Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Very high resolution radiometer /VHRR/

Discussion of the design and performance of the very high resolution radiometer (VHRR) representing the first of a second-generation of infrared scanning radiometers of high performance. Following a description of the optical, signal-electronics, sync-generator, scan-drive, cooler, and contamination-protection design, it is pointed out that the two VHRRs presently operating have logged a total of 15,500 hrs of continuous successful operation since launch. The cooler operation has been particularly noteworthy. The cold plate heater power, required to maintain the detectors at 105 K, has undergone in almost a year's operation so small a degradation as to indicate a VHRR cooler lifetime exceeding the instrument design lifetime of one year by a large margin. High resolution, low noise, and jitter-free pictures are shown to have been derived from these instruments.

Aronson, A. I.↗

Study and simulation results for video landmark acquisition and tracking technology (Vilat-2)

The results of several investigations and hardware developments which supported new technology for Earth feature recognition and classification are described. Data analysis techniques and procedures were developed for processing the Feature Identification and Location Experiment (FILE) data. This experiment was flown in November 1981, on the second Shuttle flight and a second instrument, designed for aircraft flights, was flown over the United States in 1981. Ground tests were performed to provide the basis for designing a more advanced version (four spectral bands) of the FILE which would be capable of classifying clouds and snow (and possibly ice) as distinct features, in addition to the features classified in the Shuttle experiment (two spectral bands). The Shuttle instrument classifies water, bare land, vegetation, and clouds/snow/ice (grouped).

Lowrie, J. W.↗

Far-IR Fabry-Perot spectrometer for OH measurements

The Far Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure chemical species in the upper atmosphere using limb emission in the far infrared region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain a resolution of 0.0017/cm near 101/cm (99 microns). The instrumental concept and atmospheric measurements are discussed.

Pickett, H. M.↗

An Overview of the Mid-Infrared Spectro-Interferometer MATISSE: Science, Concept, and Current Status

MATISSE is the second-generation mid-infrared spectrograph and imager for the Very Large Telescope Interferometer (VLTI) at Paranal. This new interferometric instrument will allow significant advances by opening new avenues in various fundamental research fields: studying the planet-forming region of disks around young stellar objects, understanding the surface structures and mass loss phenomena affecting evolved stars, and probing the environments of black holes in active galactic nuclei. As a first breakthrough, MATISSE will enlarge the spectral domain of current optical interferometers by offering the L and M bands in addition to the N band. This will open a wide wavelength domain, ranging from 2.8 to 13 microns, exploring angular scales as small as 3 mas (L band) 10 mas (N band). As a second breakthrough, MATISSE will allow mid-infrared imaging - closure-phase aperture-synthesis imaging - with up to four Unit Telescopes (UT) or Auxiliary Telescopes (AT) of the VLTI. Moreover, MATISSE will offer a spectral resolution range from R approx. 30 to R approx. 5000. Here, we present one of the main science objectives, the study of protoplanetary disks, that has driven the instrument design and motivated several VLTI upgrades (GRA4MAT and NAOMI). We introduce the physical concept of MATISSE including a description of the signal on the detectors and an evaluation of the expected performances. We also discuss the current status of the MATISSE instrument, which is entering its testing phase, and the foreseen schedule for the next two years that will lead to the first light at Paranal.

interferometric instrument↗

Thermal Performance Comparison and Lessons Learned for the Thermal Infrared Sensor Instruments 1 & 2

The Thermal Infrared Sensor (TIRS-1) is one of two instruments on the Landsat-8 Mission, which launched in February of 2013 and remains operational. The TIRS-2 instrument was developed for the Landsat-9 Mission, which is scheduled to launch in September of 2021. The TIRS-2 instrument design was adjusted to account for requirements changes and to include key lessons learned from its predecessor. The overall thermal subsystem design of the TIRS Sensor Unit remained comparable from mission to mission, but there were some areas that needed modifications. The general design is comprised of five thermal zones which range in temperature from less than 43 Kelvin to 320 Kelvin. Most zones are proportional heater controlled. A two-stage cryocooler provided by Ball Aerospace is used to cool the cryogenic subsystem, and excess power dissipation is rejected via ammonia transport heat pipes to a dedicated cryocooler radiator with embedded ammonia heat pipes. The cryogenic subsystem includes a series of shells used to radiatively and conductively isolate the cold stage from the warmer surroundings. The Optical System (telescope) is passively cooled to 180-195 Kelvin using a dedicated radiator with embedded dual-bore ethane heat pipes. The warmer end of the instrument includes a Scene Select Mechanism, an on-board Black Body Calibrator with a dedicated radiator, and a Focal Plane Electronics Box, all of which are attached to the Sensor Unit primary structure. The TIRS-1 thermal subsystem design was successfully verified during an extended testing campaign and during more than 8years of on-orbit operations. The TIRS-2 thermal subsystem design was successfully verified during months of ground testing prior to delivery in August of 2019and at the Observatory level in the Spring of 2021. A detailed comparison of the thermal performance of the two instruments has been made with a focus on key lessons learned during each instrument development, and with the benefit of on-orbit data acquired for the TIRS-1 instrument.

