Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The ionization length in plasmas with finite temperature ion sources

The ionization length is an important quantity which up to now has been precisely determined only in plasmas which assume that the ions are born at rest, i.e., in discharges known as 'cold ion-source' plasmas. Presented here are the results of our calculations of the ionization lengths in plasmas with an arbitrary ion source temperature. Harrison and Thompson (H and T) [Proc. Phys. Soc. 74, 145 (1959)] found the values of this quantity for the cases of several ion strength potential profiles in the well-known Tonks-Langmuir [Phys. Rev. 34, 876 (1929)] discharge, which is characterized by 'cold' ion temperature. This scenario is also known as the 'singular' ion-source discharge. The H and T analytic result covers cases of ion sources proportional to exp(betaPHI) with PHI the normalized plasma potential and beta=0,1,2 values, which correspond to particular physical scenarios. Many years following H and T's work, Bissell and Johnson (B and J) [Phys. Fluids 30, 779 (1987)] developed a model with the so-called 'warm' ion-source temperature, i.e., 'regular' ion source, under B and J's particular assumption that the ionization strength is proportional to the local electron density. However, it appears that B and J were not interested in determining the ionization length at all. The importance of this quantity to theoretical modeling was recognized by Riemann, who recently answered all the questions of the most advanced up-to-date plasma-sheath boundary theory with cold ions [K.-U. Riemann, Phys. Plasmas 13, 063508 (2006)] but still without the stiff warm ion-source case solution, which is highly resistant to solution via any available analytic method. The present article is an extension of H and T's results obtained for a single point only with ion source temperature T{sub n}=0 to arbitrary finite ion source temperatures. The approach applied in this work is based on the method recently developed by Kos et al. [Phys. Plasmas 16, 093503 (2009)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL (invited)

There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e {mu}A of O{sup 7+}, 505 e {mu}A of Xe{sup 20+}, 306 e {mu}A of Xe{sup 27+}, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

43 PARTICLE ACCELERATORS↗

Measurement of the high energy component of the x-ray spectra in the VENUS electron cyclotron resonance ion source (abstract only)

High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (versatile ECR for nuclear science), produce large amounts of x rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different than for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates in dependence of various ion source parameters such as confinement fields, minimum B-field, rf power, and heating frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Laser ion source with long pulse width for RHIC-EBIS

The Electron Beam Ion Source (EBIS) at Brookhaven National Laboratory is a new heavy ion-projector for RHIC and NASA Space Radiation Laboratory. Laser Ion Source (LIS) with solenoid can supply many kinds of ion from solid targets and is suitable for long pulse length with low current as ion provider for RHIC-EBIS. In order to understand a plasma behavior for fringe field of solenoid, we measure current, pulse width and total ion charges by a new ion probe. The experimental result indicates that the solenoid confines the laser ablation plasma transversely. Laser ion source needs long pulse length with limited current as primary ion provider for RHIC-EBIS. New ion probe can measure current distribution for the radial positions along z axis. The beam pulse length is not effected by magnetic field strength. However, the currents and charges decay with the distance from the end of solenoid. These results indicate that solenoid field has important role for plasma confinement not longitudinally but transversely and solenoid is able to have long pulse length with sufficient total ion charges. Moreover, the results are useful for a design of the extraction system for RHIC-EBIS.

43 PARTICLE ACCELERATORS↗

Beam Uniformity Controllable Ion Source with a Long Slit

With scaling up of a substrate of LCD and silicon, an ion source with a longer extraction area than the substrate has been used for an ion implantation system. Wide sheet beam emitted from a long extraction area is effective to decrease space charge effect of a high current ion beam. An ion source which has this structure has been applied for FPD. This ion source controls the source plasma partially. This function is one of the methods to adjust the uniformity of the ion sheet beam. However, there are technical difficulties for this ion source. Therefore, we have developed three types of ion sources which have a longer extracting slit than the substrate and different direction of the source magnetic field. This paper shows the structures and the experimental result of these ion sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Power efficiency improvements with the radio frequency H{sup −} ion source

CW 13.56 MHz radio frequency-driven H{sup −} ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H{sup −} beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation of the main plasma from the plasma electrode. While the original system provided better control over the e{sup −}/H{sup −} ratio, the new configuration has led to a higher production efficiency of 1 mA H{sup −} at 1.75 kW RF power. The latest results and upgrade plans are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High current H{sub 2}{sup +} and H{sub 3}{sup +} beam generation by pulsed 2.45 GHz electron cyclotron resonance ion source

The permanent magnet 2.45 GHz electron cyclotron resonance ion source at Peking University can produce more than 100 mA hydrogen ion beam working at pulsed mode. For the increasing requirements of cluster ions (H{sub 2}{sup +} and H{sub 3}{sup +}) in linac and cyclotron, experimental study was carried out to further understand the hydrogen plasma processes in the ion source for the generation of cluster ions. The constituents of extracted beam have been analyzed varying with the pulsed duration from 0.3 ms to 2.0 ms (repetition frequency 100 Hz) at different operation pressure. The fraction of cluster ions dramatically increased when the pulsed duration was lower than 0.6 ms, and more than 20 mA pure H{sub 3}{sup +} ions with fraction 43.2% and 40 mA H{sub 2}{sup +} ions with fraction 47.7% were obtained when the operation parameters were adequate. The dependence of extracted ion fraction on microwave power was also measured at different pressure as the energy absorbed by plasma will greatly influence electron temperature and electron density then the plasma processes in the ion source. More details will be presented in this paper.

