At least 325 records · Page 18

Murine Spine Composition and Mechanics are Maintained After 30-Days of Spaceflight

As NASA prepares to send astronauts on deep space missions, understanding the detrimental effects of spaceflight on the body is imperative. Spaceflight is known to negatively affect the spine, with astronauts experiencing systemic bone loss and increased post-flight risk of intervertebral disc herniation. Space investigations with rodent models have characterized some of the effects of spaceflight on the mammalian body, but variable experimental conditions have made it difficult to cohesively interpret results. These conditions include housing, flight duration, and for the spine, anatomical location. Thus, the objective of this study was to comprehensively characterize the effects of spaceflight on the bulk properties of the murine lumbar spine. To do this, we examined the lumbar spine of mice flown on the NASA Rodent Research 10 mission and analyzed disc biochemical content, disc joint material properties, lumbar vertebral body microarchitecture, and proximal tibia microarchitecture. Finally, we qualitatively examined bone growth in the vertebral bodies using confocal microscopy and on-orbit injections of calcein. Contrary to prior results, we found little to no effect of spaceflight on lumbar spine properties. Spaceflight, however, did negatively affect both cortical and trabecular bone properties of the proximal tibia load-bearing site. We hypothesize that this may be due to loading associated with increased physical activity in the second half of the mission, observed on in-flight videos, that reload the lumbar spine as mice utilize quadruped ambulation. This increased activity occurs after an initial period of relative inactivity in microgravity. In support of this hypothesis, we observed new L5 bone formation in the last seven days of spaceflight, suggesting that current 30-day experimental flight conditions may not be as effective at lumbar spine unloading as previous shorter flights.

mouse↗

Evaluation of Intranasal Scopolamine for the Prevention of Wave Motion Induced Motion Sickness While Maintaining Performance on Operationally Relevant Tasks

Motion sickness represents one of the greatest clinical challenges impacting crew activities during and following g-transitions. Our overall goal is to characterize the effectiveness of motion sickness countermeasures during controlled laboratory experiments using capsule wave motion simulation and during field testing in operational environments. This laboratory study focused on prevention of motion sickness using intranasal scopolamine using a double-blinded repeated measures design in 30 subjects (19M, 11F). Intranasal scopolamine was provided by Defender Pharmaceuticals, Inc. (DPI-386 Nasal Gel, referred to as Inscop) self-administered by a nasal pump (Aptar Pharma) that delivers 0.4 mg dose (0.2 mg / nostril). During each session, subjects were exposed to complex wave motion on a six degree-of-freedom platform that included pitch, roll and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Motion sickness symptoms were compared across treatment and placebo control sessions counterbalanced across subjects and separated by at least one week. The time-to-motion sickness endpoint was based on severe malaise, defined as symptom score of ≥8 points using the Pensacola Diagnostic Index [1]. The bioavailability of scopolamine for each session was estimated from plasma concentrations obtained every 15 min[2]. Side effects during the treatment session were minimal, and performance was not impaired on a test battery including motion perception tracking, tablet-based eye-hand coordination and psychomotor vigilance testing. The plasma concentration remained near-peak levels throughout the 45 min motion sickness testing for most subjects. The percentile ranking on the Motion Sickness Susceptibility Questionnaire [MSSQ, 3]was moderately correlated with the motion sickness time-to-endpoint during the placebo control session (rho = –0.3, p=0.056). Seventeen subjects did not reach an endpoint during their placebo session and were eliminated from subsequent analysis. Another subject was excluded due to insufficient plasma concentration during the treatment session. For the remaining 12 subjects, the change in time-to-motion sickness endpoint between placebo and treatment sessions was moderately correlated with plasma concentration (rho =0.48, p = 0.056), improving on average 4.4 ± 18.4 min, mean ± std with Inscop versus placebo. Our results are consistent with previous findings that intranasal delivery of scopolamine can be effective at reducing motion sickness symptoms with minimal cognitive or sedative side effects. Future work is needed to optimize the delivery of Inscop for rescue (treatment) of symptoms following g-transitions as one of the key advantages of this formulation is self-administration in a suited environment. We will also explore how the combination of Inscop with non-pharmaceutical sensory aids, e.g., vibrotactile feedback of Earth vertical, may further mitigate motion sickness and improve task performance.

