Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mass spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Role of a microbore capillary column in the development of a portable gas chromatograph-mass spectrometer

An approach to the development of a high-performance, field portable gas chromatograph-mass spectrometer is presented which is based on a combination of a short microbore capillary column and a miniaturized, light-weight focal plane mass spectrograph. Performance results of the short microbore column for the mixture separation of the major pollutants and data on time-resolved mass spectral measurements of overlapped gas chromatograph peaks are reported.

Sinha, Mahadeva P.↗

Laser Ablation Mass Spectrometer (LAMS) as a Standoff Analyzer in Space Missions for Airless Bodies

A laser ablation mass spectrometer (LAMS) based on a time-of-flight (TOF) analyzer with adjustable drift length is proposed as a standoff elemental composition sensor for space missions to airless bodies. It is found that the use of a retarding potential analyzer in combination with a two-stage reflectron enables LAMS to be operated at variable drift length. For field-free drift lengths between 33 cm to 100 cm, at least unit mass resolution can be maintained solely by adjustment of internal voltages, and without resorting to drastic reductions in sensitivity. Therefore, LAMS should be able to be mounted on a robotic arm and analyze samples at standoff distances of up to several tens of cm, permitting high operational flexibility and wide area coverage of heterogeneous regolith on airless bodies.

Li, X.↗

The use of the ion probe mass spectrometer in the measurement of hydrogen concentration gradients in Monel K 500

The ion probe mass spectrometer was used to measure hydrogen concentration gradients in cathodically charged Monel K 500. Initial work with the ion probe involved the calibration of the instrument and the establishment of a suitable experimental procedure for this application. Samples of Monel K 500 were cathodically charged in a weak sulfuric acid solution. By varying the current density, different levels of hydrogen were introduced into the samples. Hydrogen concentration gradients were taken by ion sputtering on the surface of these samples and monitoring the behavior of the hydrogen mass peak as a function of time. An attempt was made to determine the relative amounts of hydrogen in the bulk and grain boundaries by analyzing a fresh fracture surface with a higher proportion of grain boundary area. It was found that substantially more hydrogen was detected in the grain boundaries than in the bulk, confirming the predictions of previous workers. A sputter rate determination was made in order to establish the rate of erosion.

Truhan, J. J., Jr.↗

A high-voltage MR-ToF mass spectrometer and separator for the study of exotic isotopes at FRIB

The Facility for Rare Isotope Beams (FRIB) delivers a wide variety of rare isotopes as fast, stopped, or reaccelerated beams to enable forefront research in nuclear structure, astrophysics, and fundamental interactions. To expand the scientific potential of FRIB’s stopped and reaccelerated beam programs, we are designing a Multi-Reflection Time-of-Flight mass spectrometer and separator (MR-ToF MS). It will enable high-precision mass measurements of short-lived isotopes, improve beam diagnostics, and deliver isobarically and isomerically purified beams to downstream experimental stations. It is designed to store ions at a kinetic energy of 30 keV, significantly enhancing ion throughput while maintaining high mass resolving power. In conclusion, we present the scientific motivation, technical design, and simulations demonstrating the expected performance of the system, which has the potential to significantly enhance FRIB’s mass measurement, diagnostic, and mass separation capabilities.

Electrostatic ion beam trap↗

Observations of plasma dynamics in the coma of P/Halley by the Giotto ion mass spectrometer

The paper reports observations of plasma dynamics in the coma of P/Halley by the Giotto ion mass spectrometer. Measurements of protons and alpha particles from the far upstream region to the near ionopause region and of ions of mass 12-32 at distances of about 250,000 to 40,000 km from the nucleus are presented. The discontinuity known as the magnetic pileup boundary (MPB) is apparent only in proton, alpha particle, and magnetometer data, indicating that it is a tangential discontinuity of solar wind origin. No significant change is found in the properties of the heavy ions across the MPB. The issue of whether a cometopause was unambiguously observed at Comet Halley is discussed; it is concluded that the observations do not convincingly support the idea of a boundary due to internal cometary processes. A comparison of the observations to MHD models is made. The plasma flow directions at all distances greater than 30,000 km from the nucleus are in agreement with MHD calculations.

Goldstein, B. E.↗

A cometary ion mass spectrometer

The development of flight suitable analyzer units for that part of the GIOTTO Ion Mass Spectrometer (IMS) experiment designated the High Energy Range Spectrometer (HERS) is discussed. Topics covered include: design of the total ion-optical system for the HERS analyzer; the preparation of the design of analyzing magnet; the evaluation of microchannel plate detectors and associated two-dimensional anode arrays; and the fabrication and evaluation of two flight-suitable units of the complete ion-optical analyzer system including two-dimensional imaging detectors and associated image encoding electronics.

Shelley, E. G.↗

High-efficiency electron ionizer for a mass spectrometer array

The present invention provides an improved electron ionizer for use in a quadrupole mass spectrometer. The improved electron ionizer includes a repeller plate that ejects sample atoms or molecules, an ionizer chamber, a cathode that emits an electron beam into the ionizer chamber, an exit opening for excess electrons to escape, at least one shim plate to collimate said electron beam, extraction apertures, and a plurality of lens elements for focusing the extracted ions onto entrance apertures.

Chutjian, Ara↗

Measurement of the neutral composition of the lower thermosphere above Fort Churchill by rocket-borne mass spectrometer.

Measurement of the neutral atmospheric composition above Fort Churchill, Canada (59 N, 94 W), by mass spectrometers in two rocket flights at 0835 CST on Feb. 4 and 6, 1969. A quantitative measure for the extent of agreement with static diffusive equilibrium is introduced, and substantial agreement with profiles predicted when static diffusive equilibrium was assumed is found for all constituents including helium. A sensitive search for atomic nitrogen yielded upper limits of a few per cent for one flight and of 0.2% for the other.

Hickman, D. R.↗

Dual Source Mass Spectrometer and Sample Handling System

We present details of a miniature integrated time-of-flight mass spectrometer and sample handling system under development to address some of the needs for in situ sample analysis on landed missions. Additional information is contained in the original extended abstract.

Brinckerhoff, W. B.↗

Analysis of data from the Pioneer Venus Sounder Probe mass spectrometer

The composition of the lower atmosphere of the planet Venus from 62 km to the surface was measured by a neutral gas mass spectrometer onboard of the Pioneer Venus Sounder Probe. Fifty-one mass spectra were obtained with an average altitude resolution of approximately 1 km. The instrument measured the composition of the gases relative to CO2, the dominant gas, that is sampled from the Venus atmosphere through a special leak. The mass range extended from 1 to 208 amu with a sensitivity of the order of 1 ppm relative to CO2, but for the noble gases it was nearly 100 times better. A description of the instrument and the initial results are reported.

Hoffman, J. H.↗