by corticosteroid deficiency and supplementation at different dose levels in the rat skeleton. Male rats were adrenalectomized (ADX) or sham-operated and divided into six groups. At 2 days after surgery, sham-operated control rats (CON + PLA) and one group of ADX rats (ADX + PLA) were implanted subcutaneously (s.c.) with placebo pellets. ADX rats in the remaining four groups (ADX + C25, ADX + C50, ADX + C100, and ADX + C300) were implanted sc with corticosterone pellets designed to release 25, 50, 100, or 300 mg of the hormone over a 60 day period. Each ADX rat was also implanted sc with an aldosterone pellet (2.5 mg) similarly designed to release its contents over the same time period. All rats were killed at 3 weeks after implantation of pellets. Terminal blood samples were collected for serum biochemistry and the proximal tibial metaphyses (PTM), tibial diaphyses, and first lumbar vertebrae (LV) were processed undecalcified for quantitative bone histomorphometry. A dose-dependent increase in serum corticosterone concentration was observed in ADX rats implanted with hormone pellets. In comparison to CON + PLA rats, ADX + PLA rats had lower cancellous bone volume associated with a stimulation in longitudinal bone growth, an increase in mineral apposition rate, and a trend for increased osteoclast and osteoblast surfaces in PTM. In contrast, cancellous bone of ADX + C25 rats was preserved at nearly the CON + PLA level. However, the higher doses of corticosterone increased cancellous bone mass, but decreased longitudinal bone growth and all indices of bone resorption and formation in a dose-dependent manner in PTM. Similar cancellous bone changes were observed in the LV of corticosterone-treated rats, with the exception of a lack of an hormonal effect on cancellous bone mass. In the tibial diaphysis, corticosterone inhibited periosteal bone formation in a dose-dependent manner, but did not affect cortical bone mass. The results indicate that corticosteroid deficiency induces cancellous osteopenia, whereas supplementation with a near physiologic dose of the hormone prevents this bone loss in ADX rats. Furthermore, corticosteroid excess inhibits bone growth and bone turnover in a dose-dependent manner, but does not induce cancellous osteopenia in growing male rats.

Non-NASA Center↗

Mechanisms of alpha 1-adrenergic vascular desensitization in conscious dogs

To investigate the mechanisms of alpha 1-adrenergic vascular desensitization, osmotic minipumps containing either saline (n = 9) or amidephrine mesylate (AMD) (n = 9), a selective alpha 1-adrenergic receptor agonist, were implanted subcutaneously in dogs with chronically implanted arterial and right atrial pressure catheters and aortic flow probes. After chronic alpha 1-adrenergic receptor stimulation, significant physiological desensitization to acute AMD challenges was observed, i.e., pressor and vasoconstrictor responses to the alpha 1-adrenergic agonist were significantly depressed (p < 0.01) compared with responses in the same dogs studied in the conscious state before pump implantation. However, physiological desensitization to acute challenges of the neurotransmitter norepinephrine (NE) (0.1 micrograms/kg per minute) in the presence of beta-adrenergic receptor blockade was not observed for either mean arterial pressure (MAP) (30 +/- 7 versus 28 +/- 5 mm Hg) or total peripheral resistance (TPR) (29.8 +/- 4.9 versus 28.9 +/- 7.3 mm Hg/l per minute). In the presence of beta-adrenergic receptor plus ganglionic blockade after AMD pump implantation, physiological desensitization to NE was unmasked since the control responses to NE (0.1 micrograms/kg per minute) before the AMD pumps were now greater (p < 0.01) than after chronic AMD administration for both MAP (66 +/- 5 versus 32 +/- 2 mm Hg) and TPR (42.6 +/- 10.3 versus 23.9 +/- 4.4 mm Hg/l per minute). In the presence of beta-adrenergic receptor, ganglionic, plus NE-uptake blockade after AMD pump implantation, desensitization was even more apparent, since NE (0.1 micrograms/kg per minute) induced even greater differences in MAP (33 +/- 5 versus 109 +/- 6 mm Hg) and TPR (28.1 +/- 1.8 versus 111.8 +/- 14.7 mm Hg/l per minute). The maximal force of contraction induced by NE in the presence or absence of endothelium was significantly decreased (p < 0.05) in vitro in mesenteric artery rings from AMD pump dogs compared with saline control dogs. Furthermore, alpha 1-adrenergic receptor density, as determined by [3H]prazosin binding in membrane preparations from vessels in the mesentery, was decreased (8.2 +/- 1.0 versus 18.4 +/- 1.4 fmol/mg protein, p < 0.001) without any change in Kd in the AMD pump dogs compared with the saline pump dogs.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Development of GaAs solar cells

