Search NASA⌕ Search

SEARCH · Search NASA

Results for “Loop Heat Pipe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The enhanced capillary pumped loop flight experiment, a prototype of the EOS platform thermal control system

The CAPL shuttle flight experiment will provide micro-gravity verification of the prototype capillary pumped loop (CPL) thermal control system for EOS. The design of the experiment is discussed with particular emphasis on the new technology areas in ammonia two-phase reservoir design and heat pipe heat exchanger development. The thermal and hydrodynamic analysis techniques and results are also presented, including pressure losses, fluid flow, and on-orbit heat rejection capability. CAPL experiment results will be presented after the flight, currently planned for 1993.

Butler, D.↗

The Capillary Pumped Loop Flight Experiment (CAPL): A pathfinder for EOS

The CAPL shuttle flight experiment will provide microgravity verification of the prototype capillary pumped loop (CPL) thermal control system for EOS. The design of the experiment is discussed with particular emphasis on the new technology areas in ammonia two-phase reservior design and heat pipe heat exchanger development. The thermal and hydrodynamic analysis techniques and results are also presented, including pressure losses, fluid flow, and non-orbit heat rejection capability. CAPL experiment results will be presented after the flight, presently planned for 1993.

Butler, D.↗

Hardware Progress Made in the Early Flight Fission Test Facilities (EFF-TF) To Support Near-Term Space Fission Systems

The EFF-TF provides a facility to experimentally evaluate thermal hydraulic issues through the use of highly effective non-nuclear testing. These techniques provide a rapid, more cost effective method of evaluating designs and support development risk mitigation when concerns are associated with non-nuclear aspects of space nuclear systems. For many systems, electrical resistance thermal simulators can be used to closely mimic the heat deposition of the fission process, providing axial and radial profiles. A number of experimental and design programs were underway in 2004. Initial evaluation of the SAFE-100a (19 module stainless steel/sodium heat pipe reactor with integral gas neat exchanger) was performed with tests up to 17.5 kW of input power at core temperatures of 1000 K. A stainless steel sodium SAFE-100 heat pipe module was placed through repeated freeze/thaw cyclic testing accumulating over 200 restarts to a temperature of 1000 K. Additionally, the design of a 37-fuel pin stainless steel pumped sodium/potassium (NaK) loop was finalized and components procured. Ongoing testing at the EFF-TF is geared towards facilitating both research and development necessary to field a near term space nuclear system. Efforts are coordinated with DOE laboratories, industry, universities, and other NASA centers. This paper describes some of the 2004 efforts.

VanDyke, Melissa↗

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

Getter Capsules for Heat-Transport Systems

Metal absorbs hydrogen dissolved in heat-transfer fluids. Blockages by hydrogen gas in refrigerators, heat pipes, and other two-phase heat-transport systems eliminated by use of degassing metals or alloys called getters. Getter contained in getter capsule placed in series or in parallel with heat-transport loop. Gas-removal technique more specific and more reliable in solving problem of gas blockage than older procedures.

Seidenberg, Benjamin↗

LOCA Analysis for the NIST Research Reactor

The research reactor (aka NBSR) at the National Institute of Standards and Technology (NIST) is a heavy water cooled, moderated, and reflected tank-type research reactor that operates at atmospheric pressure and a design power of 20 MW. Core power is generated in 30 fuel elements, each with 17 fuel plates in an upper section and a separate lower section. Power is removed using forced convection and heat exchangers in the cooling loop. The licensing analysis of the loss-of-coolant accident (LOCA) in the NBSR was addressed in the current Safety Analysis Report (SAR). The SAR discusses the low probability of a significant pipe break: 'the main piping is located in protected areas, system pressures are low, and flow rates are small so that wear is not an issue.' Therefore, the probability of a large break, including a double-ended guillotine break, is extremely low. For smaller breaks where the operator has time to take action, procedures are in place to 1) mitigate a loss of water by tripping pumps and closing control valves to isolate the reactor vessel after the falling water level in the vessel is detected by instrumentation, and 2) ensure that emergency cooling water continues to flow for as long as needed. The SAR also refers to an analysis of why there is sufficient water without forced cooling to cool the fuel elements (FEs) in a LOCA if the flow channels between two fuel plates (or a fuel plate and an outside plate) remain filled with water. That analysis was based on a flooding-limited critical power but assumed that reactor trip had taken place. A more recent study showed that some scenarios may lead to the draining of water from the coolant channels. In these cases, the cooling on the inside of the fuel element is from emergency cooling water that falls only along the inner surface of one of the side plates in the fuel elements; the remaining surfaces within the fuel element being exposed to gas. The analysis therein was done for both the present high-enriched uranium fuel (HEU) and the proposed low-enriched uranium fuel (LEU). The LOCA analyses done previously assumed that there is sufficient cooling during the short-term, i.e., before the water level reaches the top of the fuel plates and begins to drain from the coolant channels or before decay heat becomes low enough such that the flooding-limited critical power shows that there is no problem. The present study is to determine if that assumption is correct, i.e., to consider the situation immediately after the break, before and after reactor trip when the power is still relatively high.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura↗

