Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a still preclinical tumor therapy approach that uses arrays of a few tens of micrometer wide parallel beams separated by a few 100 μm. The production, measurement, and planning of such radiation fields are a challenge up to now. Here, the authors investigate the feasibility of radiochromic film dosimetry in combination with a microscopic readout as a tool to validate peak and valley doses in MRT, which is an important requirement for a future clinical application of the therapy. Methods: Gafchromic{sup ®} HD-810 and HD-V2 films are exposed to MRT fields at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF) and are afterward scanned with a microscope. The measured dose is compared with Monte Carlo calculations. Image analysis tools and film handling protocols are developed that allow accurate and reproducible dosimetry. The performance of HD-810 and HD-V2 films is compared and a detailed analysis of the resolution, noise, and energy dependence is carried out. Measurement uncertainties are identified and analyzed. Results: The dose was measured with a resolution of 5 × 1000 μm{sup 2} and an accuracy of 5% in the peak and between 10% and 15% in the valley region. As main causes for dosimetry uncertainties, statistical noise, film inhomogeneities, and calibration errors were identified. Calibration errors strongly increase at low doses and exceeded 3% for doses below 50 and 70 Gy for HD-V2 and HD-810 films, respectively. While the grain size of both film types is approximately 2 μm, the statistical noise in HD-V2 is much higher than in HD-810 films. However, HD-810 films show a higher energy dependence at low photon energies. Conclusions: Both film types are appropriate for dosimetry in MRT and the microscope is superior to the microdensitometer used before at the ESRF with respect to resolution and reproducibility. However, a very careful analysis of the image data is required. Dosimetry at low photon energies should be performed with great caution due to the energy sensitivity of the films. In this respect, HD-V2 films showed to have an advantage over HD-810 films. However, HD-810 films have a lower statistical noise level. When a higher resolution is required, e.g., for the dosimetry of pencil beam irradiations, noise may render HD-V2 films inapplicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BioSig-Air-Force

1) Configured servers: In coordination with the INSIGHT team, a hardware configuration was selected. Two nodes were purchased, configured, and shipped with compatible OS and database installation. The servers have been stress tested for reliability as they use leading edge technologies. Each node has two CPUs and 12 cores per CPU with maximum onboard memory for high performance. 2) LIM and Experimental module: The original BioSig system was developed for cancer research. Accordingly, the LIM system its corresponding web pages are being modified to facilitate (i) pathogene-donor interactions, (ii) media composition, (iii) chemical and siRNA plate configurations. The LIM system has been redesigned. The revised system allows design of new media and tracking it from lot-to-lot so that variations in the phenotypic responses can be tracked to a specific media and lot number. Similar associations are also possible with other experimental factors (e.g., donor-pathoge, siRNA, and chemical). Furthermore, the design of the experimental variables has also been revised to (i) interact with the newly developed LIM system, (ii) simplify experimental specifications, and (iii) test for potential operator's error during the data entry. Part of the complication has been due to the handshake between multiple teams that provide the small molecule plates and the team that creates assay plates. Our efforts have focused to harmonize these interactions (e.g., various data formats) so that each assay plate can be mapped to its source so that a correct set of experimental variables can be associated with each image. For example, depending upon the source of the chemical plates, they may have different formats. We have developed a canonical representation that registers SMILES code, for each chemical compound, along with its physiochemical properties. The schema for LIM conjunction with customized Web pages. 3) Import of Images and computed descriptors module: In coordination with the INSIGHT team, policies were designed to route images and computed representation into BioSig. This module (i) examines for completion of image analysis, and imports images, computed masks, and descriptors into BioSig. A database API for efficient retrieval of selection of descriptors (among thousands) was designed and implemented. 4) Computed segmentation masks from external software were imported, boundaries computed, and overlaid on images for quality control.

