NanoStructured bulk thermoelectric generator for efficient power harvesting for self-powered sensor network

The goal of the Nuclear Energy Enabling Technology Research Project is to develop efficient and reliable thermoelectric (TE) generators for self-powered wireless sensor nodes (WSNs) for nuclear applications. The power harvesting technology has crosscutting significance to all United States Department of Energy Office of Nuclear Energy research and development programs, as it will enable self-powered WSNs in multiple nuclear reactor designs and spent fuel storage facilities using thermal energy available in a nuclear power plant or spent fuel storage facility. This project addresses an important technology gap that exists in truly realizing WSNs due to the need for cables to connect to external power supplies and develop TE power harvesting devices to deliver sufficient power to drive the WSNs. The outcomes of the project will lead to significant advancement in sensors and instrumentation technology, reducing cost, improving monitoring reliability, and therefore enhancing safety. The self-powered WSNs could support the long-term safe and economical operation of all reactor designs and fuel cycle concepts, as well as spent fuel storage and many other nuclear science and engineering applications. The research is based on recent breakthroughs in high-performance nanostructured bulk (nanobulk) half-Heusler and bismuth telluride thermoelectric materials that enable high-efficiency and high-power-density direct heat-to-electricity conversion over a wide temperature range. The nanobulk TE materials that the research team has already developed yield up to a 50% increase in the TE figure of merit, ZT, compared with state-of-the-art bulk counterparts. In addition to increased efficiency, the nanostructured materials are of potentially enhanced radiation tolerance due to the increased interface densities at the nanoscale grain boundaries that serves as efficient sinks to annihilate radiation-induced, freely-migrating structural defects. This report summarizes major technical results the team achieved in this three-year project, with a focus on the results obtained in the third year of the project. The report includes results on thermoelectric materials fabrication and optimization, irradiation effect on thermoelectric materials performance, thermoelectric device simulation, fabrication and testing, wireless sensor node system simulation, and the demonstration of a wireless sensor node powered by thermoelectric generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-49: Dosimetry Parameters and TPS Commissioning for the CivaSheet Directional Pd-103 Brachytherapy Source

Purpose: The CivaSheet is a new LDR Pd-103 brachytherapy device offering directional-radiation for preferentially irradiating malignancies with healthy-tissue sparing. Observations are presented on dosimetric characterization, TPS commissioning, and evaluation of the dosesuperposition- principle for summing individual elements comprising a planar CivaSheet Methods: The CivaSheet comprises individual sources (CivaDots, 0.05cm thick and 0.25cm diam.) inside a flexible bioabsorbable substrate with a 0.8cm center-to-center rectangular array. All non-radioactive components were measured to ensure accuracy of manufacturer-provided dimensional information. The Pd spatial distribution was gleaned from radioactive and inert samples, then modeled with the MCNP6 radiation-transport-code. A 6×6 array CivaSheet was modeled to evaluate the dose superposition principle for treatment planning. Air-kerma-strength was estimated using the NIST WAFAC geometry. Absorbed dose was estimated in water with polar sampling covering 0.05≤r≤15cm in 0.05cm increments and 0°≤θ≤180° in 1° increments. These data were entered into VariSeed9.0 and tested for the dose-superposition-principle. Results: The dose-rate-constant was 0.579 cGy/h/U with g(r) determined along the rotational-axis of symmetry (0°) instead of 90°. gP(r) values at 0.1, 0.5, 2, 5, and 10cm were 1.884, 1.344, 0.558, 0.088, and 0.0046. F(r,θ) decreased between 0° and 180° by factors of 270, 23, and 5.1 at 0.1, 1, and 10cm. The highest dose-gradient was at 92°, changing by a factor of 3 within 1° due to Au-foil shielding. TPS commissioning from 0.1≤r≤11cm and 0°≤θ≤180° demonstrated 2% reproducibility of input data except at the high-dose-gradient where interpolations caused 3% differences. Dose superposition of CivaDots replicated a multi-source CivaSheet array within 2% except where another CivaDot was present. Following implantation, the device is not perfectly planar. TPS accuracy utilizing the dose-superposition-principle through geometric repositioning of CivaDots supersedes TPS limitations of intersource shielding effects Conclusion: Dosimetric characterization, source commissioning, and evaluation of the dose-superposition-principle with VariSeed9.0 permits treatment planning for the CivaSheet brachytherapy device. Research supported in part by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

