Search NASA⌕ Search

SEARCH · Search NASA

Results for “Long-duration missions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight

OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

Parabolic Flight↗

Technology Readiness Assessment for Stirling Power Convertor

Stirling-based power conversion system could represent a critical enabling technology for future NASA missions, offering significantly enhanced power efficiency over traditional thermoelectric systems. To ensure the successful infusion of this technology into deep space and planetary surface missions, a rigorous evaluation of its maturity and associated risks is essential. The objective of this Technology Readiness Assessment (TRA) is to determine the current technology readiness level (TRL) of the Stirling power convertor and identify key technical risks and challenges associated with its maturation and potential infusion into a targeted flight system. The evaluation process will rigorously follow the NASA TRA procedure: (1) determining the requirements that underpin the design, function, and performance; (2) finding and listing all new technology elements (NTEs) and critical technology elements (CTEs); (3) identifying the level of integration assumed for the assessment; and (4) assessing the TRL for each NTE and CTE. The overall subassembly TRL will then be determined via a roll-up using the “weakest link” criterion, culminating in a final (5) assessment of risks to further progression of maturity. This paper will present the results of a comprehensive technology readiness assessment (TRA) conducted on the Stirling-based dynamic power conversion subassembly, excluding the radioisotope heat source. The paper will also describe a detailed breakdown of the TRL roll-up and a matrix of identified risks and recommended mitigation paths, along with identified key technical risks and challenges to achieve the required long-duration performance. Key Words: Radioisotope Power Conversion, Technology Readiness Assessment

Radioisotope Power Conversion↗

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell↗

A Faster-Than-Real-Time Framework for Reliability-Oriented Simulation of PV Inverters

Physics-of-Failure (PoF) based reliability assessment for photovoltaic (PV) inverters requires long-duration electrical and electrothermal stress histories, yet generating such stress histories with high-fidelity switching models over year long mission profiles is computationally prohibitive. Conventional methods either sacrifice modeling fidelity for speed or require runtimes that are impractical for design iteration and uncertainty studies. To address this bottleneck, this paper presents a High-Performance Computing (HPC) based simulation frame work for faster-than-real-time reliability-oriented simulation. The proposed framework integrates the Average-to-Switching (A2S) method with parallel computing techniques to accelerate switching-level waveform reconstruction. We further introduce optimization strategies, including cluster merging and sensitivity based mission profile screening, to reduce the computational burden. Evaluated using real-world mission profile inputs and a MATLAB/Simulink switching-model reference, the framework reduces the simulation time for a one-year mission from an intractable multi-year duration to approximately 7.3 minutes while maintaining low waveform error. This acceleration provides a practical reliability-oriented simulation engine that can be coupled with component-specific aging models for subsequent PV inverter PoF assessment.

High-performance Computing↗

Introduction to Long-Duration Exposure Facility

A description of the structure and uses of the Long Duration Exposure Facility (LDEF) is given. The LDEF was designed to provide a large number of economical opportunities for science and technology experiments that require modest electrical power and data processing while in space and which benefit from postflight laboratory investigations with the retrieved experiment hardware. Like the Shuttle, the LDEF is reusable, and repeat missions are planned, each with a new complement of experiments. The LDEF is essentially a free-flying cylindrical structure. The experiments on LDEF are totally self-contained in trays mounted on the exterior of the structure. LDEF can accommodate 86 experiment trays, 72 around the circumference and 14 on the two ends. The LDEF is delivered to Earth orbit by the Shuttle. In orbit, the Shuttle remote manipulator system removes the LDEF from the Shuttle payload bay and places it in a gravity-gradient-stabilized attitude. After an extended period in orbit, which is set by experiment requirements, the LDEF is retrieved on a subsequent Shuttle flight.