Source record↗

SU-E-J-260: Quantitative Image Feature Analysis of Multiphase Liver CT for Hepatocellular Carcinoma (HCC) in Radiation Therapy

Purpose: To identify the effective quantitative image features (radiomics features) for prediction of response, survival, recurrence and metastasis of hepatocellular carcinoma (HCC) in radiotherapy. Methods: Multiphase contrast enhanced liver CT images were acquired in 16 patients with HCC on pre and post radiation therapy (RT). In this study, arterial phase CT images were selected to analyze the effectiveness of image features for the prediction of treatment outcome of HCC to RT. Response evaluated by RECIST criteria, survival, local recurrence (LR), distant metastasis (DM) and liver metastasis (LM) were examined. A radiation oncologist manually delineated the tumor and normal liver on pre and post CT scans, respectively. Quantitative image features were extracted to characterize the intensity distribution (n=8), spatial patterns (texture, n=36), and shape (n=16) of the tumor and liver, respectively. Moreover, differences between pre and post image features were calculated (n=120). A total of 360 features were extracted and then analyzed by unpaired student’s t-test to rank the effectiveness of features for the prediction of response. Results: The five most effective features were selected for prediction of each outcome. Significant predictors for tumor response and survival are changes in tumor shape (Second Major Axes Length, p= 0.002; Eccentricity, p=0.0002), for LR, liver texture (Standard Deviation (SD) of High Grey Level Run Emphasis and SD of Entropy, both p=0.005) on pre and post CT images, for DM, tumor texture (SD of Entropy, p=0.01) on pre CT image and for LM, liver (Mean of Cluster Shade, p=0.004) and tumor texture (SD of Entropy, p=0.006) on pre CT image. Intensity distribution features were not significant (p>0.09). Conclusion: Quantitative CT image features were found to be potential predictors of the five endpoints of HCC in RT. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

The persistent shadow of the supermassive black hole of M 87. I. Observations, calibration, imaging, and analysis

In April 2019, the Event Horizon Telescope (EHT) Collaboration reported the first-ever event-horizon-scale images of a black hole, resolving the central compact radio source in the giant elliptical galaxy M 87. These images reveal a ring with a southerly brightness distribution and a diameter of ∼42 μas, consistent with the predicted size and shape of a shadow produced by the gravitationally lensed emission around a supermassive black hole. These results were obtained as part of the April 2017 EHT observation campaign, using a global very long baseline interferometric radio array operating at a wavelength of 1.3 mm. Here, we present results based on the second EHT observing campaign, taking place in April 2018 with an improved array, wider frequency coverage, and increased bandwidth. In particular, the additional baselines provided by the Greenland telescope improved the coverage of the array. Multiyear EHT observations provide independent snapshots of the horizon-scale emission, allowing us to confirm the persistence, size, and shape of the black hole shadow, and constrain the intrinsic structural variability of the accretion flow. We have confirmed the presence of an asymmetric ring structure, brighter in the southwest, with a median diameter of 43.3−3.1+1.5 μas. The diameter of the 2018 ring is remarkably consistent with the diameter obtained from the previous 2017 observations. On the other hand, the position angle of the brightness asymmetry in 2018 is shifted by about 30° relative to 2017. The perennial persistence of the ring and its diameter robustly support the interpretation that the ring is formed by lensed emission surrounding a Kerr black hole with a mass ∼6.5 × 109 M⊙. The significant change in the ring brightness asymmetry implies a spin axis that is more consistent with the position angle of the large-scale jet.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of mechanical properties and deformation behavior of highly irradiated 316L stainless steel from target modules at the Spallation Neutron Source using digital image correlation analysis

Tensile specimens with irradiation doses ranging from approximately 0.7 to 7.6 displacements per atom (dpa) were fabricated from 316L samples removed from Spallation Neutron Source (SNS) target vessels after service. Tensile tests were performed in conjunction with digital image correlation (DIC) characterization, which permitted detailed analysis of the strain distribution and deformation behavior of the specimen gauge sections during testing. The results show, while considerable hardening (500–700 MPa increase in yield strength) occurred in the 316L SNS target material with increasing dose, appreciable ductility (19–23% total elongation) remained in the material after irradiation to 7.6 dpa in the mixed neutron/proton environment of the SNS target region. The DIC data showed the strain distribution and deformation behavior of all irradiated specimens were nonuniform during testing. Strain localization in the form of deformation bands or “hotspots” was observed during testing, and in some specimens, the bands propagated as deformation waves along the gauge section. The “traveling wave” deformation behavior affected the amount of elongation each specimen achieved, and the scatter in the elongation data was attributed to the large variation in deformation behavior observed among different specimens. Bands of localized strain, or deformation bands, oriented at specific angles were observed in two-dimensional plots of the strain distribution in the gauge sections of some specimens. Overall, this paper describes the experimental procedures, results, and deformation behavior of tensile specimens from SNS targets after service and illustrates the value of DIC characterization during tensile testing of irradiated materials.

