Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Design and demonstration of a low‐field magnetic resonance imaging rhizotron for in‐field imaging of energy sorghum roots

Abstract Root phenotyping provides critical information to plant breeders for developing varieties with improved drought tolerance, greater root biomass, and greater nutrient use efficiency. Phenotyping roots in the natural environment is important for understanding the effect of the soil environment on root genotypic expressions. The goal of this work was to design and test a field‐scale mobile low‐field magnetic resonance imaging (LF‐MRI) Rhizotron that produces actionable root phenotyping data. We demonstrated this novel technology for root visualization and quantification using a LF‐MRI Rhizotron operating at 47 mT with two soil types. The LF‐MRI Rhizotron weights 453 kg, with a height of 90 cm, a diameter of 28 cm and an imaging field of view of 28 cm × 28 cm. The unit was operated in a Belk clay (Entic Hapluderts) and Weswood silt loam (Udifluventic Halustepts) generating 2‐D and 3‐D image data sets. The 2‐D image data had a collection time of 16.5 min per image at an image resolution of 2.2 mm per pixel. The 3‐D data had a collection time of 13 h per image with a 2.2 × 2.2 × 2.2 mm voxel resolution. Low‐field magnetic resonance imaging worked well for visualizing roots in moderate to high clay soils, demonstrating the potential for this technology; however, the broad application of this platform is hampered due to the prohibitively long scanning time to obtain 3‐D images. By increasing the field strength, and therefore the signal‐to‐noise ratio, faster scan times can enable a more useful system for root phenotyping.

Bagnall, G. Cody↗

Metrics and extrapolation of resonant magnetic perturbation thresholds for ELM suppression

This large database study of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression thresholds in the AUG, DIII-D, EAST, and KSTAR tokamaks details the key strengths and weaknesses of RMP metrics. The RMP ELM suppression database used for this work contains plasma information at the time of transition from ELMing to ELM suppressed states where a clear experimental threshold is identified. The experimental threshold distributions are compared for five metrics: (1) the island overlap width, (2) pedestal top Chirikov overlap, (3) peeling edge displacement, (4) pedestal top resonant drive, and (5) edge dominant mode overlap. The distributions, the regularity of the dependence on RMP coil currents, and the sensitivities of a given metric to equilibrium reconstruction details are compared. The overlap metric proves to be a good compromise between including the appropriate plasma response physics and maintaining a numerical robustness. This quantity does not exhibit clear power-law scalings for projection, but machine learning can assist in predicting thresholds within the existing parameter ranges and providing uncertainty quantification of those predictions. Two new first-principles models, one utilizing a threshold from the non-linear Modified Rutherford equation evaluated at the pedestal top and one utilizing the SLAYER code to calculate the linear tearing threshold from torque balance, offer possible paths to extrapolation beyond the existing database parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Classification System for Identifying Women at Risk for Altered Partial Breast Irradiation Recommendations After Breast Magnetic Resonance Imaging

Purpose: To study the utility of preoperative breast MRI for partial breast irradiation (PBI) patient selection, using multivariable analysis of significant risk factors to create a classification rule. Methods and Materials: Between 2002 and 2009, 712 women with newly diagnosed breast cancer underwent preoperative bilateral breast MRI at Mayo Clinic Florida. Of this cohort, 566 were retrospectively deemed eligible for PBI according to the National Surgical Adjuvant Breast and Bowel Project Protocol B-39 inclusion criteria using physical examination, mammogram, and/or ultrasound. Magnetic resonance images were then reviewed to determine their impact on patient eligibility. The patient and tumor characteristics were evaluated to determine risk factors for altered PBI eligibility after MRI and to create a classification rule. Results: Of the 566 patients initially eligible for PBI, 141 (25%) were found ineligible because of pathologically proven MRI findings. Magnetic resonance imaging detected additional ipsilateral breast cancer in 118 (21%). Of these, 62 (11%) had more extensive disease than originally noted before MRI, and 64 (11%) had multicentric disease. Contralateral breast cancer was detected in 28 (5%). Four characteristics were found to be significantly associated with PBI ineligibility after MRI on multivariable analysis: premenopausal status (P=.021), detection by palpation (P<.001), first-degree relative with a history of breast cancer (P=.033), and lobular histology (P=.002). Risk factors were assigned a score of 0-2. The risk of altered PBI eligibility from MRI based on number of risk factors was 0:18%; 1:22%; 2:42%; 3:65%. Conclusions: Preoperative bilateral breast MRI altered the PBI recommendations for 25% of women. Women who may undergo PBI should be considered for breast MRI, especially those with lobular histology or with 2 or more of the following risk factors: premenopausal, detection by palpation, and first-degree relative with a history of breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High field nuclear magnetic resonance in transition metal substituted BaFe{sub 2}As{sub 2}