S J Wood↗

Maintaining the Continuity of the Global Climate Data Record of Lightning from Space

Lightning is a natural hazard, an indicator of changes in convective storm behavior across multiple spatial and temporal scales, and a major influence on climate-affecting chemicals such as ozone and methane. Lightning also has substantial impacts on the near-space environment. As such, the World Meteorological Organization (WMO) has designated lightning as an Essential Climate Variable (ECV); that is, a measurement that is really important for understanding Earth’s climate. Spaceborne lightning observations are the gold standard for measuring global lightning, as the detection efficiency is more spatially uniform compared to ground-based lightning measurements. In addition, spaceborne is the only practical method for measuring total lightning (i.e., both intracloud and cloud-to-ground) at the global scale, as ground-based networks have limited ability to detect intracloud lightning at long distances (e.g., over oceans, far from land-based sensors). Since 1995, with only a two-year gap (2015-2017), lightning has been observed globally using a combination of Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) instruments. However, the year 2023 is the planned end for the International Space Station (ISS) LIS mission, and there is no designated low-Earth orbit (LEO) successor yet identified. Since 2017, geostationary (GEO) observations of lightning have become increasingly available. These include the U.S. Geostationary Lightning Mappers (GLMs), China’s Lightning Mapping Imager (LMI), and Europe’s Lightning Imager (LI). While GEO provides continuous, quasi-hemispheric coverage of lightning and thunderstorms, there are current gaps preventing global coverage, particularly in portions of Asia and the western Pacific, as well as high-latitude regions. Moreover, integration of the GEO constellation into a Climate Data Record (CDR) of lightning is a major challenge only recently begun to be addressed by the WMO. Furthermore, recent work has demonstrated some deficiencies in the global record of lightning from space. For example, small lightning flashes are very common in severe weather, but are difficult to observe using the present set of spaceborne lightning imagers. Moreover, some types of lightning are best observed using frequencies other than the commonly used near-infrared (777-nm), including ultraviolet and the radio spectrum. Finally, it is not possible to assess the vertical distribution of lightning globally, even though this measurement is highly relevant to thunderstorm behavior as well as lightning’s effects on greenhouse gases and the near-space environment. This presentation will provide a current assessment of lightning measurements from space, will identify significant current and future gaps in these observations, and will evaluate potential solutions for improving the overall CDR of global lightning.

Timothy Lang↗

Data for The Value of Reversible Carbon Storage in a Zero-Emissions World

Atmospheric carbon dioxide removal (CDR) is required to stabilize global temperature. CDR can be achieved via ecosystem-based approaches that are cost-effective but reversible (e.g., soil and forest management) or by more durable but expensive approaches (e.g., direct air capture coupled with geologic storage). Here, we examine trade-offs between these approaches, focusing on timing, climate impacts, and cost. We simulated reversible carbon accrual for a range of CDR contract structures using a general minimalist model of ecosystem carbon cycling, and parameterized it to simulate US agricultural soil management─specifically cover cropping─as a case study. We then quantified the resulting impact on atmospheric carbon and global temperature using a climate model emulator. We find that maintaining a patchwork of reversible CDR projects by replacing lapsed projects with new projects can reduce warming by 22–195 μ°C in 2100 and that the magnitude of this cooling effect depends on how effectively the patchwork is maintained. Long-term maintenance of reversible CDR projects requires institutional stability that cannot be guaranteed over multiple decades. Consequently, effective CDR ultimately requires replacing reversible projects with durable projects. To address this problem, we modeled the cost of replacing reversible agricultural soil CDR with geologic CDR. We found that using reversible CDR as a bridge to durable CDR is potentially more cost-effective as a global cooling strategy (0.20–0.81 billion USD per μ°C avoided) than perpetual maintenance of reversible CDR (0.32–1.31 billion USD per μ°C avoided) or an immediate transition to durable CDR (1.37–2.19 billion USD per μ°C avoided). However, we emphasize that institutional commitments to maintain reversible CDR projects cannot be guaranteed. Reliance on reversible CDR as a bridge to durable CDR therefore carries an unknown amount of risk and will only function if efforts to maintain reversible CDR are robust.

