Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Performance characteristics of a perforated shadow band under clear sky conditions

A perforated, non-rotating shadow band is described for separating global solar irradiance into its diffuse and direct normal components using a single pyranometer. Whereas shadow bands are normally solid so as to occult the sensor of a pyranometer throughout the day, the proposed band has apertures cut from its circumference to intermittently expose the instrument sensor at preset intervals. Under clear sky conditions the device produces a saw tooth waveform of irradiance data from which it is possible to reconstruct separate global and diffuse curves. The direct normal irradiance may then be calculated giving a complete breakdown of the irradiance curves without need of a second instrument or rotating shadow band. This paper describes the principle of operation of the band and gives a mathematical model of its shading mask based on the results of an optical ray tracing study. An algorithm for processing the data from the perforated band system is described and evaluated. In an extended trial conducted at NREL's Solar Radiation Research Laboratory, the band coupled with a thermally corrected Eppley PSP produced independent curves for diffuse, global and direct normal irradiance with low mean bias errors of 5.6 W/m{sup 2}, 0.3 W/m{sup 2} and -2.6 W/m{sup 2} respectively, relative to collocated reference instruments. Random uncertainties were 9.7 W/m{sup 2} (diffuse), 17.3 W/m{sup 2} (global) and 19.0 W/m{sup 2} (direct). When the data processing algorithm was modified to include the ray trace model of sensor exposure, uncertainties increased only marginally, confirming the effectiveness of the model. Deployment of the perforated band system can potentially increase the accuracy of data from ground stations in predominantly sunny areas where instrumentation is limited to a single pyranometer. (author)

14 SOLAR ENERGY↗

MECHANICAL CHARACTERIZATION OF THE ITER MOCK-UP INSULATION AFTER REACTOR IRRADIATION

The ITER mock-up project was launched in order to demonstrate the feasibility of an industrial impregnation process using the new cyanate ester/epoxy blend. The mock-up simulates the TF winding pack cross section by a stainless steel structure with the same dimensions as the TF winding pack at a length of 1 m. It consists of 7 plates simulating the double pancakes, each of them is wrapped with glass fiber/Kapton sandwich tapes. After stacking the 7 plates, additional insulation layers are wrapped to simulate the ground insulation. This paper presents the results of the mechanical quality tests on the mock-up pancake insulation. Tensile and short beam shear specimens were cut from the plates extracted from the mock-up and tested at 77 K using a servo-hydraulic material testing device. All tests were repeated after reactor irradiation to a fast neutron fluence of 1x10{sup 22} m{sup -2}(E>0.1 MeV). In order to simulate the pulsed operation of ITER, tension-tension fatigue measurements were performed in the load controlled mode. Initial results show a high mechanical strength as expected from the high number of thin glass fiber layers, and an excellent homogeneity of the material.

36 MATERIALS SCIENCE↗

Thermal stability of deep level defects induced by high energy proton irradiation in n-type GaN

The impact of annealing of proton irradiation-induced defects in n-type GaN devices has been systematically investigated using deep level transient and optical spectroscopies. Moderate temperature annealing (>200–250 °C) causes significant reduction in the concentration of nearly all irradiation-induced traps. While the decreased concentration of previously identified N and Ga vacancy related levels at E{sub C} − 0.13 eV, 0.16 eV, and 2.50 eV generally followed a first-order reaction model with activation energies matching theoretical values for N{sub I} and V{sub Ga} diffusion, irradiation-induced traps at E{sub C} − 0.72 eV, 1.25 eV, and 3.28 eV all decrease in concentration in a gradual manner, suggesting a more complex reduction mechanism. Slight increases in concentration are observed for the N-vacancy related levels at E{sub C} − 0.20 eV and 0.25 eV, which may be due to the reconfiguration of other N-vacancy related defects. Finally, the observed reduction in concentrations of the states at E{sub C} − 1.25 and E{sub C} − 3.28 eV as a function of annealing temperature closely tracks the detailed recovery behavior of the background carrier concentration as a function of annealing temperature. As a result, it is suggested that these two levels are likely to be responsible for the underlying carrier compensation effect that causes the observation of carrier removal in proton-irradiated n-GaN.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduction of Effective Carrier Density and Charge Collection Efficiency in SiC Devices Due to Radiations

6H-Silicon Carbide (SiC) diodes were fabricated and irradiated with Co-60 gamma-rays, 1 MeV electrons, and 65 MeV protons. After the radiation damage was introduced in devices, the Charge Collection Efficiency (CCE) was evaluated by using the Transient Ion Beam Induced Current (TIBIC) system. The effective carrier density was also estimated from Capacitance-Voltage (C-V) characteristics. It was found that both the CCE and the effective carrier density decrease with increase in the fluence. We discuss whether Non-Ionizing Energy Loss (NIEL) analysis can estimate the degradation in these parameters. Results from this study suggest that the damage factors of these parameters in SiC can be scaled by the NIEL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a Contamination Film Formed by the Electron Beam Irradiation