Neutron radiation tolerance of Au-activated silicon

Double injection devices prepared by the introduction of deep traps, using the Au activation method have been found to tolerate gamma irradiation into the Gigarad (Si) region without significant degradation of operating characteristics. Silicon double injection devices, using deep levels creacted by Au diffusion, can tolerate fast neutron irradiation up to 10 to the 15th n/sq cm. Significant parameter degradation occurs at 10 to the 16th n/sq cm. However, since the actual doping of the basic material begins to change as a result of the transmutation of silicon into phosphorus for neutron fluences greater than 10 to the 17th/sq cm, the radiation tolerance of these devices is approaching the limit possible for any device based on initially doped silicon.

Joyner, W. T.↗

Electronic system for data acquisition to study radiation effects on operating MOSFET transistors

In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray.

36 MATERIALS SCIENCE↗

Characterizations of Aged Glass/Ethylene Vinyl Acetate/Glass Using Fluorescence Spectroscopy and Instrumented Indentation

Ethylene vinyl acetate (EVA) is widely used as an encapsulant in photovoltaic devices, which are exposed to simultaneous UV irradiation, thermal, and humidity conditions. Aging behaviors of the EVA were characterized using confocal fluorescence spectroscopy with submicron scale resolutions of cross-sections of aged EVA samples. Additionally, mechanical properties of fluorescing regions in the aged EVAs where fluorescence emission was measured were investigated using a nanoindentation technique. In this study, we characterized two different formulations of EVA in glass/EVA/glass specimens after UV irradiation at 40 degrees C, 60 degrees C and 80 degrees C with 50 % relative humidity for 180 days. The fluorescence intensities on the UV irradiated sides of EVA samples were higher than those for the unexposed sides over wavelengths from 400 nm to 800 nm, and intensity differences between the two sides became more pronounced when the specimens were aged at higher temperatures. Elastic moduli of UV irradiated side for samples measured by instrumented indentation decreased, compared to unaged EVA samples, while fluorescent intensity increased with increasing the aging temperature.

14 SOLAR ENERGY↗

SU-E-T-145: Beam Characteristics of Flattening Filter Free Beams Including Low Dose Rate Setting

Purpose: In commissioning of volumetric modulated arc therapy (VMAT), it is necessary to evaluate the beam characteristics of various dose rate settings with potential to use. The aim of this study is to evaluate the beam characteristics of flattened and flattening filter free (FFF) including low dose rate setting. Methods: We used a Varian TrueBeam with Millennium 120 MLC. Both 6 and 10 MV beams with or without flattening filter were used for this study. To evaluate low-dose rate FFF beams, specially-designed leaf sequence files control out-of-field MLC leaf pair at constant dose rate ranging from 80 to 400 MU/min. For dose rate from 80 MU/min to the maximum usable value of all energies, beam output were measured using ionization chamber (CC04, IBA). The ionization chamber was inserted into water equivalent phantom (RT3000-New, R-tech), and the phantom was set with SAD of 100cm. The beam profiles were performed using the 2D diode array (Profiler2, Sun Nuclear). The SSD was set to 90cm and a combined 30cmx30cmx9cm phantom which consisted of solid water slabs was put on the device. All measurement were made using 100MU irradiation for 10cmx10cm jaw-defined field size with a gantry angle of 0°. Results: In all energies, the dose rate dependences with beam output and variation coefficient were within 0.2% and 0.07%, respectively. The flatness and symmetry exhibited small variations (flatness ≤0.1 point and symmetry≤0.3 point at absolute difference). Conclusion: We had studied the characteristics of flattened and FFF beam over the 80 MU/min. Our results indicated that the beam output and profiles of FFF of TrueBeam linac were highly stable at low dose rate setting.

