Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotopic ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Exploration for Blind Geothermal Resources in the State of Hawaii Utilizing Dissolved Noble Gasses in Well Waters

This study is an extension of the Hawaii Play Fairway Analysis (PFA), a statewide geothermal exploration project funded by the United States Department of Energy. Based on results from prior phases of the PFA, this project targeted 66 wells on the islands of Hawaii, Maui, Lanai, Oahu, and Kauai for sampling of dissolved noble gases, trace metals, common ions, and the stable isotopes 2H and 18O. Ultimately, 23 of the 66 well targets were sampled. The noble gas helium is used as an indicator of geothermal heat when excess 3He and/or 4He is present when compared to the atmospheric ratio of those isotopes (R/Ra). R/Ra is minimally affected by dilution and transport, allowing even those wells not perfectly situated over a geothermal system to indicate a geothermal anomaly. R/Ra anomalies are present on every island in this study. There is a strong correlation between R/Ra anomalies and proximity to rift zones and calderas. Across the islands R/Ra ranged from 15-16 on Kilauea's lower east rift zone, which is a mantle plume value, to 0.37 on Lanai, which is a crustal value. The majority of anomalous well samples had R/Ra values consistent with an upper mantle source. Mixing between upper mantle and crustal helium is evident on all islands. Geographically, R/Ra decreases from the high at Kilauea to upper mantle values at Mauna Loa, and remains at upper mantle values for all wells across the other volcanoes, with the exception of two of four sampled wells on Lanai.

15 GEOTHERMAL ENERGY↗

Daily water stable isotopes, transpiration, and matrix potential data for an aspen and engelmann stand in the East River Watershed (version 2)

We provide daily stable isotope (2H & 18O) ratios in soil water and xylem (plant stem) water, as well as the sap flow (transpiration) and the soil's matric potential at a forested site near Gothic, Colorado, in the East River catchment. We measured the stable isotopic composition of the transpiration and the daily transpiration flux sum of three aspen and three engelmann spruce. In both forest stands, we installed a soil profile and measured the soil matric potential at 15, 30, and 60 cm depth as well as the stable isotopes of soil pore water at 5, 10, 30, 60, and 90 cm depths. All isotope measurements were done in situ via vapor probes connected to a cavity ring down spectrometer (Picarro L1240i).We further report the daily meteorological data observed at billy barr near our study site. We also provide for each tree the relative share of root water uptake derived from the isotope measurements via a Bayesian mixing model (MixSIAR).The daily data is provided as a time series in "Iso_MP_Sap_DataDaily_ESSDiveUpload.csv" and the units are provided in "dd.csv"; the location of the instrumented trees and soil profiles are given as latitude and longitude coordinates saved as CSV and KMZ files; and a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata.The data was gathered to investigate the short-term changes of the water sources (i.e., variation of root water uptake from different soil depths) of the studied subalpine trees.Update 07/16/2025: The relative and absolute plant water uptake depths were grouped to ensure that the MixSIAR model was applied with endmembers that differed in their d2H value by at least 3 permill and at least 1 permill for d18O. Whenever the difference between observed d2H values for two or more probes at neighboring depths was less than 3 permill, we used the average value for the source water endmember. For days at which probes that were not next to each other measurements did not differ at least 3 permill, the average of all probes between these two depths was used as the water source endmember representing the depth range between these two probes.