Carbon↗

In vivo evaluation of an adaptive resuscitation controller using whole blood and crystalloid infusates for hemorrhagic shock

Introduction Hemorrhage remains the leading cause of preventable death on the battlefield. The most effective means to increase survivability is early hemorrhage control and fluid resuscitation. Unfortunately, fluid resuscitation requires constant adjustments to ensure casualty is properly managed, which is often not feasible in the pre-hospital setting. In this study, we showed how an adaptive closed-loop controller for hemorrhage resuscitation can be used to automate hemodynamic management using a swine hemorrhagic shock injury model. Methods The adaptive resuscitation controller (ARC) was previously developed to track pressure–volume responsiveness in real time and adjust its infusion rate to reach the target mean arterial pressure (MAP). Swine while maintained under a surgical plane of anesthesia and analgesia underwent a splenectomy, followed by two hemorrhage and resuscitation events. For the first resuscitation event, hemorrhage was induced to reduce the MAP to 35 mmHg until arterial lactate reached 4 mmol/L. The ARC system then infused whole blood (WB) to reach the target MAP and maintained the subject using crystalloids for 120 min. For the second resuscitation event, the subjects were hemorrhaged again but resuscitated using only crystalloid infusion to reach the target MAP and 120-min maintenance. Results The ARC was effective at WB resuscitation, reaching the target MAP in 2.0 ± 1.0 min. The median performance error was 1.1% ± 4.6%, and target overshoot was 14.4% ± 7.0% of the target MAP. The ARC maintained all animals throughout the 120 min maintenance period. For the second crystalloid-based resuscitation, ARC required a longer time to reach the target MAP, at an average rise time of 4.3 ± 4.0 min. However, target overshoot was reduced to 8.4% ± 7.3% of the target MAP. Much higher flow rates were required to maintain the target MAP during the second resuscitation event than during the first resuscitation event. Discussion The ARC was able to rapidly reach and maintain the target MAP effectively. However, this sometimes required large volumes of fluid as the ARC’s only goal was to reach the target MAP. Further clinical insight is needed regarding the preferred aggression level to achieve the target MAP. In conclusion, the ARC was successful in its programmed objective of reaching and maintaining the target MAP for extended periods of time in vivo , a critical next step toward improving hemorrhage treatment in the pre-hospital environment.

Snider, Eric J.↗

Excercise Within LBNP as an Artificial Gravity Countermeasure

Previous exercise in space has lacked sufficient loads to maintain preflight cardiovascular and musculoskeletal mass and function. Lower body negative pressure (LBNP) produces a static force equivalent to one Earth body weight by each 52 mm Hg of LBNP during supine posture. LBNP also provides transmural blood pressures simulating upright exercise. Thus, this artificial-gravity concept may help maintain cardiovascular and musculoskeletal systems of crewmembers during prolonged exposure to microgravity. Currently available, bungee cord assisted, treadmill exercise is limited by harness discomfort, lower than normal loads, abnormal post-flight gait, and the absence of gravitational blood pressures within the vascular system. PURPOSE: This project evaluates a method to create artificial gravity using supine LBNP treadmill exercise to prevent loss of physiologic function in microgravity simulated by 30 days of bed rest. Identical twins were used as volunteers so that statistical power could be maximized. This countermeasure is being transitioned to space flight. CURRENT STATUS OF RESEARCH Methods: Six sets of identical twins (6 females and 14 males, 21-36 years) remained in 6 head-down tilt (HDT) bed rest for 30 days to simulate prolonged microgravity. Six subjects were randomly selected to exercise supine in an LBNP chamber for 40 minutes six days per week (EX group), while their twin brothers served as non-exercise controls (CON). Pressure within the exercise LBNP chamber was adjusted to increase load, hence increasing exercise intensity. During supine treadmill exercise, LBNP (52-63 mmHg) was applied to produce foot ward forces equivalent to those for upright running on Earth at 1.0-1.2 times body weight (BW) and subjects performed an interval exercise protocol (40-80% peak exercise capacity [VO2pk]). Five minutes of resting LBNP immediately followed each exercise session. Results: Orthostatic tolerance time decreased significantly after 30 days bed rest in the CON group, but was relatively maintained in the EX group. VO2pk was maintained in EX males, but not in CON males. Isokinetic knee strength (extension, peak torque) decreased significantly in CON males, but was preserved in EX males. The EX group had significantly higher spine muscle strength after bed rest than the CON group. The cross-sectional area of spinal muscle at L4/5 level decreased significantly in the CON group but not in the EX group. Urinary n-telopeptide excretion, an index of bone resorption, was increased during bed rest in CON, but not in EX subjects. This suggests protection by LBNP exercise against the increase in bone resorption typically seen in simulated and actual microgravity. Significant changes in bone mineral density (BMD) in the spine and ribs were observed in CON subjects, but not in EX subjects. Conclusions: Our treadmill exercise protocol within LBNP plus a short period of post-exercise LBNP maintains orthostatic responses, upright exercise capacity and other important physiologic parameters during bed rest. These results document the efficacy of our apparatus and exercise protocol for maintaining physiologic structure and function during long-duration microgravity as simulated by 30 days of HDT bed rest. FUTURE PLANS: More sets of female identical twins are needed to reach significance. The LBNP exercise chamber will be redesigned for flight.