36 MATERIALS SCIENCE↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Reference tissue normalization in longitudinal 18F-florbetapir positron emission tomography of late mild cognitive impairment

Background: Semiquantitative methods such as the standardized uptake value ratio (SUVR) require normalization of the radiotracer activity to a reference tissue to monitor changes in the accumulation of amyloid-β (Aβ) plaques measured with positron emission tomography (PET). The objective of this study was to evaluate the effect of reference tissue normalization in a test–retest 18F-florbetapir SUVR study using cerebellar gray matter, white matter (two different segmentation masks), brainstem, and corpus callosum as reference regions. Methods: We calculated the correlation between 18F-florbetapir PET and concurrent cerebrospinal fluid (CSF) Aβ1–42 levels in a late mild cognitive impairment cohort with longitudinal PET and CSF data over the course of 2 years. In addition to conventional SUVR analysis using mean and median values of normalized brain radiotracer activity, we investigated a new image analysis technique—the weighted two-point correlation function (wS2)—to capture potentially more subtle changes in Aβ-PET data. Results: Compared with the SUVRs normalized to cerebellar gray matter, all cerebral-to-white matter normalization schemes resulted in a higher inverse correlation between PET and CSF Aβ1–42, while the brainstem normalization gave the best results (high and most stable correlation). Compared with the SUVR mean and median values, the wS2 values were associated with the lowest coefficient of variation and highest inverse correlation to CSF Aβ1–42 levels across all time points and reference regions, including the cerebellar gray matter. Conclusions: The selection of reference tissue for normalization and the choice of image analysis method can affect changes in cortical 18F-florbetapir uptake in longitudinal studies.

59 BASIC BIOLOGICAL SCIENCES↗

Conditional random fields for pattern recognition applied to structured data

Pattern recognition uses measurements from an input domain, X, to predict their labels from an output domain, Y. Image analysis is one setting where one might want to infer whether a pixel patch contains an object that is “manmade” (such as a building) or “natural” (such as a tree). Suppose the label for a pixel patch is “manmade”; if the label for a nearby pixel patch is then more likely to be “manmade” there is structure in the output domain that can be exploited to improve pattern recognition performance. Modeling P(X) is difficult because features between parts of the model are often correlated. Therefore, conditional random fields (CRFs) model structured data using the conditional distribution P(Y|X = x), without specifying a model for P(X), and are well suited for applications with dependent features. This paper has two parts. First, we overview CRFs and their application to pattern recognition in structured problems. Our primary examples are image analysis applications in which there is dependence among samples (pixel patches) in the output domain. Second, we identify research topics and present numerical examples.

97 MATHEMATICS AND COMPUTING↗

MR texture analysis: potential imaging biomarker for predicting the chemotherapeutic response of patients with colorectal liver metastases

Purpose: The purpose of the study was to determine whether the pre-treated MR texture features of colorectal liver metastases (CRLMs) are predictive of therapeutic response after chemotherapy. Methods: The study included twenty-six consecutive patients (a total of 193 liver metastasis) with unrespectable CRLMs at our institution from August 2014 to February 2016. Lesions were categorized into either responding group or non-responding group according to changes in size. Texture analysis was quantified on T2-weighted images by two radiologists with consensus on regions of interest which were manually drawn on the largest cross-sectional area of the lesions. Five histogram features (mean, variance, skewness, kurtosis, and entropy{sup 1}) and five gray level co-occurrence matrix features (GLCM; angular second moment (ASM), entropy{sup 2}, contrast, correlation, and inverse difference moment (IDM)) were extracted. The texture parameters were statistically analyzed to identify the differences between the two groups, and the potential predictive parameters to differentiate the responding group from the non-responding group were subsequently tested using multivariable logistic regression analysis. Results: A total of 107 responding and 86 non-responding lesions were evaluated. A higher variance, entropy{sup 1}, contrast, entropy{sup 2} and a lower ASM, correlation, IDM were independently (P < 0.05) associated with a good response to chemotherapy with the areas under the ROC curves (AUCs) of 0.602–0.784. Variance (P < 0.001) and ASM (P = 0.001) remained potential predictive values to discriminate responding lesions from non-responding lesions when tested using multivariable logistic regression analysis. The highest AUC of the predictors from the association of variance and ASM was 0.814. Conclusion: MR texture features on pre-treated T2 images have the potential to predict the therapeutic response of colorectal liver metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient Workflows for Curation of Heterogeneous Data Supporting Modeling of U-Nb Alloy Aging