Kinard, W. H.↗

High-resolution X-ray spectra of solar flares. VII - A long-duration X-ray flare associated with a coronal mass ejection

It has been recognized that very long duration X-ray events (lasting several hours) are frequently associated with coronal mass ejection. Thus, Sheeley et al. (1983) found that the probability of the occurrence of a coronal mass ejection (CME) increases monotonically with the X-ray event duration time. It is pointed out that the association of long-duration, or long-decay, X-ray events (LDEs) with CMEs was first recognized from analysis of solar images obtained by the X-ray telescopes on Skylab and the Naval Research Laboratory (NRL) slitless spectroheliograph. Recently high-resolution Bragg crystal X-ray spectrometers have been flown on three spacecraft, including the Department of Defense P78-1 spacecraft, the NASA Solar Maximum Mission (SMM), and the Japanese Hinotori spacecraft. In the present paper, P78-1 X-ray spectra of an LDE which had its origin behind the solar west limb on November 14, 1980 is presented. The obtained data make it possible to estimate temperatures of the hottest portion of the magnetic loops in which the emission arises.

Kreplin, R. W.↗

Microgravity research in the era of Space Station Freedom

NASA has developed numerous microgravity research-related missions planned for the period of 1991 to 1994, leading to Space Station Freedom (SSF). Space Transportation System (STS) flights are designed with the philosophy that STS, Spacelab, and SSF will constitute an integrated system allowing an evolutionary approach to microgravity research in low earth orbit. Ground experiments, tested and refined on short-duration STS flights, will be developed and deployed on SSF where long-duration operation is required. In addition, this sequence will ensure maximum scientific return, encourage growth of the research community, and increase the chances of identifying new techniques and processes to be used in the SSF time frame. The paper discusses the rationale, justification, and approach taken by NASA to fully exploit this environment.

Lee, Mark C.↗

EMI testing adequacy and flight anomaly history

The effects of electromagnetic interference (EMI) and the space environment on the performance of long-duration spacecraft hardware are surveyed, and the implications for prelaunch test procedures are indicated. Topics addressed include the need for onboard environmental monitoring devices to aid in the identification of environmentally induced anomalies, environmental modeling methods, the existing spacecraft-anomaly data bases, electrostatic discharges, radiation effects, magnetic-field effects, and terrestrial sources of EMI. Statistical data on EMI-induced anomalies are presented in graphs and discussed in detail. It is recommended that testing beyond the current MIL-STD levels be performed on equipment for long-term missions such as the Space Station.

Kuberry, Richard W.↗

Toxicological implications of extended space flights

This paper draws attention to the needs and mechanisms for shielding crewmembers on long-duration space flights from hazards related to chemical toxicants. Specific attention is given to existing data on sources of impaired performance, namely, neurotoxicants, respiratory infections, pulmonary function. The behavioral effects associated with long-term exposure to volatile organic solvents can impair crucial functional parameters of space flight and mission objectives. Respiratory infections contribute to performance decrements of up to 20 percent, and pulmonary function can be impaired by contaminants such as ozone leading to reduced performance. It is concluded that these and other sources of toxicologically induced performance reductions be studied since they impinge on vehicle design and mission objectives.

Weiss, Bernard↗

An interim overview of LDEF materials findings

The flight and retrieval of the National Aeronautics and Space Administration's Long Duration Exposure Facility (LDEF) provided an opportunity for the study of the low-Earth orbit (LEO) environment and long-duration space environmental effects (SEE) on materials that is unparalleled in the history of the U.S. Space Program. The remarkable flight attitude stability of LDEF enables specific analyses of various individual and combined effects of LEO environmental parameters on identical materials on the same space vehicle. This paper provides an overview of the interim LDEF materials findings of the Principal Investigators and the Materials Special Investigation Group. In general, the LDEF data is remarkably consistent; LDEF will provide a 'benchmark' for materials design data bases for satellites in low-Earth orbit. Some materials were identified to be encouragingly resistant to LEO SEE for 5.8 years; other 'space qualified' materials displayed significant environmental degradation. Molecular contamination was widespread; LDEF offers an unprecedented opportunity to provide a unified perspective of unmanned LEO spacecraft contamination mechanisms. New material development requirements for long-term LEO missions have been identified and current ground simulation testing methods/data for new, durable materials concepts can be validated with LDEF results. LDEF findings are already being integrated into the design of Space Station Freedom.

