Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Gamma-ray burst localization by HEAO 3

The relative response of the five segments of the HEAO 3 gamma-ray-spectroscope anticoincidence shield (a 6.62-cm-thick 33.1-cm-OD 27.4-cm-high CsI cylinder) is used to estimate the directions of gamma-ray bursts on February 13, 1980 and September 29, 1979. The operation of the instrument and the data-analysis procedures are described, and the results are presented graphically. The 1980 event is located in an error box centered on alpha = 104.5 deg and delta = -15 deg (error box A of Atteia et al., 1987). The position of the 1979 event (alpha = 75 deg and delta = 40 deg) is shown to be consistent with ISEE 3 and Pioneer Venus Orbiter arrival times.

Schwartz, R. A.↗

Trace gas measurements from tethered balloon platforms

Instrumentation and chemical sampling and analysis procedures are described for making measurements of atmospheric carbon disulfide in the concentration range 1-1000 pptv from tethered balloon platforms. Results of a study on the CS2 composition of air downward of a saltwater marsh are reported. A method for obtaining the necessary data for solving the budget equations for surface fluxes, chemical formation rates and chemical destruction rates using data acquired from tethered balloon platforms is presented.

Bandy, Alan R.↗

The response of SAR imagery to azimuth travelling ocean surface waves as determined from shuttle SAR imagery

Comparisons between two-dimensional ocean wave spectra, derived from synthetic aperture radar (SAR) imagery, and two-dimensional wave spectra from independent instruments have shown good agreement. The procedure by which raw SAR image intensity-variance spectra are converted to estimates of wave spectra is dependent upon models of how a SAR is able to image ocean waves. The greatest uncertainty exists about the mechanism by which azimuth (along track) traveling waves are imaged. In this paper, independent wave spectra from an airborne, radar ocean wave spectrometer (ROWS) are systematically compared with spatially and temporally coincident shuttle SAR image intensity-variance spectra to determine an optimum description of the relationship between the two. The result of these comparisons is to demonstrate that a SAR image intensity-variance spectrum is nearly proportional to the ocean wave slope-variance spectrum for azimuth traveling waves.

Monaldo, Frank M.↗

Joint NASA/USAF Airborne Field Mill Program - Operation and safety considerations during flights of a Lear 28 airplane in adverse weather

A NASA Langley Research Center Learjet 28 research airplane was flown in various adverse weather conditions in the vicinity of the NASA Kennedy Space Center from 1990-1992 to measure airborne electric fields during the Joint NASA/USAF Airborne Field Mill Program. The objective of this program was to characterize the electrical activity in various weather phenomena common to the NASA-Kennedy area in order to refine Launch Commit Criteria for natural and triggered lightning. The purpose of the program was to safely relax the existing launch commit criteria, thereby increasing launch availability and reducing the chance for weather holds and delays. This paper discusses the operational conduct of the flight test, including environmental/safety considerations, aircraft instrumentation and modification, test limitations, flight procedures, and the procedures and responsibilities of the personnel in the ground station. Airborne field mill data were collected for all the Launch Commit Criteria during two summer and two winter deployments. These data are now being analyzed.

Fisher, Bruce D.↗

Aircraft rate-of-climb indicators

The theory of the rate-of-climb indicator is developed in a form adapted for application to the instrument in its present-day form. Compensations for altitude, temperature, and rate of change of temperature are discussed from the designer's standpoint on the basis of this theory. Certain dynamic effects, including instrument lag, and the use of the rate-of-climb indicator as a statoscope are also considered. Modern instruments are described. A laboratory test procedure is outlined and test results are given.

Johnson, Daniel P↗

Parallel runway requirement analysis study. Volume 2: Simulation manual

This document is a user manual for operating the PLAND_BLUNDER (PLB) simulation program. This simulation is based on two aircraft approaching parallel runways independently and using parallel Instrument Landing System (ILS) equipment during Instrument Meteorological Conditions (IMC). If an aircraft should deviate from its assigned localizer course toward the opposite runway, this constitutes a blunder which could endanger the aircraft on the adjacent path. The worst case scenario would be if the blundering aircraft were unable to recover and continue toward the adjacent runway. PLAND_BLUNDER is a Monte Carlo-type simulation which employs the events and aircraft positioning during such a blunder situation. The model simulates two aircraft performing parallel ILS approaches using Instrument Flight Rules (IFR) or visual procedures. PLB uses a simple movement model and control law in three dimensions (X, Y, Z). The parameters of the simulation inputs and outputs are defined in this document along with a sample of the statistical analysis. This document is the second volume of a two volume set. Volume 1 is a description of the application of the PLB to the analysis of close parallel runway operations.

