Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Comparison of machine learning systems trained to detect Alfvén eigenmodes using the CO 2 interferometer on DIII-D

Abstract A Machine-Learning (ML) based detection scheme that automatically detects Alfvén Eigenmodes (AE) in a labelled DIII-D database is presented here. Controlling AEs is important for the success of planned burning plasma devices such as ITER, since resonant fast ions can drive AEs unstable and degrade the performance of the plasma or damage the first walls of the machine vessel. Artificial Intelligence could be useful for real-time detection and control of AEs in steady-state plasma scenarios by implementing ML-based models into control algorithms that drive actuators for mitigation of AE impacts. Thus, the objective is to compare differences in performance between using two different recurrent neural network systems (Reservoir Computing Network and Long Short Term Memory Network) and two different representations of the C O 2 phase data (simple and crosspower spectrograms). All C O 2 interferometer chords are used to train both models, but only one is processed during each training step. The results from the model and data comparison show higher performance for the RCN model (True Positive Rate = 90% and False Positive Rate = 14%), and that using simple magnitude spectrograms is sufficient to detect AEs. Also, the vertical C O 2 interferometer chord passing near the center is better for ML-based detection of AEs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resolution and sensitivity of a Fabry-Perot interferometer with a photon-number-resolving detector

With photon-number resolving detectors, we show compression of interference fringes with increasing photon numbers for a Fabry-Perot interferometer. This feature provides a higher precision in determining the position of the interference maxima compared to a classical detection strategy. We also theoretically show supersensitivity if N-photon states are sent into the interferometer and a photon-number resolving measurement is performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct observation of geometric phases using a three-pinhole interferometer

We present a method to measure the geometric phase defined for three internal states of a photon (polarizations) using a three-pinhole interferometer. From the interferogram, we can extract the geometric phase related to the three-vertex Bargmann invariant as the area of a triangle formed by interference fringes. Unlike the conventional methods, our method does not involve the state evolution. Moreover, the phase calibration of the interferometer and the elimination of the dynamical phase are not required. The gauge invariance of the geometric phase corresponds to the fact that the area of the triangle is never changed by the local phase shift in each internal state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comment on ''Rovibrational quantum interferometers and gravitational waves''

In a recent paper, Wicht, Laemmerzahl, Lorek, and Dittus [Phys. Rev. A 78, 013610 (2008)] come to the conclusion that a molecular rotational-vibrational quantum interferometer may possess the sensitivity necessary to detect gravitational waves. We do not agree with their results and demonstrate here that the true sensitivity of such an interferometer is many orders of magnitude worse than that claimed in the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous phase amplification with a Sagnac interferometer

We describe a phase-amplification technique using a Sagnac interferometer. We monitor the relative phase between two paths of a precisely misaligned interferometer by measuring the average position of a split-Gaussian mode in the dark port. Although we monitor only the dark port, we show that the signal varies linearly with phase and that we can obtain similar sensitivity to balanced homodyne detection. We derive the source of the amplification using classical wave optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical simulation of a multilevel atom interferometer

We present a comprehensive numerical simulation of an echo-type atom interferometer. The simulation confirms an interesting theoretical description of this interferometer that includes effects due to spontaneous emission and magnetic sublevels. Both the simulation and the theoretical model agree with the results of experiments. These developments provide an improved understanding of several observable effects. The evolution of state populations due to stimulated emission and absorption during the standing-wave interaction imparts a time-dependent phase on each atomic momentum state. This manifests itself as an asymmetry in the signal shape that depends on the strength of the interaction as well as spontaneous emission due to a nonzero population in the excited states. The degree of asymmetry is a measure of a nonzero relative phase between interfering momentum states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal calcium atom interferometer with a phase resolution of a few milliradians based on a narrow-linewidth diode laser

A symmetrical atom interferometer with a thermal calcium atom beam has been developed using a narrow linewidth diode laser stabilized to the resonance of a high-finesse cavity. The linewidth of the diode laser was estimated to be less than 1 Hz relative to the cavity resonance in noise measurement over the range of 100 Hz to 1 MHz, and the phase instability of the interference fringes obtained from the Allan deviation was improved to 2 mrad at an integration time of 300 s. Using this atom interferometer, the ac Stark phase shift between the {sup 1}S{sub 0} and {sup 3}P{sub 1} states of a Ca atom was measured as a function of a laser power near the resonance of the {sup 1}S{sub 0}-{sup 1} P{sub 1} transition at a wavelength of 423 nm. The decay rate of the {sup 1}P{sub 1} state was determined to be {gamma}=1.91(33)x10{sup 8} s{sup -1}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of a free oscillation atom interferometer

We analyze a Bose-Einstein condensate (BEC)-based free oscillation atom Michelson interferometer in a weakly confining harmonic magnetic trap. A BEC at the center of the trap is split into two harmonics by a laser standing wave. The harmonics move in opposite directions with equal speeds and turn back under the influence of the trapping potential at their classical turning points. The harmonics are allowed to pass through each other and a recombination pulse is applied when they overlap at the end of a cycle after they return for the second time. We derive an expression for the contrast of the interferometric fringes and obtain the fundamental limit of performance of the interferometer in the parameter space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Manipulation of the resonance interaction in Mach-Zehnder-Fano interferometers

We study tunable interaction of the resonances in the Mach-Zehnder-Fano interferometers (MZFIs). A discrete Mach-Zehnder interferometer (MZI) with balanced arms supports bound states in the continuum. We demonstrate that doping an impurity in conventional MZIs gives rise to robust high-Q Fano resonances with asymmetric line shapes. By means of the modified Fano-Anderson model and the scattering-matrix approach, we show that the transmission and the intensity spectra of the whole system are very sensitive to both the location and the strength of the impurity. The side-coupled Fano defects induce an interaction with different eigenmodes of the pure MZI loop. We explore this interaction by tuning the parameters of the Fano defects. The observed resonance interaction can be attributed to the Fano-Feshbach resonance. We further provide with a particular physical example of photonic crystal circuit the applicability of our concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototyping method for Bragg-type atom interferometers

