At least 325 records · Page 18

Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors’ holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strongly enhanced oxygen ion transport through samarium-doped CeO 2 nanopillars in nanocomposite films

Enhancement of oxygen ion conductivity in oxides is important for low-temperature (<500 °C) operation of solid oxide fuel cells, sensors and other ionotronic devices. While huge ion conductivity has been demonstrated in planar heterostructure films, there has been considerable debate over the origin of the conductivity enhancement, in part because of the difficulties of probing buried ion transport channels. Here we create a practical geometry for device miniaturization, consisting of highly crystalline micrometre-thick vertical nanocolumns of Sm-doped CeO 2 embedded in supporting matrices of SrTiO 3 . The ionic conductivity is higher by one order of magnitude than plain Sm-doped CeO 2 films. By using scanning probe microscopy, we show that the fast ion-conducting channels are not exclusively restricted to the interface but also are localized at the Sm-doped CeO 2 nanopillars. This work offers a pathway to realize spatially localized fast ion transport in oxides of micrometre thickness.

30 DIRECT ENERGY CONVERSION↗

Ion-selective conformational stabilization of a disordered repeats-in-toxin protein domain

Ion-binding intrinsically disordered proteins (IDPs) recruit and bind to specific metal ions to perform critical biological functions. In proteins where ion binding and structural transitions are coupled, interactions with off-target toxic metals can dramatically disrupt protein structure and function, exemplified by lead and mercury poisoning. Understanding the complex mechanisms underlying how IDPs exclude or allow binding to different ionic species is crucial for addressing the origins of metal toxicity in biological systems. Here, we elucidate mechanisms of ion selectivity in an IDP that adopts a structure upon Ca 2+ binding. We probed ion-induced conformational changes of a repeats-in-toxin (RTX) protein domain in the presence of different ion ligands—Mg 2+ , Ca 2+ , Sr 2+ , and Ba 2+ —with chemical similarities but drastically different ionic radii. RTX adopts ion-selective conformations measured by x-ray crystallography, small-angle x-ray scattering, and circular dichroism. High-resolution x-ray structures reveal that Sr 2+ induces a nearly identical RTX structure as natively binding Ca 2+ , enabled by the intrinsic flexibility and disorder of the protein. Small-angle x-ray scattering and circular dichroism indicate that smaller Mg 2+ does not induce a significant conformational change in RTX, whereas larger Ba 2+ induces a partially folded structure. These results highlight the importance of geometric constraints imposed by protein structure in determining metal ion selectivity, yielding insights into how off-target ion binding may result in protein misfolding and malfunction.

Gudinas, Alana P. [Stanford Univ., CA (United Stat↗

Project 18-15263 X-ray Studies of Interfacial Molecular Complexes in ALSEP Back-Extraction (Research Performance Final Report)

The objective of the project was to use synchrotron X-rays to measure the molecular-scale organization of extractants, complexants, buffers, and metal ions at the organic-aqueous (liquid-liquid) interface during solvent back-extraction under conditions relevant to ALSEP (Actinide-Lanthanide Separation Process). The capability of X-ray fluorescence near total reflection (XFNTR) was extended to explore the distribution of Eu(III) between the liquid-liquid interface and bulk organic and aqueous phases which contained extractants HDEHP (bis(2-ethylhexyl) phosphoric acid) and HEHEHP (2-ethylhexyl phosphonic acid mono-2-ethylhexyl ester), the complexant DTPA (diethylene triamine pentaacetic acid), and citric and nitric acids. Although an Am-compatible sample cell was developed, extending x-ray measurements of flat liquid-liquid interfaces to the actinide Am(III) did not prove to be possible within constraints imposed by the Advanced Photon Source. However, preliminary measurements with a drop cell may eventually provide a path forward to investigate Am(III) at a liquid interface. It was also demonstrated that competitive binding that occurs during back-extraction of lanthanide ions to either a phosphoric acid extractant (DHDP, di-hexadecyl phosphate) at the liquid interface or to complexant DTPA in the bulk aqueous phase could be reversibly tuned by X-ray exposure. Separately, X-ray measurements from the liquid-vapor interface explored the role of the aqueous solubility of HDEHP and HEHEHP and their interactions with a range of lanthanides and transition metal ions. Finally, the capability of X-ray absorption spectroscopy (EXAFS) was extended to probe metal ion coordination in lanthanide ion-extractant complexes at the liquid-vapor interface. Complementary to the specific interfacial systems studied during this project, the development of x-ray techniques expands our ability to understand ion ordering at liquid interfaces.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Change in Ion Distribution Function While Crossing the Space Shuttle Wake