Stein, Brad A.↗

Latent Viruses: A Space Travel Hazard??

A major issue associated with long-duration space flight is the possibility of infectious disease causing an unacceptable medical risk to crew members. Our proposal is designed to gain information that addresses several issues outlined in the Immunology/Infectious disease critical path. The major hypothesis addressed is that space flight causes alterations in the immune system that may allow latent viruses which are endogenous in the human population to reactivate and shed to higher levels than normal which can affect the health of crew members during a long term space-flight mission. We will initially focus our studies on the human herpesviruses and human polyomaviruses which are important pathogens known to establish latent infections in the human population. Both primary infection and reactivation from latent infection with this group of viruses can cause a variety of illnesses that result in morbidity and occasionally mortality of infected individuals. Effective vaccines exist for only one of the eight known human herpesviruses and the vaccine itself can still reactivate from latent infection. Available antivirals are of limited use and are effective against only a few of the human herpesviruses. Although most individuals display little if any clinical consequences from latent infection, events which alter immune function such as immunosuppressive therapy following solid organ transplantation are known to increase the risk of developing complications as a result of latent virus reactivation. This proposal will measure both the frequency and magnitude of viral shedding and genome loads in the blood from humans participating in activities that serve as ground based models of space flight conditions. Our initial goal is to develop sensitive quantitative competitive PCR- based assays (QC-PCR) to detect the herpesvirus Epstein-Barr virus (EBV), and the polyomaviruses SV40, BKV, and JCV. Using these assays we will establish baseline patterns of viral genome load in the blood and viral shedding from normal volunteers in a longitudinal study over I year in length. As a comparison, we will measure patterns of viral genome loads and shedding from individuals who are severely immunosuppressed, in whom herpesvirus reactivation or primary infection with a herpesvirus is known to cause complications. In addition, we will proceed to testing ground based analogs in collaboration with Dr. Duane Pierson (Lyndon B. Johnson Space Center). This will include measuring samples obtained from individuals living and working in the extreme environment of Antarctica. We expect to detect viral shedding or reactivation from most of the test groups, although the magnitude of shedding or reactivation cannot be predicted. The data accumulated from studies in this proposal should allow us to evaluate whether events that simulate certain aspects of space flight reactivate viral infections severe enough in nature that they may compromise the success of long-term space flight missions. These studies will also provide a foundation to monitor viral reactivation and shedding from crew members participating in actual space flight missions. We will present data showing the establishment of our QC-PCR assay for detection of EBV.

Ling, P. D.↗

Temperature Regulation in Crewmembers After a 115-Day Space Flight

Impaired thermoregulation, which has been observed during exercise following bed rest, may significantly impact crewmembers during space flight operations by decreasing exercise capacity and orthostatic tolerance. Impaired temperature regulation would cause higher levels of core temperature, due to an attenuated cutaneous vasodilatory reflex and sweating response, for a given oxygen consumption. Two mate crewmembers of the Mir 18 mission performed supine cycle exercise se (20 min @ 40% and 20 min @ 65% preflight VO2pk) 145 days preflight and 5 days postflight. Core temperature (Tcore) was measured by an ingestible telemetry pill, skin blood flow (SBF) by laser Doppler velocimetry, and sweat rate (SR) by dew point hygrometry. Tcore at the time of test termination was similar (37.8 C) for both subjects before and after flight despite a shorter test duration (40 vs 28-29 minutes) postflight. The slopes of the SBF/Tcore relationship (Subj 1: 396 vs 214; Subj 2: 704 vs 143 Perfusion Unit/degC) and SR/Tcore relationship (Subj 1: 4.5 vs 2.1; Subj 2: 11.0 vs 3.6mg/min/sq cm/degC) were reduced postflight. Tcore thresholds for both SR (Subj 1: 37.4 vs 37.6; Subj 2: 37.6 vs 37.6 C) and SBF (Subj 1: 37.3 vs 37.5; Subj 2: 37.6 vs 37.7 C) were similar pre- to postflight. For these 2 crewmembers, it appeared that thermoregulation during exercise was impaired as evidenced by compromised heat loss responses after long-duration space flight.

