Search NASA⌕ Search

SEARCH · Search NASA

Results for “Middle Aged”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Cerebral vasoconstriction precedes orthostatic intolerance after parabolic flight

The effects of brief but repeated bouts of micro- and hypergravity on cerebrovascular responses to head-up tilt (HUT) were examined in 13 individuals after (compared to before) parabolic flight. Middle cerebral artery mean flow velocity (MCA MFV; transcranial Doppler ultrasound), eye level blood pressure (BP) and end tidal CO(2) (P(ET)CO(2)) were measured while supine and during 80 degrees HUT for 30 min or until presyncope. In the postflight tests subjects were classified as being orthostatically tolerant (OT) (n = 7) or intolerant (OI) (n = 6). BP was diminished with HUT in the OT group in both tests (p < 0.05) whereas postflight BP was not different from supine in the OI group. Postflight compared to preflight, the reduction in P(ET)CO(2) with HUT (p < 0.05) increased in both groups, although significantly so only in the OI group (p < 0.05). The OI group also had a significant decrease in supine MCA MFV postflight (p < 0.05) that was unaccompanied by a change in supine P(ET)CO(2). The decrease in MCA MFV that occurred during HUT in both groups preflight (p < 0.05) was accentuated only in the OI group postflight, particularly during the final 30 s of HUT (p < 0.05). However, this accentuated decrease in MCA MFV was not correlated to the greater decrease in P(ET)CO(2) during the same period (R = 0.20, p = 0.42). Although cerebral vascular resistance (CVR) also increased in the OI group during the last 30 s of HUT postflight (p < 0.05), the dynamic autoregulatory gain was not simultaneously changed. Therefore, we conclude that in the OI individuals, parabolic flight was associated with cerebral hypoperfusion following a paradoxical augmentation of CVR by a mechanism that was not related to changes in autoregulation nor strictly to changes in P(ET)CO(2).

Parabolic Flight↗

Transient cardio-respiratory responses to visually induced tilt illusions

Although the orthostatic cardio-respiratory response is primarily mediated by the baroreflex, studies have shown that vestibular cues also contribute in both humans and animals. We have demonstrated a visually mediated response to illusory tilt in some human subjects. Blood pressure, heart and respiration rate, and lung volume were monitored in 16 supine human subjects during two types of visual stimulation, and compared with responses to real passive whole body tilt from supine to head 80 degrees upright. Visual tilt stimuli consisted of either a static scene from an overhead mirror or constant velocity scene motion along different body axes generated by an ultra-wide dome projection system. Visual vertical cues were initially aligned with the longitudinal body axis. Subjective tilt and self-motion were reported verbally. Although significant changes in cardio-respiratory parameters to illusory tilts could not be demonstrated for the entire group, several subjects showed significant transient decreases in mean blood pressure resembling their initial response to passive head-up tilt. Changes in pulse pressure and a slight elevation in heart rate were noted. These transient responses are consistent with the hypothesis that visual-vestibular input contributes to the initial cardiovascular adjustment to a change in posture in humans. On average the static scene elicited perceived tilt without rotation. Dome scene pitch and yaw elicited perceived tilt and rotation, and dome roll motion elicited perceived rotation without tilt. A significant correlation between the magnitude of physiological and subjective reports could not be demonstrated.

NASA Center JSC↗

Effects of pH and dose on nasal absorption of scopolamine hydrobromide in human subjects

PURPOSE: The present study was conducted to evaluate the effects of formulation pH and dose on nasal absorption of scopolamine hydrobromide, the single most effective drug available for the prevention of nausea and vomiting induced by motion sickness. METHODS: Human subjects received scopolamine nasally at a dose of 0.2 mg/0.05 mL or 0.4 mg/0.10 mL, blood samples were collected at different time points, and plasma scopolamine concentrations were determined by LC-MS/MS. RESULTS: Following administration of a 0.2 mg dose, the average Cmax values were found to be 262+/-118, 419+/-161, and 488+/-331 pg/ mL for pH 4.0, 7.0, and 9.0 formulations, respectively. At the 0.4 mg dose the average Cmax values were found to be 503+/-199, 933+/-449, and 1,308+/-473 pg/mL for pH 4.0, 7.0, and 9.0 formulations, respectively. At a 0.2 mg dose, the AUC values were found to be 23,208+/-6,824, 29,145+/-9,225, and 25,721+/-5,294 pg x min/mL for formulation pH 4.0, 7.0, and 9.0, respectively. At a 0.4 mg dose, the average AUC value was found to be high for pH 9.0 formulation (70,740+/-29,381 pg x min/mL) as compared to those of pH 4.0 (59,573+/-13,700 pg x min/mL) and pH 7.0 (55,298+/-17,305 pg x min/mL) formulations. Both the Cmax and AUC values were almost doubled with doubling the dose. On the other hand, the average Tmax, values decreased linearly with a decrease in formulation pH at both doses. For example, at a 0.4 mg dose, the average Tmax values were 26.7+/-5.8, 15.0+/-10.0, and 8.8+/-2.5 minutes at formulation pH 4.0, 7.0, and 9.0, respectively. CONCLUSIONS: Nasal absorption of scopolamine hydrobromide in human subjects increased substantially with increases in formulation pH and dose.