54 ENVIRONMENTAL SCIENCES↗

A dry ancient plume mantle from noble gas isotopes

Primordial volatiles were delivered to terrestrial reservoirs during Earth’s accretion, and the mantle plume source is thought to have retained a greater proportion of primordial volatiles compared with the upper mantle. This study shows that mantle He, Ne, and Xe isotopes require that the plume mantle had low concentrations of volatiles like Xe and H 2 O at the end of accretion compared with the upper mantle. A lower extent of mantle processing alone is not sufficient to explain plume noble gas signatures. Ratios of primordial isotopes are used to determine proportions of solar, chondritic, and regassed atmospheric volatiles in the plume mantle and upper mantle. The regassed Ne flux exceeds the regassed Xe flux but has a small impact on the mantle Ne budget. Pairing primordial isotopes with radiogenic systems gives an absolute concentration of 130 Xe in the plume source of ∼1.5 × 10 7 atoms 130 Xe/g at the end of accretion, ∼4 times less than that determined for the ancient upper mantle. A record of limited accretion of volatile-rich solids thus survives in the He-Ne-Xe signatures of mantle rocks today. A primordial viscosity contrast originating from a factor of ∼4 to ∼250 times lower H 2 O concentration in the plume mantle compared with the upper mantle may explain (a) why giant impacts that triggered whole mantle magma oceans did not homogenize the growing planet, (b) why the plume mantle has experienced less processing by partial melting over Earth’s history, and (c) how early-formed isotopic heterogeneities may have survived ∼4.5 Gy of solid-state mantle convection.

58 GEOSCIENCES↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)

We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.

Shen, Steve D.↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Hawaii Play Fairway Analysis: Noble Gas Raw Data for Hawaii, Maui, Oahu, Kauai, and Lanai islands

Noble gas raw data for the Hawaiian islands of Big Island, Maui, Oahu, Lanai, and Kauai. Based on results from prior phases of the Hawaii Play Fairway Analysis, this project targeted 66 wells on the islands of Hawaii, Maui, Lanai, Oahu, and Kauai for sampling of dissolved noble gases, trace metals, common ions, and the stable isotopes 2H and 18O. Ultimately, 23 of the 66 well targets were sampled. Noble gas data from this study is supplemented with data shared by the United States Geologic Survey for the summit of Kilauea, and by the geothermal energy company Ormat Technologies Inc. for their geothermal power plant Puna Geothermal Venture on the Lower East Rift of Kilauea, and for their exploration of Kona and Hualalai on Hawaii, as well as the Southwest Rift of Haleakala on Maui. The noble gas helium is used as an indicator of geothermal heat when excess 3He and/or 4He is present when compared to the atmospheric ratio of those isotopes (R/Ra). R/Ra is minimally affected by dilution and transport, allowing even those wells not perfectly situated over a geothermal system to indicate a geothermal anomaly. R/Ra anomalies are present on every island in this study. There is a strong correlation between R/Ra anomalies and proximity to rift zones and calderas. The Hawaii Play Fairway project was funded by the U.S. Department of Energy Geothermal Technologies Office (award DE-EE0006729). For more information, see Colin Ferguson's Master of Science thesis "Exploration for Blind Geothermal Resources in the State of Hawaii Utilizing Dissolved Noble Gasses in Well Waters."

15 GEOTHERMAL ENERGY↗

Analysis and prediction of reaction kinetics using the degree of rate control

“Degree of rate control” (DRC) analysis provides a quantitative approach for analysing the kinetics of multi-step reaction mechanisms that has been widely applied to both heterogeneous and homogeneous catalysis research, as well as electrocatalysis. The DRC of any given transition state or intermediate is defined as a partial derivative such that it approximately equals the fractional increase in net rate to the product of interest per differential decrease in its standard-state free energy for that species (÷RT), holding constant the standard-state free energies of all other transition states and intermediates. Even very complex mechanisms usually have only a few species with non-zero DRCs and are thus the species whose interactions with the catalyst most strongly affect the net rate. These key DRC values thus offer a simple and intuitive route to optimize catalyst materials, especially with the assistance of computational methods like density functional theory (DFT). These high-DRC species are also the species whose energetics must be most accurately measured or calculated to achieve an accurate kinetic model for any reaction mechanism. In simple cases with a single “rate-determining step”, the DRC for its transition state (TS) is + 1. Catalyst-bound intermediates, on the other hand, often have negative DRCs equal to a small integer times their fractional occupancy of catalyst sites. The apparent activation energy equals a weighted average of the standard-state enthalpies (relative to reactants) of all the species (intermediates, transition states and products) in the reaction mechanism, each weighted by its DRC (+RT). It has been shown that the apparent transfer coefficient in electrocatalysis, an inverted form of the Tafel slope, is a weighted average of the number of electrons transferred to generate each intermediate or product species in the mechanism, weighted again by the DRC. Quantitative analysis of kinetic isotope effects (KIEs, or the ratio of net rates for different reactant isotopes) in complex mechanisms has shown that the logarithm of the KIE equals the weighted average over all species in the mechanism of the difference between the two isotopes in their standard-state free energies (÷RT), again weighted by the DRC. The reaction orders with respect to fluid-phase concentrations of reactants, products and intermediates have also been proven to be directly related to DRCs. Thus, there are numerous experimental observables which equate to short linear combinations of DRCs, so that combinations of experimental measurements might provide access to DRC values. Since its invention for transition states in 1994 and its generalization to include intermediates in 2009, the DRC has thus far mainly been calculated for microkinetic models based either entirely on DFT or on DFT with the key energies (i.e., those for high-DRC species) being fine-tuned to match experiments. The relationships summarized in this work provide new opportunities for using experiments earlier in the development and optimization of microkinetic models that require input from computational catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The gallium isotopic composition of the Moon