These are slides from a presentation summarizing a graduate research associate's summer project. The following topics are covered in these slides: data challenges in materials, aging in U-Nb Alloys, Building an Aging Model, Different Phase Trans. in U-Nb, the Challenge, Storing Materials Data, Example Data Source, Organizing Data: What is a Schema?, What does a "XML Schema" look like?, Our Data Schema: Nice and Simple, Storing Data: Materials Data Curation System (MDCS), Problem with MDCS: Slow Data Entry, Getting Literature into MDCS, Staging Data in Excel Document, Final Result: MDCS Records, Analyzing Image Data, Process for Making TTT Diagram, Bottleneck Number 1: Image Analysis, Fitting a TTP Boundary, Fitting a TTP Curve: Comparable Results, How Does it Compare to Our Data?, Image Analysis Workflow, Curating Hardness Records, Hardness Data: Two Key Decisions, Before Peak Age? - Automation, Interactive Viz, Which Transformation?, Microstructure-Informed Model, Tracking the Entire Process, General Problem with Property Models, Pinyon: Toolkit for Managing Model Creation, Tracking Individual Decisions, Jupyter: Docs and Code in One File, Hardness Analysis Workflow, Workflow for Aging Models, and conclusions.

36 MATERIALS SCIENCE↗

SU-C-BRF-02: Surface Imaging Based Analysis of Intra-Fraction Motion for Breast Radiotherapy Patients

Purpose: To quantify and characterize intrafraction motion for breast radiotherapy treatments using 3D surface imaging. Methods: Thirty free breathing breast patients were monitored with 3D surface imaging over a total of 831 monitoring sessions. Mean translations and rotations were calculated over each minute, each session, and over all sessions combined. The percentage of each session that the root mean square (RMS) of the linear translations were outside of 2 mm, 3 mm, 4 mm, and 5 mm were determined for each patient. Correlations between mean translations per minute and time and between standard deviation per minute and time were evaluated using Pearson's r value. Results: The mean RMS translation averaged over all patients was 2.63 mm +/- 1.63 mm. The patients spent an average of 52%, 24%, 11%, and 5% of the monitoring time outside of 2 mm, 3 mm, 4 mm, and 5 mm RMS tolerances, respectively. The RMS values averaged over all patients were 2.95 mm +/- 1.67 mm, 3.21 +/- 2.11, and 3.57 mm +/- 2.23 mm over the 5th, 10th, and 15th minutes of monitoring, respectively. The RMS values (r = 0.95, p = 0) and the standard deviations of the RMS values (r = 0.97, p = 0) both showed strong significant correlations with time. Conclusion: The majority of patients treatment time is spent within 5 mm of the isocenter. Patient position tends to drift with increasing time in the session. Treatment length should be considered when determining planning margins. An 8 mm margin on a target volume would account for two standard deviations of motion for a treatment up to 15 minutes in length.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions, which is valuable for the early diagnosis of certain brain diseases, e.g. multiple sclerosis.

60 APPLIED LIFE SCIENCES↗

Mirostructure Characterization of Friction Consolidated Copper-Nickel using a Machine Learning Approach: Developing Process to Microstructure Associations

Friction consolidation (FC) is a solid phase processing approach where discrete material forms such as powders, chips, nuggets, etc. are densified via shear deformation. The precursors are placed in a billet container and brought in contact with a rotating tool that applying the desirable amount of normal force. Under the combined action of the rotation and normal pressure, the discrete precursor is consolidated through porosity reduction and shear deformation. FC is increasingly being studied as an attractive approach to manufacturing fully dense parts from powder forms owing to its ability to mix, alloy and consolidate difficult-to-process precursors in minimal number of process steps. Material consolidation and deformation in shear consolidation processes have been studied extensively previously for different material combinations previously. However, despite the extensive research in this area, understanding of the mechanistic processes in pore consolidation, deformation-induced mixing and material solubility during FC is still evolving. Material development using solid phase processing approaches such as FC is often performed based on research experience/education, which can be biased. Conventional analysis and simulation tools in this area tend to be successful only when material thermodynamic pathways and microstructural evolution sequences resulting from processing are clearly defined or known. They are not as effective for emerging advanced manufacturing technologies where material evolution pathways are not well established. The ability to predict optimal process parameters based on material chemistry and bulk properties is essential to accelerate materials design and processing, as are an understanding of the relevant structure-processing-property relationships. These structure-processing-property-performance relationships are at the core of materials science research. Microstructure characterization provides the link to these four core areas, often through visualizing material microstructure using imaging techniques. However, linking microstructure image data (i.e., micrographs) to variables of interest (e.g., processing parameters, material chemistry) in a reproducible, generalizable, and quantitative manner is a significant challenge. Typically, quantitatively linking image data to processing history relies on significant domain knowledge and manual or subject matter expert (SME)-heuristic based image analysis. Such an approach to image analysis has the potential to be biased, inefficient, and difficult to replicate.