In the study of materials on electron probe devices in the field of action of the electron beam, a contaminating hydrocarbon film is formed, which affects the experimental results. In this paper, we have studied the influence of a contamination film on carbon-film-coated dielectrics on the intensity of cathodoluminescence and characteristic X-ray lines. The absorption coefficient of the contamination film in the visible and UV ranges has been determined. Filming mechanisms at different parameters of the electron beam have been discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-Cost Multiparameter Device for Solar Resource Applications

The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs Inc., deployed, calibrated, and characterized Arable Lab's Mark low-cost, multiparameter sensor system. Arable Labs was selected by the U.S. Department of Energy for a small business voucher to work with NREL to tap into the knowledge and expertise Arable needs to tailor and evaluate the Mark device for broader solar energy applications. The device is a complete and independent unit. It is a self-powered, off-the-shelf solution for remote solar irradiance and meteorological sensing and data collection. Calibration of devices against the SRRL instruments provides an understanding of the quality of a new instrument compared to peers. The characterization process provides an understanding of the variability compared to high-quality instruments and essentially provides methods to correct the sources of the variabilities.

14 SOLAR ENERGY↗

Probing elemental diffusion and radiation tolerance of perovskite solar cells via non-destructive Rutherford backscattering spectrometry

Mixed organic–inorganic halide perovskite-based solar cells have attracted interest in recent years due to their potential for both terrestrial and space applications. Analysis of interfaces is critical to predicting device behavior and optimizing device architectures. Most advanced tools to study buried interfaces are destructive in nature and can induce further degradation. Ion beam techniques, such as Rutherford backscattering spectrometry (RBS), is a useful non-destructive method to probe an elemental depth profile of multilayered perovskite solar cells (PSCs) as well as to study the inter-diffusion of various elemental species across interfaces. Additionally, PSCs are becoming viable candidates for space photovoltaic applications, and it is critical to investigate their radiation-induced degradation. RBS can be simultaneously utilized to analyze the radiation effects induced by He+ beam on the device, given their presence in space orbits. In the present work, a 2 MeV He+ beam was used to probe the evidence of elemental diffusion across PSC interfaces with architecture glass/ITO/SnO2/Cs0.05(MA0.17FA0.83)0.95Pb(I0.83Br0.17)3/spiro-OMeTAD/MoO3/Au. During the analysis, the device active area was exposed to an irradiation equivalent of up to 1.62 × 1015 He+/cm2, and yet, no measurable evidence (with a depth resolution ∼1 nm) of beam-induced ion migration was observed, implying high radiation tolerance of PSCs. On the other hand, aged PSCs exhibited indications of the movement of diverse elemental species, such as Au, Pb, In, Sn, Br, and I, in the active area of the device, which was quantified with the help of RBS.

14 SOLAR ENERGY↗

Reduction of 1/f noise in graphene after electron-beam irradiation

We investigated experimentally the effect of the electron-beam irradiation on the level of the low-frequency 1/f noise in graphene devices. It was found that 1/f noise in graphene reduces with increasing concentration of defects induced by irradiation. The increased amount of structural disorder in graphene under irradiation was verified with micro-Raman spectroscopy. The bombardment of graphene devices with 20-keV electrons reduced the noise spectral density, S{sub I}/I{sup 2} (I is the source-drain current) by an order-of magnitude at the radiation dose of 10{sup 4} {mu}C/cm{sup 2}. We analyzed the observed noise reduction in the limiting cases of the mobility and carrier number fluctuation mechanisms. The obtained results are important for the proposed graphene applications in analog, mixed-signal, and radio-frequency systems, integrated circuits and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-282: Quality Assurance for IMRT/VMAT QA Devices: Issues Affecting the Timing for ArcCHECK Recalibration