Controlled Clinical Trial↗

Quantifying ataxia: ideal trajectory analysis--a technical note

We describe a quantitative method to assess repeated stair stepping stability. In both the mediolateral (ML) and anterioposterior (AP) directions, the trajectory of the subject's center of mass (COM) was compared to an ideal sinusoid. The two identified sinusoids were unique in each direction but coupled. Two dimensionless numbers-the mediolateral instability index (IML) and AP instability index (IAP)-were calculated using the COM trajectory and ideal sinusoids for each subject with larger index values resulting from less stable performance. The COM trajectories of nine nonimpaired controls and six patients diagnosed with unilateral or bilateral vestibular labyrinth hypofunction were analyzed. The average IML and IAP values of labyrinth disorder patients were respectively 127% and 119% greater than those of controls (p<0.014 and 0.006, respectively), indicating that the ideal trajectory analysis distinguishes persons with labyrinth disorder from those without. The COM trajectories also identify movement inefficiencies attributable to vestibulopathy.

Non-NASA Center↗

Neural processing of gravito-inertial cues in humans. I. Influence of the semicircular canals following post-rotatory tilt

Sensory systems often provide ambiguous information. Integration of various sensory cues is required for the CNS to resolve sensory ambiguity and elicit appropriate responses. The vestibular system includes two types of sensors: the semicircular canals, which measure head rotation, and the otolith organs, which measure gravito-inertial force (GIF), the sum of gravitational force and inertial force due to linear acceleration. According to Einstein's equivalence principle, gravitational force is indistinguishable from inertial force due to linear acceleration. As a consequence, otolith measurements must be supplemented with other sensory information for the CNS to distinguish tilt from translation. The GIF resolution hypothesis states that the CNS estimates gravity and linear acceleration, so that the difference between estimates of gravity and linear acceleration matches the measured GIF. Both otolith and semicircular canal cues influence this estimation of gravity and linear acceleration. The GIF resolution hypothesis predicts that inaccurate estimates of both gravity and linear acceleration can occur due to central interactions of sensory cues. The existence of specific patterns of vestibuloocular reflexes (VOR) related to these inaccurate estimates can be used to test the GIF resolution hypothesis. To investigate this hypothesis, we measured eye movements during two different protocols. In one experiment, eight subjects were rotated at a constant velocity about an earth-vertical axis and then tilted 90 degrees in darkness to one of eight different evenly spaced final orientations, a so-called "dumping" protocol. Three speeds (200, 100, and 50 degrees /s) and two directions, clockwise (CW) and counterclockwise (CCW), of rotation were tested. In another experiment, four subjects were rotated at a constant velocity (200 degrees /s, CW and CCW) about an earth-horizontal axis and stopped in two different final orientations (nose-up and nose-down), a so-called "barbecue" protocol. The GIF resolution hypothesis predicts that post-rotatory horizontal VOR eye movements for both protocols should include an "induced" VOR component, compensatory to an interaural estimate of linear acceleration, even though no true interaural linear acceleration is present. The GIF resolution hypothesis accurately predicted VOR and induced VOR dependence on rotation direction, rotation speed, and head orientation. Alternative hypotheses stating that frequency segregation may discriminate tilt from translation or that the post-rotatory VOR time constant is dependent on head orientation with respect to the GIF direction did not predict the observed VOR for either experimental protocol.

Non-NASA Center↗

Holter monitoring: are two days better than one?

The optimal duration of Holter monitoring (HM) to minimize costs and maximize yield is unknown. In a retrospective review of 164 patients referred to a tertiary care center for evaluation with 2 days of HM, we found that 48 hours was not cost effective when compared with the traditional 24-hour period.

