Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microcomputers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

An extreme ultraviolet spectrometer experiment for the Shuttle Get Away Special Program

An extreme ultraviolet (EUV) spectrometer experiment operated successfully during the STS-7 mission in an experiment to measure the global and diurnal variation of the EUV airglow. The spectrometer is an F 3.5 Wadsworth mount with mechanical collimator, a 75 x 75 mm grating, and a bare microchannel plate detector providing a spectral resolution of 7 X FWHM. Read-out of the signal is through discrete channels or resistive anode techniques. The experiment includes a microcomputer, 20 Mbit tape recorder, and a 28V, 40 Ahr silver-zinc battery. It is the first GAS payload to use an opening door. The spectrometer's 0.1 x 4.2 deg field of view is pointed vertically out of the shuttle bay. During the STS-7 flight data were acquired continuously for a period of 5 hours and 37 minutes, providing spectra of the 570 A to 850 A wavelength region of the airglow. Five diurnal cycles of the 584 A emission of neutral helium and the 834 A emission of ionized atomic oxygen were recorded. The experiment also recorded ion events and pressure pulses associated with thruster firings. The experiment is to fly again on Mission 41-F.

Conway, R. R.↗

Astronomical application of IR CID technology

A portable microcomputer data system was developed to test a 2 x 64-element Si:Bi charge injection device (CID) infrared detector array on the Lick Observatory Shane telescope. An existing 0.5 m spectrograph was used for the tests after modification, and a spectral resolution of 1000 was achieved. Slow device response, due to the low background conditions in the spectrograph were shown. Astronomical data were later obtained, and a device read noise on the order of a few hundred electrons was achieved. The signal to noise ratios of the resulting spectra were about a factor of five lower than what could have been achieved with discrete photoconductive detectors. It is concluded that the CID array is competitive for applications in backgrounds lower than those used in the tests.

Rank, D. M.↗

Programming for energy monitoring/display system in multicolor lidar system research

The Z80 microprocessor based computer program that directs and controls the operation of the six channel energy monitoring/display system that is a part of the NASA Multipurpose Airborne Differential Absorption Lidar (DIAL) system is described. The program is written in the Z80 assembly language and is located on EPROM memories. All source and assembled listings of the main program, five subroutines, and two service routines along with flow charts and memory maps are included. A combinational block diagram shows the interfacing (including port addresses) between the six power sensors, displays, front panel controls, the main general purpose minicomputer, and this dedicated microcomputer system.

Alvarado, R. C., Jr.↗

Preliminary design study of a higher harmonic blade feathering control system

The feasibility to incorporate an active higher harmonic control (HHC) system on an OH-6A rotorcraft was demonstrated. The introduction of continuously modulated low amplitude 4P feathering showed potential for reducing rotor transmitted oscillatory loads. The design implementation of this system on a baseline OH-6A required generation of a hydraulic power system, control actuator placement and design integration of an electronic subsystem comprised of an electronic control unit (ECU) and digital microcomputer. Various placements of the HHC actuators in the primary control system are evaluated. Assembly drawings of the actuator concepts and control rigging are presented. The advantages of generating both hydraulic power and 4F control motions in the nonrotating system is confirmed.

Powers, R. W.↗

A Battery Charger and State of Charge Indicator

A battery charger which has a full wave rectifier in series with a transformer isolated 20 kHz dc-dc converter with high frequency switches, which are programmed to actively shape the input dc line current to be a mirror image of the ac line voltage is discussed. The power circuit operates at 2 kW peak and 1 kW average power. The BC/SCI has two major subsystems: (1) the battery charger power electronics with its controls; and (2) a microcomputer subsystem which is used to acquire battery terminal data and exercise the state of charge software programs. The state of charge definition employed is the energy remaining in the battery when extracted at a 10 kW rate divided by the energy capacity of a fully charged new battery. The battery charger circuit is an isolated boost converter operating at an internal frequency of 20 kHz. The switches selected for the battery charger are the single most important item in determining its efficiency. The combination of voltage and current requirements dictate the use of high power NPN Darlington switching transistors. The power circuit topology is a three switch design which utilizes a power FET on the center tap of the isolation transformer and the power Darlingtons on each of the two ends. An analog control system is employed to accomplish active input current waveshaping as well as the necessary regulation.

