Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging & optical processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Generation of realistic input parameters for simulating atmospheric point-spread functions at astronomical observatories

High-fidelity simulated astronomical images are an important tool in developing and measuring the performance of image-processing algorithms, particularly for high precision measurements of cosmic shear – correlated distortions of images of distant galaxies due to weak gravitational lensing caused by the large-scale mass distribution in the Universe. For unbiased measurements of cosmic shear, all other sources of correlated image distortions must be modeled or removed. One such source is the correlated blurring of images due to optical turbulence in the atmosphere, which dominates the point-spread function (PSF) for ground-based instruments. In this work, we leverage data from weather forecasting models to produce wind speeds and directions, and turbulence parameters, that are realistically correlated with altitude. To study the resulting correlations in the size and shape of the PSF, we generate simulated images of the PSF across a ~10 square-degree field of view – the size of the camera focal plane for the Vera C. Rubin Observatory in Chile – using weather data and historical seeing for a geographic location near the Observatory. We make quantitative predictions for two-point correlation functions (2PCF) that are used in analyses of cosmic shear. We observe a strong anisotropy in the two-dimensional 2PCF, which is expected based on observations in real images, and study the dependence of the orientation of the anisotropy on dominant wind directions near the ground and at higher altitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

Neural network methods for radiation detectors and imaging

Recent advances in image data proccesing through deep learning allow for new optimization and performance-enhancement schemes for radiation detectors and imaging hardware. This enables radiation experiments, which includes photon sciences in synchrotron and X-ray free electron lasers as a subclass, through data-endowed artificial intelligence. We give an overview of data generation at photon sources, deep learning-based methods for image processing tasks, and hardware solutions for deep learning acceleration. Most existing deep learning approaches are trained offline, typically using large amounts of computational resources. However, once trained, DNNs can achieve fast inference speeds and can be deployed to edge devices. A new trend is edge computing with less energy consumption (hundreds of watts or less) and real-time analysis potential. While popularly used for edge computing, electronic-based hardware accelerators ranging from general purpose processors such as central processing units (CPUs) to application-specific integrated circuits (ASICs) are constantly reaching performance limits in latency, energy consumption, and other physical constraints. These limits give rise to next-generation analog neuromorhpic hardware platforms, such as optical neural networks (ONNs), for high parallel, low latency, and low energy computing to boost deep learning acceleration (LA-UR-23-32395).

edge computing↗

Single-Objective Airy Light-Sheet Imaging

Despite its massive potential, standard light-sheet imaging (LSI) faces key challenges, such as the incompatibility with common sample mounting techniques and low-resolution imaging. Single-objective LSI attempts to address these issues but often suffers from limited fields-of-view and throughput rates, or requires multiple optics that increase costs, alignment complexity, and losses. To overcome these challenges of standard single-objective LSI, we introduce single-objective Airy light-sheet imaging (SoALSI). SoALSI leverages the extraordinary self-acceleration properties of the Airy beam, achieving 5× higher imaging rates and enhanced imaging efficiency than standard single-objective LSI. Here, we demonstrate SoALSI’s versatility through rigorous contrast and resolution characterizations and by high-resolution imaging of diverse biological specimens, including malaria parasite-infected red blood cells and plant root tissue. SoALSI seamlessly integrates with any standard inverted microscope frame, enabling broader accessibility for the bioimaging community to explore biological processes in a wide range of specimens with enhanced resolution and imaging contrast.

airy beam↗

Tomographic FLEET with a wedge array for multi-point three-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) velocimetry is an important diagnostic technique for seedless velocimetry measurements particularly in supersonic and hypersonic flows. Typical FLEET measurements feature a single laser line and camera system to achieve one-component velocimetry along a line, although some multiple-spot and multiple-component configurations have been demonstrated. In this work, tomographic imaging is used to track the three-dimensional location of many FLEET spots. A quadscope is used to combine four unique views onto a single high-speed image intensifier and camera. Tomographic reconstructions of the FLEET emission are analyzed for three-component velocimetry from multiple FLEET spots. Glass wedges are used to create many (nine) closely spaced FLEET spots with less than 10% transmission losses. These developments lead to a significant improvement in the dimensionality and spatial coverage of a FLEET instrument with some increases in experimental complexity and data processing. Multiple-point three-component FLEET velocimetry is demonstrated in an underexpanded jet.