During the space shuttle/Spacelab 2 mission (STS-5]F) the Plasma Diagnostic Package (PDP) was placed in free flight in the vicinity of the Orbiter and provided the first opportunity to measure the midwake and far-wake regions of an orbiting spacecraft. During this period the PDP crossed the wake 4 times at downstream distances ranging from 40 m to 240 m. During each crossing a definite change in the ion-retarding potential curves was measured when the PDP was in the shuttle wake compared to the ambient ionosphere. These measurements were obtained by both the differential ion flux probe and the retarding potential analyzer instruments on the PDP. The temperature of the ions, derived from fitting the data to a Maxwellian distribution, are consistent with an enhancement during each wake crossing of as much as a factor of 2.5 (from about 0.08 eV to 0.2 eV). Such studies of plasma wakes were never before performed.

Sorensen, J. E.↗

Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) [and subsequently titled] Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022) (Final Report)

This is the Final Technical Report for the DOE Measurement Innovation grant DE-SC0017998 titled Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) and subsequently titled Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 September 2017 – 31 May 2022. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that could improve understanding of magnetic equilibrium, edge localized modes in tokamaks, and bootstrap and Pfirsch-Schlüter currents in stellarators. We have performed simulations of a novel non-hydrogen beam-based diagnostic that would determine a local value (in the plasma) of the poloidal flux function by measuring the toroidal angle of the beam particles' velocity at a detector external to the plasma. The approach is similar to that of a Heavy Ion Beam Probe (HIBP), but would be able to operate with a smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key results include: Identification of the neutral and singly charged atoms that are most appropriate for use in the beam based diagnostic and the ionization cross-sections that are important for studying the plasma edge of a large device; Development of a promising geometry for operation in which the beam is injected horizontally near the torus midplane; Implementation of simulations using banana orbit trajectories of secondary beam ions to access plasma regions that are commonly in-accessible to an HIBP diagnostic, including sample volumes near the X-point of a diverted tokamak; Assessment of the ability of the diagnostic concept (originally developed under the assumption of, and reliant on, symmetry) to work in stellarators by performing simulations with both quasi-symmetric fields and non-quasi-symmetric fields; Measurement of noise levels with a prototype detector on a stellarator and exploration of techniques to minimize effects of noise on a diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Coherence between Two Atoms beyond Q=10{sup 15}

We place two atoms in quantum superposition states and observe coherent phase evolution for 3.4x10{sup 15} cycles. Correlation signals from the two atoms yield information about their relative phase even after the probe radiation has decohered. This technique allowed a frequency comparison of two {sup 27}Al{sup +} ions with fractional uncertainty 3.7{sub -0.8}{sup +1.0}x10{sup -16}/{radical}({tau}/s). Two measures of the Q factor are reported: The Q factor derived from quantum coherence is 3.4{sub -1.1}{sup +2.4}x10{sup 16}, and the spectroscopic Q factor for a Ramsey time of 3 s is 6.7x10{sup 15}. We demonstrate a method to detect the individual quantum states of two Al{sup +} ions in a Mg{sup +}-Al{sup +}-Al{sup +} linear ion chain without spatially resolving the ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

The SUMMA superconducting magnetic mirror facility and the associated hot-ion plasma research were described. SUMMA is characterized by intense magnetic fields and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential; and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature.