Ebrahimi, Yaghoob S.↗

A new measurement of the flux of the light cosmic-ray nuclei at high energies

A new cosmic-ray detector utilizing a ring-imaging Cerenkov counter to determine the energy of light cosmic-ray nuclei was flown on high-altitude balloon from Fort Sumner, NM, in 1991 September. We describe the design and performance of this instrument and discuss the data analysis procedures. The measurement provides a new determination of the absolute flux and differential energy spectrum of the primary cosmic-ray species helium between 40 and 320 GeV/nucleon. The experiment also yields the spectra of carbon and oxygen and some information on the intensities of the secondary nuclei Li, Be, and B. A comparison between our results and previous measurements of heavier nuclei (Z greater than or equal to 4) from HEAO 3 and Spacelab 2 indicates good consistency between these measurements. The data set is compared with the results of a leaky box propagation model. We find good agreement with this model if the abundance of helium relative to oxygen at the source is taken to be 25 +/- 6 and if the source spectrum is given by a power law in energy proportional to E(exp -2.15).

Buckley, J.↗

Smithsonian stratospheric far-infrared spectrometer and data reduction system

The Smithsonian far-infrared spectrometer (FIRS) is a remote sensing Fourier transform spectrometer that measures the mid- and far-infrared thermal emission spectrum of the stratosphere from balloon and aircraft platforms. The spectrometer has had nine successful balloon flights from 1987 to 1994, flying at float altitudes of 36 - 39 km and collecting 131 hours of midlatitude stratospheric limb spectra. The spectrometer also flew on a NASA CD-8 aircraft, as part of the second Airborne Arctic Stratospheric Expedition (AASE-2), collecting 140 hours of overhead spectra at latitudes ranging from the equator to the north pole. We present here a brief description of the instrument, a discussion of data reduction procedures, an estimation of both random and systematic errors, an outline of the procedure for retrieving mixing ratio profiles, and an explanation of the method of deriving temperature and pressure from the far- and mid-infrared spectra.

Johnson, D. G.↗

Calibration of NASA Turbulent Air Motion Measurement System

A turbulent air motion measurement system (TAMMS) was integrated onboard the Lockheed 188 Electra airplane (designated NASA 429) based at the Wallops Flight Facility in support of the NASA role in global tropospheric research. The system provides air motion and turbulence measurements from an airborne platform which is capable of sampling tropospheric and planetary boundary-layer conditions. TAMMS consists of a gust probe with free-rotating vanes mounted on a 3.7-m epoxy-graphite composite nose boom, a high-resolution inertial navigation system (INS), and data acquisition system. A variation of the tower flyby method augmented with radar tracking was implemented for the calibration of static pressure position error and air temperature probe. Additional flight calibration maneuvers were performed remote from the tower in homogeneous atmospheric conditions. System hardware and instrumentation are described and the calibration procedures discussed. Calibration and flight results are presented to illustrate the overall ability of the system to determine the three-component ambient wind fields during straight and level flight conditions.

Barrick, John D. W.↗

Human Factors Process Task Analysis Liquid Oxygen Pump Acceptance Test Procedure for the Advanced Technology Development Center