Solar cells and mesa diodes were fabricated by the implantation of zinc or beryllium ions into n-type gallium arsenide. Annealing temperatures above 750 C (zinc) or 650 C (beryllium) were found to produce 50% to 100% activation of the implanted ions. Junction depths of about 0.4 micron were produced by 600 keV zinc implants or 70 keV beryllium implants. P-layer sheet resistance was about 150 ohms for 2 x 10 to the 15th power cm/2 zinc or 1 x 10 to the 15th power cm/2 beryllium implants. This is sufficiently low for efficient solar cell fabrication. Contacting procedures were improved to yield reproducibly adherent, low resistance front and back contacts.

Source record↗

Development of pulsed processes for the manufacture of solar cells

The results of a 1-year program to develop the processes required for low-energy ion implantation for the automated production of silicon solar cells are described. The program included: (1) demonstrating state-of-the-art ion implantation equipment and designing an automated ion implanter, (2) making efforts to improve the performance of ion-implanted solar cells to 16.5 percent AM1, (3) developing a model of the pulse annealing process used in solar cell production, and (4) preparing an economic analysis of the process costs of ion implantation.

Minnucci, J. A.↗

Lunar Magnetic Fields: Implications for Resource Utilization

It is well known that solar-wind-implanted hydrogen and helium-3 in lunar soils are potentially usable resources for future manned activities. For economical mining of these implanted gases, it is desirable that relative concentrations exceed that of typical soils. It has previously been noted that the monthly variation of solar wind flux on the surface due to lunar immersion in the geomagnetic tail may have measurable consequences for resource utilization. It is pointed out that, for a constant external flux, locally strong lunar crustal magnetic fields will exert the dominant influence on solar wind volatile implantation rates. In particular, the strongest lunar crustal magnetic fields will both deflect and focus incident ions in local regions leading to local enhancements of the incident ion flux. Thus, the most economical sites for extraction of solar-wind-implanted volatiles may be within or adjacent to strong crustal magnetic fields. In addition, solar wind ion deflection by crustal magnetic fields must be considered in evaluating the issue of whether remnant cometary ice or water-bearing minerals have survived in permanently shadowed regions near the lunar poles. This is because sputter erosion of water ice by solar wind ions has been suggested to be an important ice loss mechanism within permanently shadowed regions. Thus, permanently shadowed regions that are also shielded from the solar wind by locally strong crustal fields could be the most promising locations for the survival of cometary ice. Additional numerical simulations are employed to show that solar wind ion deflection by strong lunar magnetic anomalies can produce local increases in the implantation rate of solar wind gases such as hydrogen.

