Search NASA⌕ Search

SEARCH · Search NASA

Results for “Impact Mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Co-simulation Framework for Community-scale Building-grid Integration [SWR-21-75]

Distributed energy resources (DERs), including rooftop solar, energy storage, and flexible loads, are gaining popularity as costs decline and as building owners and utilities realize their benefits. DERs can improve distribution system efficiency, help prevent the need for expensive grid upgrades, and increase the resilience of local communities. However, they can also cause difficulties in grid operations and can require controls to achieve their benefits. To address this challenge, NREL researchers have developed a community-scale solution that assesses the impacts of DERs and their control strategies on a distribution system. The framework has been shown to reduce solar photovoltaic (PV) curtailment to 0%, mitigate the adverse impact of solar variability on the distribution voltage, and provide up to 5-day critical load support during emergency events. Utilizing 5 different modules representing the feeder, buildings, home energy management systems, an aggregator, and a utility controller, NREL expects this simulation technology to play a critical role in the continued integration of DERs. According to the Energy Information Administration (EIA), solar curtailments accounted for 94% of the total energy curtailed in the California Independent System Operator (CAISO) in 2020. By enabling Independent System Operators (ISOs) and utility operators to bring solar curtailments to 0%, the electrical grid can become less dependent on fossil-fueled power generation sources. NREL's co-simulation framework contains five major components: Distribution Feeder Model: describes the distribution feeder topology using OpenDSS, including the locations of all DERs. Residential Building Model: simulates a large number of buildings at a high resolution using OCHRETM. The model is equipped to control equipment based on signals from an external module. The model includes major household appliances such as HVAC and a water heater, non-dispatchable load models, a distributed PV system, and a home battery system. Home Energy Management System: optimizes the controls for the devices in a home using foreseeTM. The control can adjust based on the user preferences including cost, comfort, and convenience. In hierarchical control scenarios, where the houses follow signals from an aggregator, the home energy management system provides a flexibility band with a range of power and follows the dispatch signals received from aggregator. Community-Level Aggregator: solves for optimal energy dispatch based on the flexibility bands received from each home and the grid service signal received from the utility controller. Utility-Level Controller: provides grid signals for voltage control using Distributed Energy Resources (DERs), such as solar systems, in the community.

Balamurugan, Sivasathya Pradha↗

L-Basin Microbial Monitoring Program - Evaluation of 20 Years of Monitoring

The SRNL L-Basin corrosion surveillance and microbial monitoring programs provide early detection and characterization of corrosion attack to the fuel and storage system materials resulting from prolonged exposure to the L-Basin water environment and of changes to and impact of the diverse microbial population, respectively. The early detection of corrosion allows for adjustment of the water quality, engineering management, and fuel storage configurations to mitigate excessive corrosion attack. While microbial influenced corrosion in L-Basin has not been detected, tracking and understanding the effect of microbial populations on the stored fuel and basin water will aid in identifying remedial measures to mitigate any detrimental impact. This report reviews the microbial monitoring activities since initial characterizations in the mid-1990s.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tracking snowmelt during hydrological surface processes using a distributed hydrological model in a mesoscale basin on the Tibetan Plateau

We report that mountain snowpack is an important water resource for the high altitude and latitude regions where the terrain is complex. However, the snowmelt pathway and its actual contribution to streamflow and soil moisture are rarely reported and remain unclear in such regions. To fill in this knowledge gap, we incorporate a snowmelt pathway tracking algorithm to a high-resolution physics-based distributed-hydrology-soil-vegetation model (DHSVM), to track snowmelt movement and quantify snowmelt contributions in the surface hydrologic processes. A simple reservoir operation scheme is also incorporated in the model. The modified model is applied to a dammed meso-scale watershed in the northeast Tibetan Plateau, China to study the snow and reservoir effects. The results show that annual snow contribution to soil moisture (SC-SM) and snow contribution to streamflow (SC-S) significantly decrease over 1965-2019. At a monthly scale, SC-SM has the largest amplitude at the top soil layer and its peak in the deeper layer lags behind the upper layer, and mean monthly SC-S at all stations show bimodal distributions corresponding to snowfall season. Reservoir regulation has subtle impacts (≤2.0%) on SC-S. If the current climate change rate continues, monthly and annual streamflow at the outlet will decrease primarily due to snowpack reduction. To mitigate climate change impacts, better water resource management is needed in this watershed.

