Irradiation effect on deuterium behaviour in low-dose HFIR neutron-irradiated tungsten

Tungsten samples were irradiated by neutrons in the High Flux Isotope Reactor, Oak Ridge National Laboratory at reactor coolant temperatures of 50-70°C to low displacement damage of 0.025 and 0.3 dpa under the framework of the US-Japan TITAN program (2007-2013). After cooling down, the HFIR neutron-irradiated tungsten samples were exposed to deuterium plasmas in the Tritium Plasma Experiment, Idaho National Laboratory at 100, 200 and 500 °C twice at the ion fluence of 5×10²⁵ m⁻² to reach a total ion fluence of 1×10²⁶ m⁻² in order to investigate the near surface deuterium retention and saturation via nuclear reaction analysis. Final thermal desorption spectroscopy was performed to elucidate irradiation effect on total deuterium retention. Nuclear reaction analysis results showed that the maximum near surface (<5 µm depth) deuterium concentration increased from 0.5 at % D/W in 0.025 dpa samples to 0.8 at. % D/W in 0.3 dpa samples. The large discrepancy between the total retention via thermal desorption spectroscopy and the near surface retention via nuclear reaction analysis indicated the deuterium was migrated and trapped in bulk (at least 50 µm depth for 0.025 dpa and 35 µm depth for 0.025 dpa) at 500 °C case even in the relatively low ion fluence of 10²⁶ m⁻².

36 MATERIALS SCIENCE↗

Measuring Degradation Rates Without Irradiance Data

A method to report PV system degradation rates without using irradiance data is demonstrated. First, a set of relative degradation rates are determined by comparing daily AC final yields from a group of PV systems relative to the average final yield of all the PV systems. Then, the difference between relative and absolute degradation rates is found from a statistical analysis. This approach is verified by comparing to methods that utilize irradiance data. This approach is significant because PV systems are often deployed without irradiance sensors, so the analysis method described here may enable measurements of degradation using data that were previously thought to be unsuitable for degradation studies.

14 SOLAR ENERGY↗

A Detailed Model of Rear-Side Irradiance for Bifacial PV Modules

We describe and validate a method for modeling irradiance on the back surface of bifacial PV modules at the scale of individual cells using view factors. We compare model results with irradiance measurements on the back of PV modules in various configurations. Our analysis illustrates the relative accuracy of the model as well as the potential variation in back surface irradiance among the cells.

14 SOLAR ENERGY↗

Performance and breakdown characteristics of irradiated vertical power GaN P-i-N diodes

Electrical performance and defect characterization of vertical GaN P-i-N diodes before and after irradiation with 2.5 MeV protons and neutrons is investigated. Devices exhibit increase in specific on-resistance following irradiation with protons and neutrons, indicating displacement damage introduces defects into the p-GaN and n- drift regions of the device that impact on-state device performance. The breakdown voltage of these devices, initially above 1700 V, is observed to decrease only slightly for particle fluence <; 10 13 cm -2 . Furthermore, the unipolar figure of merit for power devices indicates that while the on-resistance and breakdown voltage degrade with irradiation, vertical GaN P-i-Ns remain superior to the performance of the best available, unirradiated silicon devices and on-par with unirradiated modern SiC-based power devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Amorphization of rare earth aluminate garnets by ionic irradiation and decay of 244Cm admixture

The stability of synthetic REE-aluminate garnets irradiated by accelerated Kr 2+ ions and affected by alpha decay of ²⁴⁴Cm (T 1/2 = 18.1 yr) has been studied. The dose of irradiation sufficient for the complete disordering of the aluminate garnet structure is 0.40–0.55 displacements per atom. This value increases with rising temperature due to the increasing intensity of recovery from radiation damage to the lattice by heating. The critical temperature above which the structure of REE-aluminate is not damaged by radiation is 550°C. The amorphization dose for aluminates with garnet structure is two to three times higher than of that previously studied ferrites; the critical temperature of both is similar. In resistance to radiation, aluminate garnets do not yield to zirconolite and exceed titanate pyrochlore. Heating to 250°C does not lead to substantial recovery from radiation defects in the garnet structure. The radiation impact on matrices of real actinide (An) wastes is lower than that related to ion irradiation and ²⁴⁴Cm doping, and this facilitates a higher radiation resistance of garnets containing HLW.

