Search NASA⌕ Search

SEARCH · Search NASA

Results for “Iodine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A thermodynamic model of the Hg(0.8)Cd(0.2)Te-iodine transport system. I - Te-saturated source material. II - Source material composition within the homogeneity range

A thermochemical analysis of the Hg(0.8)Cd(0.2)Te-iodine vapor transport system is presented, and theoretical calculations of diffusion-controlled mass transport rates are made. The predicted mass fluxes are compared with experimental data obtained from transport experiments under vertical, stabilizing conditions reported earlier and with results of additional transport experiments conducted during the present study. Experimental mass transport rate studies of the transport system for fixed amount of excess Hg as a function of transport agent pressure are presented. The mass fluxes are determined for the vertical, stabilizing orientation of the density gradient relative to the gravitational vector. In order to compare experimental mass transport rates with computed values, the thermochemical analysis is extended to take the formation of Hg vacancies in the above compound into account along with their effect on the partial pressure of the system.

Chandra, D.↗

Perfluorobutyl iodides as gain media for a solar-pumped iodine laser amplifier

The effectiveness of t-C4F9I and n-C4F9I as gain media for a space-based solar-pumped iodine photodissociation laser is investigated experimentally. The optically coupled flashlamp/amplifier-tube apparatus described by Hwang et al. (1986) is employed, driving the amplifier with 4-microsec 4.2-mJ TEM(00) pulses from a flashlamp-pumped laser oscillator; the variation of amplification with energy-extraction time was monitored by inserting a delay of up to 1 msec between the firing of the two flashlamps and measuring the delay between the optical pulses. The results are presented graphically and briefly characterized. The performance of t-C4F9I is found to be better than that of n-C4F9I (or n-C3F7I), with an absorption band shifted toward the visible (for improved utilization of solar radiation), higher gain (by a factor of 2) at all delay times, and better chemical reversibility. The gain did not depend significantly on temperature in any of the iodides.

Tabibi, Bagher M.↗

High power CW iodine laser pumped by solar simulator

An iodine photodissociation laser was pumped by a long Ar arc as the solar simulator to produce a 10-W CW output. Continuous lasing for 1 h was achieved with a flow of the laser material n-C3F7I. The 10-W CW output is the highest produced to date and establishes the feasibility of developing a solar-pumped laser for space power transmission.

Lee, Ja H.↗

Quantitative characterization of a nonreacting, supersonic combustor flowfield using unified, laser-induced iodine fluorescence

A calibrated, nonintrusive optical technique, laser-induced iodine fluorescence (LIIF) was used to quantify the steady, compressible flowfield of a nonreacting, supersonic combustor. The combustor was configured with single and staged, transverse-air injection into a supersonic-air freestream behind a rearward-facing step. Pressure, temperature, two-velocity components, and injectant mole fraction were measured with high spatial resolution in the three-dimensional flowfields. These experimental results provide a benchmark set of data for validation of computational fluid dynamic (CFD) codes being developed to model supersonic combustor flowfields.

Fletcher, D. G.↗

Planar measurement of flow field parameters in a nonreacting supersonic combustor using laser-induced iodine fluorescence

A nonintrusive optical technique, laser-induced iodine fluorescence, has been used to obtain planar measurements of flow field parameters in the supersonic mixing flow field of a nonreacting supersonic combustor. The combustor design used in this work was configured with staged transverse sonic injection behind a rearward-facing step into a Mach 2.07 free stream. A set of spatially resolved measurements of temperature and injectant mole fraction has been generated. These measurements provide an extensive and accurate experimental data set required for the validation of computational fluid dynamic codes developed for the calculation of highly three-dimensional combustor flow fields.

Hartfield, Roy J., Jr.↗

Experimental investigation of a supersonic swept ramp injector using laser-induced iodine fluorescence

Planar measurements of injectant mole fraction and temperature have been conducted in a nonreacting supersonic combustor configured with underexpanded injection in the base of a swept ramp. The temperature measurements were conducted with a Mach 2 test section inlet in streamwise planes perpendicular to the test section wall on which the ramp was mounted. Injection concentration measurements, conducted in cross flow planes with both Mach 2 and Mach 2.9 free stream conditions, dramatically illustrate the domination of the mixing process by streamwise vorticity generated by the ramp. These measurements, conducted using a nonintrusive optical technique (laser-induced iodine fluorescence), provide an accurate and extensive experimental data base for the validation of computation fluid dynamic codes for the calculation of highly three-dimensional supersonic combustor flow fields.

Hartfield, Roy J.↗

Are there interactions of iodine and sulfur species in marine air photochemistry?