A process task analysis effort was undertaken by Dynacs Inc. commencing in June 2002 under contract from NASA YA-D6. Funding was provided through NASA's Ames Research Center (ARC), Code M/HQ, and Industrial Engineering and Safety (IES). The John F. Kennedy Space Center (KSC) Engineering Development Contract (EDC) Task Order was 5SMA768. The scope of the effort was to conduct a Human Factors Process Failure Modes and Effects Analysis (HF PFMEA) of a hazardous activity and provide recommendations to eliminate or reduce the effects of errors caused by human factors. The Liquid Oxygen (LOX) Pump Acceptance Test Procedure (ATP) was selected for this analysis. The HF PFMEA table (see appendix A) provides an analysis of six major categories evaluated for this study. These categories include Personnel Certification, Test Procedure Format, Test Procedure Safety Controls, Test Article Data, Instrumentation, and Voice Communication. For each specific requirement listed in appendix A, the following topics were addressed: Requirement, Potential Human Error, Performance-Shaping Factors, Potential Effects of the Error, Barriers and Controls, Risk Priority Numbers, and Recommended Actions. This report summarizes findings and gives recommendations as determined by the data contained in appendix A. It also includes a discussion of technology barriers and challenges to performing task analyses, as well as lessons learned. The HF PFMEA table in appendix A recommends the use of accepted and required safety criteria in order to reduce the risk of human error. The items with the highest risk priority numbers should receive the greatest amount of consideration. Implementation of the recommendations will result in a safer operation for all personnel.

Diorio, Kimberly A.↗

Utilization of the NASA Robonaut as a Surgical Avatar in Telemedicine

The concept of teleoperated robotic surgery is not new; however, most of the work to date has utilized specialized robots designed for specific set of surgeries. This activity explores the use of a humanoid robot to perform surgical procedures using the same hand held instruments that a human surgeon employs. For this effort, the tele-operated Robonaut (R2) was selected due to its dexterity, its ability to perform a wide range of tasks, and its adaptability to changing environments. To evaluate this concept, a series of challenges was designed with the goal of assessing the feasibility of utilizing Robonaut as a telemedicine based surgical avatar.

Dean, Marc↗

A New Method to Correct the Electrochemical Concentration Cell (ECC) Ozonesonde Time Response and its Implications for "Background Current" and Pump Efficiency

The electrochemical concentration cell (ECC) ozonesonde has been the main instrument for in situ profiling of ozone worldwide; yet, some details of its operation, which contribute to the ozone uncertainty budget, are not well understood. Here, we investigate the time response of the chemical reactions inside the ECC and how corrections can be used to remove some systematic biases. The analysis is based on the understanding that two reaction pathways involving ozone occur inside the ECC that generate electrical currents on two very different timescales. The main fast-reaction pathway with a time constant of about 20 s is due the conversion of iodide to molecular iodine and the generation of two free electrons per ozone molecule. A secondary slow-reaction pathway involving the buffer generates an excess current of about 2 %–10 % with a time constant of about 25 min. This excess current can be interpreted as what has conventionally been considered the “background current”. This contribution can be calculated and removed from the measured current instead of the background current. Here we provide an algorithm to calculate and remove the contribution of the slow-reaction pathway and to correct for the time lag of the fast-reaction pathway. This processing algorithm has been applied to ozonesonde profiles at Costa Rica and during the Central Equatorial Pacific Experiment (CEPEX) as well as to laboratory experiments evaluating the performance of ECC ozonesondes. At Costa Rica, where a 1 % KI, 1/10th buffer solution is used, there is no change in the derived total ozone column; however, in the upper troposphere and lower stratosphere, average reported ozone concentrations increase by up to 7 % and above 30 km decrease by up to 7 %. During CEPEX, where a 1 % KI, full-buffer solution was used, ozone concentrations are increased mostly in the upper troposphere, with no change near the top of the profile. In the laboratory measurements, the processing algorithms have been applied to measurements using the majority of current sensing solutions and using only the stronger pump efficiency correction reported by Johnson et al. (2002). This improves the accuracy of the ECC sonde ozone profiles, especially for low ozone concentrations or large ozone gradients and removes systematic biases relative to the reference instruments. In the surface layer, operational procedures prior to launch, in particular the use of filters, influence how typical gradients above the surface are detected. The correction algorithm may report gradients that are steeper than originally reported, but their uncertainty is strongly influenced by the prelaunch procedures.

electrochemical concentration cell (ECC) ozonesond↗

Improving “Domain-Relevant Metadata Requirements” for Supporting Open-Source Science Initiative