Lee, S. M. C.↗

Physiological Adaptations and Countermeasures Associated with Long-Duration Space Flights

On earth, the presence of gravity imposes weight-bearing gradients on tissues which influence the functions of multiple integrative systems. On the other hand, conditions of actual or simulated microgravity can modify and/or nullify these gradients and subsequently alter structure and function. The purpose of this symposium is to discuss the results from short-term Shuttle flights, long term Skylab or Mir missions, or long-term ground based experiments which indicate or suggest that performance has been or could be compromised in space missions of long durations (>one year) or with space tasks (e.g. building space stations) with the goal of identifying countermeasures that could minimize or eliminate the expected anatomical and physiological consequences. After an overview by C. Tipton from the U. Arizona, the countermeasures necessary for the fluid shifts and select functions of the cardiovascular system will be discussed by A. Hargens from NASA Ames Research Center. He will be followed by K. Baldwin of the U. California at Irvine who will discuss the countermeasures needed to prevent the changes that alter the structure, function and control of skeletal muscles. Since changes in bone mass with microgravity are a major concern of NASA, V. Schneider from NASA Headquarters will present data and the countermeasures for bone. Although the results are limited, the changes in the endocrine and immune system deserve mentioning and C. Tipton will assume this responsibility. V. Convertino from the Air Force School of Aerospace Medicine has the challenge of discussing the role, importance, and the specificity of exercise as an effective countermeasure while I. Kozlovskaya from Moscow will elaborate on the Russian experiences with past countermeasures and provide a viewpoint on future ones. After the brief (25 min.) presentations, the speakers will assemble as a panel to discuss the issues raised and the concerns of the audience.

Tipton, C. M.↗

Controlling Electron Backstreaming Phenomena Through the Use of a Transverse Magnetic Field

DEEP-SPACE mission propulsion requirements can be satisfied by the use of high specific impulse systems such as ion thrusters. For such missions. however. the ion thruster will be required to provide thrust for long periods of time. To meet the long operation time and high-propellant throughput requirements, thruster lifetime must be increased. In general, potential ion thruster failure mechanisms associated with long-duration thrusting can be grouped into four areas: (1) ion optics failure; (2) discharge cathode failure; (3) neutralizer failure; and (4) electron backstreaming caused by accelerator grid aperture enlargement brought on by accelerator grid erosion. The work presented here focuses on electron backstreaming. which occurs when the potential at the center of an accelerator grid aperture is insufficient to prevent the backflow of electrons into the ion thruster. The likelihood of this occurring depends on ion source operation time. plasma density, and grid voltages, as accelerator grid apertures enlarge as a result of erosion. Electrons that enter the gap between the high-voltage screen and accelerator grids are accelerated to the energies approximately equal to the beam voltage. This energetic electron beam (typically higher than 1 kV) can damage not only the ion source discharge cathode assembly. but also any of the discharge surfaces upstream of the ion acceleration optics that the electrons happen to impact. Indeed. past backstreaming studies have shown that near the backstreaming limit, which corresponds to the absolute value of the accelerator grid voltage below which electrons can backflow into the thruster, there is a rather sharp rise in temperature at structures such as the cathode keeper electrode. In this respect operation at accelerator grid voltages near the backstreaming limit is avoided. Generally speaking, electron backstreaming is prevented by operating the accelerator grid at a sufficiently negative voltage to ensure a sufficiently negative aperture center potential. This approach can provide the necessary margin assuming an expected aperture enlargement. Operation at very negative accelerator grid voltages, however, enhances ion charge-exchange and direct impingement erosion of the accelerator grid. The focus of the work presented here is the mitigation of electron backstreaming by the use of a magnetic field. The presence of a magnetic field oriented perpendicular to the thruster axis can significantly decrease the magnitude of the backflowing electron current by significantly reducing the electron diffusion coefficient. Negative ion sources utilize this principle to reduce the fraction of electrons in the negative ion beam. The focus of these efforts has been on the attenuation of electron current diffusing from the discharge plasma into the negative ion extraction optics by placing the transverse magnetic field upstream of the extraction electrodes. In contrast. in the case of positive ion sources such as ion thrusters, the approach taken in the work presented here is to apply the transverse field downstream of the ion extraction system so as to prevent electrons from flowing back into the source. It was found in the work presented here that the magnetic field also reduces the absolute value of the electron backstreaming limit voltage. In this respect. the applied transverse magnetic field provides two mechanisms for electron backstreaming mitigation: (1) electron current attenuation and (2) backstreaming limit voltage shift. Such a shift to less negative voltages can lead to reduced accelerator grid erosion rates.