60 APPLIED LIFE SCIENCES↗

SU-F-T-22: Clinical Implications When Using TG-186 (ACE) Heterogeneity Software

Purpose: The purpose of this study is to compare dosimetric calculations using traditional TG-43 formalism and Oncentra Brachy Advanced Collapsed cone Engine (ACE) TG-186 calculation algorithm in clinical setting. Methods: We analyzed dosimetry of four patients treated with accelerated partial breast irradiation using a multi-channel intracavitary device (SAVI). All patients were treated to 34 Gy in 10 fractions using a high-dose-rate (192) Ir source. The plans were designed and treated using the TG-43 model. ACE was used to assess the effect heterogeneity correction on various dosimetric parameters. Mass density was estimated using Hounsfield units. Results: Compared to TG-43 formalism, ACE estimated lower doses to targets and organs at risk. The mean difference was 19.8% (range 15.3–24.1%) for PTV-eval V200, 12.0% (range 9.7–17.7%) for PTV-eval V150, 4.3% (range 3.3–6.5%) for PTV-eval D95, 3.3% (range 1.4–5.4%) for PTV-eval D90, 5.4% (range 2.9–9.9%) for maximum rib dose, and 5.7% (2.4–7.4%) for maximum skin dose. There was no correlation between the magnitude of the difference and the PTV-eval volume, air volume, or tissue-applicator conformance. Conclusion: Based on our preliminary study, the TG-43 algorithm appears to overestimate the dose to targets and organs at risk when compared to the ACE TG-186 software. We hypothesize that air adjacent to the SAVI struts contributes to lack of scatter thereby contributing a significant difference in dose calculation when using ACE. We believe that ACE calculation provides a more realistic isodose distribution than TG-43. We plan to further investigate the impact of heterogeneity correction on brachytherapy planning for a wide variety of clinical scenarios, include skin, cervix/uterus, prostate, and lung.

60 APPLIED LIFE SCIENCES↗

New radiometric techniques and solar constant measurements.

A series of absolute cavity radiometers, designed to measure solar irradiance, has been developed at the Jet Propulsion Laboratory. Analysis indicates the absolute uncertainty of irradiance measurements made by the most recent devices to be less than plus or minus 0.5 mW/sq cm. In a series of experiments the radiometric scale defined by the JPL instruments has been compared with the International Pyrheliometric Scale (IPS). A systematic 2.2% difference has been observed with the IPS producing consistently lower measurements. The solar constant and spectral distribution have been derived from high-altitude balloon flight measurements made by two types of JPL cavity radiometers. Measurements at 25 km in 1968 produced a solar constant value of 137.0 mW/sq cm. From 1969 measurements at 36 km, a value of 136.6 mW/sq cm was derived, with an estimated absolute uncertainty of plus or minus 0.5%. The solar spectrum information from these experiments agrees most closely with the solar spectrum model of Labs and Neckel (1968).

Willson, R. C.↗

YBa2Cu3O(7-x)/Au/Nb device structures

Fabrication and testing of planar and edge geometry YBaCuO/Au/Nb superconductor/normal-metal/superconductor (SNS) device structures is described. Weak-link devices of this type serve as sensitive probes of the electrical quality of the YBaCuO/Au interface. The devices are fabricated using laser-ablated, in situ, c-axis-oriented YBaCuO thin films, with both annealed and unannealed YBaCuO/Au interfaces. The planar SNS structures are formed by sequential, in situ deposition of YBaCuO, Au, and Nb, followed by etching, planarization, and wiring electrode definition to produce junctions ranging from 5 to 20 micron on a side. Resulting RnA products are 1-10 x 10 to the -8th ohm-sq cm with critical current densities up to 5 kA/sq cm. For the edge geometry devices, the YBaCuO film edges are patterned using Ar ion milling, followed by a low energy ion cleaning step and in situ deposition of Au and Nb. Devices with areas in the 10 to the -7th to 10 to the -8th sq cm range have been fabricated with RnA products lower than 10 to the -8th ohm-sq cm and critical current densities up to 3kA/sq cm. Both types of devices show ac Josephson steps under microwave irradiation. The best results have been obtained with annealed YBaCuO/Au interfaces.

