Advanced Test Reactor Neutron Dosimetry Report – 174 A & B

Results of neutron dosimetry measurements in ATR for cycle 174 A B are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microstructure, electrical resistivity, and tensile properties of neutron-irradiated Cu–Cr–Nb–Zr

High strength, high conductivity copper alloys that can resist creep at high temperatures are one of the primary candidates for efficient heat exchangers in fusion reactors. Cu–Cr–Nb–Zr (CCNZ) alloys, which were designed to improve the strength and creep life of ITER Cu–Cr–Zr (CCZ) reference alloys, have been found to have comparable electrical conductivity and tensile properties to CCZ alloys. The measured creep rupture times for these improved alloys is about ten times higher than the ITER reference alloys at 90–125 MPa at 500 °C. However, the effects of neutron irradiation on these alloys, and the ensuing material properties, have not been studied; thus, their utility in a fusion reactor environment is not well understood. This study characterizes the room temperature mechanical and electrical properties of a neutron-irradiated CCNZ alloy and compares them to a neutron-irradiated ITER reference heat sink CCZ alloy. Tensile specimens were neutron irradiated in the High Flux Isotope Reactor (HFIR) to 5 dpa between 250 °C and 325 °C. Post-irradiation characterization included electrical resistivity measurements, hardness, and tensile tests. Microstructural evaluation used scanning electron microscopy, energy dispersive x-ray spectroscopy, and atom probe tomography to characterize the irradiation-produced changes in the microstructure and investigate the mechanistic processes leading to post-irradiation properties. Transmutation calculations were validated with composition measurements from atom probe data and used to calculate contributions to the increased electrical resistivity measured after irradiation. Comparisons with CCZ alloys in the same irradiation heat found that the post-irradiated CCNZ and CCZ alloys had comparable electrical resistivity. Although CCNZ alloys suffered more irradiation hardening than CCZ, the overall tensile behavior deviated very little from non-irradiated values in the temperature range studied.

36 MATERIALS SCIENCE↗

Femto-second Laser’s Enabling New Length Scale Fabrications for Rapid Post Irradiation Examination of Materials: Concluding LDRD Project Poster

Mechanical testing campaigns are required to qualify materials for advanced reactor conditions, yet economical and safety limitations restrict the number of standardized mechanical tests that can be performed. Reducing the size of the sample is one approach to addressing these challenges and to accelerating testing. Previous research has shown that smaller mechanical test samples produce higher yield and ultimate stress values compared to values measured from standard sample sizes: the “smaller is stronger” effect. Specimens used in accelerated material testing campaigns must reflect bulk material performance to enable engineering scale material property measurement. The objective of this research project was to determine if engineering scale mechanical behavior—the yield stress—could be measured with micro-tensile test samples smaller than traditional standard testing geometries. The relationship between yield stress and sample size was explored with two different nuclear-relevant structural materials: Zircaloy-4 and tungsten. Mechanical testing of both metals demonstrated decreasing yield stress values with increasing sample gauge size across three different sizes. Yield stress values from the largest gauge size, fabricated with a femto-second laser ablation system, approach bulk material yield stress values reported in published literature. Preliminary analysis of the tungsten samples indicates the yield stress value depends on the grain characteristics within the gauge section, in addition to the gauge size. Accompanying modeling efforts, including response surface generation and crystal plasticity approaches, further demonstrated that the size of the sample gauge section alone cannot explain the change in yield stress values.

36 MATERIALS SCIENCE↗

Analysis of attenuation data from the decommissioned ZIon unit 1 reactor pressure vessel beltline weld

In order to examine the attenuation of radiation damage through the thickness of an irradiated reactor pressure vessel (RPV), four segments were acquired from the Zion Unit 1 power plant RPV after the plant was decommissioned. The Zion Unit 1 RPV Beltline Weld Segment 1 was cut into seven blocks, consisting of five base metal and two beltline welds from the high fluence region of the segment. Through-wall test specimens were machined and tested. Specimens included those used for Charpy impact, Master Curve fracture toughness testing, and chemical analysis. The observed through-thickness ductile-to-brittle transition temperatures in the beltline weld deviated significantly from the expected behavior based on the attenuation of fast fluence as a function of depth into the RPV. Beginning at the inside surface, the 41-J Charpy transition temperature was either flat or slightly increasing until the ¾ -T location. The results of a simple, model-based analysis of the Zion beltline weld material that included the irradiation conditions and material chemistry were generally consistent with industry trend curves and the standard attenuation model, rather than the observed data. Although there was no archive material from the RPV available to permit measurement of the unirradiated properties, fracture toughness specimens fabricated from archive surveillance weld were used to obtain an estimate of the initial through-thickness values of the Charpy transition temperature. The Charpy shifts obtained using this approach were similarly in disagreement with the predictions of the US NRC Regulatory Guide 1.99, Rev. 2. However, testing of irradiated Charpy specimens taken from the RPV following post-irradiation annealing (10 hr. at 500 °C) provided a quite different estimate of the unirradiated properties which improved the agreement between the inferred through-thickness Charpy shifts and exponential attenuation model included in Regulatory Guide 1.99/2. In conclusion, the analysis of the Zion data and data obtained in previous post-mortem examinations of decommissioned RPVs indicates that more work is needed to understand the through-thickness properties of RPV materials in order to properly assess through-wall damage attenuation.