43 PARTICLE ACCELERATORS↗

Status of ion sources at National Institute of Radiological Sciences

The National Institute of Radiological Sciences (NIRS) maintains various ion accelerators in order to study the effects of radiation of the human body and medical uses of radiation. Two electrostatic tandem accelerators and three cyclotrons delivered by commercial companies have offered various life science tools; these include proton-induced x-ray emission analysis (PIXE), micro beam irradiation, neutron exposure, and radioisotope tracers and probes. A duoplasmatron, a multicusp ion source, a penning ion source (PIG), and an electron cyclotron resonance ion source (ECRIS) are in operation for these purposes. The Heavy-Ion Medical Accelerator in Chiba (HIMAC) is an accelerator complex for heavy-ion radiotherapy, fully developed by NIRS. HIMAC is utilized not only for daily treatment with the carbon beam but also for fundamental experiments. Several ECRISs and a PIG at HIMAC satisfy various research and clinical requirements.

07 ISOTOPE AND RADIATION SOURCES↗

Note: Enhanced production of He{sup +} from the Versatile Ion Source (VIS) in off-resonance configuration

The Versatile Ion Source (VIS) is a microwave discharge ion source installed at INFN-LNS and here used as test-bench for the production of high intensity low emittance proton beams and for studies on plasma physics. A series of measurements have been carried out with VIS in order to test the source with light ions. In particular a He{sup +} beam has been characterized in terms of plasma discharge parameters. The experiment has been triggered by the observation of X-radiation emission from the plasma for some configuration of the magnetic field profile. The plasma electron energy distribution function is in fact modified when in some regions of the plasma chamber under-resonance discharge takes place, fulfilling the condition that allows the electromagnetic wave to electrostatic wave conversion. These tests allowed obtaining more than 50 mA of He{sup +} beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New ion source for KSTAR neutral beam injection system

The neutral beam injection system (NBI-1) of the KSTAR tokamak can accommodate three ion sources; however, it is currently equipped with only one prototype ion source. In the 2010 and 2011 KSTAR campaigns, this ion source supplied deuterium neutral beam power of 0.7-1.6 MW to the KSTAR plasma with a beam energy of 70-100 keV. A new ion source will be prepared for the 2012 KSTAR campaign with a much advanced performance compared with the previous one. The newly designed ion source has a very large transparency ({approx}56%) without deteriorating the beam optics, which is designed to deliver a 2 MW injection power of deuterium beams at 100 keV. The plasma generator of the ion source is of a horizontally cusped bucket type, and the whole inner wall, except the cathode filaments and plasma grid side, functions as an anode. The accelerator assembly consists of four multi-circular aperture grids made of copper and four electrode flanges made of aluminum alloy. The electrodes are insulated using PEEK. The ion source will be completed and tested in 2011.

43 PARTICLE ACCELERATORS↗

Extracted ion current density in close-coupling multi-antenna type radio frequency driven ion source: CC-MATIS

Positive ions are extracted by using a small extractor from the Close-Coupling Multi-Antenna Type radio frequency driven Ion Source. Two types of RF antenna are used. The maximum extracted ion current density reaches 0.106 A/cm{sup 2}. The RF net power efficiency of the extracted ion current density under standard condition is 11.6 mA/cm{sup 2}/kW. The efficiency corresponds to the level of previous beam experiments on elementary designs of multi-antenna sources, and also to the efficiency level of a plasma driven by a filament in the same chamber. The multi-antenna type RF plasma source is promising for all metal high density ion sources in a large volume chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status and operation of the Linac4 ion source prototypes

CERN's Linac4 45 kV H{sup −} ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma, and pulsed high voltages are described. The first experimental results of two prototypes relying on 2 MHz RF-plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H{sup −} beam of 16–22 mA which has successfully been used for the commissioning of the Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ) accelerator, and chopper of Linac4.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the CW starter plasma RF matching network for operating the SNS H{sup −} ion source with lower H{sub 2} flows