Implementation of the NASA Open-Source Science Initiative (OSSI) requires sharing of all relevant information to ensure “open reproducible science” [1]. However, there are several challenges in applying the OSSI to airborne field campaigns focused on atmospheric composition, which often involve a wide variety of in-situ measurements for trace gases, aerosol and cloud properties, meteorological parameters, and radiation fields. To ensure open reproducibility from airborne field campaigns, it is essential to obtain detailed measurement descriptions, which include the detection principle, sample procedure and treatment, and data processing and correction method. The challenge is that some information, e.g., sampling procedure and treatment, may be instrument-specific and campaign or platform-dependent. The data processing may also involve empirical corrections which may evolve over time. In addition, these details (especially operation- or campaign-specific ones) are often not given in journal publications. Given these issues, there is a need to leverage and improve the current “domain-relevant metadata requirements” to represent the measurement description in standardized metadata. These requirements can then facilitate systematic collection of measurement specific metadata and serve as a foundation to develop tools for making the information accessible and data more interoperable and usable or reusable. Here we show a review of existing metadata collections, use cases, and needs for new standards.

Sean Leavor↗

Determination of transfer function of COPE correlation interferometer instrument

The comparison of theoretical and instrument response functions and its use as a procedure for determining the transfer function of the COPE correlation interferometer are summarized. Data show qualitative agreement can be obtained when discrepancies between theory and instrument are investigated and instrument components are analyzed in detail. Data were obtained using a set of calibration data and computer algorithms.

Twitty, J.↗

Refinement of planetary protection policy for Mars missions

Under existing COSPAR policy adopted in 1984, missions to Mars (landers, probes, and some orbiters) are designated as Category IV missions. As such, the procedures for implementing planetary protection requirements could include trajectory biasing, cleanrooms, bioload reduction, sterilization of hardware, and bioshields. In 1992, a U.S. National Research Council study recommended that controls on forward contamination of Mars be tied to specific mission objectives. The report recommended that Mars landers with life detection instruments be subject to at least Viking-level sterilization procedures for bioload reduction, while spacecraft (including orbiters) without life detection instruments be subject to at least Viking-level pre-sterilization procedures for bioload reduction but need not be sterilized. In light of this, it is proposed that the current policy's Category IV and its planetary protection requirements be divided into two sub-categories as follows: Category IVa, for missions comprising landers and probes without life detection experiments, which will meet a specified bioburden limit for exposed surfaces, and Category IVb, for landers and probes with life detection experiments, which will require sterilization of landed systems. In addition, Category III orbiter mission specifications are expanded to be consistent with these recommendations.

NASA Discipline Exobiology↗

Revision to Planetary Protection Policy for Mars Missions

Under existing COSPAR policy adopted in 1984, missions to Mars (landers, probes, and some orbiters) are designated as Category IV missions. As such, the procedures for implementing planetary protection requirements could include trajectory biasing, cleanrooms, bioload reduction, sterilization of hardware, and bioshields, i. e. requirements could be similar to Viking. However, in 1992, a U. S. National Academy of Sciences study recommended that controls on forward contamination of Mars be tied to specific mission objectives. The report recommended that Mars landers with life detection instruments be subject to at least Viking-level sterilization procedures for bioload reduction, while spacecraft (including orbiters) without life detection instruments be subject to at least Viking-level pre sterilization procedures for bioload reduction but need not be sterilized. In light of this, it is proposed that the current policy's Category IV missions and their planetary protection requirements be divided into two subcategories as follows: Category IV A, for missions comprising landers and probes without life detection experiments and some orbiters, which will meet a specified bioburden limit for exposed surfaces; Category IV B, for landers and probes with life detection experiments, which will require complete system sterilization. For Category IV A missions, bioburden specifications will be proposed and implementing procedures discussed. A resolution will be proposed to modify the existing COSPAR policy to reflect these changes. Similar specifications, procedures, and resolution for Category IV B missions will be the subject of a later study.

DeVincenzi, D. L.↗

Measurement of the Coolant Channel Temperatures and Pressures of a Cooled Radial-Inflow Turbine

Instrumentation has been installed on the surface of a cooled radial-inflow turbine. Thermocouples and miniature integrated sensor pressure transducers were installed to measure steady state coolant temperatures, blade wall temperatures, and coolant pressures. These measurements will eventually be used to determine the heat transfer characteristics of the rotor. This paper will describe the procedures used to install and calibrate the instrumentation and the testing methods followed. A limited amount of data will compare the measured values to the predicted values.

Dicicco, L. Danielle↗