NASA Discipline Cardiopulmonary↗

Dissociation of muscle sympathetic nerve activity and leg vascular resistance in humans

We examined the hypothesis that the increase in inactive leg vascular resistance during forearm metaboreflex activation is dissociated from muscle sympathetic nerve activity (MSNA). MSNA (microneurography), femoral artery mean blood velocity (FAMBV, Doppler), mean arterial pressure (MAP), and heart rate (HR) were assessed during fatiguing static handgrip exercise (SHG, 2 min) followed by posthandgrip ischemia (PHI, 2 min). Whereas both MAP and MSNA increase during SHG, the transition from SHG to PHI is characterized by a transient reduction in MAP but sustained elevation in MSNA, facilitating separation of these factors in vivo. Femoral artery vascular resistance (FAVR) was calculated (MAP/MBV). MSNA increased by 59 +/- 20% above baseline during SHG (P < 0.05) and was 58 +/- 18 and 78 +/- 18% above baseline at 10 and 20 s of PHI, respectively (P < 0.05 vs. baseline). Compared with baseline, FAVR increased 51 +/- 22% during SHG (P < 0.0001) but returned to baseline levels during the first 30 s of PHI, reflecting the changes in MAP (P < 0.005) and not MSNA. It was concluded that control of leg muscle vascular resistance is sensitive to changes in arterial pressure and can be dissociated from sympathetic factors.

Non-NASA Center↗

Arctic cognition: a study of cognitive performance in summer and winter at 69 degrees N

Evidence has accumulated over the past 15 years that affect in humans is cyclical. In winter there is a tendency to depression, with remission in summer, and this effect is stronger at higher latitudes. In order to determine whether human cognition is similarly rhythmical, this study investigated the cognitive processes of 100 participants living at 69 degrees N. Participants were tested in summer and winter on a range of cognitive tasks, including verbal memory, attention and simple reaction time tasks. The seasonally counterbalanced design and the very northerly latitude of this study provide optimal conditions for detecting impaired cognitive performance in winter, and the conclusion is negative: of five tasks with seasonal effects, four had disadvantages in summer. Like the menstrual cycle, the circannual cycle appears to influence mood but not cognition.

Cognition↗

Quantitative computed tomography for spinal mineral assessment: current status

Quantitative CT (QCT) is an established method for the noninvasive assessment of bone mineral content in the vertebral spongiosum and other anatomic locations. The potential strengths of QCT relative to dual photon absorptiometry (DPA) are its capability for precise three-dimensional anatomic localization providing a direct density measurement and its capability for spatial separation of highly responsive cancellous bone from less responsive cortical bone. The extraction of this quantitative information from the CT image, however, requires sophisticated calibration and positioning techniques and careful technical monitoring.

Lumbar Vertebrae/radiography↗

Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies

OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.

NASA Discipline Cardiopulmonary↗

Stress-induced reactivation of Epstein-Barr virus in astronauts

Herpesviruses are leading causes of infectious blindness and death in immunocompromised individuals. Impaired cellular immunity, which is known to result in increased frequency and severity of herpesvirus infections, has been demonstrated both during and after spaceflight. Therefore, we examined whether Epstein-Barr virus (EBV), a well-characterized latent herpesvirus, undergoes reactivation in astronauts. Sera from Shuttle astronauts, taken before and after spaceflight, were examined for evidence of EBV reactivation. The geometric mean antibody titer to EBV viral capsid antigen (VCA) was significantly increased prior to flight compared to baseline (p = 0. 0001). After spaceflight, evidence of acute lytic replication was found in which 8- to 64-fold increases in EBV early antigen (EA) antibodies occurred without significant increases in antibodies to measles virus. Additionally, stress-induced shifts in circulating leukocytes and elevated levels of urinary cortisol and epinephrine were found. Overall, significant increases in EA or high VCA/EA antibody titers were found in 8 of 23 (35%) male astronauts and 3 of 5 (60%) female astronauts. These results indicate that stress reactivates EBV prior to flight and suggest that acute lytic replication of EBV occurs during spaceflight. Copyright 2000 S. Karger AG, Basel.

NASA Discipline Environmental Health↗

[Correction of autonomic reactions parameters in organism of cosmonaut with adaptive biocontrol method]

Presented are results of testing the method of adaptive biocontrol during preflight training of cosmonauts. Within the MIR-25 crew, a high level of controllability of the autonomous reactions was characteristic of Flight Commanders MIR-23 and MIR-25 and flight Engineer MIR-23, while Flight Engineer MIR-25 displayed a weak intricate dependence of these reactions on the depth of relaxation or strain.

Flight Experiment↗

Doppler echo evaluation of pulmonary venous-left atrial pressure gradients: human and numerical model studies

The simplified Bernoulli equation relates fluid convective energy derived from flow velocities to a pressure gradient and is commonly used in clinical echocardiography to determine pressure differences across stenotic orifices. Its application to pulmonary venous flow has not been described in humans. Twelve patients undergoing cardiac surgery had simultaneous high-fidelity pulmonary venous and left atrial pressure measurements and pulmonary venous pulsed Doppler echocardiography performed. Convective gradients for the systolic (S), diastolic (D), and atrial reversal (AR) phases of pulmonary venous flow were determined using the simplified Bernoulli equation and correlated with measured actual pressure differences. A linear relationship was observed between the convective (y) and actual (x) pressure differences for the S (y = 0.23x + 0.0074, r = 0.82) and D (y = 0.22x + 0.092, r = 0.81) waves, but not for the AR wave (y = 0. 030x + 0.13, r = 0.10). Numerical modeling resulted in similar slopes for the S (y = 0.200x - 0.127, r = 0.97), D (y = 0.247x - 0. 354, r = 0.99), and AR (y = 0.087x - 0.083, r = 0.96) waves. Consistent with numerical modeling, the convective term strongly correlates with but significantly underestimates actual gradient because of large inertial forces.