Hood, L. L.↗

Intrauterine Pressure (IUP) Telemetry in Pregnant and Parturient Rats: Potential Applications for Spacecraft and Centrifugation Studies

Rats exposed to spaceflight or centrifugation from mid-to late pregnancy undergo either more or fewer labor contractions at birth, respectively, as compared to those in normal Earth gravity (1-g). In this paper, we report the development and validation of a new telemetric method for quantifying intrauterine pressure (IUP) in freely-moving, late pregnant and parturient rats. We plan to utilize this technique for studies of labor in altered gravity, specifically, to ascertain forces of uterine during birth, which we believe may be changed in micro- and hypergravity. The technique we describe yields precise, reliable measures of the forces experienced by rat fetuses during parturition. A small, surgically-implantable telemetric pressure sensor was fitted within a fluid-filled balloon. The total volume of the sensor-balloon assembly matched that of a full term rat fetus. Real-time videorecordings of sensor-implanted rat dams and non- implanted control dams enabled us to characterize effects of the intrauterine implant on behavioral aspects of parturition. Contraction frequency, duration, pup-to-pup birth intervals and pup-oriented activities of the dams measured during the peri-birth period were unaffected by the sensor implant. These findings establish intrauterine telemetry as a reliable, non-invasive technique for quantifying intrauterine pressures associated with parturition on Earth and in altered gravity environments. This new technology, readily amenable to spaceflight and centrifugation platforms, will enable us to answer key questions regarding the role of altered labor frequency labor in the adaptation of newborn mammals to hypo- and hypergravity.

Ronca, A. E.↗

On the origins of trapped helium, neon and argon isotopic variations in meteorites. I - Gas-rich meteorites, lunar soil and breccia. II - Carbonaceous meteorites.

Data are presented from stepwise heating experiments and total extractions on five meteorites: Kapoeta, Fayetteville, Holman Island, Cee Vee, and Pultusk. These data reveal the presence of four isotopically distinct trapped neon components. A comparison of trapped neon with trapped helium and argon in bulk analyses indicates the existence of correlated helium, neon and argon isotopic structures. Component B is attributed primarily to direct implantation of rare gas ions by the present day solar wind. Component C is identified with directly implanted low energy (1-10 Mev/n) solar flare rare gases. Component D is associated with rare gas ions implanted in meteoritic material by the primitive, pre-main sequence, solar wind. A fourth component, observed only in Kapoeta and the lunar fines and breccia, is tentatively attributed to parent body 'atmospheric' ions implanted in surface material by a solar wind induced electric field.

Black, D. C.↗

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic pros-thesis fixtion, and dental implants.

Banks, B. A.↗

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic prosthesis fixation, and dental implants.

Banks, B. A.↗

The effect of oxidation-expanded defects upon MOS parameters

Implantation of Ne ions was chosen as a means of introducing a uniformly distributed quantitatively controllable and reproducible amount of microdefects at the silicon surface. Each wafer was ion-implanted on one half of its surface, the other half remaining as a control. Seven implant fluences from 1 trillion to 5 by 10 to the 14th power Ne ions/sq cm were used. The fluences, as well as the concentrations of defects expanded by the subsequent gate oxidation, were correlated with seven different MOS parameters. For implant fluences of 10 to the 14th power per sq cm and above, increasing stacking-fault densities were found. The oxide defect density associated with time-dependent breakdown increased significantly with Ne dose. The presence of oxidation-expanded defects drastically increases the surface-generation velocity and decreases the bulk lifetime. Slight increases in flatband voltage and surface-state density occurred only for the wafers having the greatest defect concentrations. Oxidation of a P-containing damaged silicon surface results in a greater pileup of P at the surface than occurs for the oxidation of a similar but undamaged surface. It appears that the expanding defects restrain the diffusion of P inward from the surface.

Prussin, S.↗

Single frequency RF powered ECG telemetry system

It has been demonstrated that a radio frequency magnetic field can be used to power implanted electronic circuitry for short range telemetry to replace batteries. A substantial reduction in implanted volume can be achieved by using only one RF tank circuit for receiving the RF power and transmitting the telemetered information. A single channel telemetry system of this type, using time sharing techniques, was developed and employed to transmit the ECG signal from Rhesus monkeys in primate chairs. The signal from the implant is received during the period when the RF powering radiation is interrupted. The ECG signal is carried by 20-microsec pulse position modulated pulses, referred to the trailing edge of the RF powering pulse. Satisfactory results have been obtained with this single frequency system. The concept and the design presented may be useful for short-range long-term implant telemetry systems.