Here, in this study, we present new Ga isotope data from a suite of 28 mare basalts and lunar highland rocks. The δ 71 Ga values of these samples range from -0.10 to +0.66‰ (where δ 71 Ga is the relative difference between the 71 Ga/ 69 Ga ratio of a sample and the Ga-IPGP standard), which is an order of magnitude more heterogeneous than δ 71 Ga values in terrestrial magmatic rocks. The cause of this isotopic heterogeneity must be established to estimate the bulk δ 71 Ga value of the Moon. In general, low-Ti basalts and ferroan anorthosite suite (FAS) rocks have δ 71 Ga values that are lower than high-Ti basalts and KREEP-rich rocks. The observation that rocks derived from later forming LMO cumulates have higher δ 71 Ga values suggests that Ga isotopes are fractionated by processes that operate within the chemically evolving LMO, rather than localized degassing or volatile redistribution. Correlations between indices of plagioclase removal from the LMO (e.g. Eu/Eu*) with Ga isotope ratios suggest that a Δ 71 Ga plagioclase-melt of -0.3‰, (where Δ 71 Ga plagioclase-melt is the isotopic fractionation associated with crystallization of plagioclase from a melt), could drive the observed isotopic fractionation in high-Ti mare basalts and KREEP-rich rocks. This would be consistent with the observation that FAS rocks have δ 71 Ga values that are lower than mare basalts. However, the addition of KREEP-like material into the mare basalt source regions would not contribute enough Ga to perturb the isotopic composition outside of analytical uncertainty. Thus, basalts derived from early formed LMO cumulates such as those from Apollo 15, would preserve light Ga isotopic compositions despite containing modest amounts of urKREEP. We estimate that the δ 71 Ga value of the LMO was ~0.14‰ prior to the onset of plagioclase crystallization and extraction. Whether this δ 71 Ga value is representative of the initial BSM cannot be ascertained from the current dataset. It remains plausible that the Moon accreted with a heavier Ga isotopic composition than the Earth. Alternatively, the Moon and Earth could have accreted with similar isotopic compositions (BSE = 0.00 ± 0.06‰, Kato et al., 2017) and volatile loss drove the LMO to higher δ 71 Ga values prior to formation of the lunar crust.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes

Here, the microextraction sampling technique was integrated with triple quadrupole–inductively coupled plasma–mass spectrometry (TQ–ICP–MS) to directly sample and measure the isotopic compositions of uranium (U) and plutonium (Pu) from cotton swipes. Once extracted, the U/Pu were directed into the TQ–ICP–MS instrument for isotopic determination. Carbon dioxide (CO 2 ) and helium (He) gases were delivered to a collision reaction cell within the ICP–MS system for ion separation. The CO 2 reacts with the U + forming UO + which is ultimately separated from the Pu + ions of interest in the third quadrupole. This study demonstrates direct liquid extraction of U/Pu from a solid surface and subsequent measurement by TQ–ICP–MS in <60 s. Flow rates were optimized (0.3 mL min –1 CO 2 and 5 mL min –1 He) in the reaction cell of the ICP–MS system to maximize the Pu signal while minimizing U interferences (i.e., 238 U + tail and 238 UH + ) at m/z 239. Low levels of Pu (~2 pg) were deposited on a cotton swipe along with U at concentrations ranging from 20 to 200 ng. The 240 Pu/ 239 Pu ratio was measured with <7% relative difference from the certified value at all U concentrations. Major and minor U isotope ratios were also measured with <4% relative difference. This highlights that the microextraction–TQ–ICP–MS method can extract a mixed U/Pu sample directly from a cotton swipe and measure both isotopic systems without chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the provenance of GEMS, a quarter century post discovery