Hargens, A. R.↗

Thermal Performance of ATLAS Laser Thermal Control System Demonstration Unit

The second Ice, Cloud, and Land Elevation Satellite mission currently planned by National Aeronautics and Space Administration will measure global ice topography and canopy height using the Advanced Topographic Laser Altimeter System {ATLAS). The ATLAS comprises two lasers; but only one will be used at a time. Each laser will generate between 125 watts and 250 watts of heat, and each laser has its own optimal operating temperature that must be maintained within plus or minus 1 degree Centigrade accuracy by the Laser Thermal Control System (LTCS) consisting of a constant conductance heat pipe (CCHP), a loop heat pipe (LHP) and a radiator. The heat generated by the laser is acquired by the CCHP and transferred to the LHP, which delivers the heat to the radiator for ultimate rejection. The radiator can be exposed to temperatures between minus 71 degrees Centigrade and minus 93 degrees Centigrade. The two lasers can have different operating temperatures varying between plus 15 degrees Centigrade and plus 30 degrees Centigrade, and their operating temperatures are not known while the LTCS is being designed and built. Major challenges of the LTCS include: 1) A single thermal control system must maintain the ATLAS at 15 degrees Centigrade with 250 watts heat load and minus 71 degrees Centigrade radiator sink temperature, and maintain the ATLAS at plus 30 degrees Centigrade with 125 watts heat load and minus 93 degrees Centigrade radiator sink temperature. Furthermore, the LTCS must be qualification tested to maintain the ATLAS between plus 10 degrees Centigrade and plus 35 degrees Centigrade. 2) The LTCS must be shut down to ensure that the ATLAS can be maintained above its lowest desirable temperature of minus 2 degrees Centigrade during the survival mode. No software control algorithm for LTCS can be activated during survival and only thermostats can be used. 3) The radiator must be kept above minus 65 degrees Centigrade to prevent ammonia from freezing using no more than 135 watts of heater power. 4) The LHP reservoir control heater power is limited to 15 watts with a 70 percent duty cycle. 5) The voltage of the power supply can vary between 26 volts direct current and 34 volts direct current during the spacecraft lifetime. A design analysis shows that a single LTCS can satisfy these requirements. However, shutdown of· the LHP is particularly challenging and the shutdown heater must be wired in series with two reservoir thermostats and two CCHP thermostats at different set points. An LTCS demonstration unit has been tested to verify these performance characteristics experimentally prior to proceeding to the final LTCS design and fabrication. Test results showed that the LHP shutdown scheme would be able to shut down the LHP as designed and the reservoir control heater can maintain the ATLAS mass simulator within the plus or minus 1 degrees Centigrade accuracy under various combinations of the heat load, sink temperature, and power supply voltage.

Ku, Jentung↗

Integrated Logistics Support Analysis of the International Space Station Alpha: An Overview of the Maintenance Time Dependent Parameter Prediction Methods Enhancement

The objective of this publication is to introduce the enhancement methods for the overall reliability and maintainability methods of assessment on the International Space Station. It is essential that the process to predict the values of the maintenance time dependent variable parameters such as mean time between failure (MTBF) over time do not in themselves generate uncontrolled deviation in the results of the ILS analysis such as life cycle costs, spares calculation, etc. Furthermore, the very acute problems of micrometeorite, Cosmic rays, flares, atomic oxygen, ionization effects, orbital plumes and all the other factors that differentiate maintainable space operations from non-maintainable space operations and/or ground operations must be accounted for. Therefore, these parameters need be subjected to a special and complex process. Since reliability and maintainability strongly depend on the operating conditions that are encountered during the entire life of the International Space Station, it is important that such conditions are accurately identified at the beginning of the logistics support requirements process. Environmental conditions which exert a strong influence on International Space Station will be discussed in this report. Concurrent (combined) space environments may be more detrimental to the reliability and maintainability of the International Space Station than the effects of a single environment. In characterizing the logistics support requirements process, the developed design/test criteria must consider both the single and/or combined environments in anticipation of providing hardware capability to withstand the hazards of the International Space Station profile. The effects of the combined environments (typical) in a matrix relationship on the International Space Station will be shown. The combinations of the environments where the total effect is more damaging than the cumulative effects of the environments acting singly, may include a combination such as temperature, humidity, altitude, shock, and vibration while an item is being transported. The item's acceptance to its end-of-life sequence must be examined for these effects.