54 ENVIRONMENTAL SCIENCES↗

Strategies to mitigate urban heat: Effects on overheating and cloud formation

This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.

albedo changes↗

Impact of Thermal Barrier Coatings on Intake and Exhaust Valves in a Spark Ignition Engine

Spark ignition knock is highly sensitive to changes in intake air temperature. Hot surface temperatures due to ceramic thermal barrier coatings increase knock propensity by elevating the incoming air temperature, thus mitigating the positive impacts of low heat transfer losses by requiring spark retard to avoid knock. Low thermal inertia coatings (i.e. Temperature swing coatings) have been proposed as a means of reducing or eliminating the open cycle charge heating penalty of traditional TBCs through a combination of low thermal conductivity and low volumetric heat capacity materials. However, in order to achieve a meaningful gain in efficiency, a significant fraction of the combustion chamber must be coated. In this study, a coated piston and intake and exhaust valves with coated combustion faces, backsides, and stems are installed in a single-cylinder research engine to evaluate the effect of high coated fractions of the combustion chamber in a knock-sensitive architecture. Spark timing sweeps demonstrated a small, but notable increase in net thermal efficiency compared to the coated piston by itself. Here, a staged valve removal demonstrated that the coated intake valve prevents heat transfer to the incoming air, reducing knock propensity compared to the coated exhaust valve individually.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Elevated Forest Canopy Loss After Wildfires in Moist and Cool Forests in the Pacific Northwest

Wildfire frequency, intensity, and rate of spread are increasing across the Western U.S, resulting in more severe ecosystem impacts. Significant tree mortality can occur years after fire events, but this has received little attention compared to the immediate tree loss during a fire. We overlapped forest cover loss data with burn severity maps in the U.S. Pacific Northwest and quantified the total and delayed forest canopy loss after fires. We found that wildfires resulted in total canopy loss fraction (CLF) of 84%, 53%, and 22% within 3 years in areas burned at high, moderate, and low severity, respectively. The delayed canopy loss accounted for approximately 1/3, 1/2, and 2/3 of the total canopy loss for high, moderate, and low severity burns. Delayed canopy loss was greater in moist and cool areas than in dry and warm areas, likely because tree species in wetter environments were less adapted to survive when fires did occur. Across all forests, delayed CLF doubled as temperature increased from the climatological mean to a hot anomaly and tripled as vapor pressure deficit increased from a wet anomaly to a dry anomaly. Fire impacts on forest ecosystems are likely to intensify under future climate scenarios as wildfires expand into areas that historically experienced infrequent fires. The impacts can also be exacerbated by more frequent compound extreme events, such as droughts, heatwaves, and fires. These findings highlight the urgent need for targeted forest management strategies, particularly in mesic forests, to mitigate future fire impacts.

54 ENVIRONMENTAL SCIENCES↗

Efficient Hybrid Attack Graph Generation for Cyber-Physical System Resilience Experimentation (Final Project Report)

HAGEN project has developed theory, algorithms, and capabilities to assist cyber physical system modelers and operators to perform system and device-level vulnerability assessment, risk assessment, impact assessment, and mitigation planning. The project generates hybrid attack graphs for Cyber-Physical System (CPS) resilience experimentation at desired scale and speed. The project will produce composite attack datasets, algorithms, and demonstrable prototypical tools, and a library of high-impact attack sequences for a given CPS of interest. This report provided overall summary of research and development performed between FY22-24.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

Cyber-informed Engineering Microgrid Analysis Tool

The Cyber-Informed Engineering Microgrid Analysis Tool (CIEMAT) leverages the Department of Energy’s Cyber-Informed Engineering to prompt engineering designers and operators through an analysis of the critical functions to be supported by a microgrid installations, the criticality of those functions, the impacts of denial, disruption or misuse of those functions on the microgrid and dependent functions, and the mitigations which could best prevent impacts to those functions resulting from cyber attack. Through use of this tool, microgrid designers and operators can quickly identify appropriate engineering mitigations to limit impacts from cyber attack and functions where engineering and operational staff can prioritize and guide the application of cybersecurity protections to best support the resiliency of the system.