47 OTHER INSTRUMENTATION↗

Enabling Particulate Materials Processing Science for High-Consequence, Small-Lot Precision Manufacturing

This Laboratory Directed Research and Development project developed and applied closely coupled experimental and computational tools to investigate powder compaction across multiple length scales. The primary motivation for this work is to provide connections between powder feedstock characteristics, processing conditions, and powder pellet properties in the context of powder-based energetic components manufacturing. We have focused our efforts on multicrystalline cellulose, a molecular crystalline surrogate material that is mechanically similar to several energetic materials of interest, but provides several advantages for fundamental investigations. We report extensive experimental characterization ranging in length scale from nanometers to macroscopic, bulk behavior. Experiments included nanoindentation of well-controlled, micron-scale pillar geometries milled into the surface of individual particles, single-particle crushing experiments, in-situ optical and computed tomography imaging of the compaction of multiple particles in different geometries, and bulk powder compaction. In order to capture the large plastic deformation and fracture of particles in computational models, we have advanced two distinct meshfree Lagrangian simulation techniques: 1.) bonded particle methods, which extend existing discrete element method capabilities in the Sandia-developed , open-source LAMMPS code to capture particle deformation and fracture and 2.) extensions of peridynamics for application to mesoscale powder compaction, including a novel material model that includes plasticity and creep. We have demonstrated both methods for simulations of single-particle crushing as well as mesoscale multi-particle compaction, with favorable comparisons to experimental data. We have used small-scale, mechanical characterization data to inform material models, and in-situ imaging of mesoscale particle structures to provide initial conditions for simulations. Both mesostructure porosity characteristics and overall stress-strain behavior were found to be in good agreement between simulations and experiments. We have thus demonstrated a novel multi-scale, closely coupled experimental and computational approach to the study of powder compaction. This enables a wide range of possible investigations into feedstock-process-structure relationships in powder-based materials, with immediate applications in energetic component manufacturing, as well as other particle-based components and processes.

36 MATERIALS SCIENCE↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Uncertainty analysis of PIV measurements in bubbly flows considering sampling and bubble effects with ray optics modeling

In this report, a modeling-based approach is developed to investigate the external sources of uncertainty in particle image velocimetry (PIV) measurements for two-phase bubbly flows. Primarily relied on ray optics modeling, this study focuses on the uncertainty in PIV measurements due to bubble-induced light distortion. In addition, the uncertainty due to sampling is also considered through synthetic PIV images generated from Monte Carlo sampling. Based on a PIV-planar laser induced florescence (PLIF) measurement system, three case studies are performed and discussed, considering respectively the sampling effect, bubble effect, and the combination of these two effects. These case studies confirm the validity of the ray optics modeling in obtaining accurate particle images through a benchmark test. Furthermore, it is also found that the bubble effect could significantly influence the particle images. On the other hand, the result of the case study with synthetic PIV images indicates that the bubble effect on particle images can be minimized by removing “outliers” in the obtained velocity vector field through a multi-pass post-processing procedure. However, the uncertainty of the velocity measurements will still increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SDSS-IV MaNGA: The incidence of major mergers in type I and II AGN host galaxies in the DR15 sample

We present a study on the incidence of major mergers and their impact on the triggering of nuclear activity in 47 type I and 236 type II optically selected AGN from the MaNGA DR15 sample. From an estimate of non-parametric image predictors (Gini, M_20, concentration (C), asymmetry (A), clumpiness (S), Sérsic index (n), and shape asymmetry ()) using the SDSS images, in combination with a Linear Discriminant Analysis Method, we identified major mergers and merger stages. We reinforced our results by looking for bright tidal features in our post-processed SDSS and DESI legacy images. We find a statistically significant higher incidence of major mergers of 29 per cent ± 3 per cent in our type I+II AGN sample compared to 22 per cent ± 0.8 per cent for a non-AGN sample matched in redshift, stellar mass, colour, and morphological type, finding also a prevalence of post-coalescence (51 per cent ± 5 per cent) over pre-coalescence (23 per cent ± 6 per cent) merger stages. The levels of AGN activity among our massive major mergers are similar to those reported in other works using [O iii] tracers. However, similar levels are produced by our AGN-galaxies hosting stellar bars, suggesting that major mergers are important promoters of nuclear activity but are not the main nor the only mechanism behind the AGN triggering. The tidal strength parameter Q was considered at various scales looking for environmental differences that could affect our results on the merger incidence, finding non-significant differences. Finally, the H-H β diagram could be used as an empirical predictor for the flux coming from an AGN source, useful to correct photometric quantities in large AGN samples emerging from surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

Image registration for accurate electrode deformation analysis in operando microscopy of battery materials

Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.