Latos, T. S.↗

Development and fabrication of a solar cell junction processing system

A processing system capable of producing solar cell junctions by ion implantation followed by pulsed electron beam annealing was developed and constructed. The machine was to be capable of processing 4-inch diameter single-crystal wafers at a rate of 10(7) wafers per year. A microcomputer-controlled pulsed electron beam annealer with a vacuum interlocked wafer transport system was designed, built and demonstrated to produce solar cell junctions on 4-inch wafers with an AMI efficiency of 12%. Experiments showed that a non-mass-analyzed (NMA) ion beam could implant 10 keV phosphorous dopant to form solar cell junctions which were equivalent to mass-analyzed implants. A NMA ion implanter, compatible with the pulsed electron beam annealer and wafer transport system was designed in detail but was not built because of program termination.

Source record↗

Electronic 4-wheel drive control device

The internal rotation torque generated during operation of a 4-wheel drive vehicle is reduced using a control device whose clutch is attached to one part of the rear-wheel drive shaft. One torque sensor senses the drive torque associated with the rear wheel drive shaft. A second sensor senses the drive torque associated with the front wheel drive shaft. Revolution count sensors sense the revolutions of each drive shaft. By means of a microcomputer, the engagement of the clutch is changed to insure that the ratio of the torque sensors remains constant.

Hayato, S.↗

A new approach to implementing spacecraft power system autonomy

Discussed in this paper are some of the problems associated with implementing microcomputer-based power system autonomy on spacecraft flight projects, as well as limitations derived from prior development programs. A new approach is given for developing the autonomy architecture, and an architecture concept, based on that approach, is described.

Bridgeforth, A. O.↗

Parallelism and pipelining in high-speed digital simulators

The attainment of high computing speed as measured by the computational throughput is seen as one of the most challenging requirements. It is noted that high speed is cardinal in several distinct classes of applications. These classes are then discussed; they comprise (1) the real-time simulation of dynamic systems , (2) distributed parameter systems, and (3) mixed lumped and distributed systems. From the 1950s on, the quest for high speed in digital simulators concentrated on overcoming the limitations imposed by the so-called von Neumann bottleneck. Two major architectural approaches have made ig possible to circumvent this bottleneck and attain high speeds. These are pipelining and parallelism. Supercomputers, peripheral array processors, and microcomputer networks are then discussed.

Karplus, W. J.↗

Digital data-acquisition system for measuring the free decay of acoustical standing waves in a resonant tube

A low-cost digital system based on an 8-bit Apple II microcomputer has been designed to provide on-line control, data acquisition, and evaluation of sound absorption measurements in gases. The measurements are conducted in a resonant tube, in which an acoustical standing wave is excited, the excitation removed, and the sound absorption evaluated from the free decay envelope. The free decay is initiated from the computer keyboard after the standing wave is established, and the microphone response signal is the source of the analog signal for the A/D converter. The acquisition software is written in ASSEMBLY language and the evaluation software in BASIC. This paper describes the acoustical measurement, hardware, software, and system performance and presents measurements of sound absorption in air as an example.

Meredith, R. W.↗

Impact of new computing systems on finite element computations

Recent advances in computer technology that are likely to impact finite element computations are reviewed. The characteristics of supersystems, highly parallel systems, and small systems (mini and microcomputers) are summarized. The interrelations of numerical algorithms and software with parallel architectures are discussed. A scenario is presented for future hardware/software environment and finite element systems. A number of research areas which have high potential for improving the effectiveness of finite element analysis in the new environment are identified.

Noor, A. K.↗

Surface fluctuation spectroscopy - A novel technique for characterizing liquid interfaces

Surface fluctuation spectroscopy is a dynamic light scattering technique which involves the detection of thermal fluctuations (capillary waves) that cover every liquid interface. The advantages of this technique over conventional mechanical methods are discussed. The signal resolution and precision are improved by using a grating heterodyne technique coupled with a digital correlator. Detailed calculations showed that, for the measured power spectrum (the Fourier transform of the correlation function) to take the Lorentzian shape, it is necessary that certain optical conditions be met. These conditions are demonstrated with experimental data collected for ethanol at the ambient temperature as a function of the wave number. Once the optical parameters are adjusted correctly, the experimental results show excellent agreement with the literature values. It is also demonstrated that, using microcomputer technology, the entire system can be automated.

