Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Simultaneous Measurements of Noncommuting Observables: Positive Transformations and Instrumental Lie Groups

We formulate a general program for describing and analyzing continuous, differential weak, simultaneous measurements of noncommuting observables, which focuses on describing the measuring instrument autonomously, without states. The Kraus operators of such measuring processes are time-ordered products of fundamental differential positive transformations, which generate nonunitary transformation groups that we call instrumental Lie groups. The temporal evolution of the instrument is equivalent to the diffusion of a Kraus-operator distribution function, defined relative to the invariant measure of the instrumental Lie group. This diffusion can be analyzed using Wiener path integration, stochastic differential equations, or a Fokker-Planck-Kolmogorov equation. This way of considering instrument evolution we call the Instrument Manifold Program. We relate the Instrument Manifold Program to state-based stochastic master equations. We then explain how the Instrument Manifold Program can be used to describe instrument evolution in terms of a universal cover that we call the universal instrumental Lie group, which is independent not just of states, but also of Hilbert space. The universal instrument is generically infinite dimensional, in which case the instrument’s evolution is chaotic. Special simultaneous measurements have a finite-dimensional universal instrument, in which case the instrument is considered principal, and it can be analyzed within the differential geometry of the universal instrumental Lie group. Principal instruments belong at the foundation of quantum mechanics. We consider the three most fundamental examples: measurement of a single observable, position and momentum, and the three components of angular momentum. As these measurements are performed continuously, they converge to strong simultaneous measurements. For a single observable, this results in the standard decay of coherence between inequivalent irreducible representations. For the latter two cases, it leads to a collapse within each irreducible representation onto the classical or spherical phase space, with the phase space located at the boundary of these instrumental Lie groups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Specifying Calibration of Energy-Measuring Equipment

Instruments and standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user expectations. This white paper reviews calibration terminology and standards, and describes best practices that have been developed for a) calibrating measurement equipment to ensure some known level of accuracy, and b) accrediting calibration service providers. Calibration is discussed in the context of metrological traceability, and excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently calibrate measuring equipment or who have new or changing needs for calibrating measuring equipment, rationale is provided for why a specification might be used to request calibration services that meet specific test needs. Given the growing interest in using data to manage the energy consumption of systems, and the increasing number and variety of systems (e.g., building, computing) that can report such information, use cases requiring energy data are used to facilitate further discussion and provide examples. Commercially available service providers who are accredited for energy-measuring equipment calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of energy-measuring-equipment test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

47 OTHER INSTRUMENTATION↗

Arctic Methane, Carbon Aerosols, and Tracers Study Field Campaign Report

The Arctic Methane, Carbon Aerosols, and Tracers Study was a measurement campaign at the National Oceanic and Atmospheric Administration (NOAA) Barrow Observatory and U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility North Slope of Alaska (NSA) sites in Barrow (formerly known as Utqiagvik) that involved the deployment of instruments to measure CH4, black carbon (BC), and source tracers. The campaign ran from September 1, 2014 to September 1, 2016 and was extended until July 30, 2017. We deployed an in situ instrument to measure methane, the ratio of its isotopologues 13CH4/12CH4, and ethane. We deployed a second instrument to measure carbon monoxide, carbonyl sulfide (COS), carbon dioxide, and water vapor. We also deployed an in situ instrument to measure BC, a single-particle soot photometer (SP2), at the nearby NOAA Barrow Observatory, co-located with the other NOAA aerosol instruments. Changes in emissions across different regions and seasons will be inferred using atmospheric transport and inverse modeling techniques.

North Slope of Alaska, trace gases, black carbon, ↗

Aethalometer™ Instrument Handbook

The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

54 ENVIRONMENTAL SCIENCES↗

Binary pseudo-random array (BPRA) for inspection and calibration for cylindrical wavefront interferometry

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. However, surface topography measurements are instrument dependent, and without the knowledge of how the instrument performs under the practical usage conditions, the measured data contain some degree of uncertainty. Binary Pseudo Random Array (BPRA) “white noise” artifact are effective and useful for characterizing the Instrument Transfer Function (ITF) of surface topography metrology tools and wavefront measurement instrument. BPRA artifact contains features with all spatial frequencies in the instrument bandpass with equal weight. As a result, power spectral density of the patterns has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range. The application examples include electron microscopes, x-ray microscopes, interferometric microscopes, and large field-of-view Fizeau Interferometers. Furthermore, we will introduce the application of BPRA method to characterizing the ITF of Cylindrical Wavefront Interferometry (CWI), by developing the BPRA artifact which matches the radius of curvature of the cylindrical wavefront. The data acquisition and analysis procedures for different applications of the ITF calibration technique developed are also discussed.