Wright, VirginiaL [Idaho National Laboratory (INL)↗

Joint inference of multiplicative and additive systematics in galaxy density fluctuations and clustering measurements

Galaxy clustering measurements are a key probe of the matter density field in the Universe. With the era of precision cosmology upon us, surveys rely on precise measurements of the clustering signal for meaningful cosmological analysis. However, the presence of systematic contaminants can bias the observed galaxy number density, and thereby bias the galaxy two-point statistics. As the statistical uncertainties get smaller, correcting for these systematic contaminants becomes increasingly important for unbiased cosmological analysis. We present and validate a new method for understanding and mitigating both additive and multiplicative systematics in galaxy clustering measurements (two-point function) by joint inference of contaminants in the galaxy overdensity field (one-point function) using a maximum-likelihood estimator (MLE). We test this methodology with Kilo-Degree Survey-like mock galaxy catalogues and synthetic systematic template maps. We estimate the cosmological impact of such mitigation by quantifying uncertainties and possible biases in the inferred relationship between the observed and the true galaxy clustering signal. Our method robustly corrects the clustering signal to the sub-percent level and reduces numerous additive and multiplicative systematics from 1.5σ to less than 0.1σ for the scenarios we tested. In addition, we provide an empirical approach to identifying the functional form (additive, multiplicative, or other) by which specific systematics contaminate the galaxy number density. Even though this approach is tested and geared towards systematics contaminating the galaxy number density, the methods can be extended to systematics mitigation for other two-point correlation measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Storage in Local Zoning Ordinances

Increasing policy support and declining prices for battery energy storage systems (BESS) are driving rapid growth in the installation of these systems in the United States and around the world. Because a BESS is modular in nature and has limited infrastructure requirements, it can be built in close proximity to existing uses, which creates the potential for conflict. As the use of BESS grows, local planning and zoning staff are increasingly being asked to determine where the systems can be built and how their impacts on surrounding uses can be mitigated. While a large-scale BESS offers significant electric grid and societal benefits, it can also pose safety, visual, auditory, and environmental impacts on the community in which it is located. While these are material impacts, current safety codes for energy storage systems and land use frameworks provide planners with the necessary tools and processes to mitigate those impacts and ensure that their communities safely receive the benefits of energy storage systems. This report provides an overview of BESS from a land use perspective and describes their implications for zoning and project permitting. It concludes with an analysis of current energy storage zoning standards adopted by local jurisdictions in the U.S. Its intent is to objectively inform land use decisions for energy storage projects by equipping planning officials with relevant information about these technologies and knowledge of what questions to ask during review processes, so that energy storage projects can move forward in ways that will benefit electric systems while not unduly affecting host communities.

25 ENERGY STORAGE↗

Unveiling the Role of Critical Impurities in Spent LiFePO 4 Cathodes for Scalable Direct Regeneration

Direct regeneration offers a promising alternative to recycling End-of-Life (EoL) batteries by restoring metal elements and preserving the material structure, yet scaling these technologies to handle practical cathode black mass (CBM) with impurities remains challenging. Here, this study investigates the evolution of impurities, including aluminum (Al), polyvinylidene difluoride (PVDF) binder, and residual carbon (C), during direct recycling of spent LiFePO 4 (LFP) cathodes and their impact on electrochemical performance. Using various ex situ and in situ analyses, it is shown that the formation of lithium fluoride (LiF) during the traditional direct recycling process hinders lithium diffusion and deteriorates the reversible capacity. To address this major challenge, the combination of pH-controlled hydrothermal purification and the two-step sintering process is proposed effectively to regenerate spent LFP cathodes, eliminating the negative effect of Al and fluorine (F) impurities while mitigating any potential impacts of carbon residuals. The regenerated LFP from spent CBM achieves superior performance, retaining 152.5 mAh g −1 at 0.1 C and 133 mAh g −1 at 1 C with 98.7% capacity retention after 200 cycles. This approach is further validated using three distinct waste feedstocks from battery modules, enhancing impurity management and scalability in direct recycling. These findings present a sustainable and economically viable solution for large-scale LFP regeneration.

25 ENERGY STORAGE↗

Grid Utility Asset Vulnerability Assessment (GUAVA) Software Tool

Increasing demand and changes in generation portfolios is pushing power grid to operate towards the limit. However, due to lack of analytical tools for understanding various scales of impact on grid, it is becoming more vulnerable to wide scale power outages and blackouts. A vulnerable grid operating at its limit can be easily disrupted by asset failures caused by devastating hurricanes which has been known to damage transmission and distribution lines along its track. In this direction, researchers have focused on determining these assets by conducting Monte Carlo simulations of hurricanes with uncertainties and collected a large set of simulation data. To determine the infrastructure updates necessary for mitigating wide scale impact of hurricanes on the grid, we propose a software tool named “Grid Utility Asset Vulnerability Analysis” (GUAVA) framework. GUAVA presents a novel data-driven probabilistic analytical approach to (1) post-process hurricane failure scenarios, (2) identify/rank assets that are most vulnerable and critical to failing and are associated with highest impact/risk, and (3) to inform system upgrade decisions & prioritization. Based on the observed results and employed data-driven methodology, it is expected GUAVA can be adapted to provide power system planners with a recommendation engine for making informed decisions to improve resilience of grid.