We report high field {sup 75}As nuclear magnetic resonance (NMR) measurements on Co and Cu substituted BaFe{sub 2}As{sub 2} single crystals displaying same structural/magnetic transition T{sub 0}≃128 K. From our anisotropy studies in the paramagnetic state, we strikingly found virtually identical quadrupolar splitting and consequently the quadrupole frequency ν{sub Q}≃2.57(1) MHz for both compounds, despite the claim that each Cu delivers 2 extra 3d electrons in BaFe{sub 2}As{sub 2} compared to Co substitution. These results allow us to conclude that a subtle change in the crystallographic structure, particularly in the Fe–As tetrahedra, must be the most probable tuning parameter to determine T{sub 0} in this class of superconductors rather than electronic doping. Furthermore, our NMR data around T{sub 0} suggest coexistence of tetragonal/paramagnetic and orthorhombic/antiferromagnetic phases between the structural and the spin density wave magnetic phase transitions, similarly to what was reported for K-doped BaFe{sub 2}As{sub 2} [Urbano et al., Phys. Rev. Lett. 105, 107001 (2010)].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new combined nuclear magnetic resonance and Raman spectroscopic probe applied to in situ investigations of catalysts and catalytic processes

Both Raman and nuclear magnetic resonance (NMR) spectroscopies are valuable analytical techniques capable of providing mechanistic information and thereby providing insights into chemical processes, including catalytic reactions. Since both techniques are chemically sensitive, they yield not only structural information but also quantitative analysis. In this work, for the first time, the combination of the two techniques in a single experimental apparatus is reported. This entailed the design of a new experimental probe capable of recording simultaneous measurements on the same sample and/or system of interest. The individual datasets acquired by each spectroscopic method are compared to their unmodified, stand-alone equivalents on a single sample as a means to benchmark this novel piece of equipment. The application towards monitoring reaction progress is demonstrated through the evolution of the homogeneous catalysed metathesis of 1‑hexene, with both experimental techniques able to detect reactant consumption and product evolution. This is extended by inclusion of magic angle spinning (MAS) NMR capabilities with a custom made MAS 7 mm rotor capable of spinning speeds up to 1600 Hz, quantified by analysis of the spinning sidebands of a sample of KBr. The value of this is demonstrated through an application involving heterogeneous catalysis, namely the metathesis of 2-pentene and ethene. This provides the added benefit of being able to monitor both the reaction progress (by NMR spectroscopy) and also the structure of the catalyst (by Raman spectroscopy) on the very same sample, facilitating the development of structure-performance relationships.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear-magnetic-resonance quantum calculations of the Jones polynomial

The repertoire of problems theoretically solvable by a quantum computer recently expanded to include the approximate evaluation of knot invariants, specifically the Jones polynomial. The experimental implementation of this evaluation, however, involves many known experimental challenges. Here we present experimental results for a small-scale approximate evaluation of the Jones polynomial by nuclear magnetic resonance (NMR); in addition, we show how to escape from the limitations of NMR approaches that employ pseudopure states. Specifically, we use two spin-1/2 nuclei of natural abundance chloroform and apply a sequence of unitary transforms representing the trefoil knot, the figure-eight knot, and the Borromean rings. After measuring the nuclear spin state of the molecule in each case, we are able to estimate the value of the Jones polynomial for each of the knots.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The use of atlas registration and graph cuts for prostate segmentation in magnetic resonance images

