At least 325 records · Page 18

0.4- to 10-GHz airborne electromagnetic-environment survey of United States urban areas

An airborne electromagnetic-environment survey of some U.S. metropolitan areas measured terrestrial emissions within the broad-frequency spectrum from 0.4 to 10 GHz. A Cessna 402 commercial aircraft was fitted with both nadir-viewing and horizon-viewing antennas and instrumentation, including a spectrum analyzer, a 35-mm continuous-film camera, and a magnetic-tape recorder. Most of the flights were made at a nominal altitude of 10,000 ft, and Washington, Baltimore, Philadelphia, New York, and Chicago were surveyed. The 450- to 470-MHz land-mobile UHF band is especially crowded, and the 400- to 406-MHz space bands are less active. Test measurements obtained up to 10 GHz are discussed. Sample spectrum-analyzer photographs were selected from a total of 5750 frames representing 38 hours of data.

Taylor, R. E.↗

The University of Texas catalog of ultraviolet and optical stellar data

The paper describes a plan to assemble a master catalog of early-type stars to at least 10th magnitude, containing a single value for each magnitude and the spectral type, with information on photometry, known peculiarities, duplicity, etc., which will serve as a collection of ground-based data to aid in the reduction and analysis of ultraviolet spectra obtained with the S-019 experiment on Skylab, in which objective prism photographs recorded nearly 10,000 stars at wavelengths shortward of 3000 A. The starting point is the Celescope Identification Catalog; several other catalogs will be compared and merged with this data base. The format for recording the wanted data on magnetic tape and the procedure for assembling the master file are discussed.

Parsons, S. B.↗

The critical evaluation of stellar data

The paper discusses the importance of evaluating a catalog of stellar data, whether it is an old catalog being made available in machine-readable form, or a new catalog written expressly in machine-readable form, and discusses some principles to be followed in the evaluation of such data. A procedure to be followed when checking out an astronomical catalog on magnetic tape is described. A cross index system which relates the different identification numbers of a star or other astronomical object as they appear in different catalogs in machine-readable form is described.

Underhill, A. B.↗

Flooding of Monroe County, Michigan - A comparison of three remote sensor data sets

During the spring of 1973, three techniques were used to obtain remotely sensed data pertaining to the flooded shoreline of Monroe County, Michigan. Although digitized data from the Earth Resources Technology Satellite were available on magnetic tapes, analysis was based on interpretation methods normally used for aerial photography, since the black and white IR photography and side-looking airborne radar (SLAR) data were available only as images. Using IR photography as the standard, it was found that ERTS-1 Band 7 imagery had a 93% accuracy in detecting areas in the combined category of open water and flooded fields. X(HH) data from SLAR detected that built-up and wet areas were built-up (89 to 100% accuracy), but not that they were wet. It is suggested that these two sensors used in concert from orbital heights could provide information useful to relief organizations in flooded areas. It is considered likely that SLAR data will improve as higher resolution becomes available.

Bryan, M. L.↗

Simulation of the Effects of Hard Limiting on Image Quality of Synthetic Aperture Radar

Starting with a magnetic tape of a scene viewed by the Landsat satellite, the radar return of reflectors whose average intensity matched that of the picture elements in the scene has been simulated. The returns were processed in three ways: normally or with no quantization, with a procedure simulation IF hard limiting, and with a procedure simulating video (baseband) hard limiting. For each type of processing an image for a one, two, and four-look system has been developed. It was found that IF limiting is slightly better than video limiting, while both can be reasonable trade-offs of image quality for reduced data rates when the number of looks is four or less. These conclusions are supported by photographs representing the different processing techniques.

Lipes, R. G.↗

Bit-synchronizer lock detector

Circuit measures phase error that exists in phase-locked loop between clock signal recorded in data on magnetic tape and reconstructed clock signal. Circuit presents error as digital word that can be compared with predetermined threshold to indicate lock status. With simple alterations, circuit can also be used as phase detector.

Huey, D. C.↗

Software for transferring NASTRAN datablocks between dissimilar computers

Efforts to freely exchange all types of NASTRAN datablocks between the internalized forms in any of three makes of NASTRAN-class computers and that of any other such make are described. The medium used is magnetic tape formatted in BCD (Binary Coded Decimal) character and numerical fields. The method used involves a FORTRAN-coded post-processor and a pre-processor, mostly portable but with a small assembly-coded component peculiar to each make of machine. Snags in a method reported in an earlier NASTRAN colloquium have been overcome and functional requirements upgraded as well.

Rosencranz, R.↗

Use of thermal-infrared imagery in ground-water investigations in Montana

Thermal infrared imagery was used to locate ground-water inflow along three streams and one lake in Montana. The thermal scanner used in May 1972, March 1973, and November 1975 was mounted in a twin-engined aircraft. On the 1973 and 1975 flights, the data were recorded in an analog format on magnetic tape in flight, later were converted to digital format, and were computer processed using an assignment of patterns to indicate differences in water temperature. Output from the image processing program was converted to a temperature map having an isotherm spacing of 0.5 C. Computerization was found to be the most efficient method to manipulate data from lakes, large rivers, and narrow sinuous streams.

Boettcher, A. J.↗

Viking Lander imaging investigation: Picture catalog of primary mission experiment data record

All the images returned by the two Viking Landers during the primary phase of the Viking Mission are presented. Listings of supplemental information which described the conditions under which the images were acquired are included together with skyline drawings which show where the images are positioned in the field of view of the cameras. Subsets of the images are listed in a variety of sequences to aid in locating images of interest. The format and organization of the digital magnetic tape storage of the images are described. The mission and the camera system are briefly described.