Veronica Otero↗

Stratospheric OH measurements with a far-infrared limb observing spectrometer

The Far-Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure the hydroxyl radical (OH) and other chemical species in the upper atmosphere using limb emission in the far-infrared region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain high spectral resolution near 101/cm and 118/cm. The instrument concept, calibration, and atmospheric measurements are discussed.

Pickett, H. M.↗

Lunar Scout Infrared Detector (LSIRD): Simple low-cost imaging spectrometer

A novel design for a compact, light weight, imaging spectrometer has been proposed for an orbiting Lunar mapping mission. Simple in design, its dual arm optical system employs a transmission grating and a dichroic mirror to provide continous two-octave spectral response. The grating's first order wavelengths are reflected into the SWIR arm, while the second order wavelenghts are transmitted to the VNIR arm. The instrument design is that of a push broom camera. It uses one of the detector(s) dimensions for spectral selection, the other detector(s) dimension for cross-track spatial selection, and the foward motion of the platform (in this case, a spececraft) for down-track spatial coverage.

Lunar↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power (R ~ 100) and a large bandwidth (~ 400 nm – ~ 1.8 µm). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors – fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

The Deflection Plate Analyzer: A Technique for Space Plasma Measurements Under Highly Disturbed Conditions

A technique has been developed to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The present method is an extension of the capabilities of the Differential Ion Flux Probe (DIFP) to include a mass measurement that does not include either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This reduces the complexity and expense of instrument fabrication, testing, and integration of flight hardware as compared to classical mass analyzers. The new instrument design is called the Deflection Plate Analyzer (DPA) and can deconvolve multiple ion streams and analyze each stream for ion flux intensity (density), velocity (including direction of motion), mass, and temperature (or energy distribution). The basic functionality of the DPA is discussed. The performance characteristics of a flight instrument as built for an electrodynamic tether mission, the Propulsive Small Expendable Deployer System (ProSEDS), and the instrument s role in measuring key experimental conditions are also discussed.

Wright, Kenneth H., Jr.↗

The Deflection Plate Analyzer: A Technique for Space Plasma Measurements Under Highly Disturbed Conditions

A technique has been developed to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The present method is an extension of the capabilities of the Differential Ion Flux Probe (DIFP) to include a mass measurement that does not include either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This reduces the complexity and expense of instrument fabrication, testing, and integration of flight hardware as compared to classical mass analyzers. The new instrument design is called the Deflection Plate Analyzer (DPA) and can deconvolve multiple ion streams and analyze each stream for ion flux intensity (density), velocity (including direction of motion), mass, and temperature (or energy distribution). The basic functionality of the DPA is discussed. The performance characteristics of a flight instrument as built for an electrodynamic tether mission, the Propulsive Small Expendable Deployer System (ProSEDS), and the instrument s role in measuring key experimental conditions are also discussed.

Wright, Kenneth H., Jr.↗

The Primordial Inflation Polarization Explorer (PIPER)

The Primordial Inflation Polarization Explorer (PIPER) is a ba1loon-borne instrument designed to search for the faint signature of inflation in the polarized component of the cosmic microwave background (CMB). PIPER will measure the CMB polarization at 4 frequencies (l per flight) using a pair of cryogenic telescopes, one for measuring each of Stokes Q and U in the instrument frame. Each telescope receives both linear orthogonal polarizations in two 32 by 40 element planar arrays that utilize Transition-Edge Sensors (TES). The first element in each telescope is a variable-delay polarization modulator (VPM) that fully modulates the Stokes parameter to which the telescope is sensitive.