Sepehry-Fard, F.↗

Growth and maintenance of an embryogenic cell culture of daylily (Hemerocallis) on hormone-free medium

Callus cultures of the diploid daylily (Hemerocallis) clone Autumn Blaze' were initiated and maintained in hormone-containing nutrient medium. At various times (from 6 weeks to 1 year) after being initiated, hormone-derived cultures were evaluated for their ability to be maintained and to multiply on hormone-free medium at low pH (between pH 4 and 4.5). Cultures had to be exposed to hormone-containing medium for at least 12 weeks before they could be maintained on hormone-free medium at low pH. The transition to maintainability on low pH hormone-free medium included the production of many aberrant embryonal forms ( neomorphs'). However, all hormone-derived cultures tested consisted entirely of preglobular stage proembryos (PGSPs) after 12-24 weeks on low pH hormone-free medium. PGSP cultures have been maintained and multiplied as such for over 1 year on low pH hormone-free medium. PGSPs continue their development into various somatic embryo stages when cultured on hormone-free medium buffered at pH 5.8. The production of well-formed somatic embryos was greatly enhanced when PGSPs were plated on activated charcoal impregnated filter papers that were placed on top of the agar surface. The gross morphology and histology of the PGSPs and stages of somatic embryo development are presented. The work shows that the ability of hormone-free medium at low pH to permit PGSP multiplication without development into later stages of embryo development is not restricted to carrot.

Non-NASA Center↗

An Interoperability Concept for Detect and Avoid and Collision Avoidance Systems: Results from a Human-In-The-Loop Simulation

The integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS) poses a variety of technical challenges to UAS developers and aviation regulators. In response to growing demand for access to civil airspace in the United States, the Federal Aviation Administration (FAA) has produced a roadmap identifying key areas requiring further research and development. One such technical challenge is the development of a "detect and avoid" system (DAA) capable of providing a means of compliance with the "see and avoid" requirement in manned aviation. The purpose of the DAA system is to support the pilot, situated at a ground control station (GCS), in maintaining "DAA well clear" of nearby aircraft through the use of GCS displays and alerts. In addition to its primary function of aiding the pilot in maintaining DAA well clear, the DAA system must also safely interoperate with existing NAS systems and operations, such as the airspace management procedures of air traffic controllers (ATC) and Collision Avoidance (CA) systems currently in use by manned aircraft, namely the Traffic Alert and Collision Avoidance System (TCAS II). It is anticipated that many UAS architectures will integrate both a DAA system and a TCAS II. It is therefore necessary to explicitly study the integration of DAA and TCAS II alerting structures and maneuver guidance formats to ensure that pilots understand the appropriate type and urgency of their response to the various alerts. This paper presents a concept of interoperability for the two systems. The concept was developed with the goal of avoiding any negative impact on the performance level of TCAS II while retaining a DAA system that still effectively enables pilots to maintain DAA well clear. The interoperability concept described in the paper focuses primarily on facilitating the transition from a late-stage DAA encounter (where a loss of DAA well clear is imminent) to a TCAS II Corrective Resolution Advisory (RA), which requires pilot compliance within five seconds of its issuance. The interoperability concept was presented to 10 participants (6 active UAS pilots and 4 active commercial pilots) in a medium-fidelity, human-in-the-loop simulation designed to stress different aspects of the DAA and TCAS II systems. Pilots' ability to maintain separation, their rate of compliance and response times using the interoperability concept are reported. Results indicated that pilots exhibited comprehension of, and appropriate prioritization within, the DAA-TCAS II combined alert structure. Pilots demonstrated a high rate of compliance with TCAS II RAs and were also seen to respond to corrective RAs within the five second requirement established for manned aircraft. The DAA system presented under test was also shown to be effective in supporting pilots' ability to maintain DAA well clear in the overwhelming majority of cases in which pilots had sufficient time to respond.

