Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-ω) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-ω spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

Pressure Sensitive Paint↗

Measurement of Gust Response on a Turbine Cascade

The paper presents benchmark experimental data on a gust response of an annular turbine cascade. The experiment was particularly designed to provide data for comparison with the results of a typical linearized gust-response analysis. Reduced frequency, Mach number, and incidence were varied independently. Except for the lowest reduced frequency, the gust velocity distribution was nearly sinusoidal. For the high inlet-velocity series of tests, the cascade was near choking. The mean flow was documented by measuring blade surface pressures and the cascade exit flow. High-response pressure transducers were used to measure the unsteady pressure distribution. Inlet-velocity components and turbulence parameters were measured using hot wire. In addition to the synchronous time-average pressure spectra, typical power spectra are included for several representative conditions.

Kurkov, A. P.↗

Measurement of Gust Response on a Turbine Cascade

This in-house experiment on the gust response of an annular turbine cascade was particularly designed to provide data to compare with the results of a typical, linearized gust-response analysis. Reduced frequency, Mach number, and incidence were varied independently. Except for the lowest reduced frequency, the gust velocity distribution was nearly sinusoidal. For the high inlet-velocity series of tests, the cascade was near choking. The mean flow was documented by measuring blade surface pressures and the cascade exit flow, and high-response pressure transducers were used to measure the unsteady pressure distribution. Inlet-velocity components and turbulence parameters were measured using hot wire anemometry. In addition to the synchronous time-averaged pressure spectra, typical power spectra are included for several representative conditions.

Kurkov, Anatole P.↗

Measurements of thermospheric response to auroral activities

The Joule heating produced by auroral electrojets and its thermospheric response can be studied by monitoring the thermospheric temperatures by optical methods; simultaneously, the concurrent auroral electrojet activities can be investigated by using geomagnetic records obtained from stations along a meridian close to the observation site of optical measurements. The measurements are reported of thermospheric response to auroral activities which were made at Albany (42.68 deg N, 73.82 deg W), New York on September 2, 1978 (UT) when an isolated substorm occured. The thermospheric temperatures were measured by using a high resolution Fabry-Perot interferometer that determines the line profiles of the (OI) 6300A line emission. The intensities and latitudinal positions of auroral electrojets were obtained by the analysis of magnetograms from the IMS Fort Churchill meridian chain stations.

Okano, S.↗

Predictions of F-111 TACT aircraft buffet response and correlations of fluctuating pressures measured on aluminum and steel models and the aircraft

Results of buffet research that was conducted as part of the joint USAF/NASA F-111 TACT Research Program are presented. The correlation of wind tunnel and flight measurements of buffet excitation showed that there generally was good agreement between measurements of pressure fluctuations on the models and aircraft in regions of separated flow. At shock-wave boundaries of the separated flow, correlations of pressure fluctuations were not so good, due to Reynolds number and static elastic effects. The buffet prediction method, which applies a forcing function that is obtained by real-time integration of pressure time histories with the natural modes, is described. The generalized forces, including the effects of wing and tail, correlations of predicted and measured damping, and correlations of predicted and measured buffet response are presented. All presented data are for a Mach number of 0.8 with wing-sweep angles of 26 and 35 deg for a range of angles-of-attack that include buffet onset to high intensity buffeting. Generally, the buffet predictions were considered to be quite good particularly in light of past buffet-prediction experience.

Coe, Charles F.↗

Research on measurement and control of helicopter rotor response using blade-mounted accelerometers 1991-92

Preliminary wind tunnel tests of the hill-size Model 412/IBC rotor at the Ames Research Center, NASA, are described. Blade flapping motion was excited by swash plate oscillation, and the flapping response was measured using blade-mounted accelerometers and compared with flapping motion inferred form blade strain measurements. The recorded open-loop accelerometer signals were used as input to the flapping-IBC system in the laboratory. The resulting controller cyclic pitch outputs are compared with the original cyclic pitch excitation inputs, and the potential effectiveness of the controller in suppressing the original excitation is evaluated. Control of blade flapping excites blade lagging, and vice versa; the paper describes a theoretical investigation of these coupling effects.

Ham, Norman D.↗

Measurement of control system response using an analog operational circuit

Ten basic steps are established for an analog method that measures control system response parameters. An example shows how these steps were used on a speed control portion of an auxiliary power unit. The equations and calculations necessary to describe this subsystem are given. The mechanization schematic and simulation diagram for obtaining the measured response parameters of the control system using an analog circuit are explained. Methods for investigating the various effects of the control parameters are described. It is concluded that the optimum system should be underdamped enough to be slightly oscillatory during transients.

Lalli, V. R.↗

Novel technique to measure the microwave response of high T(c) superconductors between 4.2 and 200 K

This paper describes a novel technique for measurements of the complex surface impedance Z(s) of high-T(c) superconductors over an extremely wide range of temperature, from 4.2 K and at least 200 K. The technique uses a superconducting Pb-plated Cu high-Q-cavity resonator operated at an ambient temperature of 4.2 K, with the sample (typically a 3-mm-diam x 1-mm-thick disk) mounted on a sapphire rod in the center of cavity, at a high B-field and thermally insulated from the cavity walls, making it possible to control the sample temperature externally. Since the cavity characteristics are dominated by the sample properties (the contribution of the Pb-covered walls maintained at 4.2 K is negligible), measurement of the cavity Q and resonant frequency makes it possible to measure Zs as a function of the sample temperature. The Z(s) values for bulk Y1Ba2Cu3O(y) and La(1.85)Sr(0.15)CuO4 were measured over a temperature range 4.2-100 K.