Chuss, David T.↗

A low energy electron magnetometer

The concept of a highly sensitive magnetometer based on the deflection of low energy electron beams in magnetic fields is analyzed. Because of its extremely low mass and consequently high e/m ratio, a low energy electron is easily deflected in a magnetic field, thus providing a basis for very low field measurement. Calculations for a specific instrument design indicate that a low energy electron magnetometer (LEEM) can measure magnetic fields as low as 1000 nT. The anticipated performance of LEEM is compared with that of the existing high resolution magnetometers in selected applications. The fast response time of LEEM makes it especially attractive as a potential instrument for magnetic signature analysis in large engineering systems.

Singh, J. J.↗

(abstract) Galileo PPR Observations of Shoemaker-Levy 9

The Galileo spacecraft Photopolarimeter Radiometer (PPR), a hybrid visual/thermal IR instrument designed primarily to measure properties of the Jovian atmosphere, was employed for SL9 as a staring high-speed photometer at 945 and 678 nm, taking advantage of Galileo's direct view of the impact point.The PPR was able to acquire data at times when no other Galileo optical instruments could operate.

Galileo Jupiter Shoemaker-Levy 9 IR observations p↗

Polar Mesospheric Clouds (PMCs) Observed by the Ozone Monitoring Instrument (OMI) on Aura

Backscattered ultraviolet (BUV) instruments designed for measuring stratospheric ozone profiles have proven to be robust tools for observing polar mesospheric clouds (PMCs). These measurements are available for more than 30 years, and have been used to demonstrate the existence of long-term variations in PMC occurrence frequency and brightness. The Ozone Monitoring Instrument (OMI) on the EOS Aura satellite provides new and improved capabilities for PMC characterization. OMI uses smaller pixels than previous BUV instruments, which increases its ability to identify PMCs and discern more spatial structure, and its wide cross-track viewing swath provides full polar coverage up to 90 latitude every day in both hemispheres. This cross-track coverage allows the evolution of PMC regions to be followed over several consecutive orbits. Localized PMC variations determined from OMI measurements are consistent with coincident SBUV/2 measurements. Nine seasons of PMC observations from OMI are now available, and clearly demonstrate the advantages of these measurements for PMC analysis.

DeLand, Matthew T.↗

Acousto-optic infrared spectral imager for Pluto fast flyby

Acousto-optic tunable filters (AOTF's) enable the design of compact, two-dimensional imaging spectrometers with high spectral and spatial resolution and with no moving parts. Tellurium dioxide AOTF's operate from about 400 nm to nearly 5 microns, and a single device will tune continuously over one octave by changing the RF acoustic frequency applied to the device. An infrared (1.2-2.5 micron) Acousto-Optic Imaging Spectrometer (AImS) was designed that closely conforms to the surface composition mapping objectives of the Pluto Fast Flyby. It features a 75-cm focal length telescope, infrared AOTF, and 256 x 256 NICMOS-3 focal plane array for acquiring narrowband images with a spectral resolving power (lambda/delta(lambda)) exceeding 250. We summarize the instrument design features and its expected performance at the Pluto-Charon encounter.

Glenar, D. A.↗

Stellar and solar X-ray polarimetry

Astronomical stellar and solar studies involving X-ray polarimetry are discussed along with the statistical limitations inherent in polarimeter measurements and the design principles of a number of polarimeter types. Attention is given to photoelectric polarimeters, secondary fluorescence X-ray polarimeters, Borrmann-effect polarimeters, circular polarization analyzers, gamma-ray polarimeters, and multilayer reflection polarimeters. Bragg crystal polarimeters are considered, taking into account the theory of the polarimeter operation, aspects of instrument design, and the occurrence of systematic errors. The design and the performance of a rocket and a satellite Thomson-scattering polarimeter are also examined.

Novick, R.↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power ($R \sim 100$) and a large bandwidth ($\sim 400$ nm -- $\sim 1.8$ $\mu$m). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors -- fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Background suppression techniques in germanium detectors

A new generation of astrophysical gamma ray spectrometers employing germanium solid state detectors for precise energy measurement are currently being planned for spaceflight in the late 1990's and the early 21st century. Because the observations of weak celestial sources are carried out in an intense radiation environment, the key objective of instrument design is to find ways to reduce the background. The current state of the knowledge in this field is reviewed and the new hardware techniques under design and test are discussed. Many of these techniques have already been flight tested on balloon platforms. Recent results from some of these tests are presented. By carefully applying these techniques it should be possible to achieve sensitivities that are factors of 3 to 10 better than would be obtained for a conventional instrument of similar weight.

Gehrels, Neil↗