36 MATERIALS SCIENCE↗

Advanced Characterization of Unconventional Oil and Gas Reservoirs to Enhance CO 2 Storage Resource Estimates – Organic Structure and Porosity of Organic Rich Shales

Poster presented at Mastering the Subsurface Through Technology Innovation, Partnerships and Collaboration: Carbon Storage and Oil and Natural Gas Technologies Review Meeting, Pittsburgh, Pennsylvania, August 1–3, 2017. Advanced analytical and image analysis techniques have been employed to examine the detailed structure of organic matter (OM) in the shales of the Bakken Formation. Samples from three different locations in the Bakken Formation with varying levels of thermal maturity (immature, marginally mature, and mature) were selected for analysis. The goal of this project is to use an advanced field emission scanning electron microscope (FESEM), image analysis, and computed tomography (CT) visualization techniques to identify and quantify key features that could affect CO 2 storage in unconventional formations.

02 PETROLEUM↗

Major to trace element imaging and analysis of iron age glasses using stage scanning in the analytical dual beam microscope (tandem)

Dark and clear silicate glasses formed during an iron age vitrification event ≈ 1500 years ago at the Broborg hillfort near Uppsala, Sweden have been analyzed using a scanning electron microscope equipped with a micro-X-ray fluorescence (μXRF) spectrometer. Correlated µXRF and electron beam-induced energy dispersive spectrometry (EDS) X-ray maps were collected via stage-scanning at constant velocity. This coupled procedure represents a new approach for the cultural heritage community to conduct analytical studies of archaeometric specimens composed of metal, ceramic, or mixed inorganic/organic materials, where major and trace element compositions are registered in space for areas up to the centimeter-length scale at micrometer-scale resolution. Overview images were used to select areas for EDS beam scan maps correlated with multispectral cathodoluminescence (CL) imaging and co-located quantitative EDS and μXRF point analysis. Fe, Ca, Mg, Ti, P, Mn, Zr, Zn, and Y are enriched in the dark glass, while Si, Al, K, Na, Ba, Sr, Rb, and Ga are enriched in the clear glass. Unmelted material is comprised predominately of quartz (SiO 2 ) along with trace apatite (Ca 5 (PO 4 ) 3 [Cl,OH]) and zircon (ZrSiO 4 ). Multivariate statistical analysis was used to measure the area fractions of high variance components while lower variance components represented phase mixtures. Differences between calculated melt viscosities for the glass compositions are consistent with field and laboratory observations. Coupled large area EDS and μXRF imaging shows significant promise for informed selection of higher spatial resolution and higher sensitivity follow-up studies, e.g., those performed using synchrotron analysis.

36 MATERIALS SCIENCE↗

An siRNA-based screen in C2C12 myoblasts identifies novel genes involved in myogenic differentiation

Myogenesis is a highly regulated multi-step process involving myoblast proliferation and differentiation. Although studies over the last decades have identified several factors governing these distinct major phases, many of them are not yet known. In order to identify novel genes, we took advantage of the C2C12 myoblastic line to establish a functional siRNA screen combined with quantitative-imaging analysis of a large amount of differentiated myoblasts. We knocked down 100 preselected mouse genes without a previously characterized role in muscle. Using image analysis, we tracked gene-silencing phenotypes by quantitative assessment of cellular density, myotube quantity, myotube morphology and fusion index. Our results have revealed six genes involved in both stages of C2C12 myogenesis and 13 genes specific to the differentiation stage. These findings prove that our RNAi-based screen could be an efficient tool to detect clear and subtle phenotypes allowing the identification of new myogenic regulators in mammals. - Highlights: • A new optimized protocol to perform a functional siRNA based screen. • 100 preselected genes knocked-down in C2C12 myoblastic cell line. • 19 candidates genes identified as novel myogenic actors.

60 APPLIED LIFE SCIENCES↗