The effects of dimethyl sulfide (DMS) and methyl iodide (MI) emissions are analyzed using a two-dimensional photochemical model of a marine tropical tropospheric synoptic system. The model traces the atmospheric transformation cycles of the emissions to aerosols. The study is focused on remote tropical ocean regions and includes simulations of the spatial and diurnal variations of various iodine and sulfur species, and the species OH, HO2, and H2O2. One line of analysis leads to the conclusion that the reaction IO + DMS yields DMSO + I may play a significant role in destroying DMS if it proceeds at the published fast rate. Alternative lines of analyses are presented.

Chatfield, Robert B.↗

Viscosity of high-temperature iodine

The viscosity coefficient of iodine in the temperature range 500 - 3000 K is calculated. Because of the low dissociation energy of the I2 molecules, the dissociation degree of the gas increases quickly with temperature, and I + I2 and I + I collisions must be taken into account in calculation of viscosity at temperatures greater than 1000 deg. Several possible channels for atom-atom interaction are considered, and the resulting collision integrals are averaged over all the important channels. It is also shown that the rigid-sphere model is inaccurate in predictions of the viscosity.

Kang, Steve H.↗

A unified planar measurement technique for compressible flows using laser-induced iodine fluorescence

A unified laser-induced fluorescence technique for conducting planar measurements of temperature, pressure and velocity in nonreacting, highly compressible flows has been developed, validated and demonstrated. Planar fluorescence from iodine, seeded into air, was induced by an argon-ion laser and collected using a liquid-nitrogen cooled CCD camera. In the measurement technique, temperature is determined from the fluorescence induced with the laser operated broad band. Pressure and velocity are determined from the shape and position of the fluorescence excitation spectrum which is measured with the laser operated narrow band. The measurement approach described herein provides a means of obtaining accurate, spatially-complete maps of the primary flow field parameters in a wide variety of cold supersonic and transonic flows.

Hartfield, Roy J., Jr.↗

Real-time quality assurance testing using photonic techniques: Application to iodine water system

A feasibility study of the use of inspection systems incorporating photonic sensors and multivariate analyses to provide an instrumentation system that in real-time assures quality and that the system in control has been conducted. A system is in control when the near future of the product quality is predictable. Off-line chemical analyses can be used for a chemical process when slow kinetics allows time to take a sample to the laboratory and the system provides a recovery mechanism that returns the system to statistical control without intervention of the operator. The objective for this study has been the implementation of do-it-right-the-first-time and just-in-time philosophies. The Environment Control and Life Support Systems (ECLSS) water reclamation system that adds iodine for biocidal control is an ideal candidate for the study and implementation of do-it-right-the-first-time technologies.

Arendale, W. F.↗

Computer-controlled multi-parameter mapping of 3D compressible flowfields using planar laser-induced iodine fluorescence

A computer-controlled technique, using planar laser-induced iodine fluorescence, for measuring complex compressible flowfields is presented. A new laser permits the use of a planar two-line temperature technique so that all parameters can be measured with the laser operated narrowband. Pressure and temperature measurements in a step flowfield show agreement within 10 percent of a CFD model except in regions close to walls. Deviation of near wall temperature measurements from the model was decreased from 21 percent to 12 percent compared to broadband planar temperature measurements. Computer-control of the experiment has been implemented, except for the frequency tuning of the laser. Image data storage and processing has been improved by integrating a workstation into the experimental setup reducing the data reduction time by a factor of 50.

Donohue, James M.↗

Directly solar-pumped iodine laser for beamed power transmission in space

A new approach for development of a 50-kW directly solar-pumped iodine laser (DSPIL) system as a space-based power station was made using a confocal unstable resonator (CUR). The CUR-based DSPIL has advantages, such as performance enhancement, reduction of total mass, and simplicity which alleviates the complexities inherent in the previous system, master oscillator/power amplifier (MOPA) configurations. In this design, a single CUR-based DSPIL with 50-kW output power was defined and compared to the MOPA-based DSPIL. Integration of multiple modules for power requirements more than 50-kW is physically and structurally a sound approach as compared to building a single large system. An integrated system of multiple modules can respond to various mission power requirements by combining and aiming the coherent beams at the user's receiver.

Choi, S. H.↗

Solar-pumped photodissociation iodine laser

The scientific feasibility of a solar-pumped iodine photodissociation laser for space applications is under investigation. Recently, a 2-W CW output for more than one hour was achieved using n-C3F7I vapor as the laser material and a vortex-stabilized argon arc as the light source.