Hunt, B. D.↗

Recent Progress on Radiation Damage Studies at RaDIATE

Recent major accelerator facilities have been limited in beam power by production target and beam window survivability, where radiation damage to their constituent materials has been identified as the most cross-cutting challenge facing these high power target facilities. The RaDIATE collaboration, Radiation Damage In Accelerator Target Environments, was formed in 2012 to address this challenge by bringing together experts from the fields of nuclear materials and accelerator target facilities. The collaboration conducted high intensity proton beam irradiation of test specimens at the Brookhaven Linac Isotope Producer (BLIP) facility at BNL, where the specimens, including candidate materials for various beam intercepting device applications, were provided by participating accelerator facilities. Post-Irradiation Examination (PIE) of the irradiated specimens is being conducted at participating nuclear/fusion research institutions with appropriate ``hot-cell'' facilities, such as Pacific Northwest National Laboratory (PNNL).The recent collaboration work also includes efforts to provide the samples irradiated at BLIP to in-beam thermal shock test at CERN's HiRadMat facility. It will be the first examination to observe how the radiation-damaged material will behave when exposed to actual beam loading conditions. In this talk up-to-date status of these experiments, PIEs, and prospect for the works conducted by the RaDIATE collaboration are over-viewed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-439: Fundamental Verification of Respiratory-Gated Spot Scanning Proton Beam Therapy

Purpose: The spot-scanning proton beam irradiation with respiratory gating technique provides quite well dose distribution and requires both dosimetric and geometric verification prior to clinical implementation. The purpose of this study is to evaluate the impact of gating irradiation as a fundamental verification. Methods: We evaluated field width, flatness, symmetry, and penumbra in the gated and non-gated proton beams. The respiration motion was distinguished into 3 patterns: 10, 20, and 30 mm. We compared these contents between the gated and non-gated beams. A 200 MeV proton beam from PROBEAT-III unit (Hitachi Co.Ltd) was used in this study. Respiratory gating irradiation was performed by Quasar phantom (MODUS medical devices) with a combination of dedicated respiratory gating system (ANZAI Medical Corporation). For radiochromic film dosimetry, the calibration curve was created with Gafchromic EBT3 film (Ashland) on FilmQA Pro 2014 (Ashland) as film analysis software. Results: The film was calibrated at the middle of spread out Bragg peak in passive proton beam. The field width, flatness and penumbra in non-gated proton irradiation with respiratory motion were larger than those of reference beam without respiratory motion: the maximum errors of the field width, flatness and penumbra in respiratory motion of 30 mm were 1.75% and 40.3% and 39.7%, respectively. The errors of flatness and penumbra in gating beam (motion: 30 mm, gating rate: 25%) were 0.0% and 2.91%, respectively. The results of symmetry in all proton beams with gating technique were within 0.6%. Conclusion: The field width, flatness, symmetry and penumbra were improved with the gating technique in proton beam. The spot scanning proton beam with gating technique is feasible for the motioned target.

60 APPLIED LIFE SCIENCES↗

Characterization of the degradation of gamma-irradiated elastomers using Raman spectroscopy

This report presents key findings from Raman spectroscopic analysis of gamma-irradiated rubber samples extracted from a laminated lead-damped rubber (LDR) seismic isolation device. The samples were exposed to gamma radiation from a 60Co source in a Foss Therapy Services gamma irradiator, reaching absorbed doses up to 1600 kGy. A distinct threshold near 400 kGy was identified, beyond which significant spectral changes were observed. Two Raman peaks - at approximately 425 cm-1 and 2440 cm-1 - were tracked as a function of dose using Gaussian fitting. The 425 cm-1 peak, attributed to sulfur–sulfur (S–S) bond stretching (resulting from vulcanization of the rubber), exhibited a dose-dependent upshift, indicating radiation-induced crosslinking within the sulfur-based polymer network. Conversely, the 2440 cm-1 peak, likely associated with vibrational modes of additives or impurities, showed a downward shift with increasing dose, suggesting chain scission and degradation of non-rubber constituents. These results provide first-of-a-kind insights into the microstructural evolution of elastomers under high-dose gamma irradiation and establish a preliminary dose threshold for significant degradation. Future work will incorporate multi-modal characterization—including Fourier Transform Infrared (FTIR) spectroscopy, scanning electrom microscopy (SEM) of the rubber surface morphology, thermogravimetric analysis (TGA) to determine changes in thermal stability, and mechanical testing—to correlate molecular-level changes with macroscopic performance of these elastomers as damping media in seismic isolation devices. These findings are expected to provide regulatory guidance and design criteria for qualifying low-damping rubber seismic isolators in advanced nuclear reactor applications.