Purpose: An automatic method for 3D prostate segmentation in magnetic resonance (MR) images is presented for planning image-guided radiotherapy treatment of prostate cancer. Methods: A spatial prior based on intersubject atlas registration is combined with organ-specific intensity information in a graph cut segmentation framework. The segmentation is tested on 67 axial T{sub 2}-weighted MR images in a leave-one-out cross validation experiment and compared with both manual reference segmentations and with multiatlas-based segmentations using majority voting atlas fusion. The impact of atlas selection is investigated in both the traditional atlas-based segmentation and the new graph cut method that combines atlas and intensity information in order to improve the segmentation accuracy. Best results were achieved using the method that combines intensity information, shape information, and atlas selection in the graph cut framework. Results: A mean Dice similarity coefficient (DSC) of 0.88 and a mean surface distance (MSD) of 1.45 mm with respect to the manual delineation were achieved. Conclusions: This approaches the interobserver DSC of 0.90 and interobserver MSD 0f 1.15 mm and is comparable to other studies performing prostate segmentation in MR.

60 APPLIED LIFE SCIENCES↗

Magnetic resonance imaging of living systems by remote detection

A novel approach to magnetic resonance imaging is disclosed. Blood flowing through a living system is prepolarized, and then encoded. The polarization can be achieved using permanent or superconducting magnets. The polarization may be carried out upstream of the region to be encoded or at the place of encoding. In the case of an MRI of a brain, polarization of flowing blood can be effected by placing a magnet over a section of the body such as the heart upstream of the head. Alternatively, polarization and encoding can be effected at the same location. Detection occurs at a remote location, using a separate detection device such as an optical atomic magnetometer, or an inductive Faraday coil. The detector may be placed on the surface of the skin next to a blood vessel such as a jugular vein carrying blood away from the encoded region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and magnetic resonance investigations of CuCr{sub 2}S{sub 4} nanoclusters and nanocrystals

Nanoclusters and nanocrystals of the room temperature magnetic spinel CuCr{sub 2}S{sub 4} synthesized using a facile solution-based method have been examined by transmission electron microscopy, magnetic measurements, and magnetic resonance over a wide frequency range 9.6–80 GHz and at temperatures down to 4.2 K. Decreasing of the resonance field and broadening of the resonance lines below 50 K for both samples are due to the freezing of magnetic moments of nanocubes and nanocrystalline particles constituting nanoclusters. The effective fields of averaged magnetic anisotropy 〈H{sub A}〉≅ 2.4 kOe are similar for both nanopowder samples as estimated from resonance measurements at T = 4.2 K. An additional blocking temperature T{sub b} ≅ 300 K appears in nanoclusters due to freezing of the magnetic moment of the entire cluster as a whole. Below this blocking temperature, the magnetic dipolar field acting in boundary areas of interacting constituent nanocrystals is responsible for the additional low-field resonance line observed in the resonance spectra of nanoclusters at X-band.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Folate conjugated Mn{sub 3}O{sub 4}@SiO{sub 2} nanoparticles for targeted magnetic resonance imaging in vivo