36 MATERIALS SCIENCE↗

AGR-1 Irradiated Compact 6-1-1 PIE Report: Evaluation of As-Irradiated Fuel Performance Using Leach Burn Leach, IMGA, Materialography, and X-ray Tomography

The AGR-1 irradiation test train consisted of six independently monitored capsules. All capsules contained twelve compacts in three stacks of four compacts each [Pope 2010]. Compact 6-1-1 was located in capsule 6, at the top of the test train. The compact was in stack 1 (one of the two stacks closest to the core) in position 1 (at the bottom of the 4 compact stack). Compact 6-1-1 was identified in the fabrication data package as LEU01-46T-Z32 [Hunn et al. 2006]. Details of the compact fabrication and measured properties can be found in that data package. The compact lot was made using TRISO-coated particles designated as AGR-1 Baseline fuel. These particles contained 19.7% enriched mixed uranium oxideuranium carbide (UCO) kernels with a O/U atomic ratio of ~1.36 and a C/U atomic ratio of ~0.33 [Pope 2010]. Details of the coated particle fabrication and measured properties can be found in the data package for the AGR-1 Baseline particles [Hunn and Lowden 2006]. The compact was irradiated at the INL Advanced Test Reactor (ATR) to an average calculated burn-up of 15.1% fissions per initial metal atom (FIMA) and an average calculated fast fluence of 3.0 x 10 25 n/m 2 [Sterbentz 2011] at a calculated volume averaged and time averaged temperature of approximately 1111°C [Hawkes 2012]. Capsules were disassembled and preliminary compact and graphite holder inspection was performed [Demkowicz et al. 2011]. Compact 6-1-1 was shipped to ORNL and post-irradiation examination (PIE) was performed according to examination plan PLN-3624 [Demkowicz 2010-2]. All the examination plan objectives listed below were completed except item 6, which was deleted due to limited funding. 1. Determine the inventory of fission products retained in the compact matrix, but not contained by the SiC and determine the number of exposed kernels or particles with defective SiC layers using the deconsolidation-leach-burn-leach method. 2. Gamma count all particles to quantify 137Cs inventory for comparison with calculated values and gamma spectrometric measurements made on the whole compact. Also, attempt to quantify the inventory of any other fission products for which gamma emissions are observed. 3. Characterize each particle based on the 137 Cs/ 144 Ce ratio to identify particles with low Cs retention that may be the result of a failed SiC coating. 4. Gamma count a subset of particles to determine the 110m Ag inventory for comparison with calculated values and gamma spectrometric measurements made on the whole compact. Also, attempt to quantify the inventory of other fission products observed. 5. Microscopically inspect selected particles to determine the condition of the kernels and coatings. This could include kernel migration, coating microstructures and defects, fission product attack of the SiC layer, and fission product migration in the coating layers. 6. Perform high temperature fission product release tests on a subset of particles in order to calibrate the collection efficiency of the Core Conduction Cooldown Test Facility (CCCTF) deposition cup for selected fission products. Gamma count particles before and after the heating test to quantify the released fission product fractions. 7. Archive remaining particles for later use. Compact 6-1-1 LBL began with compact deconsolidation in the Building 3525 hot cell, followed by two nitric acid leaches of the particles and matrix residue using a Soxhlet extraction apparatus. The matrix residue was then burned and the ash was leached twice with boiling nitric acid. The deconsolidated particles underwent an IMGA analysis to determine gamma-emitting isotope inventories for individual particles; the most conspicuous elements with reduced inventories, indicating fission product release, were silver and europium. During the IMGA analysis, particles with low silver were identified and a subset of these was set aside for materialography and x-ray. After the completion of the IMGA study, about 10% of the particles (421) were set aside as an archive and the remainder burned back and leached twice in the Soxhlet apparatus. Figure 1 shows a flow chart detailing the PIE of Compact 6-1-1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AMMT FY23 HFIR Irradiation Test Matrix – Supported by the Design of a Miniature Bend Bar Irradiation Vehicle