Rorie, R. Conrad↗

Risk of Impaired Performance Due to Reduced Muscle Mass, Strength &, Endurance (Short Title: Muscle) and Risk of Reduced Physical Performance Capabilities Due to Reduced Aerobic Capacity (Short Title: Aerobic)

This report reviews the scientific literature regarding the human system risks to the microgravity environment of space flight in relation to human performance. The primary human performance-related risks involve deconditioning of the cardiovascular and skeletal muscles systems due to prolonged exposure to the reduced gravitational input. The chronological history of U.S. space flight is reviewed as a starting point to inform and understand the gaps in the knowledge to these risks. Maintenance of physical performance capabilities involves understanding the health of many organ systems (peripheral [vascular, heart, blood volume, skeletal muscle] and central [brain]) that ultimately contribute to the submaximal and maximal capacity of the aerobic (VO2peak), skeletal muscle (strength and endurance) systems. Maintaining astronaut VO2peak, muscle mass, strength, and endurance before, during, and after space flight is a significant priority to NASA for the current International Space Station (ISS) era, as well as for future exploration missions. A growing research database from both space flight and ground-based analog studies finds that the cardiorespiratory system is compromised and skeletal muscles (predominantly postural muscles of the lower limbs) undergo atrophy. These structural and metabolic responses to living in microgravity conditions contribute to physiological deconditioning during space flight that potentially increase the risks to astronauts returning to surface operations (i.e., Moon, Mars, or Earth). The time course changes from short to long-duration space flight and the relationships between in-flight performance deconditioning levels are not well characterized. Moreover, there are large interindividual variabilities that may be dependent on genetics, age, sex, preflight fitness levels, and individual exercise prescriptions that need further careful evaluations. Efforts should be made to understand the current status of preflight, in-flight, and postflight exercise performance capability and to define the operational goals and target areas for protection with the in-flight exercise program. There is a bi-directional relationship between exercise prescription and hardware countermeasures that need further understanding in-flight. For example, hardware with limited capabilities/modalities may be counterbalanced by changes in exercise prescription (i.e., frequency, time, intensity, volume) for providing effective responses to maintain fitness. Importantly, the minimal requirements for exercise prescription on ISS hardware may not translate to lower capability hardware on exploration missions. Due to limited volume on exploration vehicles, future Artemis missions to the Lunar surface will not have similar exercise hardware capabilities as ISS. This may alter the effectiveness of hardware to provide adequate physiological stress on bodily systems allowing for adaptations to maintain aerobic capacity, strength, and bone density. Thus, it will be important to understand the exercise responses of current ISS countermeasures to develop individualized exercise prescriptions that minimize aerobic and muscular risks, accounting for the large variability of responses among crewmembers. Newer exploration exercise hardware is currently being evaluated that is more compact (i.e., E4D and Orion Flywheel) and will require careful evaluation of the hardware on the stressor (i.e., metabolic rate, oxygen uptake, and heart rate work relationships, and force plate load profiles) needed the human body to protect and maintain crew health and performance. Moreover, exercise responses on the hardware need careful evaluation on the chronic adaptations. Lastly, in-flight evaluation of hardware exercise response may differ in 0-g or partial-g compared to 1-g. Therefore, it cannot be assumed that the stress on the body will be the same in each environment. Understanding this has a direct impact on exercise prescriptions. This document provides an overview of key scientific investigations that have been conducted before, during, and after human space flight missions, as well as from human ground-based analog studies that contribute to the evidence base on changes in aerobic capacity and muscle mass, strength, and endurance. Additional data from rodent and nonhuman primate experiments of skeletal muscle unloading completed during space flight or ground-based flight-simulations provide supportive information about this risk topic. Most importantly, a recent, large dataset from long-duration ISS crew has been added to give improved insight into the variability of exercise response of crew, demonstrating that a large portion of the crew population return to Earth with greater than 10-20% loss of aerobic capacity and muscle strength and endurance. Data from human space flight and ground-based studies are narrowing in on the required exercise paradigms but thus far still provide an incomplete answer to an effective approach for maintaining skeletal muscle function and aerobic fitness of all human space travelers. Finally, the relationship of this risk topic to various space flight operational scenarios is examined and discussed.

Eric Rivas↗