Graphical abstract: The Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA has been used as a T{sub 1}-MRI probe for in vivo. - Highlights: • The PEG and FA modified Mn{sub 3}O{sub 4}@SiO{sub 2} nanoparticles (Mn{sub 3}O{sub 4}@SiO{sub 2}–FA) were prepared. • Mn{sub 3}O{sub 4}@SiO{sub 2}–FA exhibited the good colloidal stability in the simulated biological medium. • Mn{sub 3}O{sub 4}@SiO{sub 2}–FA showed the targeting ability to HeLa cells overexpressed the FA receptor. • The T{sub 1}-weighted magnetic resonance (MR) imaging demonstrated the targeting ability of Mn{sub 3}O{sub 4}@SiO{sub 2}–FA in vivo tumor. - Abstract: The monodisperse silica-coated manganese oxide nanoparticles (Mn{sub 3}O{sub 4}@SiO{sub 2} NPs) were synthesized via the high temperature pyrolysis approach and were aminated through silanization. The amine-functionalized Mn{sub 3}O{sub 4} NPs enabled the covalent conjugation of hydrophilic methoxypoly(ethylene glycol) (PEG) and the targeting ligand of folate (FA) onto their surface. The formed PEG and FA modified Mn{sub 3}O{sub 4} NPs (Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA) exhibited the good colloidal stability in the simulated biological medium and the targeting ability to HeLa cells overexpressed the FA receptor. The T{sub 1}-weighted magnetic resonance (MR) imaging and inductively coupled plasma atomic emission spectroscopy (ICP-AES) analysis of Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA NPs further demonstrated their targeting ability in tumor.

36 MATERIALS SCIENCE↗

Nuclear magnetic resonance investigation of superconducting and normal state Nb 3 Sn

The superconductor Nb3Sn has important applications for construction of very high-field superconducting magnets. In this work we investigate its microscopic electronic structure with 93 Nb nuclear magnetic resonance (NMR). The high-quality Nb 3 Sn powder sample was studied in both 3.2 T and 7 T magnetic fields in the temperature range from 4 K to 300 K. From measurement of the spectrum and its theoretical analysis, we find evidence for anisotropy despite its cubic crystal structure. Magnetic alignment of the powder grains in the superconducting state was also observed. The Knight shift and spin-lattice relaxation rate, T 1 -1 , were measured and the latter compared with BCS theory for the energy gap Δ(0) = 2.7 ± 0.3k B T c at 3.2 T and Δ(0) = 2.33 ± 0.07 k B T c at 7 T, indicating suppression of the order parameter by magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Resonance Lymphography-Guided Selective High-Dose Lymph Node Irradiation in Prostate Cancer

Purpose: To demonstrate the feasibility of magnetic resonance lymphography (MRL) -guided delineation of a boost volume and an elective target volume for pelvic lymph node irradiation in patients with prostate cancer. The feasibility of irradiating these volumes with a high-dose boost to the MRL-positive lymph nodes in conjunction with irradiation of the prostate using intensity-modulated radiotherapy (IMRT) was also investigated. Methods and Materials: In 4 prostate cancer patients with a high risk of lymph node involvement but no enlarged lymph nodes on CT and/or MRI, MRL detected pathological lymph nodes in the pelvis. These lymph nodes were identified and delineated on a radiotherapy planning CT to create a boost volume. Based on the location of the MRL-positive lymph nodes, the standard elective pelvic target volume was individualized. An IMRT plan with a simultaneous integrated boost (SIB) was created with dose prescriptions of 42 Gy to the pelvic target volume, a boost to 60 Gy to the MRL-positive lymph nodes, and 72 Gy to the prostate. Results: All MRL-positive lymph nodes could be identified on the planning CT. This information could be used to delineate a boost volume and to individualize the pelvic target volume for elective irradiation. IMRT planning delivered highly acceptable radiotherapy plans with regard to the prescribed dose levels and the dose to the organs at risk (OARs). Conclusion: MRL can be used to select patients with limited lymph node involvement for pelvic radiotherapy. MRL-guided delineation of a boost volume and an elective pelvic target volume for selective high-dose lymph node irradiation with IMRT is feasible. Whether this approach will result in improved outcome for these patients needs to be investigated in further clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Computed Tomography– and Magnetic Resonance Imaging–based Clinical Target Volume Contours at Brachytherapy for Cervical Cancer