Reinmann, J. J.↗

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

This report describes the SUMMA superconducting magnetic mirror facility at the NASA Lewis Research Center and the hot-ion plasma research conducted therein. SUMMA is characterized by intense magnetic fields (designed for 8.6 T at the mirrors) and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential, and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature. Two NASA University Grants were established to identify major requirements for developing these two diagnostic techniques in SUMMA.

Reinmann, J. J.↗

Electric-field noise from thermally activated fluctuators in a surface ion trap

We probe electric-field noise near the metal surface of an ion-trap chip in the temperature range from 295 to 530 K. We observe a nontrivial temperature dependence with the noise amplitude at 1 MHz frequency saturating around 500 K. Measurements of the noise spectrum reveal a 1/ f α≈1 dependence and a small decrease in α between low and high temperatures. This behavior can be explained by considering noise from a distribution of thermally activated two-level fluctuators with activation energies between 0.35 and 0.65 eV. Processes in this energy range may be relevant to understanding electric-field noise in ion traps; for example, defect motion in the solid state and surface adsorbate binding energies. Lastly, the study of these processes may aid in identification of the origin of excess electric-field noise in ion traps—a major source of ion motional decoherence limiting the performance of surface traps as quantum devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

A solar wind experiment for the solar probe mission

Electron and ion plasma measurements on Solar Probe are important, especially to elucidate the role of coronal holes as sources of the solar wind and to resolve the long debated question of the importance of wave heating within 20 solar radii to the acceleration of the solar wind. Adaptable instruments are required to cover the large dynamic range of parameters between 1 AU and 4 solar radii. The baseline mission would be improved, in some respects, by the addition of a second spacecraft, following the first by a distance of several solar radii. A spinning spacecraft would be satisfactory, but not essential, for the present objectives. Attention should be paid to having the heat shield electrically conducting. An instrument for ion and electron (but no composition) measurements would have a mass of approximately 10 kg, require 8 w of power, and generate data at a maximum rate of approximately 2 kbits/sec.

Ogilvie, K. W.↗

Redox oscillations in 18650-type lithium-ion cell revealed by in operando Compton scattering imaging

Compton scattering imaging using high-energy synchrotron x rays allows the visualization of the spatiotemporal lithiation state in lithium-ion batteries probed in operando. Here, we apply this imaging technique to the commercial 18650-type cylindrical lithium-ion battery. Our analysis of the line shapes of the Compton scattering spectra taken from different electrode layers reveals the emergence of inhomogeneous lithiation patterns during the charge-discharge cycles. Moreover, these patterns exhibit oscillations in time where the dominant period corresponds to the timescale of the charging curve.

42 ENGINEERING↗

Scanning retarding field analyzer for plasma profile measurements in the boundary of the Alcator C-Mod tokamak

A new Retarding Field Analyzer (RFA) head has been created for the outer-midplane scanning probe system on the Alcator C-Mod tokamak. The new probe head contains back-to-back retarding field analyzers aligned with the local magnetic field. One faces 'upstream' into the field-aligned plasma flow and the other faces 'downstream' away from the flow. The RFA was created primarily to benchmark ion temperature measurements of an ion sensitive probe; it may also be used to interrogate electrons. However, its construction is robust enough to be used to measure ion and electron temperatures up to the last-closed flux surface in C-Mod. A RFA probe of identical design has been attached to the side of a limiter to explore direct changes to the boundary plasma due to lower hybrid heating and current drive. Design of the high heat flux (>100 MW/m{sup 2}) handling probe and initial results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-Dimensional Holey Co 3 O 4 Nanosheets for High-Rate Alkali-Ion Batteries: From Rational Synthesis to in Situ Probing