Lee, J. H.↗

Amplified spontaneous emission in solar-pumped iodine laser

The amplified spontaneous emission (ASE) from a long pulse, solar-simulating radiation pumped iodine laser amplifier is studied. The ASE threshold pump intensity is almost proportional to the inverse of the laser gain length when the gas pressure is constant in the laser tube.

Cho, Yong S.↗

A method to remove intercalates from bromine and iodine intercalated carbon fibers

Upon exposure to room-temperature fluorine, intercalated carbon fibers (containing either bromine alone or iodine and bromine together) become heavier and less stable. For Amoco P-100 graphitized carbon fibers which were intercalated with 18 percent bromine by weight, 1 hr of fluorine exposure results in a large weight increase, but causes only a small decrease in thermal stability. More than l hr of fluorine exposure time results in small additional increases in fiber weight, but significant further decreases in fiber thermal stability. Such phenomena do not occur if the fluorine exposure is at 250 C. These observations suggest the mechanism that at room temperature, fluorine is absorbed quickly by the intercalated fibers and intercalated slowly into the fibers. Most of the original intercalates are replaced by fluorine in the process of fluorine intercalation. Under an inert environment, the bromine intercalated fibers are much more thermally stable. After 800 C vacuum heating for two weeks, the brominated fibers lost about 45 percent of their bromine, and their resistivity increased from 64 omega-cm to a range of 95 to 170 micro omega-cm. This is still much lower than the 300 micro omega-cm value for pristine P-100. For practical purposes, in order to preserve their thermal stability, brominated fibers need to be protected from exposure to fluorine at room temperature, or to any intercalate at a temperature where, upon direct contact to graphite, an intercalation compound can easily be formed.

Hung, Ching-Cheh↗

Room-Temperature Fluorine-Induced Decrease in the Stability of Bromine and Iodine Intercalated Carbon Fibers

Upon exposure to room-temperature fluorine, intercalated carbon fibers (containing either bromine alone or iodine and bromine together) become heavier and less stable. For Amoco P-100 graphitized carbon fibers, which were intercalated with 18 wt percent bromine, 1 hour of fluorine exposure resulted in a large weight increase but caused only a small decrease in thermal stability. An additional 89 hours of fluorine exposure time resulted in small additional increases in fiber weight, but significant further decreases in fiber thermal stability. Such phenomena of weight increase and stability decrease do not occur if the intercalated fibers are exposed to 250 C fluorine. These observations suggest that, at room temperature, fluorine is absorbed quickly by the intercalated fibers and is intercalated slowly into the fibers. Most of the original intercalates are replaced by fluorine in the process of fluorine intercalation. In an inert environment, the bromine intercalated fibers are much more thermally stable. After 800 C vacuum heating for 2 weeks, the brominated fibers lost about 45% of their bromine, and their resistivity increased from 64 mu(Omega)-cm to a range of 95-170 mu(Omega)-cm. This is still much lower than the value of 300 mu(Omega)-cm for pristine P-100. For practical purposes, to preserve their thermal stability, brominated fibers need to be protected from exposure to fluorine at room temperature or to any intercalate at a temperature where, upon direct contact with graphite, an intercalation compound can easily be formed.

Hung, Ching-Cheh↗

Comparison of the Effects of Iodine and Iodide on Thyroid Function in Humans

The present experiment in humans failed to confirm the differential effect of I(sub 2) on maintenance of serum T(sub 4) concentrations relative to the effects of I(-) that was observed in prior experiments in rats. The reaction of I(sub 2) with metabolites of thyroid hormones in the intestine that appears responsible for this effect in rats probably also exists at some level in humans. The present results suggest that the concentrations of such metabolites in the human intestinal tract are too small to significantly affect circulating concentration of T(sub 4). However, based on the elevations in TSH, there should be some concern over the potential impacts of chronic consumption of iodine in drinking water.

Robison, Linda M.↗

Collisional Shift and Broadening of Iodine Spectral Lines in Air Near 543 nm

The collisional processes that influence the absorption of monochromatic light by iodine in air have been investigated. Measurements were made in both a static cell and an underexpanded jet flow over the range of properties encountered in typical compressible-flow aerodynamic applications. Experimentally measured values of the collisional shift and broadening coefficients were 0.058 +/- 0.004 and 0.53 +/- 0.010 GHz K(exp 0.7)/torr, respectively. The measured shift value showed reasonable agreement with theoretical calculations based on Lindholm-Foley collisional theory for a simple dispersive potential. The measured collisional broadening showed less favorable agreement with the calculated value.

Fletcher, D. G.↗