Flight Testing of a Cryogenic Capillary Pumped Loop

Future space-based cryogenic systems will require enhanced integration flexibility, lower weight reduced parasitic penalties, better vibration isolation, and a variety of other improvements to meet performance goals. Additionally, there is an increasing need to locate cooling sources remotely from cooled components. In the past flexible conductive links were used and worked well in most cases. However, as the transport lengths increase, conductive couplings become heavier and less effective, and must be replaced by higher performance systems. One available option, which can meet many of these future requirements, is the cryogenic capillary pumped loop (CCPL). The development of the CCPL technology started in 1992, following the success of the room temperature CPLS. The extrapolation of CCPL technology to cryogenic temperatures offers many performance benefits, which are not currently within the reach of traditional heat pipes or conductive links. Specific advantages of the CCPL technology pertaining to cryocooler integration include: (1) greater capillary pumping pressure for improved ground testability; (2) improved mechanical isolation; (3) faster diode shutdown and lower reverse heat leaks; (4) tighter control of detector temperature; (5) variable or fixed conductance operation; and (6) ease of integration due to their flexibility. The applications of CCPL technology are numerous. Military and commercial applications include surveillance satellites, earth observing satellites, deep space observation systems, medical devices, and many other cryogenic systems. Over the past few years, several breadboard and prototype CCPLs have been built and ground tested. A prototype CCPL has demonstrated successful operation between 80K and 110K with heat loads between O.5W and 12W using nitrogen as the working fluid, and 35K and 40K with head loads of 0.25W to 3.5W using neon. In order to verify CCPL performance in a microgravity environment, a flight unit, CCPL-5, was tested onboard the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 under zero-G environment The CCPL could start from a supercritical condition in all tests, and the loop operating temperature could be tightly controlled regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with a heat load of 0.5W as well as with parasitic heat loads alone. There were no noticeable differences between zero-G and one-G operation.

Ku, Jentung↗

Advanced thermal control technology for commercial applications

A number of the technologies previously developed for the thermal control of spacecraft have found their way into commercial application. Specialized coatings and heat pipes are but two examples. The thermal control of current and future spacecraft is becoming increasingly more demanding, and a variety of new technologies are being developed to meet these needs. Closed two-phase loops are perceived to be the answer to many of the new requirements. All of these technologies are discussed, and their spacecraft and current terrestrial applications are summarized.

Swanson, Theodore D.↗

Preliminary Assessment of Additively Manufactured Cooling Channel Performance for Helium-Cooled Blanket Concepts

Sufficient cooling of the blanket first wall remains a critical challenge for the design and deployment of fusion power plants. Helium has been targeted as a potential blanket coolant due to its inertness and low neutron interactivity, among other advantages. However, the low thermal mass of helium creates a need for heat transfer enhancements in coolant channels to provide adequate cooling to the blanket’s first wall. Toward this end, a series of ribbed flow channels of various rib cross sections and configurations has been produced via additive manufacturing (AM) to study the efficacy of AM for first wall heat transfer enhancement and the optimization of heat transfer geometries. Helium cooling performance is studied in AM test articles at 4 MPa operating pressure, Reynolds numbers up to 197 000, and outer surface heat fluxes up to 42 kW/m 2 in the recently commissioned helium flow loop experiment (HFLE). Preliminary results of this study are presented herein. Heat transfer performance of nominally smooth (i.e., featureless) AM channels is quantified via measured Nusselt numbers and friction factors and compared to off-the-shelf smooth pipe experiments. Results are compared to existing correlations and used to discuss the effects of the AM processes on thermal-hydraulic performance. It is seen that the inherent roughness of the AM channels leads to an increase in both heat transfer coefficient and pressure drop when compared to the conventional pipe. In conclusion, recommendations are made for future studies based on these findings and additional considerations for the deployment of AM blanket cooling components.