Sun, Tianxiao↗

Simultaneous imaging of two-phase velocities in particle-laden flows by two-color optical phase discrimination

In this Letter, we present a particle image/tracking velocimetry (PIV/PTV) technique for simultaneous velocity measurement of both fluid and particle phases, adopting newly developed optical phase discrimination methods and novel optical particles. Spherical acrylic (PMMA) particles of diameter ∼ <#comment/> O ( 100 µ <#comment/> m ) were used as the particle phase, while fine B A M : E u 2 + phosphors of diameter ∼ <#comment/> O ( 1 µ <#comment/> m ) were used as the fluid tracer. Under Nd:YAG 355 nm laser excitation, both the laser-induced fluorescence (LIF) from PMMA and laser-induced phosphorescence (LIP) from B A M : E u 2 + provided sufficiently strong signals for PIV imaging with two non-intensified cameras and were clearly separable for phase discrimination using spectral filters and temporal profiles. The advantages of the PIV/PTV method include the relatively low cost of B A M : E u 2 + phosphors, high sphericity and narrow size distribution of PMMA particles with LIF emission, and direct optical discrimination eliminating artifacts, while requiring much less computational capacity for PIV/PTV processing of complex particle-laden flows.

Bi, Xiaopeng (ORCID:0000000190847325)↗

Fundamental insights on ignition and combustion of natural gas in an active fueled pre-chamber spark-ignition system

Pre-chamber spark-ignition (PCSI), either fueled or non-fueled, is a leading concept with the potential to enable diesel-like efficiency in medium-duty (MD) and heavy-duty (HD) natural gas (NG) engines. However, the inadequate scientific base and simulation tools to describe/predict the underlying processes governing PCSI systems is one of the key barriers to market penetration of PCSI for MD/HD NG engines. To this end, experiments were performed in a heavy-duty, optical, single-cylinder engine fitted with an active fueled PCSI module. Furthermore, the spatial and temporal progress of ignition and subsequent combustion of lean-burn natural gas using PCSI system were studied using optical diagnostic imaging and heat release analysis based on main-chamber and pre-chamber pressure measurements.

42 ENGINEERING↗

Boiling Transitions During Droplet Contact on Superheated Nano/Micro-Structured Surfaces

Manipulating surface topography is one of the most promising strategies for increasing the efficiency of numerous industrial processes involving droplet contact with superheated surfaces. In such scenarios, the droplets may immediately boil upon contact, splash and boil, or could levitate on their own vapor in the Leidenfrost state. In this work we report the outcomes of water droplets coming in gentle contact with designed nano/micro-textured surfaces at a wide range of temperatures as observed using high-speed optical and X-ray imaging. Further, we report a paradoxical increase in the Leidenfrost temperature ($T_{\text{LFP}}$) as the texture spacing is reduced below a critical value (~10 μm) that represents a minima in $T_{\text{LFP}}$. Although droplets on such textured solids appear to boil upon contact, our studies suggest that their behavior is dominated by hydrodynamic instabilities implying that the increase in $T_{\text{LFP}}$ may not necessarily lead to enhanced heat transfer. On such surfaces, the droplets display a new regime characterized by splashing accompanied by a vapor jet penetrating through the droplets before they transition to the Leidenfrost state. We provide a comprehensive map of boiling behavior of droplets over a wide range of texture spacings that may have significant implications towards applications such as electronics cooling, spray cooling, nuclear reactor safety and containment of fire calamities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging↗

AGNs in post-mergers from the ultraviolet near infrared optical northern survey

The kinematic disturbances associated with major galaxy mergers are known to produce gas inflows, which in turn may trigger accretion onto the supermassive black holes (SMBH) of the participant galaxies. While this effect has been studied in galaxy pairs, the frequency of active galactic nuclei (AGNs) in fully coalesced post-merger systems is poorly constrained due to the limited size or impurity of extant post-merger samples. Previously, we combined convolutional neural network (CNN) predictions with visual classifications to identify a highly pure sample of 699 post-mergers in deep r-band imaging. In the work presented here, we quantify the frequency of AGNs in this sample using three metrics: optical emission lines, mid-infrared (mid-IR) colour, and radio detection of low-excitation radio galaxies (LERGs). We also compare the frequency of AGNs in post-mergers to that in a sample of spectroscopically identified galaxy pairs. We find that AGNs identified by narrow-line optical emission and mid-IR colour have an increased incidence rate in post-mergers, with excesses of ~4 over mass- and redshift-matched controls. The optical and mid-IR AGN excesses in post-mergers exceed the values found for galaxy pairs, indicating that AGN activity in mergers peaks after coalescence. Conversely, we recover no significant excess of LERGs in post-mergers or pairs. Finally, we find that the [O III ] luminosity (a proxy for SMBH accretion rate) in post-mergers that host an optical AGN is ~0.3 dex higher on average than in non-interacting galaxies with an optical AGN, suggesting that mergers generate higher accretion rates than secular triggering mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Utah FORGE: Neubrex Well 16B(78)-32 DAS Data - April, 2024