Tucker, R. B.↗

Investigation of a high speed data handling system for use with multispectral aircraft scanners

A buffer memory data handling technique for use with multispectral aircraft scanners is presented which allows digital data generated at high data rates to be recorded on magnetic tape. A digital memory is used to temporarily store the data for subsequent recording at slower rates during the passive time of the scan line, thereby increasing the maximum data rate recording capability over real-time recording. Three possible implementations are described and the maximum data rate capability is defined in terms of the speed capability of the key hardware components. The maximum data rates can be used to define the maximum ground resolution achievable by a multispectral aircraft scanner using conventional data handling techniques.

Kelly, W. L.↗

Photomask and pattern programming manual

A user's manual for a set of computer programs written in FORTRAN for the layout and generation of photomasks is presented. A limited amount of related information on photomasks, their design, and use is included. Input to the programs includes data describing the photomask design. Possible outputs include plots of the layout and a magnetic tape for controlling generation of the photomask by a pattern generator.

Kirschman, R. K.↗

Satellite applications to a coastal inlet study, Clearwater Beach, Florida

Two sets of LANDSAT magnetic tapes were obtained and displayed on the screen of an IMAGE 100 computer. Spectral analysis was performed to produce various signatures, their extent and location. Subsequent ground truth observations and measurements were gathered by means of hydrographic surveys and low-altitude aerial photography for interpretation and calibration of the LANDSAT data. Finally, a coastal engineering assessment based on the LANDSAT data was made. Recommendations to the City of Clearwater regarding the navigational channel alignment and dredging practice are presented in the light of the inlet stability.

Wang, Y. H.↗

High data volume and transfer rate techniques used at NASA's image processing facility

Data storage and transfer operations at a new image processing facility are described. The equipment includes high density digital magnetic tape drives and specially designed controllers to provide an interface between the tape drives and computerized image processing systems. The controller performs the functions necessary to convert the continuous serial data stream from the tape drive to a word-parallel blocked data stream which then goes to the computer-based system. With regard to the tape packing density, 1.8 times 10 to the tenth data bits are stored on a reel of one-inch tape. System components and their operation are surveyed, and studies on advanced storage techniques are summarized.

Heffner, P.↗

The McDonald Observatory lunar laser ranging project

A summary of the activities of the McDonald lunar laser ranging station at Fort Davis for the FY 77-78 fiscal year is presented. The lunar laser experiment uses the observatory 2.7m reflecting telescope on a thrice-per-day, 21-day-per-lunation schedule. Data are recorded on magnetic tapes and sent to the University of Texas at Austin where the data is processed. After processing, the data is distributed to interested analysis centers and later to the National Space Science Data Center where it is available for routine distribution. Detailed reports are published on the McDonald operations after every fourth lunation or approximately once every 115 days. These reports contain a day-by-day documentation of the ranging activity, detailed discussions of the equipment development efforts, and an abundance of other information as is needed to document and archive this important data type.

Silverberg, E. C.↗

Process air quality data

Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.

Butler, C. M.↗

Loran-C flight data base

Loran-C time-difference data were collected on January 9, 1979 during a flight from Athens, Ohio to Madison VOR in Connecticut, thence to Millville VOR in New Jersey, and a landing at Atlantic City NAFEC. Portions of the return trip to Athens, Ohio were also recorded. Loran-C GRI data frames were recorded using the 99600 U. S. Northeast Loran chain stations Seneca/Nantucket (TDA) and Seneca/Carolina Beach (TDB). The GRI sequence number TDA and TDB were recorded as integer numbers, with the TD's in integer microseconds. Actual time-of-day can be determined from the data start time, plus the time per GRI and the sequence number. The low cost Loran-C receiver was used to obtain the time-difference data for each GRI. Data was recorded on digital magnetic tape and post-processed into latitude and longitude using an IBM system/370 computer.

Lilley, R. W.↗

A catalog of jovian decameter-wave radio observations from 1957 - 1978

Data from over 200,000 hours of observation of Jupiter radio emission in the decameter-wavelength band, were collected from 13 observing sites and are available on magnetic tape. Observations were made at 14 fixed frequencies from 5 to 30 MHz. The characteristics of the tape recording technique and the data format are described. The combination of overlapping data from observing sites scattered world-wide lessens the effect of the earth's daily interruption of the ground-received signal. A power spectral analysis of the data shows no evidence of periodicities within the data other than the well-known influences of Jupiter, Io, and the earth. The dependence of the occurrence probability of emission on System 3 longitude and the phase of Io varies smoothly with frequency down to 15 MHz and then appears quite different at 10 MHz. The morphology of the radio sources is both complex and stable for periods of at least months and probably much longer.

Thieman, J. R.↗

Aircraft instrumentation system for the remote sensing of carbon monoxide

A light twin-engine aircraft has been instrumented with a carbon monoxide remote gas sensor system and test flown over the Southern Lake Michigan basin during August, 1976. The remote sensor is based on the gas filter correlation technique. The radiance levels from the sensor along with the data on the surface temperature, air temperature, dewpoint, and altitude were digitized and recorded on seven-track magnetic tape. Air samples were collected at various altitudes over selected sites for later analysis of carbon monoxide concentration and comparison with the inferred concentration from the remote sensor. The values of carbon monoxide obtained from the air samples and the values inferred from the remote sensor for data collected over water are in good agreement.

Beck, S. M.↗