We present a method for rapid modeling of new Bragg ultracold atom-interferometer (AI) designs useful for assessing the performance of such interferometers. The method simulates the overall effect on the condensate wave function in a given AI design using two separate elements. These are (1) modeling the effect of a Bragg pulse on the wave function and (2) approximating the evolution of the wave function during the intervals between the pulses. The actual sequence of these pulses and intervals is then followed to determine the approximate final wave function from which the interference pattern can be calculated. The exact evolution between pulses is assumed to be governed by the Gross-Pitaevskii (GP) equation whose solution is approximated using a Lagrangian variational method to facilitate rapid estimation of performance. The method presented here is an extension of an earlier one that was used to analyze the results of an experiment [J. E. Simsarian et al., Phys. Rev. Lett. 85, 2040 (2000)], where the phase of a Bose-Einstein condensate was measured using a Mach-Zehnder-type Bragg AI. We have developed both 1D and 3D versions of this method and we have determined their validity by comparing their predicted interference patterns with those obtained by numerical integration of the 1D GP equation and with the results of the above experiment. We find excellent agreement between the 1D interference patterns predicted by this method and those found by the GP equation. We show that we can reproduce all of the results of that experiment without recourse to an ad hoc velocity-kick correction needed by the earlier method, including some experimental results that the earlier model did not predict. We also found that this method provides estimates of 1D interference patterns at least four orders-of-magnitude faster than direct numerical solution of the 1D GP equation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of asymptotic expansions for maximum likelihood estimators errors to gravitational waves from binary mergers: The single interferometer case

In this paper we apply to gravitational waves (GW) from the inspiral phase of binary systems a recently derived frequentist methodology to calculate analytically the error for a maximum likelihood estimate of physical parameters. We use expansions of the covariance and the bias of a maximum likelihood estimate in terms of inverse powers of the signal-to-noise ration (SNR)s where the square root of the first order in the covariance expansion is the Cramer Rao lower bound (CRLB). We evaluate the expansions, for the first time, for GW signals in noises of GW interferometers. The examples are limited to a single, optimally oriented, interferometer. We also compare the error estimates using the first two orders of the expansions with existing numerical Monte Carlo simulations. The first two orders of the covariance allow us to get error predictions closer to what is observed in numerical simulations than the CRLB. The methodology also predicts a necessary SNR to approximate the error with the CRLB and provides new insight on the relationship between waveform properties, SNR, dimension of the parameter space and estimation errors. For example the timing match filtering can achieve the CRLB only if the SNR is larger than the Kurtosis of the gravitational wave spectrum and the necessary SNR is much larger if other physical parameters are also unknown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of Saturation of Fidelity Decay with an Atom Interferometer

We use an atom interferometer to investigate the dynamics of matter waves in a periodically pulsed optical standing wave: an atom optics realization of the quantum kicked rotor that exhibits chaotic classical dynamics. We experimentally show that a measure of the coherence between the interferometer diffraction orders can revive after a quick initial loss, and can approach a finite asymptote as the number of kicks increases. This observation demonstrates that quantum fidelity of a classically chaotic system can survive strong perturbations over long times without decay.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise-Immune Conjugate Large-Area Atom Interferometers

We present a pair of simultaneous conjugate Ramsey-Borde atom interferometers using large (20(Planck constant/2pi)k)-momentum transfer beam splitters, where (Planck constant/2pi)k is the photon momentum. Simultaneous operation allows for common-mode rejection of vibrational noise. This allows us to surpass the enclosed space-time area of previous interferometers with a splitting of 20(Planck constant/2pi)k by a factor of 2500. Using a splitting of 10(Planck constant/2pi)k, we demonstrate a 3.4 ppb resolution in the measurement of the fine structure constant. Examples for applications in tests of fundamental laws of physics are given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice Interferometer for Laser-Cooled Atoms

We demonstrate an atom interferometer in which atoms are laser cooled into a 1D optical lattice, suddenly released, and later subjected to a pulsed optical lattice. For short pulses, a simple analytical theory predicts the signal. We investigate both short and longer pulses where the analytical theory fails. Longer pulses yield higher precision and larger signals, and we observe a coherent signal at times that can differ significantly from the expected echo time. The interferometer has potential for precision measurements of (Planck constant/2pi)/m{sub A}, and can probe the dynamics of atoms in an optical lattice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the Area of a Raman Atom Interferometer Using a Versatile Double-Diffraction Technique

In this Letter, we demonstrate a new scheme for Raman transitions which realize a symmetric momentum-space splitting of 4(Planck constant/2pi)k, deflecting the atomic wave packets into the same internal state. Combining the advantages of Raman and Bragg diffraction, we achieve a three pulse state labeled an interferometer, intrinsically insensitive to the main systematics and applicable to all kinds of atomic sources. This splitting scheme can be extended to 4N(Planck constant/2pi)k momentum transfer by a multipulse sequence and is implemented on a 8(Planck constant/2pi)k interferometer. We demonstrate the area enhancement by measuring inertial forces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-Dimensional X-Ray Grating Interferometer

We report on the design and experimental realization of a 2D x-ray grating interferometer. We describe how this interferometer has been practically implemented, discuss its performance, and present multidirectional scattering (dark-field) maps and quantitative phase images that have been retrieved using this device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