This dataset comprises Distributed Acoustic Sensing (DAS) data collected from the Utah FORGE monitoring well 16B(78)-32 (the producer well) during hydraulic fracture stimulation operations conducted in April 2024. The data were acquired continuously over the stimulation period at a temporal sampling rate of 10,000 Hz (10 kS/s) and a spatial resolution of approximately 3.35 feet (1.02109 meters). The measurements were captured using a Neubrex NBX-S4100 Time Gated Digital DAS interrogator unit connected to a single-mode fiber optic cable, which was permanently installed within the casing string. All recorded channels correspond to downhole segments of the fiber optic cable, from a measured depth (MD) of 5,369.35 feet to 10,352.11 feet. The DAS data reflect raw acoustic energy generated by physical processes within and surrounding the well during stimulation activities at wells 16A(78)-32 and 16B(78)-32. These data have potential applications in analyzing cross-well strain, far-field strain rates (including microseismic activity), induced seismicity, and seismic imaging. Metadata embedded in the attributes of the HDF5 files include detailed information on the measured depths of the channels, interrogation parameters, and other acquisition details. The dataset also includes a recording of a seminar held on September 19, 2024, where Neubrex's Chief Operating Officer presented insights into the data collection, analysis, and preliminary findings. The raw data files, stored in HDF5 format, are organized chronologically according to the recording intervals from April 9 to April 24, 2024, with each file corresponding to a 12-second recording interval.

15 GEOTHERMAL ENERGY↗

In situ Detection of Plasma Induced Surface Interaction based on Deep Learning based Visual Diagnostics (Technical Report)

It is characteristic for many plasma devices to undergo plasma-material interaction leading to surface erosion. These processes, often not easily detectable, lead to changes in device performance and lifespan. State-of-the-art lifetime tests and wear experiments require over 1000s hours. A self-consistent model for accurately predicting the erosion's effects is not available. In situ detection of these processes is not a trivial task since the surface variations at the early stages have a micron scale. Such limitations not only restrict testing and prediction capabilities but also slow the development of new thrusters and limit mission duration. To address these challenges, an in-situ diagnostic for real-time erosion assessment has been developed, aiming to expedite lifetime testing and broaden experimental campaigns. Several works were dedicated to real-time and in situ monitoring of material erosion during plasma exposure using laser holography, microscopy, and with telemicroscopes. However, the applicability of these approaches is limited due to complexity, cost and less flexibility as they often require placing diagnostic equipment inside the vacuum chamber. In collaboration with Princeton Collaborative Research Facility (PCRF), Princeton Plasma Physics Laboratory (PPPL), a new diagnostic approach is developed, where geometry modifications to the ceramic channel walls were introduced that would result in accelerated channel erosion. We employed Long-distance microscope (LDM) imagery, combined with Deep-Learning based Shape from focus or depth from focus (DFF or SFF) approach, that provides an accessible and cost-effective solution. LDM employs focus variation techniques to continuously capture multiple images of the target object at distinct focal planes. DFF, an optical focus variation method, generates a 3D topographical surface depth map from a sequence of variably focused images. Combined with the developed diagnostic, this approach offers a controllable means to study erosion under accelerated conditions. In this work, we develop Neural Network-based DFF algorithm applicable for LDM data to quantitatively evaluate plasma induced surface modification from LDM data. Next, we develop Deep Learning-based super-resolution depth map image reconstruction technique to increase the resolution of depth maps obtained from DFF algorithm to improve the accuracy of erosion measurements. Thirdly, we develop several image processing techniques to remove noise and improve the quality of depth map image. Here we report the results of initial tests for this approach. An experimental setup designed and built in PPPL was employed that consists of a 3-cm gridded ion source that produces a neutralized argon beam with energies up to 600 eV. A hexagonal boron nitride (h-BN) ceramic target, designed based on computational predictions, was used. Tests were conducted to reconstruct the complex geometry of the target under the lighting conditions of the operated ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hyperspectral Light Sheet Raman Imaging of Leaf Metabolism (Final Report)

This final technical report details the accomplishment and findings of a project that developed technology related to imaging metabolic processes in plants. The report gives technical details of the design, construction and characterization of a Raman microscope system capable of identifying chemical species using the wavelength shifts of scattered excitation light. Some of the unique aspects of the design include: use of a Bessel beam excitation source, which allow long excitation lines that are resistant to scattering in complex media such as plants; excitation at 785 nm to avoid fluorescence emission that can occur in photosynthetic organisms; and a flat optical design that makes construction and alignment significantly simpler. This project also used stable isotope labeling to look at photorespiratory flux in the leaves of three different types of plants that have different photosynthesis pathways. Gas chromatography–mass spectrometry was used to look at which metabolites and amino acids had altered oxygen, carbon and hydrogen uptake under various conditions of environmental oxygen. This generated a rich data set that is being further analyzed to understand metabolic pathways in plants. This project also used the natural fluorescence in sorghum and rice to conduct an extensive experiment across different developmental stages. Spectral differences were identified at most of the developmental stages and these can be attributed to differential pigment and pigment-protein complexes present in different relative abundances as the plant develops.

09 BIOMASS FUELS↗