Shih, L. B.↗

Long-term orbit prediction for the Venus Radar Mapper Mission using an averaging method

A set of singly averaged equations of motion are presented and applied to long-term orbit prediction of an orbiting spacecraft around a slowly rotating planet, using the Venus Radar Mapper Mission as an example. The equations of motion used are valid for all eccentricities less than one. The disturbing potentials used include nonsphericity of the Venus gravity field and third-body effects due to the sun. Recursive relationships are used in the expansion and evaluation of these potentials and their respective partial derivatives. Special care is taken to optimize computational efficiency. The averaging method is compared with high precision Cowell's method using a desktop microcomputer and shows computational saving of about two orders of magnitude.

Kwok, J. H.↗

Integrated remote sensing of the earth from low earth orbit in the 1990's

Trends in the areas of science, data systems, instruments and space technologies and their related infrastructures that will be experienced in earth remote sensing activities from LEO in the 1990s are discussed. Interdisciplinary studies will examine the flow of energy through the earth system, encompassing surveys of atmospheric and ocean circulations, the hydrologic cycle, and biogeochemical cycles. Mainframe computer assimilation of large data inputs will be associated with distributed microcomputer processing and analyses. Single satellite antennas will scan several microwave frequencies simultaneously, e.g., taking data on vegetation, water, and ice. Broadening the range of simultaneous observations will require multiinstrumented free-flying platforms, placed in orbit, repaired and/or retrieved by the Shuttle. Future instrumentation will include visible/IR imagers and the multifrequency microwave sounders with capabilities mainly limited by the availability of sufficient data-handling facilities.

Butler, D. M.↗

Zone Refining by Laser

System developed for studying use of laser beam for zone-refining semiconductors and metals. Specimen scanned with focused CO2 laser beam in such way that thin zone of molten material moves along specimen sweeps impurities with it. Zone-melting system comprises microcomputer, laser, electromechanical and optical components for beam control, vacuum chamber that holds specimen, and sensor for determining specimen temperature.

Griner, D. B.↗

Image-Processing Educator

Apple Image-Processing Educator (AIPE) explores ability of microcomputers to provide personalized computer-assisted instruction (CAI) in digital image processing of remotely sensed images. AIPE is "proof-of-concept" system, not polished production system. User-friendly prompts provide access to explanations of common features of digital image processing and of sample programs that implement these features.

Gunther, F. J.↗

Hardware for a real-time multiprocessor simulator

The hardware for a real time multiprocessor simulator (RTMPS) developed at the NASA Lewis Research Center is described. The RTMPS is a multiple microprocessor system used to investigate the application of parallel processing concepts to real time simulation. It is designed to provide flexible data exchange paths between processors by using off the shelf microcomputer boards and minimal customized interfacing. A dedicated operator interface allows easy setup of the simulator and quick interpreting of simulation data. Simulations for the RTMPS are coded in a NASA designed real time multiprocessor language (RTMPL). This language is high level and geared to the multiprocessor environment. A real time multiprocessor operating system (RTMPOS) has also been developed that provides a user friendly operator interface. The RTMPS and supporting software are currently operational and are being evaluated at Lewis. The results of this evaluation will be used to specify the design of an optimized parallel processing system for real time simulation of dynamic systems.

Blech, R. A.↗

Concentrator optical characterization using computer mathematical modelling and point source testing

The optical characteristics of a paraboloidal solar concentrator are analyzed using the intercept factor curve (a format for image data) to describe the results of a mathematical model and to represent reduced data from experimental testing. This procedure makes it possible not only to test an assembled concentrator, but also to evaluate single optical panels or to conduct non-solar tests of an assembled concentrator. The use of three-dimensional ray tracing computer programs to calculate the mathematical model is described. These ray tracing programs can include any type of optical configuration from simple paraboloids to array of spherical facets and can be adapted to microcomputers or larger computers, which can graphically display real-time comparison of calculated and measured data.

Dennison, E. W.↗