Munechika, K↗

Feasibility of using in situ deformation to monitor CO 2 storage

Deformation during CO 2 injection can lead to problems, like seismicity or fluid leaks, but small strains have the potential to be a useful signal for monitoring. The objective of this paper is to evaluate the possible evolution of the strain field during injection, and then assess existing and emerging techniques for measuring the strain field. Poroelastic analyses show that normal strains caused by injection into a reservoir are tensile in the vicinity of the well, but everywhere else at least one strain component is compressive. The vertical strain is compressive in the confining unit, and the radial strain decreases and changes sign from tensile to compressive with distance from the well. Tilting is away from the injection well at the ground surface, but it is towards the well overlying the reservoir. Methods for measuring in-situ strain include instruments that are grouted in the annulus between casing and wall rock (~ 0.1 microstrain resolution), portable strain sensors that are temporarily clamped to the borehole wall (~0.01 microstrain resolution), and strainmeters that are grouted in place (~0.001 microstrain resolution). Instruments for measuring in-situ normal strains at the magnitudes and rates expected during injection are emerging, but they have yet to be fully evaluated in applications related to CO 2 storage. Finally, in-situ strain data measured with emerging instruments promises to fill an important gap between the episodes of fast strain rates measured by seismic data, and the slow strains measured over relatively long periods of time by InSAR and GPS.

42 ENGINEERING↗

Video Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis: Preprint

This purely analytical work is based primarily on the geometric optics of the system and shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic trough test. In this paper, we include both the random (precision) and systematic (bias) errors for VSHOT testing and theircontributions to the uncertainty. The contributing factors that we considered in this study are target tilt, target face to laser output distance, instrument vertical offset, scanner tilt, distance between the tool and the test piece, camera calibration, and scanner/calibration.

14 SOLAR ENERGY↗

Calibration of a neutron time-of-flight detector with a rapid instrument response function for measurements of bulk fluid motion on OMEGA

A newly developed neutron time-of-flight (nTOF) diagnostic with a fast instrument response function has been fielded on the OMEGA laser in a highly collimated line of sight. In this study, by using a small plastic scintillator volume, the detector provides a narrow instrument response of 1.7 ns full width at half maximum while maintaining a large signal-to-noise ratio for neutron yields between 10 10 and 10 14 . The OMEGA hardware timing system is used along with an optical fiducial to provide an absolute nTOF measurement to an accuracy of ~56 ps. The fast instrument response enables the accurate measurement of the primary deuterium-tritium neutron peak shape, while the optical fiducial allows for an absolute neutron energy measurement. The new detector measures the neutron mean energy with an uncertainty of ~7 keV, corresponding to a hot-spot velocity projection uncertainty of ~12 km/s. Finally, evidence of bulk fluid motion in cryogenic targets is presented with measurements of the neutron energy spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visual Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis (Milestone Report)

In 1997, an uncertainty analysis was conducted of the Video Scanning Hartmann Optical Tester (VSHOT). In 2010, we have completed a new analysis, based primarily on the geometric optics of the system, and it shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic troughmirror panel test. These help to guide the operator in proper setup, and help end-users to understand the data they are provided. We include both the systematic (bias) and random (precision) errors for VSHOT testing and their contributions to the uncertainty. The contributing factors we considered in this study are: target tilt; target face to laser output distance; instrument vertical offset;laser output angle; distance between the tool and the test piece; camera calibration; and laser scanner. These contributing factors were applied to the calculated slope error, focal length, and test article tilt that are generated by the VSHOT data processing. Results show the estimated 2-sigma uncertainty in slope error for a parabolic trough line scan test to be +/-0.2 milliradians;uncertainty in the focal length is +/- 0.1 mm, and the uncertainty in test article tilt is +/- 0.04 milliradians.

14 SOLAR ENERGY↗

Holdup Measures on an SRNL Mossbauer Spectroscopy Instrument

Gamma-ray holdup measurements of a Mossbauer spectroscopy instrument are described and modeled. In the qualitative acquisitions obtained in a low background area of Savannah River National Laboratory, only Am-241 and Np-237 activity were observed. The Am-241 was known to be the instrumental activation source, while the Np-237 is clearly observed as a source of contamination internal to the instrument. The two sources of activity are modeled separately in two acquisition configurations using two separate modeling tools. The results agree well, demonstrating a content of (1980 {+-} 150) {mu}Ci Am-241 and (110 {+-} 50) {mu}Ci of Np-237.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A new stereolithography experimental porous flow device

A new method for constructing laboratory-scale porous media with increased pore-level variabilities for two-phase flow experiments is presented here. These devices have been created with stereolithography directly on glass, thus improving the stability of the model created with this precision rapid construction technique. The method of construction and improved parameters are discussed in detail, followed by a brief comparison of two-phase drainage results for air invasion into the water-saturated porous medium. Flow through the model porous medium is shown to substantiate theoretical fractal predictions.