Charpy impact↗

Demonstration of the surveillance test article for an advanced reactor surveillance test program

Operational environments in generation IV reactors involve corrosive and irradiative conditions at elevated temperatures. Typical reactor operations consist of transients which impose cyclic loads on reactor components. These cyclic loads, combined with corrosive and irradiative environments, result in synergistic degradation of component materials. However, limited data exists on the coupled damage effects on materials for reactor environments. While the surrogate material surveillance concept has been used in light water reactors to assess irradiation damage, existing material surveillance technologies are not suitable for in-situ monitoring of coupled material degradation. The materials surveillance program focuses on material degradation management and the estimation of remaining life of reactor components through surveillance test articles. This paper presents the design and analysis methodology of a bi-metal surveillance test article, which uses difference in thermal expansion coefficient between two metals to induce in-situ cyclic loads. This report presents the work conducted in FY 25, to test the surveillance test article in air and salt environments. These test specimens were evaluated after thermal cycle exposure and remaining life is measured through creep test.

36 - MATERIALS SCIENCE↗

Swelling and Fission Gas Release of U-10Mo and U-17Mo Following Neutron Irradiation at 250 – 500°C

The performance of metallic fuel alloys, U-10Mo and U-17Mo, was examined using the MiniFuel test system in the High Flux Isotope Reactor. Approximately 0.8 mm thick disks were irradiated at target temperatures of 250°C, 350°C, 450°C, and 500°C up to three different fission densities, culminating at a maximum fission density of 6.8 × 10 20 cm −3 . Fission rates decayed from 3 – 6 × 10 13 cm −3 s −1 to 2 – 4 × 10 13 cm −3 s −1 over the course of the longest, eight cycle, irradiation as the 235 U was consumed and the 239 Pu concentration accumulated. Actual irradiation temperature on the last day of irradiation was measured via dilatometry using the SiC passive thermometry recovered from the MiniFuel subcapsules and compared favorably with the thermal calculations using as-built geometry and test conditions. Furthermore, average simulated temperatures were within 50°C of the target temperatures, except for the 500°C irradiation, for which the temperature variation was 62°C, 32°C, and 90°C in the in two, four, and eight cycle irradiations, respectively. Fission gas release (FGR) measurements showed no release above recoil for any U-17Mo fuels or for the U-10Mo fuel irradiated at 250°C. Finally, significant (40%–80%) FGR was found for the medium- to highest-burnup U-10Mo samples irradiated at target temperatures 350°C–500°C. Significant FGR correlated with sample thickness swelling, which was as high as 13%–35% for high-release samples and below 7% for all other (low–gas release) samples.

FGR↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175A-1

Results of neutron dosimetry measurements in ATR for cycle 175A-1 are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

175A↗

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175B-1

Results of neutron dosimetry measurements in ATR for cycle 175B-1 are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

175B↗

HDG-2 & VIC Design Updates

HDG-2 and VIC Design updates. Including background, HDG-1 challenges, HDG-2 Mitigation efforts, Effect of updated ring model, Pressure boundary surface finish, and conclusions. Vendor Irradiation Capsule (VIC) to include, background, design overview, testing and neutronics results, and models.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Separation of terbium from proton-irradiated gadolinium oxide targets – development of an effective, scalable and automatable process

This work reports an effective and scalable radiochemical separation process for isolating terbium from Gd 2 O 3 . The separation process uses three commercially available extraction chromatography resin columns, has been implemented on a computer-controlled chemistry module, and tested with 100 mg quantities of proton-irradiated nat Gd 2 O 3 . Here, the 4-hour separation procedure isolated radioterbium in 1.3 mL of 0.01 M HCl with 80 ±8% radiochemical yield and a Gd decontamination factor >(1.2 ± 0.3)·10 5 .

Adjacent lanthanide separation↗

Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

14 SOLAR ENERGY↗

Micro-tensile Properties of Fueled Irradiated AGR-2 TRISO-coated Particle Buffer, IPyC, and SiC Interlayer Regions

Tristructural isotropic (TRISO) coated nuclear fuel particles are proving to be a versatile fuel form for new reactor designs. Understanding the bounding strength and failure mode of each coating interface is important to both fuel quality evaluation and failure prediction. A mechanism of key significance is failure of the silicon carbide (SiC) layer to retain fission products due to incomplete tearing of the buffer layer. This is a two-step mechanism involving both mechanical failure in the buffer and inner pyrolytic carbon (IPyC) layers and degradation of the SiC layer through palladium silicides at the IPyC-SiC interface. However, the mechanical properties of TRISO particle coating layers have yet to be fully characterized due to the small dimension of TRISO fuel particles and high radioactivity. To investigate this mechanism, in situ micro-tensile properties of the buffer, IPyC, SiC, buffer-IPyC, and IPyC-SiC interlayer regions of fueled TRISO particles have been tested at both as-fabricated and irradiated conditions. Determination of the mechanical properties of these TRISO particle regions will lead to a better understanding of the SiC layer failure mechanism and enable progress towards TRISO fuel qualification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Thermal Conductivity Measurements on Irradiated TRISO Fuel at IMCL