Foster, John E.↗

Orientation and movement in unusual force environments

A manned space mission to Mars might take as long as 1 year each way. Consequently, artificial gravity is being considered as a way of preventing the debilitating effects of long-duration exposure to microgravity on the human body. The present article discusses some of the problems associated with adapting to the rotation levels that might be used to generate artificial gravity. It also describes how exposure to background-force levels greater or less than the 1-G force of Earth gravity affects orientation and movement control. The primary emphasis of the article is that human movement and orientation control are dynamically adapted to the 1-G force background of Earth and that accommodation to altered force levels or to rotating environments requires a wide range of adaptive changes.

Parabolic Flight↗

Computer simulation analysis of the effects of countermeasures for reentry orthostatic intolerance

Fluid loading is a countermeasure currently in routine use to improve the g-tolerance of crewmembers during reentry and return of Shuttle flights. However, its effectiveness diminishes with mission duration. Countermeasures that will be effective on long-duration flights are needed and are presently under development. This paper discusses the application of computer simulation in the analysis of the effects of countermeasures for reentry orthostatic intolerance. The results suggest improvements upon the fluid loading countermeasure currently in use.

NASA Center JSC↗

The DS1 hyper-extended mission

The Primary Mission for Deep Space (DS1) was to demonstrate 12 new technologies one of which was the Ion Propulsion System (IPS). After successfully completing its primary mission, DS1 was given a new mission. The objective of this Extended Mission was to fly by the Comet Borrelly. After the successful Borrelly encounter, the ion thruster on DS1 had to be operated for more than 14,000 hours in space. This provided a unique opportunity to investigate the condition of the thruster after long-term operation in space and determine, to the extent possible, if the thruster wear in space is consistent with that observed in long-duration ground tests.

DS1 Deep Space 1 ion propulsion ion thruster↗

Microbiological Contamination of Spacecraft

The International Space Station (ISS) Phase1 Program resulted in seven US astronauts residing aboard the Russian Space Station Mir between March 1995 and May 1998. Collaboration between U.S. and Russian scientists consisted of collection and analyses of samples from the crewmembers and the Mir and Shuttle environments before, during, and after missions that lasted from 75 to 209 days in duration. The effects of long-duration space flight on the microbial characteristics of closed life support systems and the interactions of microbes with the spacecraft environment and crewmembers were investigated. Air samples were collected using a Russian or U.S.-supplied sampler (SAS, RCS, or Burkard,) while surface samples were collected using contact slides (Hycon) or swabs. Mir recycled condensate and stored potable water sources were analyzed using the U.S.-supplied Water Experiment Kit. In-flight analysis consisted of enumeration of levels of bacteria and fungi. Amounts of microorganisms seen in the air and on surfaces were mostly within acceptability lin1its; observed temporal fluctuations in levels of microbes probably reflect changes in environmental conditions (e.g., humidity). All Mir galley hot water samples were within the standards set for Mir and the ISS. Microbial isolates were returned to Earth for identification of bacterial and fungal isolates. Crew samples (nose, throat, skin, urine, and feces) were analyzed using methods approved for the medical evaluations of Shuttle flight crews. No significant changes in crew microbiota were found during space flight or upon return relative to preflight results. Dissemination of microbes between the crew and environment was demonstrated by D A fingerprinting. Some biodegradation of spacecraft materials was observed. Accumulation of condensate allowed for the recovery of a wide range of bacteria and fungi as well as some protozoa and dust mites.

Pierson, D. L.↗