47 OTHER INSTRUMENTATION↗

A small-volume, high-throughput approach for surface tension and viscosity measurements of liquid fuels

An ongoing effort looking at bioblendstocks to function as drop-in replacements or blending components for gasoline has identified a large number of candidate fuels. This work documents an approach for rapid screening of candidate fuels using relatively small sample sizes ($\mathcal{O}(\mu\,{\rm l})$) that targets two key physical properties of liquid fuels—surface tension and viscosity. The approach utilizes shape oscillation dynamics of single droplets generated by a piezo-electric device and their decay over time. Strobed imaging of the oscillation process is used along with image processing, edge detection, and data analysis to capture the decay of the oscillation over time. The time constant of the decay process along with oscillation frequency are then used to estimate viscosity and surface tension using a theory for small amplitude droplet oscillations. Measurements are obtained for primary reference fuels (isooctane and n-heptane) as well as candidate fuels from four bio-derived functional groups of interest. Measurement results for surface tension and viscosity are correlated with literature data as well as measurements from standard reference instruments. The measurement results show that the droplet oscillation based approach is capable of reproducing surface tension and viscosity values for the tested fuels within deviations of 7% and 13% respectively from literature data. Results are obtained using an average of 5 µl per fuel within about 20 s, thus demonstrating a small-volume, high-throughput approach that can be used for screening of candidate bioblendstock fuels.

09 BIOMASS FUELS↗

Large volume high-pressure cell with supported moissanite anvils

The recently developed moissanite anvil cell (MAC) has become a useful device for achieving both high-pressure and large sample volume in an anvil cell. We describe two improvements in the basic design of the MAC. First, the loading environment has been optimized by centering the load. Second, a variety of supported systems have been examined to provide anvil stability at high loads with large anvils. Sample volumes that are nearly three orders magnitude greater than allowed by conventional diamond anvil cells can be pressurized and characterized at {approx}50 GPa.

47 OTHER INSTRUMENTATION↗

Fast response High Altitude Laser Optical Sensor (HALOS) for atmospheric water and temperature measurements

Advanced instrumentation and sensing methods are the key factor in the determination of many climate science research problems. In this Phase I STTR a laser-based diagnostic system for atmospheric temperature and water concentrations measurements was developed, this system, HALOS – High Altitude Laser Optical Sensor, employs a mid-infrared (MIR) quantum cascade laser (QCL) of the distributed feedback variety (DFB) powered by a 100 kHz rep rate ramp modulated current profile which enables spectral profiling. Measurements made during Phase I showed that HALOS can surpass the available hygrometers refresh rates while offering superior accuracy (<4%) from the low Frost Point (Tfrost) of -110°C to dew points (Tdew) at 35°C while being able to encompass sub ppm concentration at altitude and supersaturated conditions at ground level. Readings from HALOS include temperature sensitivity on the order of 0.2°C and absolute humidity sensitivity (AH) on the order of 0.010 μmol/m 3 (0.18 mg/m 3 ) at a data output rate exceeding 1 kHz. HALOS can be easily integrable in existing Department of Energy (DOE) or National Oceanic and Atmospheric Administration (NOAA) conventional or remote operated aircraft having either a fixed or rotary wing.

54 ENVIRONMENTAL SCIENCES↗

Suprathermal plasma analyzer for the measurement of low-energy electron distribution in the ionosphere

It is commonly believed that an energy transfer from thermal to suprathermal electrons (<several eV) greatly affects the energy budget of the ionosphere. However, observation of electron energy spectrum in this energy range is quite limited because of technical difficulties of measurement. We have developed an instrument to measure electron energy distribution from thermal to suprathermal energy continuously with high-energy resolution of about 0.15 eV. The measurement principle is based on the combination of a retarding potential analyzer with a channel electron multiplier (CEM) and the Druyvesteyn method, which derives energy distribution from the current-voltage characteristics. The capability of detecting plasma space potential enables absolute calibration of electron energy. The instrument with a small vacuum pump, which is required for the CEM to work in low-vacuum region, was first successfully tested by a sounding rocket S-310-37 in the ionospheric E region. The instrument is expected to provide new opportunities to measure energy distribution of thermal and non-thermal electrons in low-density plasma, where a Langmuir probe cannot measure electron temperature because of low plasma density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE TOTAL SOLAR IRRADIANCE CLIMATE DATA RECORD

We present the composite measurements of total solar irradiance (TSI) as measured by an ensemble of space instruments. The measurements of the individual instruments are put on a common absolute scale, and their quality is assessed by intercomparison. The composite time series is the average of all available measurements. From 1984 April to the present the TSI shows a variation in phase with the 11 yr solar cycle and no significant changes of the quiet-Sun level in between the three covered solar minima.

79 ASTRONOMY AND ASTROPHYSICS↗