A general template-directed strategy is developed for the controlled synthesis of two-dimensional (2D) assembly of Co 3 O 4 nanoparticles (ACN) with unique holey architecture and tunable hole sizes that enable greatly improved alkali-ion storage properties (demonstrated for both Li and Na ion storage). The as-synthesized holey ACN with 10 nm holes exhibit excellent reversible capacities of 1324 mAh/g at 0.4 A/g and 566 mAh/g at 0.1 A/g for Li and Na ion storage, respectively. The improved alkali-ion storage properties are attributed to the unique interconnected holey framework that enables efficient charge/mass transport as well as accommodates volume expansion. In situ TEM characterization is employed to depict the structural evolution and further understand the structural stability of 2D holey ACN during the sodiation process. The results show that 2D holey ACN maintained the holey morphology at different sodiation stages because Co 3 O 4 are converted to extremely small interconnected Co nanoparticles and these Co nanoparticles could be well dispersed in a Na 2 O matrix. These extremely small Co nanoparticles are interconnected to provide good electron pathway. In addition, 2D holey Co 3 O 4 exhibits small volume expansion (~6%) compared to the conventional Co 3 O 4 particles. The 2D holey nanoarchitecture represents a promising structural platform to address the restacking and accommodate the volume expansion of 2D nanosheets for superior alkali-ion storage.

2D holey assembly of nanoparticles↗

Experimental results of superimposing 9.9 GHz extraordinary mode microwaves on 2.45 GHz ECRIS plasma

Efficient production of multicharged ions has been investigated on the tandem-type ECRIS in Osaka University. According to the consideration of the accessibility conditions of microwaves to resonance and cutoff regions, it was suggested that the upper hybrid resonance (UHR) heating contributed to enhancement of ion beam intensity. In order to enhance multicharged ion beams efficiently, injecting higher frequency microwave with extraordinary (X-mode) toward UHR region has been tried. In this study, 2.45 GHz frequency microwaves are used for conventional ECR discharge, and 9.9 GHz frequency microwaves with X-mode are superimposed for UHR heating. The effects of additive microwave injection are investigated experimentally in terms of plasma parameters and electron energy distribution function (EEDF) measured by Langmuir probe and ion beam current. As the results show, it is confirmed that the electrons in the high energy region are affected by 9.9 GHz X-mode microwave injection from the detailed analysis of EEDF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lateral damage in graphene carved by high energy focused gallium ion beams

Raman mapping is performed to study the lateral damage in supported monolayer graphene carved by 30 keV focused Ga{sup +} beams. The evolution of the lateral damage is tracked based on the profiles of the intensity ratio between the D (1341 cm{sup −1}) and G (1582 cm{sup −1}) peaks (I{sub D}/I{sub G}) of the Raman spectra. The I{sub D}/I{sub G} profile clearly reveals the transition from stage 2 disorder into stage 1 disorder in graphene along the direction away from the carved area. The critical lateral damage distance spans from <1 μm up to more than 30 μm in the experiment, depending on the parameters used for carving the graphene. The wide damage in the lateral direction is attributed to the deleterious tail of unfocused ions in the ion beam probe. The study raises the attention on potential sample damage during direct patterning of graphene nanostructures using the focused ion beam technique. Minimizing the total carving time is recommended to mitigate the lateral damage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of magnetic angle on the E × B drift in a magnetic presheath

In this work, we provide experimental measurements of the E X B flow above a non-magnetic, absorbing boundary in a magnetized plasma. Measurements are taken as a function of the angle between the background magnetic field and the boundary normal. The measurements are compared to computational predictions for oblique magnetic fields based on Chodura's model. Ion flow measurements were obtained with laser induced fluorescence and the presheath potential structure was measured with an emissive probe. The ions were found to accelerate to nearly 30% of the sound speed parallel to the boundary at oblique angles of the magnetic field (~80°) and the ion speed at the electrostatic sheath edge was found to decrease with angle. The edge of the magnetic presheath has been experimentally determined based on the appearance of the E X B drift and is found to be independent of the angle of the magnetic field. We also demonstrate that laser induced fluorescence is suitable as a non-perturbative diagnostic to measure the electric field in a magnetized sheath.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