Non-NASA Center↗

Treatment of hypertension with perindopril reduces plasma atrial natriuretic peptide levels, left ventricular mass, and improves echocardiographic parameters of diastolic function

BACKGROUND: Hypertension is a major independent risk factor for cardiac deaths, and diastolic dysfunction is a usual finding during the course of this disease. HYPOTHESIS: This study was designed to investigate the effects of chronic therapy with perindopril on left ventricular (LV) mass, left atrial size, diastolic function, and plasma level of atrial natriuretic peptide (ANP) in patients with hypertension. METHODS: Twenty four patients who had not been previously taking any antihypertensive medication and without prior history of angina pectoris, myocardial infarction, congestive heart failure, dysrhythmias, valvular heart disease, or systemic illnesses received 4-8 mg/day of perindopril orally. Echocardiographic studies were acquired at baseline and 6 months after the initiation of therapy. RESULTS: Systolic and diastolic blood pressure decreased from 174 +/- 19.7 and 107.5 +/- 7.8 mmHg to 134 +/- 10.6 and 82 +/- 6.7 mmHg, respectively (p < 0.001). Left ventricular mass decreased from 252.4 +/- 8.3 to 205.7 +/- 7.08 g and left atrial volume from 20.4 +/- 5.1 to 17.6 +/- 5.2 ml, respectively (p < 0.001). Transmitral Doppler early and atrial filling velocity ratio (E/A) increased from 0.69 +/- 0.06 to 0.92 +/- 0.05 m/s and plasma ANP level decreased from 71.9 +/- 11.7 to 35.3 +/- 7.8 pg/ml (p < 0.001). Reduction of LV mass correlated positively with a reduction in ANP levels (r = 0.66, p < 0.0005). CONCLUSIONS: Perindopril caused a significant reduction of LV mass, left atrial volume, and plasma ANP levels, as well as improvement in Doppler parameters of LV filling in this group of patients with hypertension.

NASA Program Biomedical Research and Countermeasur↗

Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

NASA Discipline Cardiopulmonary↗

Multimodality stereotactic brain tissue identification: the NASA smart probe project

Real-time tissue identification can benefit procedures such as stereotactic brain biopsy, functional neurosurgery and brain tumor excision. Optical scattering spectroscopy has been shown to be effective at discriminating cancer from noncancerous conditions in the colon, bladder and breast. The NASA Smart Probe extends the concept of 'optical biopsy' by using neural network techniques to combine the output from 3 microsensors contained within a cannula 2. 7 mm in diameter (i.e. the diameter of a stereotactic brain biopsy needle). Experimental data from 5 rats show the clear differentiation between tissues such as brain, nerve, fat, artery and muscle that can be achieved with optical scattering spectroscopy alone. These data and previous findings with other modalities such as (1) analysis of the image from a fiberoptic neuroendoscope and (2) the output from a microstrain gauge suggest the Smart Probe multiple microsensor technique shows promise for real-time tissue identification in neurosurgical procedures. Copyright 2000 S. Karger AG, Basel.

Non-programmatic↗

Dynamic markers of altered gait rhythm in amyotrophic lateral sclerosis

Amyotrophic lateral sclerosis (ALS) is a disorder marked by loss of motoneurons. We hypothesized that subjects with ALS would have an altered gait rhythm, with an increase in both the magnitude of the stride-to-stride fluctuations and perturbations in the fluctuation dynamics. To test for this locomotor instability, we quantitatively compared the gait rhythm of subjects with ALS with that of normal controls and with that of subjects with Parkinson's disease (PD) and Huntington's disease (HD), pathologies of the basal ganglia. Subjects walked for 5 min at their usual pace wearing an ankle-worn recorder that enabled determination of the duration of each stride and of stride-to-stride fluctuations. We found that the gait of patients with ALS is less steady and more temporally disorganized compared with that of healthy controls. In addition, advanced ALS, HD, and PD were associated with certain common, as well as apparently distinct, features of altered stride dynamics. Thus stride-to-stride control of gait rhythm is apparently compromised with ALS. Moreover, a matrix of markers based on gait dynamics may be useful in characterizing certain pathologies of motor control and, possibly, in quantitatively monitoring disease progression and evaluating therapeutic interventions.

NASA Program Biomedical Research and Countermeasur↗