With the continued advancement of additive manufacturing (AM) techniques, interest has grown in the development and qualification of steels produced via these methods for use in the structural components of advanced nuclear reactors. Therefore, it is crucial that the properties of these materials such as the tensile strength and fracture toughness be investigated following neutron irradiation to support their use in industry. To that end, a test plan to irradiate several tensile and bend bar specimens in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory was proposed, along with the development of a new “MINBEN” capsule design that features MBS-1 bend bar specimens that have a larger cross-sectional area than those of previous designs, which allows for higher temperature out-of-pile testing. The specimens include AM 316H stainless steel with wrought 316H and A709 stainless steels for reference, and they will be irradiated at 2 dpa and 10 dpa—corresponding to roughly 1 and 5 cycles at the HFIR midplane—at temperatures of 400°C and 600°C. The MINBEN design was found to be capable of providing specimen test plane average temperatures in the range of 220–660°C for six specimens, with a min-max spread in this temperature of ~40°C and a 95% confidence interval of ~24°C. This analysis shows that the capsule provides an effective vehicle for gathering needed high-temperature fracture toughness data.

36 MATERIALS SCIENCE↗

Status memorandum on ORNL support of vendor irradiation capsule design and ASME irradiation code development and new ASTM test standard development activities

This report is in submission of completion of the Level 4 milestone number M4TG-24OR0501111 within the larger Advanced Reactor Technologies Gas Cooled Reactor program at Oak Ridge National Laboratory (ORNL). The focus of this year’s efforts is to continue support of industry needs related to the development of future industry-funded irradiation programs. At ORNL these efforts included the development of a generalized three-dimensional CAD model of an irradiation creep capsules for graphite, cost estimates of the expansion of the Materials Irradiation Facility (MIF), involvement with ASTM D02.F0 “Manufactured Carbon and Graphite Products” and the ASME Boiler and Pressure Vessel Code, and publication of papers supporting these efforts. This report will document the status of these activities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving Thermal Model Prediction Through Statistical Analysis of Irradiation and Post-Irradiation Data from AGR Experiments

As part of the Research and Development program for Next Generation High Temperature Reactors (HTR), a series of irradiation tests, designated as Advanced Gas-cooled Reactor (AGR), have been defined to support development and qualification of fuel design, fabrication process, and fuel performance under normal operation and accident conditions. The AGR tests employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule and instrumented with thermocouples (TC) embedded in graphite blocks enabling temperature control. The data representing the crucial test fuel conditions (e.g., temperature, neutron fast fluence, and burnup) while impossible to obtain from direct measurements are calculated by physics and thermal models. The irradiation and post-irradiation examination (PIE) experimental data are used in model calibration effort to reduce the inherent uncertainty of simulation results. This paper is focused on fuel temperature predicted by the ABAQUS code’s finite element-based thermal models. The work follows up on a previous study, in which several statistical analysis methods were adapted, implemented in the NGNP Data Management and Analysis System (NDMAS), and applied for improving qualification of AGR-1 thermocouple data. The present work exercises the idea that the abnormal trends of measured data observed from statistical analysis may be caused by either measuring instrument deterioration or physical mechanisms in capsules that may have shifted the system thermal response. As an example, the uneven reduction of the control gas gap in Capsule 5 revealed by the capsule metrology measurements in PIE helps justify the reduction in TC readings instead of TC drift. This in turn prompts modification of thermal model to better fit with experimental data, thus help increase confidence, and in other word reduce model uncertainties in thermal simulation results of the AGR-1 test.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Post-irradiation Examination and Fission Product Inventory Analysis of AGR-1 Irradiation Capsules