The provenance of GEMS (glass with embedded metal and sulfides) in cometary type interplanetary dust particles is investigated using analytical scanning transmission electron microscopy and secondary ion mass spectrometry. We review the current state of knowledge and closely examine the densities, elemental compositions and distributions, iron oxidation states, and isotopic compositions of a subset of GEMS in chondritic porous interplanetary dust. We find that GEMS are underdense with estimated densities that are 35–65% of compositionally equivalent crystalline aggregates. GEMS low densities result in a lower contribution to the bulk compositions of IDPs than has been assumed based on their volume fraction. We also find that element/Si ratios, assumed to be primary (indigenous), are instead perturbed by contamination and secondary alteration, including pulse heating during atmospheric entry. Fe in pyrrhotite inclusions was oxidized and Mg, S, Ca, and Fe were depleted relative to lithophile Al and Si, resulting in reduction in element/Si ratios. Because they trap outgassing elements, Fe-rich oxide rims that formed on the surface of GEMS are serendipitous “witness plates” to the changes in composition that accompany atmospheric entry. As a result of alteration, GEMS elemental compositions cannot reliably inform about their provenance. Except for highly anomalous oxygen isotope ratios measured in some large GEMS grains that indicate a contribution from circumstellar dust, oxygen isotope compositions are generally poor indicators of provenance. Prior work indicates that most GEMS fall close to the terrestrial oxygen isotope composition, which, however, does not exclude a presolar interstellar origin. Nitrogen isotopic compositions are more diagnostic. Elevated 15 N/ 14 N ratios indicate that GEMS accreted in conjunction with formation of organic matter by ion–molecule reactions in a cold (<50 K) presolar environment like the extreme outer nebula or interstellar medium. Considering all observations, we conclude that GEMS are most likely processed interstellar silicates.

79 ASTRONOMY AND ASTROPHYSICS↗

Plutonium Signatures in Molten-Salt Reactor Off-Gas Tank and Safeguards Considerations

Fluid-fueled molten-salt reactors (MSRs) are actively being developed by several companies, with plans to deploy them internationally. The current IAEA inspection tools are largely incompatible with the unique design features of liquid fuel MSRs (e.g., the complex fuel chemistry, circulating fuel inventory, bulk accountancy, and high radiation environment). For these reasons, safeguards for MSRs are seen as challenging and require the development of new techniques. This paper proposes one such technique through the observation of the reactor’s off-gas. Any reactor design using low-enriched uranium will build up plutonium as the fuel undergoes burnup. Plutonium has different fission product yields than uranium. Therefore, a shift in fission product production is expected with fuel evolution. The passive removal of certain gaseous fission products to the off-gas tank of an MSR provides a valuable opportunity for analysis without significant modifications to the design of the system. Uniquely, due to the gaseous nature of the isotopes, beta particle emissions are available for observation. The ratios of these fission product isotopes can, thus, be traced back to the relative amount and types of fissile isotopes in the core. This proposed technique represents an effective safeguards tool for bulk accountancy which, while avoiding being onerous, could be used in concert with other techniques to meet the IAEA’s timeliness goals for the detection of a diversion.