INL is leading the development and testing of accident tolerant fuels: fuels that resist melting down and that contain radioactive byproducts, preventing their release into their environment. One such fuel, called TRi-structural ISOtropic particle fuel (TRISO) See Fig 1. Understanding how heat propagates through a fuel is essential to fuel development and qualification. When irradiated in a reactor the properties that affect heat transport change. Our objective is to quantify the change in thermal properties of TRISO after irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing High Burnup U-19Pu-10Zr Fuel Performance against Historical and Modeled Behavior

Advancing the deployment of sodium-cooled fast reactors (SFRs) requires thorough testing of metallic fuel pins under accident conditions to establish safe operational limits of high burnup fuel. To conduct transient testing, a comprehensive understanding of steady-state fuel behavior obtained through both experimental characterization and accurate predictive capabilities is needed. This study comparatively assesses the steady-state irradiation performance of two high burnup U-19Pu-10Zr fuel pins, DP-36 and DP-40, irradiated under prototypic fast reactor conditions in preparation for planned safety testing at the Transient Reactor Test Facility. Since DP-40 was designated for use in the test and DP-36 serves as its sibling pin, non-destructive, engineering-scale post-irradiation examinations (PIE) were conducted on both pins while destructive examinations were performed exclusively on DP-36. The results were then assessed against historical performance data from similar fuel pins irradiated in the Experimental Breeder Reactor-II. Additionally, the steady-state irradiation of each pin was modeled using the BISON fuel performance code to assess the accuracy of current modeling capabilities in predicting the baseline irradiation behavior. Non-destructive examinations included neutron radiography to measure fuel column elongation, gamma scanning to verify pin integrity and fission product migration, and profilometry to assess dimensional changes. Benchmarking against existing PIE data revealed consistent patterns in axial fuel column growth and cladding diametral strain, though both pins exhibited longer low-density “fluff” structures, which can have implications for core reactivity and source term calculations. Destructive examinations on DP-36 included fission gas release analysis and sectioning for optical microscopy, which showed more complex constituent redistribution patterns than the traditionally accepted 3-ring model. The axial evolution of fractional areas and porosities of each of the redistributed zones were quantified and presented. Modeling comparisons showed agreement in fractional fission gas release but consistently overestimated axial and radial swelling and disagreed with measured axial porosity patterns. These conservative overpredictions suggested that the pins would appear closer to failure or operational limits at the start of transient tests, potentially leading to higher strain accumulation during the transient. While conservative estimates provide safety margins, they can negatively impact fuel economics. A review of the swelling models identified areas for improvement in the gaseous swelling, solid swelling, and fuel hot-pressing models when applied to ternary fuel. The results of this study highlight the critical importance of conducting pre-test characterization on both test and sibling pins to accurately capture steady-state fuel behavior, providing a precise baseline for post-test evaluations and essential inputs for transient modeling of the planned experiments. The analysis also revealed significant data gaps that require further investigation to enhance the understanding and prediction of fuel swelling and pore dynamics. Collecting comprehensive data across different irradiation conditions, burnup levels, and fuel compositions are essential for refining existing models and developing mechanistic models for both binary and ternary metallic fuels, ultimately improving the integration of modeling and experimental approaches in accident testing.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)↗

Analysis of Deformation and Fracture Mechanisms in the Harvested High-Dose Baffle-Former Bolt with Stress-Corrosion Cracks Formed While in Service

This report presents the results of advanced mechanical testing conducted on miniature tensile specimens excised from an irradiated baffle-former bolt, a commercial pressurized water reactor component. The specimens were extracted from the midsection of the bolt shank, where the estimated damage dose reached 23 displacements per atom. The mechanical testing included the following tests: (1) conventional tensile testing at room temperature, augmented by digital image correlation (DIC) to enable noncontact strain measurements, and (2) in situ tensile testing within a scanning electron microscopy (SEM) instrument equipped with energy-dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD) detectors to evaluate active deformation and fracture mechanisms. Additionally, SEM fractographic analysis revealed alterations in the fracture mechanism from a predominantly ductile fracture in nonirradiated steel to a mixed fracture mode (still dominating ductile and minor cleavage spots) in irradiated specimens derived from the baffle bolts. The findings indicate a complex strain localization behavior for in-service irradiated steel specimens. Beyond conventional necking at the macro scale and defect-free channel formation at the micro scale, DIC results identified the presence of deformation bands approximately 100 μm in width. These bands consist of chains of grains exhibiting elevated local strain levels and may be considered an intermediate or mesoscale level of strain localization. These bands become discernible near the yield stress as localized hot spots, areas of elevated strain, persisting throughout most of the experiment. The formation of mesoscale deformation bands as a strain localization mechanism may exacerbate the defect-free channel formation in irradiated materials, further promoting irradiation-assisted stress corrosion crack initiation.