The AGR-1 experiment was the first in a series of Advanced Gas Reactor (AGR) experiments designed to test TRISO fuel under High Temperature Gas Reactor irradiation conditions. This experiment was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and is currently undergoing post-irradiation examination (PIE) at INL’s Materials and Fuels Complex (MFC). The inventory and distribution of fission products, especially Ag-110m, was assessed and analyzed for all the components of the AGR-1 capsules. This data should help inform the study of fission product migration in coated particle fuel. Gamma spectrometry was used to measure the activity of various different fission products in the different components of the AGR-1 test train. Each capsule contained: 12 fuel compacts, a graphite holder that kept the fuel compacts in place, graphite spacers that were above and below the graphite holders and fuel compacts, gas lines through which a helium neon gas mixture flowed in and out of each capsule, and the stainless steel shell that contained the experiment. Gamma spectrometry results and the experimental techniques used to capture these results will be presented for all the capsule components. The components were assayed to determine the total activity of different fission products present in or on them. These totals are compared to the total expected activity of a particular fission product in the capsule based on predictions from physics simulation. Based on this metric, a significant fraction of the Ag-110m was detected outside the fuel compacts, but the amount varied highly between the 6 capsules. Very small fractions of Cs-137 (<2E-5), Cs-134 (<1e-5), and Eu-154 (<4e-4) were detected outside of the fuel compacts. Additionally, the distribution of select fission products in some of the components including the fuel compacts and the graphite holders were measured and will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical TEM characterization of modified F82H and 14YW under irradiation of simultaneous helium and neutron irradiation compared to only neutron at 500 C

A RAFM steel and an ODS ferritic alloy (F82H.mod3+CW and 14YW, respectively) were irradiated as part of the JP27 irradiation experiment conducted in the High Flux Isotope Reactor to explore He effects in structural alloys. The ISHI technique is used to implant He up to 9 µm below the surface of a NiAl coated sample at He/dpa levels up to ~50. This report summarizes the current status of TEM characterization of two irradiated alloys. The He-implanted side of the RAFM alloy exhibited significant swelling due to bubble and void formation within the matrix, on pre-existing dislocations, and at interfaces within the material. The 14YW alloy exhibited significant swelling even in the absence of implanted He, primarily through large voids that formed on the ODS particles. In addition, significant radiation-induced segregation of the Cr was observed around oxide particles and on lath boundaries, and visible α' particles could be detected via elemental mapping of the matrix of the 14YW alloy.

36 MATERIALS SCIENCE↗

Preliminary results from the first round of post-irradiation heating tests of fuel compacts from the US AGR-3/4 irradiation

Three post-irradiation heating tests of fuel compacts from the US AGR-3/4 irradiation experiment. In addition to TRISO-coated driver fuel, each compact contained 20 particles with UCO fuel kernels coated only in pyrocarbon to simulate exposed kernels. Tests at 1600/1700°C, 1400°C, and 1200°C were performed to measure fission product releases as a function of time and temperature. Silver releases were highest in the 1200°C test, supporting the observation that silver release rates are highest in the temperature range of 1100-1300°C. Except for Ag-110m (which was released in multiple particle equivalents) releases of Cs, Kr, Eu, and Sr were all less than one particle inventory per compact. This suggests that exposed kernels retain little Cs and Kr after irradiation. Despite these low releases, compared to tests of compacts with no exposed kernels, the Cs and Kr releases were noticeably higher, and at 1600°C the exposed kernels contributed noticeably more Eu and Sr than in AGR-1 compacts with no exposed kernels. These data can be used to make inferences on retention of fission products in exposed kernels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microstructure of RERTR Du-Alloys Irradiated with Krypton Ions up to 100 dpa

The radiation stability of the interaction product formed at the fuel–matrix interface of research reactor dispersion fuels, under fission-product bombardment, has a strong impact on fuel performance. Three depleted uranium alloys were cast that consisted of the following five phases to be investigated: U(Si, Al)3, (U, Mo)(Si, Al)3, UMo2Al20, U6Mo4Al43, and UAl4. Irradiation of transmission electron microscopy (TEM) disc samples with 500-keV Kr ions at 200 °C to doses up to 100 displacements per atom (dpa) were conducted using a 300-keV electron microscope equipped with an ion accelerator. TEM results show that the U(Si, Al)3 and UAl4 phases remain crystalline at 100 dpa without forming voids. The (U, Mo)(Si, Al)3 and UMo2Al20 phases become amorphous at 1 and 2 dpa, respectively, and show no evidence of voids at 100 dpa. The U6Mo4Al43 phase goes to amorphous at less than 1 dpa and reveals high density voids at 100 dpa.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Atomistic study of grain boundary sink strength under prolonged electron irradiation