Sridhar, S.↗

Fast response densitometer for measuring liquid density

Densitometer was developed which produces linear voltage proportional to changes in density of flowing liquid hydrogen. Unit has fast response time and good system stability, statistical variation, and thermal equilibrium. System accuracy is 2 percent of total density span. Basic design may be altered to include measurement of other flowing materials.

Source record↗

Accelerator measurement of NaI response to medium energy neutrons and application to a satellite-borne spectrometer

We report on the response of a prototype detector to medium energy neutrons. The neutrons were produced by n-p scattering of a neutron beam on a hydrogen target. The measurements provide unique data on the efficiency and response of large NaI scintillators to neutrons in the energy range 36-709 MeV. We apply the results to the high-energy mode of the Gamma-Ray Spectrometer (GRS) on the Solar Maximum Mission satellite by estimating its efficiency for neutron detection. This estimate is compared to earlier Monte Carlo calculations of the GRS efficiency.

Dunphy, P. P.↗

Measurements of speed of response of high-speed visible and IR optical detectors

A technique for measuring speed of response of high speed visible and IR optical detectors to mode-locked Nd:YAG laser pulses is described. Results of measurements of response times of four detectors are presented. Three detectors that can be used as receivers in a 500-MHz optical communication system are tested.

Rowe, H. E.↗

Global ozone long-term trends from satellite measurements and the response to solar activity variations

Analysis of global ozone variations for the period April 1970 to December 1975 was performed by using the reprocessed Nimbus 4 backscattered ultraviolet (BUV) measurements of total ozone. A correlation coefficient of 0.97 is found between the 6-month running mean of global mean total ozone (filtered for mean semiannual, annual, and quasibiennial variations) and the 10.7-cm solar activity index. Correcting ozone for a time-dependent latitudinal bias relative to Dobson ozone measurements reduces to 2-3% the global mean ozone variation over the solar cycle. The solar ultraviolet variability required in a one-dimensional time-dependent radiative photochemical model to account for the observed ozone variation appears to be consistent with recent solar UV observations.

Keating, G. M.↗

Gated photomultiplier response characterization for DIAL measurements

The characteristics of various detector responses are studied to understand the cause of various systematic biases and to minimize these undesirable effects in measurements of transient signals with large dynamic range. Signal-induced bias, gain variation, and the linearity of commonly used gated photomultipliers in the current integrating mode are quantitatively evaluated. Analysis of the results indicates that impurity ions inside the photomultiplier tubes (PMT) are the source of the signal induced bias and gain variation. Two different PMTs used in this study show significant differences in the magnitude and decay behavior of signal-induced bias. It was found that it can be minimized by using an external amplifier to reduce PMT gain, and by applying a low potential between the cathode and first dynode. The linearity of a PMT is also studied over a large dynamic range of input intensities employing a new technique which does not require an absolute calibration. The result of this study shows that the photomultiplier response is linear only for a limited input intensity range below a certain anode current.

Lee, H. Sang↗

Prototype Ge:Ga detectors for the NASA-Ames cooled grating spectrometer

The detectors were fabricated from a Ge:Ga wafer from Eagle-Pitcher with a room temperature resistivity of approx. 12ohms cm. The wafer is approximately 2 inches in diameter and 0.061 inches thick. The contact material was ion implanted with Boron using 10 to the 14th power ions/sq cm at 25 Kev and 2 x10 to the 14th power ions/sq cm at 50 Kev. The crystal was then sputter-cleaned and metallized first with sputtered Ti and then sputter Au. In addition to the usual infrared measurements of responsivity and noise, measurements were made of the detectors' response to ionizing radiation.

Houck, J. R.↗

Comparison of the measured and predicted response of the Earth Radiation Budget Experiment active cavity radiometer during solar observations

The Earth Radiation Budget Experiment consists of an array of radiometric instruments placed in earth orbit by the National Aeronautics and Space Administration to monitor the longwave and visible components of the earth's radiation budget. Presented is a dynamic electrothermal model of the active cavity radiometer used to measure the earth's total radiative exitance. Radiative exchange is modeled using the Monte Carlo method and transient conduction is treated using the finite element method. Also included is the feedback circuit which controls electrical substitution heating of the cavity. The model is shown to accurately predict the dynamic response of the instrument during solar calibration.

Mahan, J. R.↗

A simple Fourier analysis technique for measuring the dynamic response of manual control systems.

From a practical standpoint most dynamic response analysis techniques are complicated, expensive, and time consuming to mechanize and operate. Adaptive parameter tracking techniques partially overcome these faults, but they have prescribed forms which is an undesirable restriction for basic research. To overcome these drawbacks, an on-line Fourier analysis technique has been developed which deals only with the input and error signals in a manual feedback control system. Several sine waves are used for the input, and the on-line data measurement includes the error variance and a simple means for obtaining the sine and cosine transforms of the error signal at each of the input frequencies. From this relatively small amount of data, we show simple ways to compute the open- and closed-loop dynamic response at input frequencies and the relative amount of linearly correlated power in the error signal.

Allen, R. W.↗