The Spallation Neutron Source H{sup −} ion source is operated with a pulsed 2-MHz RF (50-60 kW) to produce the 1-ms long, ∼50 mA H{sup −} beams at 60 Hz. A continuous low power (∼300 W) 13.56-MHz RF plasma, which is initially ignited with a H{sub 2} pressure bump, serves as starter plasma for the pulsed high power 2-MHz RF discharges. To reduce the risk of plasma outages at lower H{sub 2} flow rates which is desired for improved performance of the following radio frequency quadrupole, the 13.56-MHz RF matching network was characterized over a broad range of its two tuning capacitors. The H-α line intensity of the 13.56-MHz RF plasma and the reflected power of the 13.56-MHz RF were mapped against the capacitor settings. Optimal tunes for the maximum H-α intensity are consistent with the optimal tunes for minimum reflected power. Low limits of the H{sub 2} flow rate not causing plasma outages were explored within the range of the map. A tune region that allows lower H{sub 2} flow rate has been identified, which differs from the optimal tune for global minimum reflected power that was mostly used in the past.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of closed shell breeding of cesium ions with an electron beam ion source

An electron beam ion source serves as a charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) at the Argonne Tandem Linac Accelerator System (ATLAS). The source accepts radioactive beams of 1+ or 2+ ions and raises their charge state for post-acceleration by ATLAS. The efficiency of this process impacts the length of each experiment and, hence, the type and number of experiments that can be run in each program cycle. Recent efforts to improve the charge breeding efficiency for the 80 < A < 160 species typical of CARIBU have focused on utilizing the closed shell breeding technique. Here, with this technique, the electron beam energy is manipulated to take advantage of the large gap in ionization energies at shell closures and selectively populate a single charge state. Charge breeding studies with stable cesium ions have demonstrated an absolute efficiency of 72% for Cs 27+ and a total efficiency of 93%. The Cs 27+ efficiency result represents a factor of 3 improvement over the previous best charge breeding result of 23% for Cs 27+ .

Vondrasek, R. [Argonne National Laboratory (ANL), ↗

Ion-Optical System of an Ion Source with Energy Focusing in the Formed Beam

Ways to reduce ion beam intensity losses in a mass spectrometric ion source, which are caused by chromatic aberration of its immersion ion-optical system, are considered. These losses are rather significant in forming a beam from ions with a large energy spread. The reduction of aberration losses is especially important when ion sources are used jointly with mass analyzers with energy focusing. It is shown that these losses can be reduced significantly by using a new type of ion-optical system of the ion source, which includes achromatic elements. A special method for calculating such elements is given. Computer simulations have shown high efficiency of such elements in the ion-optical path of ion sources of mass spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of source tuning parameters on the plasma potential of heavy ions in the 18 GHz high temperature superconducting electron cyclotron resonance ion source

Plasma potentials for various heavy ions have been measured using the retarding field technique in the 18 GHz high temperature superconducting ECR ion source, PKDELIS [C. Bieth, S. Kantas, P. Sortais, D. Kanjilal, G. Rodrigues, S. Milward, S. Harrison, and R. McMahon, Nucl. Instrum. Methods B 235, 498 (2005); D. Kanjilal, G. Rodrigues, P. Kumar, A. Mandal, A. Roy, C. Bieth, S. Kantas, and P. Sortais, Rev. Sci. Instrum. 77, 03A317 (2006)]. The ion beam extracted from the source is decelerated close to the location of a mesh which is polarized to the source potential and beams having different plasma potentials are measured on a Faraday cup located downstream of the mesh. The influence of various source parameters, viz., RF power, gas pressure, magnetic field, negative dc bias, and gas mixing on the plasma potential is studied. The study helped to find an upper limit of the energy spread of the heavy ions, which can influence the design of the longitudinal optics of the high current injector being developed at the Inter University Accelerator Centre. It is observed that the plasma potentials are decreasing for increasing charge states and a mass effect is clearly observed for the ions with similar operating gas pressures. In the case of gas mixing, it is observed that the plasma potential minimizes at an optimum value of the gas pressure of the mixing gas and the mean charge state maximizes at this value. Details of the measurements carried out as a function of various source parameters and its impact on the longitudinal optics are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of series H{sup −} multicusp ion source at China Institute of Atomic Energy

The development of H{sup −} multicusp ion sources has been carried out at China Institute of Atomic Energy (CIAE) for more than ten years. The first H{sup −} ion source with 5.2 mA was made in 2002. After improving the configured magnetic field, a H{sup −} ion source of 10 mA was made in 2004, and the beam intensity of 15 mA was obtained in 2008 after further improvements of the filter field. The beam intensity of 18 mA was achieved in 2010 following the in-depth study and optimization on some essential operation conditions. Now a series of H{sup −} cusp sources with different sizes and beam intensity ranging from 3 mA to 18 mA have been successfully developed at CIAE. All the ion sources can fast finish the test on the test stand now, since all the connections are modularized and can fit all kinds of H{sup −} mulitcusp source of CIAE. The development status of the various H{sup −} multicusp ion sources at CIAE are presented in the paper.

43 PARTICLE ACCELERATORS↗