36 MATERIALS SCIENCE↗

Advanced radiator systems for space power

Space power systems generating powers of 1 MWe and higher will require new approaches in radiator design in order to reject large waste heat loads without the unmanageable weight burden of conventional pumped-loop radiator systems. This paper discusses recent design concepts for radiator systems which have the potential for reducing radiator mass by as much as an order of magnitude below the mass of conventional systems. These advanced concepts, including the heat pipe radiator, particle (dust and droplet) radiators, moving belt radiator, rotating membrane radiator, and several interesting variations of these, achieve low mass by reducing the armor requirement for protection against micrometeoroids. The design and performance of each of these concepts is discussed, along with technical issues which must be addressed to bring these concepts to fruition.

Mattick, A. T.↗

Thermal Response Testing Takes a Step Forward

Oak Ridge National Labs has independently confirmed the accuracy of a new breakthrough Advanced Thermal Response Test (TRT) method that it claims “uses less than half of the test time, allows for a fluctuating or interruptible heat flux, performs quality validation of a GHEX installation, and yields new insights into ground thermal conductivity that warrant further research.” The new Advanced TRT approach will reduce costs and, for the first time, also determine the actual thermal conductivity of grout as it is installed. As everyone in the ground source heat pump (GSHP) industry knows, assuring the quality of the grout job of a ground heat exchanger (GHEX) is an especially vexing problem. Unless one is standing at the borehole head the entire time grouting is underway, they basically have no idea how good or bad the grouting job is or even if the loop pipe itself is installed correctly. This problem has been further brought to light with formal third party grout reports confirming that grout had been poured from the surface and that many loops were shorter than the specified depth in several projects

58 GEOSCIENCES↗

Transient performance of accident tolerant fuel in design basis accidents

A set of transient analysis has been performed to assess the performance of candidate accident tolerant fuel (ATF) against reference UO{sub 2} fuel with Zircaloy cladding under design basis accident (DBA) conditions. This study examined two ATF options, U{sub 3}Si{sub 2} fuel with SiC cladding and UO{sub 2} fuel with APMT cladding. The accident analyses were conducted using the system code TRACE for a three-loop PWR plant. PARCS standalone full-core calculations were done for each fuel/cladding combination to provide inputs to the TRACE point-kinetics model. The design basis accidents analyzed were a reactivity insertion accident (RIA) and a large break loss-of-coolant accident (LBLOCA). The RIA was simulated by the insertion of a reactivity ramp of $1 (one dollar) in 0.1 s at hot full power (HFP) condition. The LBLOCA was a simulation of a double-ended pipe break in one of the cold legs of the primary loops. Differences in thermal responses of the fuel and the cladding are attributed to their thermal properties. The U{sub 3}Si{sub 2} fuel with its lower volumetric heat capacity and higher thermal conductivity (i.e. higher thermal diffusivity) generally results in a lower fuel temperature than the UO{sub 2} fuel and a correspondingly faster thermal response. Additional calculations for the U{sub 3}Si{sub 2} fuel shows that in a RIA the cladding material, SiC versus Zr, has little impact on the maximum fuel centerline temperature and the PCT (peak cladding temperature). An increase in the hot rod power factor is shown to raise the centerline fuel temperature in a RIA but has little impact on the PCT. The analysis results show that for a relatively fast decay heat driven transient, such as the LBLOCA, the thermal-hydraulics and fuel/cladding thermal properties dictate the overall response more so than the reactivity feedback. The results show that the PCTs in a LBLOCA are similar for all fuel/cladding combinations considered in this study. The LBLOCA analysis also notes the impact of the asymmetry in the system response. The fuel rods in the sector of the core connected to the hot leg of the broken loop (Sector 1 in the PWR model) is shown to have a much lower PCT than fuel rods in the other five sectors of the core. Results of this study indicate that for the two DBAs considered (RIA and LBLOCA) the transient behavior and the resulting peak cladding temperature of the two ATF options (U{sub 3}Si{sub 2} fuel with SiC cladding and UO{sub 2} fuel with APMT cladding) are similar to the standard light-water reactor fuel (UO{sub 2} fuel with Zircaloy cladding). (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Space Station body mounted radiator design

Consideration has been given to utilizing the external area of the Space Station common modules or resource nodes to provide heat rejection. A program was undertaken to define the best body mounted radiator design, to define and build a full size test article and to conduct testing to verify performance. Trade studies were conducted and a preferred design selected. The selected design employed high performance grooved heat pipes of an off-the-shelf design. Twenty panels, each about 1.2 m wide by 5.6 m long are installed on each module rejecting a total of about 12 kW. The radiators are interfaced with the module thermal control loop by use of a refrigerant 21 loop with an on-orbit operable disconnect at each panel. A one-panel test article has been designed and is currently being fabricated. Testing is scheduled to be conducted in June of 1987.