36 - MATERIALS SCIENCE↗

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman↗

Fabrication and Testing of Habitat Components Using In-Situ Materials for Martian Exploration

The development of Mars for human activity will require the utilization of Martian materials in building habitats and working structures. One approach is to use polymer binders with regolith to form structural elements. Not only can useful composite materials be produced in this way but the radiation protection properties are also increased. This is important since only modest protection from space radiation is provided by the Martian atmosphere. We have studied composites fabricated using Martian regolith simulant and polymers which can be synthesized from local Martian materials for their potential use as radiation shields for manned Mars missions. To validate shielding effectiveness, composites are irradiated with a 55 MeV proton beam and neutron beams up to 800 MeV. Shielding effects on microelectronic devices are measured by placing them behind samples of the composites during irradiation. To measure structural properties of the composites, preliminary characterization and mechanical testing are made for the composites.

Kim, M.-H. Y.↗

Double-injection, deep-impurity switch development

The overall objective of this program is the development of device design and process techniques for the fabrication of a double-injection, deep-impurity (DI)(2) silicon switch that operates in the 1-10 kV range with conduction current of 10 and 1A, respectively. Other major specifications include a holding voltage of 0 to 5 volts at 1 A anode current, 10 microsecond switching time, and power dissipation of 50 W at 75 C. This report describes work that shows how the results obtained at the University of Cincinnati under NASA Grant NSG-3022 have been applied to larger area and higher voltage devices. The investigations include theoretical, analytical, and experimental studies of device design and processing. Methods to introduce deep levels, such as Au diffusion and electron irradiation, have been carried out to "pin down' the Fermi level and control device-switching characteristics. Different anode, cathode, and gate configurations are presented. Techniques to control the surface electric field of planar structures used for (DI)(2) switches are examined. Various sections of this report describe the device design, wafer-processing techniques, and various measurements which include ac and dc characteristics, 4-point probe, and spreading resistance.

Selim, F. A.↗

Blood Irradiator Interactive Tool Beta Version

The “Blood Irradiator Interactive Tool” compares a typical Cs-137 Blood Irradiator with that of the capabilities of an average X-ray Irradiator. It is designed to inform the user about the potential capabilities that an average X-ray Irradiator could offer them. Specifically the tool compares the amount of blood bags that can be irradiated by the users’ machine with that of the average X-ray capability. It also forcasts the amount of blood that can be irradiated on yearly basis for both the users’ machine and an average X-ray Device. The Average X-ray capabilities are taken from the three X-ray devices currently on the market: The RS 3400 Rad Source X-ray Blood Irradiator and both the 2.0L and 3.5 L versions of the Best Theratronis Raycell MK2

Howington, John↗

A novel thermal acoustic device based on porous graphene

A thermal acoustic (TA) device was fabricated by laser scribing technology. Polyimide (PI) can be converted into patterned porous graphene (PG) by laser’s irradiation in one step. The sound pressure level (SPL) of such TA device is related to laser power. The theoretical model of TA effect was established to analyze the relationship between the SPL and laser power. The theoretical results are in good agreement with experiment results. It was found that PG has a flat frequency response in the range of 5-20 kHz. This novel TA device has the advantages of one-step procedure, high flexibility, no mechanical vibration, low cost and so on. It can open wide applications in speakers, multimedia, medical, earphones, consumer electronics and many other aspects.

36 MATERIALS SCIENCE↗