Purpose: To discuss several factors surrounding the decision on when to recalibrate the ArcCHECK device as well as present a simple and efficient monthly check to evaluate ArcCHECK calibrations. Methods: ArcCheck (Sun Nuclear) calibrations were evaluated monthly by measuring a 25×25cm{sup 2} field with 100 MU. Since ArcCHECK measurements are run on an almost nightly basis, such additional square field measurements are obtained with minimal additional effort. An in-house MATLAB script compares two radial (y-direction) profiles from the top/center of the new measurement relative to a baseline measurement acquired at the last device calibration. The program automatically generates PDF profile and percent difference comparisons for inspection. Recalibration is based on inspection of measurement profile shapes and percent differences from the baseline measurement. Results: The method presented here shows the utility of a simple monthly check for evaluating ArcCHECK calibrations, and in addition shows the importance of recalibrating after Linac beam steering. Our device required recalibration approximately every 8–10 months. However, for ease of scheduling, we propose a bi-annual recalibration interval. Clinics with a lighter/heavier IMRT/VMAT QA case load may require different recalibration intervals, which are easily determined using the single-field method presented. Analysis of additional square fields is also easily incorporated, if desired. We further illustrate the importance of array recalibration given that diode irradiation is not uniform over the entire device, with central diodes receiving more than 900 Gy over the course of 10 months and peripheral diodes receiving as little as 50 Gy (in our experience). Finally, we show that timely device recalibration decreases spread in clinical IMRT/VMAT QA gamma passing rates. Conclusion: Quality assurance for ArcCHECK array calibrations is important to ensure quality IMRT/VMAT QA comparisons. For many clinics, calibrations should be performed at least annually, if not more frequently, based on use of the proposed monthly check.

60 APPLIED LIFE SCIENCES↗

Yield Analysis and Comparison of GaInP/Si and GaInP/GaAs Multi-Terminal Tandem Solar Cells

We present a yield analysis of tandem devices consisting of GaInP top cells on Si or GaAs bottom cells with different terminal configurations. Inputs are the I-V and external quantum efficiency of the individual subcells and the irradiance-dependent module temperature of the bottom cell. Our model calculates the temperature of the tandem module by taking into account the performance, spectral working range and luminescent coupling of the different tandem devices, enabling an irradiance- and weather-dependent yield analysis for these modules. We apply the model to compare two types of two junction devices, a GaInP/GaAs monolithically grown tandem device, and a GaInP top cell stacked on a Si bottom cell, the present two best dual junction devices. When the subcells are series connected both technologies perform equally well. The performance of the GaInP/Si can be significantly improved relatively by 5.8% using 3-terminal (3T) devices with a back-contacted bottom cell instead of a 2T configuration, showing a possible benefit when using Si back contacted cells. For GaInP/Si, the 3T-device works as well as the 4T-device, enabling the integration of monolithic tandem cells into modules at comparably high efficiencies.

14 SOLAR ENERGY↗

Neutron radiation hardness testing of 650V / 7.5 A GaN power HEMT

In this work, we have performed neutron radiation hardness testing for commercially available 650 V/7.5 A GaN power HEMT. The devices were tested at Los Alamos Neutron Science Center (LANSCE) inside Irradiation of Chips Electronics, ICE house-1 at a flux density of 10(6) n/cm(2) -s and energy level above 1 MeV, which is approximately 10(6) times higher than neutron radiation at airliner flight height (30,000 ft). During the experiments, the devices were stressed electrically, thermally and irradiated with neutron radiation. We have observed degradation of AlGaN layer due to accelerated neutron radiation (1.54 x 10(10) n/cm(2) above 1.5 MeV neutron energy) under electrical stress condition. We have performed parametric defect analysis through step-by-step application of neutron irradiation, thermal stress and electrical bias, and observed highest degradation of threshold voltage (0.14 V) for combined electrical stress and neutron irradiation.

36 MATERIALS SCIENCE↗

Effects of Proton Irradiation on GaN Vacuum Electron Nanodiodes

Gallium nitride (GaN)-based nanoscale vacuum electron devices, which offer advantages of both traditional vacuum tube operation and modern solid-state technology, are attractive for radiation-hard applications due to the inherent radiation hardness of vacuum electron devices and the high radiation tolerance of GaN. Here, we investigate the radiation hardness of top-down fabricated n-GaN nanoscale vacuum electron diodes (NVEDs) irradiated with 2.5-MeV protons (p) at various doses. We observe a slight decrease in forward current and a slight increase in reverse leakage current as a function of cumulative protons fluence due to a dopant compensation effect. The NVEDs overall show excellent radiation hardness with no major change in electrical characteristics up to a cumulative fluence of 5E14 p/cm 2 , which is significantly higher than the existing state-of-the-art radiation-hardened devices to our knowledge. In conclusion, the results show promise for a new class of GaN-based nanoscale vacuum electron devices for use in harsh radiation environments and space applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TESTING ACCRETION DISK STRUCTURE WITH SUZAKU DATA OF LMC X-3