Purpose: We prospectively compared computed tomography (CT)– and magnetic resonance imaging (MRI)–based high-risk clinical target volume (HR-CTV) contours at the time of brachytherapy for cervical cancer in an effort to identify patients who might benefit most from MRI-based planning. Methods and Materials: Thirty-seven patients who had undergone a pretreatment diagnostic MRI scan were included in the analysis. We delineated the HR-CTV on the brachytherapy CT and brachytherapy MRI scans independently for each patient. We then calculated the absolute volumes for each HR-CTV and the Dice coefficient of similarity (DC, a measure of spatial agreement) for the HR-CTV contours. We identified the clinical and tumor factors associated with (1) a discrepancy in volume between the CT HR-CTV and MRI HR-CTV contours; and (2) DC. The mean values were compared using 1-way analysis of variance or paired or unpaired t tests, as appropriate. Simple and multivariable linear regression analyses were used to model the effects of covariates on the outcomes. Results: Patients with International Federation of Gynecology and Obstetrics stage IB to IVA cervical cancer were treated with intracavitary brachytherapy using tandem and ovoid (n=33) or tandem and cylinder (n=4) applicators. The mean CT HR-CTV volume (44.1 cm{sup 3}) was larger than the mean MRI HR-CTV volume (35.1 cm{sup 3}; P<.0001, paired t test). On multivariable analysis, a higher body mass index (BMI) and tumor size ≥5 cm with parametrial invasion on the MRI scan at diagnosis were associated with an increased discrepancy in volume between the HR-CTV contours (P<.02 for both). In addition, the spatial agreement (as measured by DC) between the HR-CTV contours decreased with an increasing BMI (P=.013). Conclusions: We recommend MRI-based brachytherapy planning for patients with tumors >5 cm and parametrial invasion on MRI at diagnosis and for those with a high BMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging Appearances in the Postoperative Breast: The Clinical Target Volume-Tumor and Its Relationship to the Chest Wall

Purpose: To describe and measure the postoperative complexes and their relationship to the chest wall in 100 randomly chosen MRI breast scans, to attempt a better understanding of the changes taking place in the postoperative breast. Methods and Materials: Appearances and measurements of MRI postoperative cavities were analyzed in a cohort of 100 randomly selected patients who underwent a single open MRI scan in the conventional breast radiotherapy treatment position before routine two-dimensional simulation. Results: Magnetic resonance imaging appearances of postoperative cavities seem to differ qualitatively from descriptions of CT and ultrasound cavities in the literature. Rather than being principally homogeneous, heterogeneous cavities were seen in 85%, irregular in 51%. The size of cavity was inversely related to the time elapsed since surgery. Cavities directly touched the chest wall in 53% of cases; 89% lay within 10 mm of the chest wall. Regular, annular concentric rings of differing signal were seen in 32% of cases; such appearances have not been previously described. These patterns suggest that seromas may not shrink entirely as a result of simple serous fluid absorption; instead, new tissue may be being laid down. Because large, regular spheroidal/ellipsoidal cavities with crisp margins may be seromas under pressure, greater target shifts during radiation may need to be anticipated in such cases. Conclusions: Postsurgical cavities in the conserved breast on MRI are commonly heterogeneous, irregular, and lie close to the chest wall. Magnetic resonance imaging studies may help in better understanding the natural history of postoperative cavities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broadband, large-area microwave antenna for optically detected magnetic resonance of nitrogen-vacancy centers in diamond

We report on a microwave planar ring antenna specifically designed for optically detected magnetic resonance (ODMR) of nitrogen-vacancy (NV) centers in diamond. It has the resonance frequency at around 2.87 GHz with the bandwidth of 400 MHz, ensuring that ODMR can be observed under external magnetic fields up to 100 G without the need of adjustment of the resonance frequency. It is also spatially uniform within the 1-mm-diameter center hole, enabling the magnetic-field imaging in the wide spatial range. These features facilitate the experiments on quantum sensing and imaging using NV centers at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperintensity in the Dentate Nucleus on Nonenhanced T1-Weighted Magnetic Resonance Imaging Suggests Dechelation of Contrast Agents