Mahapatra, Kaveri↗

Impact of drought on global food security by 2050

Drought is a major driver of crop production loss, threatening global food security as the population rises toward 9 billion by 2050. Using a process-based crop model within an Earth system model, we assess drought-related impacts on maize, soybean, rice, and wheat production at global and country levels. We then develop a food insecurity index combining drought impacts with socio-economic factors. Our results indicate that by 2050, globally averaged drought losses for combined maize, soybean, rice, and wheat production are <2%, though soybean losses reach 3.6%. Despite these small average changes at the global scale, 62 countries experience maximum production losses over 10%, and 24 countries over 20%. Our index identifies regions at greatest risk, including large parts of South America, Africa, Eastern Europe, and Southeast Asia. These results illustrate the need for drought adaptation to mitigate future drought impacts on crop production.

54 ENVIRONMENTAL SCIENCES↗

Economic viability of using thermal energy storage for flexible carbon capture on natural gas power plants

Fossil fuel-based power plants generate 80% of the electricity in the United States and provide a reliable generation source for both base and peak power demands. These plants are expected to adapt to changes in environmental policies that will require carbon management with carbon capture and storage (CCS) representing a possible solution. Current solvent-based CCS has a detrimental impact on a power plant's performance due to large heat loads required for carbon capture solvent regeneration. This parasitic load restricts the power plant's output and operation flexibility. Therefore, this study evaluates the feasibility of using thermal storage technologies for natural gas combined cycle (NGCC) power plants coupled with CCS to minimize the impact of solvent regeneration and enable the plant to operate at peak power output. Thermal storage can minimize the impact of CCS on the power plant by providing the heat load required for solvent regeneration during times of peak demand which will allow the plant to operate unrestricted and at full power. In total, fifteen unique thermal storage configurations were evaluated from three thermal storage categories: Brayton cycle heat pump, vapor compression heat pump, and heat recovery steam generator steam extraction for storage. The viability of these systems was determined by evaluating each configuration on thousands of real-world Locational Marginal Pricing (LMP) profiles from the New York Independent System Operator and California Independent System Operator electricity markets using a techno-economic analysis. Afterwards, results were compared to the performance of a base power plant (NGCC with CCS and no thermal storage) to determine the impact of thermal storage on power plant economics. Overall, six of the thermal storage configurations performed better than base CCS enabled power plant on between 11.5% and 38.7% of the LMP signals evaluated. The best performing configuration was a vapor compression heat pump that used flue gas as the working fluid and had both hot and cold thermal storage units. This configuration performed better than the base CCS power plant on 38.7% of the LMP profiles. The results of this study show thermal storage can mitigate the economic impact of carbon capture solvent regeneration on NGCC power plants. Discussion focuses on the impact of electricity pricing on the optimal thermal storage system, the advantages and disadvantages of the systems evaluated, and identifies limitations with the study.

25 ENERGY STORAGE↗

Nonlinear saturation of whistler modes driven by runaway electrons

Runaway electrons exhibit kinetic instabilities with potentially beneficial consequences. The anomalous Doppler resonance between the electrons and whistler modes is a primary underlying mechanism. These instabilities require a first-principle nonlinear theoretical analysis, which would ultimately enable assessment of their impact on disruption mitigation and diagnostics, especially in ITER-relevant conditions. This paper presents recent progress in developing the required theoretical framework for isolated nonlinear resonances. By employing the generic bump-on-tail model, we predict the wave saturation levels in both near-threshold and strongly driven regimes. Remarkably, for the waves of interest, the parallel component of the wave vector dictates the parallel momentum of the resonant particles. This feature, together with the expected wave saturation level, provides a complete description of the resonance impact on the runaway electron distribution function. We show that the parametric dependence of the nonlinearly saturated mode provides a way to recover certain features of the runaway momentum distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