Fleming, M. L.↗

Development and Experimental Evaluation of Passive Fuel Cell Thermal Control

To provide uniform cooling for a fuel cell stack, a cooling plate concept was evaluated. This concept utilized thin cooling plates to extract heat from the interior of a fuel cell stack and move this heat to a cooling manifold where it can be transferred to an external cooling fluid. The advantages of this cooling approach include a reduced number of ancillary components and the ability to directly utilize an external cooling fluid loop for cooling the fuel cell stack. A number of different types of cooling plates and manifolds were developed. The cooling plates consisted of two main types; a plate based on thermopyrolytic graphite (TPG) and a planar (or flat plate) heat pipe. The plates, along with solid metal control samples, were tested for both thermal and electrical conductivity. To transfer heat from the cooling plates to the cooling fluid, a number of manifold designs utilizing various materials were devised, constructed, and tested. A key aspect of the manifold was that it had to be electrically nonconductive so it would not short out the fuel cell stack during operation. Different manifold and cooling plate configurations were tested in a vacuum chamber to minimize convective heat losses. Cooling plates were placed in the grooves within the manifolds and heated with surface-mounted electric pad heaters. The plate temperature and its thermal distribution were recorded for all tested combinations of manifold cooling flow rates and heater power loads. This testing simulated the performance of the cooling plates and manifold within an operational fuel cell stack. Different types of control valves and control schemes were tested and evaluated based on their ability to maintain a constant temperature of the cooling plates. The control valves regulated the cooling fluid flow through the manifold, thereby controlling the heat flow to the cooling fluid. Through this work, a cooling plate and manifold system was developed that could maintain the cooling plates within a minimal temperature band with negligible thermal gradients over power profiles that would be experienced within an operating fuel cell stack.

Fuel Cells↗

Total Thermal Management of Battery Electric Vehicles (BEVs)

The key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10°C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor) (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.

Chowdhury, Sourav↗

Control development and sizing analysis for a 5th generation district heating and cooling network using Modelica

5th generation district heating and cooling system (5GDHC) are a relatively new concept. They use a single district loop near ambient temperature to provide heating and cooling. This paper improves on the modelling and control of a 5GDHC system called the reservoir network. The study updates the sewage heat exchanger plant model to more realistically represent seasonal changes, uses refined pump models with variable efficiency, introduces a ground coupled district pipe model to consider the inertia of the district network and implements a new control strategy for geothermal storage and sewage heat exchanger. The new approach reduced operating costs, mainly due to pumping cost for storage, sewage heat exchanger plant and distribution pump, while increasing the overall robustness of the approach in different sizing conditions. Thanks to the new controller, the pumping consumption was reduced by 21% with respect to the original baseline. Furthermore, the new control makes the system take better advantage of design changes, when reducing borehole field size and increasing the sewage heat exchanger size, the pumping energy savings become 29% with respect to the original baseline. Lastly, borehole field temperature stability was analyzed through 40 years of simulation.

Zanetti, Ettore↗

Two Phase Technology Development Initiatives

Three promising thermal technology development initiatives, vapor compression thermal control system, electronics cooling, and electrohydrodynamics applications are outlined herein. These technologies will provide thermal engineers with additional tools to meet the thermal challenges presented by increased power densities and reduced architectural options that will be available in future spacecraft. Goddard Space Flight Center and the University of Maryland are fabricating and testing a 'proto- flight' vapor compression based thermal control system for the Ultra Long Duration Balloon (ULDB) Program. The vapor compression system will be capable of transporting approximately 400 W of heat while providing a temperature lift of 60C. The system is constructed of 'commercial off-the-shelf' hardware that is modified to meet the unique environmental requirements of the ULDB. A demonstration flight is planned for 1999 or early 2000. Goddard Space Flight Center has embarked upon a multi-discipline effort to address a number of design issues regarding spacecraft electronics. The program addressed the high priority design issues concerning the total mass of standard spacecraft electronics enclosures and the impact of design changes on thermal performance. This presentation reviews the pertinent results of the Lightweight Electronics Enclosure Program. Electronics cooling is a growing challenge to thermal engineers due to increasing power densities and spacecraft architecture. The space-flight qualification program and preliminary results of thermal performance tests of copper-water heat pipes are presented. Electrohydrodynamics (EHD) is an emerging technology that uses the secondary forces that result from the application of an electric field to a flowing fluid to enhance heat transfer and manage fluid flow. A brief review of current EHD capabilities regarding heat transfer enhancement of commercial heat exchangers and capillary pumped loops is presented. Goddard Space Flight Center research efforts applying this technique to fluid management and fluid pumping are discussed.

Didion, Jeffrey R.↗