Grain boundaries (GBs) are sinks and sources of point defects, which are produced in large number under radiation damage. As grain size decreases, many of the point defects sink into GBs. It is unknown whether GBs will saturate as sinks of point defects, particularly when grain size is at the nanoscale. Using a combination of molecular dynamics (MD) simulations and rate theory for BCC Mo, the authors show that large-angle GBs do not saturate as sinks of point defects. The MD simulations serve to provide direct measurement of defect evolution, and the rate theory serves to test whether grain boundary sink strength is a constant and to extend the MD results to realistic defect production rates.

36 MATERIALS SCIENCE↗

A New Fully Covered Irradiation Stent Versus a Partially Covered Irradiation Stent for Unresectable Malignant Dysphagia: A Single-Center Experience

Purpose: To assess the efficacy and safety of a newly developed fully covered irradiation stent (FCIS) compared with a partially covered irradiation stent (PCIS) in patients with unresectable malignant dysphagia. Materials and Methods: Data of 195 patients [158 (81.0%) males, median age of 75 years (range 49–89 years)] who underwent FCIS or PCIS placement for unresectable malignant dysphagia from January 2012 to November 2017 were retrospectively analyzed. The median follow-up time was 181 days (range 4–547 days). Outcomes were measured in terms of recurrent dysphagia (primary), technical success, clinical success, overall survival, and adverse events. Recurrent dysphagia was analyzed by Fine–Gray regression model. Results: The technical success rate was 97.8% (87/89) in the FCIS group and 99.1% (105/106) in the PCIS group (P = 0.59). The clinical success rate was 100.0% in both groups. There was no statistically significant difference in the recurrent dysphagia rate between the FCIS and PCIS groups (21.8% vs. 28.6%; P = 0.12). Compared with PCISs, FCISs were associated with a decrease in tissue/tumor growth rate (11.5% vs. 21.9%; P = 0.01), while stent migration rates were statistically comparable (11.5% vs. 5.7%; P = 0.23). The median overall survivals were comparable between the FCIS and PCIS groups (164 days vs. 162 days; P = 0.70). A dysphagia score of 4 and metastasis were risk factors for survival. No significant differences were observed in the rates of adverse events, including chest pain, fistula formation, hemorrhage, and aspiration pneumonia (P > 0.05). Conclusion: For patients with unresectable malignant dysphagia, this newly developed FCIS can provide efficacy and safety comparable to those of a PCIS. Compared with PCIS, this FCIS is more successful in preventing tissue/tumor growth, with a comparable stent migration rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Damage evolution of ion irradiated defected-fluorite La 2 Zr 2 O 7 epitaxial thin films

Pyrochlore-structure oxides, A2B2O7, may exhibit remarkable radiation tolerance due to the ease with which they can accommodate disorder by transitioning to a defected fluorite structure. The mechanism of defect formation was explored by evaluating the radiation damage behavior of high quality epitaxial La2Zr2O7 thin films with the defected fluorite structure, irradiated with 1 MeV Zr+ at doses up to 10 displacements per atom (dpa). The level of film damage was evaluated as a function of dose by Rutherford backscattering spectrometry in the channeling geometry (RBS/c) and scanning transmission electron microscopy (STEM). At lower doses, the surface of the La2Zr2O7 film amorphized, and the amorphous fraction as a function of dose fit well to a stimulated amorphization model. As the dose increased, the surface amorphization slowed, and amorphization appeared at the interface. Even at a dose of 10 dpa, the core of the film remained crystalline, despite the prediction of amorphization from the model. To inform future ab initio simulations of La2Zr2O7, the bandgap of a thick La2Zr2O7 film was measured to be indirect at 4.96 eV, with a direct transition at 5.60 eV.

Environmental Molecular Sciences Laboratory↗