The Suzaku observation of LMC X-3 gives the best data to date on the shape of the accretion disk spectrum. This is due to the combination of very low absorbing column density along this line of sight, which allows the shape of the disk emission to be constrained at low energies by the CCDs while the tail can be simultaneously determined up to 30 keV by the high-energy detectors. These data clearly demonstrate that the observed disk spectrum is broader than a simple 'sum of blackbodies', and relativistic smearing of the emission is strongly required. However, the intrinsic emission should be more complex than a (color-corrected) sum of blackbodies as it should also contain photoelectric absorption edges from the partially ionized disk photosphere. These are broadened by the relativistic smearing, but the models predict {approx}3%-5% deviations for 1/3-1 solar abundance around the edge energies, significantly stronger than observed. This indicates that the models need to include more physical processes such as self-irradiation, bound-bound (line) absorption, and/or emission from recombination continua and/or lines. Alternatively, if none of these match the data, it may instead require that the accretion disk density and/or emissivity profile with height is different to that assumed. Thus, these data demonstrate the feasibility of observational tests of our fundamental understanding of the vertical structure of accretion disks.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute cavity pyrgeometer

Implementations of the present disclosure involve an apparatus and method to measure the long-wave irradiance of the atmosphere or long-wave source. The apparatus may involve a thermopile, a concentrator and temperature controller. The incoming long-wave irradiance may be reflected from the concentrator to a thermopile receiver located at the bottom of the concentrator to receive the reflected long-wave irradiance. In addition, the thermopile may be thermally connected to a temperature controller to control the device temperature. Through use of the apparatus, the long-wave irradiance of the atmosphere may be calculated from several measurements provided by the apparatus. In addition, the apparatus may provide an international standard of pyrgeometers' calibration that is traceable back to the International System of Units (SI) rather than to a blackbody atmospheric simulator.

47 OTHER INSTRUMENTATION↗

Analysis of hopping conduction in semiconducting and metallic carbon nanotube devices

Single-walled carbon nanotube field-effect transistors were irradiated with 20 keV electrons using an e-beam lithography exposure method. Analysis of conduction data in the temperature range from 25 to 300 K indicated the creation of insulating regions containing traps along the nanotube channel. Further analysis of semiconducting and metallic nanotube devices shows dramatic differences in the effect of the electron exposure on the hopping defect barrier heights. Barriers for metallic nanotubes saturate at significantly larger values than semiconducting nanotubes due to shorter localization lengths. The limited and near constant density of states at the Fermi level induces a larger hopping length to localization length ratio, further limiting current and increasing measured trap heights. Poole-Frenkel hopping with an adjustment for electron localization is utilized to explain the inconsistencies. n-type and p-type barriers in the nanotube devices displayed exponential dependence on applied gate voltage bias, with the peak barrier height in the metallic device defining a switch of majority carrier.

36 MATERIALS SCIENCE↗

Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume

Purpose: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination of the MD active surface area and active volume. Methods: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. Results: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in the 2D response maps. Conclusions: The obtained results demonstrate the high reproducibility of the MD fabrication process. The observed discrepancies among the output correction factors reported by several authors for MD response in very small fields are very unlikely to be ascribed to unintentional variations of the device active surface area and volume. It is the opinion of the authors that the role of the volume averaging as well as of other perturbation effects should be separately investigated instead, both experimentally and by Monte Carlo simulations, in order to better clarify the behaviour of the MD response in very small fields.

60 APPLIED LIFE SCIENCES↗

Design and Analysis of an Advanced Three-Point Bend Test Approach for Miniature Irradiated Disk Specimens

Candidate tungsten armor materials in a magnetic confinement fusion device must be able to withstand thermal variation that leads to internal stresses caused by the impinging heat load. In addition, the thermomechanical properties of these materials are degraded by irradiation-induced defect accumulation. Fission reactor–based irradiation data are used to predict the fusion neutron damage and property change. This study examines the motivation and design of a custom-designed three-point bend test for neutron-irradiated disk specimens that are 3 mm in diameter to be able to define the flexural strength of advanced tungsten materials, alloys, and composites—and to the extent that embrittlement occurs after neutron irradiation. The theory provided shows a calculation for the flexural deflection and shear deflection due to the small-geometry constraints. A finite element deformation analysis is performed to evaluate the mechanical stress field of disk bend specimens. The stress values above 80% of the maximum stress are concentrated in 2.4 mm of the 3.0-mm length of the centerline across the tungsten disk diameter. A bend test fixture has been designed and fabricated to enable testing of these specimens with precisely engineered tolerance and minimal machine compliance. This fixture will be able to be placed inside a universal testing frame at elevated temperatures for the mechanical property evaluation of future neutron-irradiated disk specimens.

36 MATERIALS SCIENCE↗