Dunkle, Nicholas (ORCID:000000027323011X)↗

Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recovery of Neptunium-236g from Photon and Proton-Irradiated Actinide Targets

Neptunium-236g is a rare radionuclide used as a tracer for neptunium-237 analyses. The availability of 236gNp is limited and the viable production routes are costly, time consuming, and only produce trace quantities of the desired product. For this work, two known production methods were tested to determine product recovery, purity, and viability for use as a tracer. The first method utilizes a photon-irradiated 237Np target to produce 236gNp by the 237Np(?,n)?236Np reaction. The second method utilizes the 238U(d,4n) ?236Np reaction. These production routes were evaluated previously, and the former was considered ineffective without isotope separation and the latter was not well-characterized for the 236mNp/236gNp production ratio. Recent resurgence of electromagnetic isotope separation technology has enabled at least partial recovery of 236gNp from part-per-million abundance feeds produced by the photonuclear reaction. To address the lack of production data for the second method, a deuteron-irradiated depleted uranium target was chemically processed to recover and purify the Np for abundance and ratio analyses. The status and current analytical results for each production method are presented.

07 ISOTOPE AND RADIATION SOURCES↗

Fission Product Quantification and Burnup Analysis via Gamma Spectrometry of the AGR-5/6/7 TRISO Fuel Experiment

Five capsules containing varying configurations of TRISO fuel compacts were irradiated in the most recent Advanced Gas Reactor (AGR) TRISO test campaign, AGR-5/6/7. As part of the post-irradiation examination (PIE) of this work all the fuel compacts and capsule graphite holders were measured with the Precision Gamma Scanner (PGS) to determine isotopic activities and locations using gamma spectrometry. Measuring the compacts allowed for the comparison of physics model depletion calculations with the measured compact activity to validate models. These measurements also are used to find compacts of interest with low fission product retention that may be tested in subsequent PIE. Measurements of the holders can confirm fission product distribution and migration. Of the isotopes measured, Cs-137 and Cs-134 were used to estimate location of failed particles as well as determine a measured burnup estimation. Results from Capsule 1 compacts and the holder indicate many fuel particle failures occurred. There are high amounts of cesium in the holder near Stack 9 of Capsule 1 that corresponds to low fractions?measured-to-calculated (M/C) ratio?of cesium remaining in those compacts. All other capsules had cesium retention ratios near 1. The isotope 110mAg had less consistent results. Capsule 2 compacts exhibited a M/C of 0.20, much lower than anticipated for the temperatures these compacts underwent. Capsule 3 experienced much higher temperatures, >1300C and had an average M/C of 0.75. These are the opposite results than what was predicted by past AGR experiments for the relationship between temperature and isotope retention. Capsule 4 and 5 showed good fission product retention and agreement with the physics model predictions. The burnup results from the PGS measurements showed strong agreement between the physics models and the measured values. Using a ratio of Cs-134/Cs-137 to calculate the burnup match closely with the physics models. Additionally, the Cs-137 burnup results were less accurate but extremely close to the model results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Timing of Potential Last Nucleosynthetic Injections into the Protosolar Molecular Cloud Inferred from 41 Ca– 26 Al Systematics of Bulk CAIs

Short-lived radionuclides (SLRs) provide important information about the chronology of the early solar system. Among them, 41 Ca, due to its decay to 41 K with a half-life of only 0.1 Ma, is particularly valuable in constraining the timescales and origins of both SLRs and the formation of the oldest solar system materials, the Ca–Al-rich inclusions (CAIs). The initial abundance of 41Ca in the solar system, expressed as the ( 41 Ca/ 40 Ca)I ratio, is the key to unveiling the origin of this nuclide. Here, we report a new solar system ( 41 Ca/ 40 Ca)I ratio of 2.0 × 10 −8 derived from the K isotope compositions of two CAIs. This new ratio is about four times higher than the previous value inferred from a mineral isochron. Such a high ( 41 Ca/ 40 Ca)I ratio in the CAIs exceeds that expected for the protosolar molecular cloud by ∼1000×, implying very late injection of the 41 Ca (and possibly other SLRs) into the protosolar molecular cloud. The correlated enrichments of 41 Ca and 26 Al in the bulk CAI samples hint at a common stellar origin of both SLRs. The injection time estimated from our new data depends on the stellar source—it ranges from 0.6 Ma for a Wolf–Rayet wind to 1.0 Ma for a TP-AGB star ejecta.

79 ASTRONOMY AND ASTROPHYSICS↗