With the exception of renal failure patients, gadolinium-based contrast agents (GBCAs) for magnetic resonance imaging (MRI) have a high tolerance and acceptability in patients needing to undergo an enhanced MRI. Now that enhanced MRIs are becoming increasingly popular and nephrogenic systemic fibrosis cases are becoming a rarity, a common belief is that these GBCAs are essentially “biologically inert” materials. However, recent reports have emerged querying the link between these GBCAs and hyperintensity in the dentate nucleus on unenhanced T1-weighted MRI in some patients. This review article outlines the basic chemistry and characteristics of currently approved GBCAs, summarizes the described research findings of gadolinium deposition in the dentate nucleus, and identifies areas for future research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear magnetic resonance study of Li and H diffusion in the high-temperature solid phase of LiBH{sub 4}

In order to study the atomic jump motions in the high-temperature solid phase of LiBH{sub 4}, we have measured the {sup 1}H and {sup 11}B nuclear magnetic resonance (NMR) spectra and the {sup 1}H, {sup 7}Li and {sup 11}B spin-lattice relaxation rates in this compound over the resonance frequency range of 14-34.4 MHz. In the temperature range 384-500 K, all the spin-lattice relaxation data are satisfactorily described in terms of a thermally activated jump motion of Li ions with the pre-exponential factor tau{sub 0}=1.1x10{sup -15} s and the activation energy E{sub a}=0.56 eV. The observed frequency dependences of the spin-lattice relaxation rates in this temperature range exclude a presence of any distributions of the Li jump rate or any other jump processes on the frequency scale of 10{sup 7}-10{sup 10} s{sup -1}. The strong narrowing of the {sup 1}H and {sup 11}B NMR lines above 440 K is consistent with the onset of diffusive motion of the BH{sub 4} tetrahedra. - Graphical abstract: The measured spin-lattice relaxation rates of {sup 1}H (a), {sup 7}Li (b) and {sup 11}B (c) as functions of the inverse temperature for the high-temperature solid phase of LiBH{sub 4}. The curves show the simultaneous Bloembergen-Purcell-Pound fits to the data with the fixed parameters of Li diffusion (the pre-exponential factor tau{sub 0}=1.1x10{sup -15} s and the activation energy E{sub a}=0.56 eV). This plot indicates that all the relaxation data for different nuclei and at different resonance frequencies are governed by a single Li jump process. Display Omitted

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of the edge stochastic layer in density pump-out by resonant magnetic perturbations

The role of the edge stochastic layer on particle transport is addressed in DIII-D plasmas with applied resonant magnetic perturbations (RMPs) causing density pump-out (a term used to denote the density reduction at the top of the pedestal due to the applied RMPs). Using an analytical model that adds the stochastic parallel transport of electrons (Harvey et al 1981 Phys. Rev. Lett. 47 102) to the fluid equations, the ambipolar radial electric field and particle flux are calculated simultaneously. In this model the nonambipolar electron particle flux, driven by the stochastic magnetic field, is predominantly balanced by the nonambipolar perpendicular ion flux, driven by toroidal viscosity, across a narrow stochastic layer of order two percent of the plasma radius (0.98 < ψn < 1). The model reproduces the level of density pump-out and its dependence on RMP amplitude near the separatrix for three plasma discharges for which the pedestal foot is at medium to high collisionality $(2\leqslant {\nu }_{\text{sep}}^{\ast }\leqslant 30)$. In this work, the experimentally observed and numerically tested inverse density dependence of density pump-out (Hu et al 2020 Nucl. Fusion 60 076001) is accurately captured by the model: an increase in collisionality with density in the pedestal foot results in a decrease in stochastic diffusivity, and hence a decrease in the level of pump-out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