Ko, W. H.↗

Carbon isotopic ratios in some low-delta N-15 lunar breccias

Lunar soil breccias 10018, 79035 and 79135 were analyzed for carbon and nitrogen contents and isotopic compositions by vacuum pyrolysis, with a 500 C pre-combustion step in some cases. The combustion was used to remove carbon of terrestrial origin. Nitrogen isotopic ratios for the breccias are very low and are in agreement with results in the literature. Nitrogen yields in two cases were lower than literature values, a result attributable to heterogeneous mixing of implanted and implantation-free components in the breccias. Carbon isotopic ratios were found to be low in these breccias, even when reasonable account is taken of terrestrial carbon contamination. The results are consistent with the idea that low-delta N-15 values in lunar soils and breccias are accompanied by low-delta C-13 values, and imply that any secular variation which occurred in the delta N-15 of nitrogen implanted in lunar soils was accompanied by a similar but smaller variation in the delta C-13 of implanted carbon.

Becker, R. H.↗

Development and fabrication of a solar cell junction processing system

A processing system capable of producing solar cell junctions by ion implantation followed by pulsed electron beam annealing was developed and constructed. The machine was to be capable of processing 4-inch diameter single-crystal wafers at a rate of 10(7) wafers per year. A microcomputer-controlled pulsed electron beam annealer with a vacuum interlocked wafer transport system was designed, built and demonstrated to produce solar cell junctions on 4-inch wafers with an AMI efficiency of 12%. Experiments showed that a non-mass-analyzed (NMA) ion beam could implant 10 keV phosphorous dopant to form solar cell junctions which were equivalent to mass-analyzed implants. A NMA ion implanter, compatible with the pulsed electron beam annealer and wafer transport system was designed in detail but was not built because of program termination.

Source record↗

Ion Implantatiion Improves Bearing-Surface Properties

Selected ions fired into rolling elements to increase resistance to rolling-contact fatique. Mask strips confine implantation to 105 degree arcs on cylindrical surfaces. Specimens kept cool by copper block through which refrigerant is circulated. Implanting nitrogen or titanium ions in metals improves resistance to fatigue, corrosion, and wear without altering bulk properties. Unlike such surface treatments as conventional nitriding, conventional carburizing, and coating, ion implantation is low-temperature process, requires no finishing operations, and produces highly-alloyed surface layer. Implantation process also helps conserve such strategic materials as chromium and cobalt by using them only where needed.

Misra, M. S.↗

Phase transformations in ion-irradiated silicides

The present investigation has three objectives. The first is concerned with the phase transformation of CoSi2 under ion implantation and the subsequent crystallization characteristics during annealing, taking into account epitaxial and nonepitaxial recrystallization behavior. The second objective is related to a study of the general trend of implantation-induced damage and crystallization behavior for a number of commonly used silicides. The last objective involves a comparison of the recrystallization behavior of cosputtered refractory silicides with that of the ion-implanted silicides. It was found that epitaxial regrowth of ion-irradiated CoSi2 occurred for samples with an epitaxial seed left at the Si/CoSi2 interface. A structural investigation of CoSi2 involving transmission electron microscopy (TEM) showed that after high-dose implantation CoSi2 is amorphous.

Hewett, C. A.↗

Amorphization and recrystallization of epitaxial ReSi2 films grown on Si(100)

The effects of implantation damage and the chemical species of the implant on structural and electrical properties of epitaxial ReSi2 films on Si(100) implanted with Si-28 or Ar-40 ions, at doses ranging from 10 to the 13th/sq cm to 10 to the 15th/sq cm, were investigated using the backscattering spectrometry, XRD, and the van der Pauw techniques. Results showed that ion implantation produces damage in the film, which increases monotonically with dose; the resistivity of the film decreases monotonically with dose.

Kim, Kun HO↗