Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mixture separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Molecular Recognition with Resolution Below 0.2 Angstroms Through Thermoregulatory Oscillations in Covalent Organic Frameworks

Crystalline materials with uniform molecular-sized pores are desirable for a broad range of applications, such as sensors, catalysis, and separations. However, it is challenging to tune the pore size of a single material continuously and to reversibly distinguish small molecules (below 4 angstroms). We synthesized a series of ionic covalent organic frameworks using a tetraphenoxyborate linkage that maintains meticulous synergy between structural rigidity and local flexibility to achieve continuous and reversible (100 thermal cycles) tunability of “dynamic pores” between 2.9 and 4.0 angstroms, with resolution below 0.2 angstroms. This results from temperature-regulated, gradual amplitude change of high-frequency linker oscillations. These thermoelastic apertures selectively block larger molecules over marginally smaller ones, demonstrating size-based molecular recognition and the potential for separating challenging gas mixtures such as oxygen/nitrogen and nitrogen/methane.

crystalline materials↗

Coal-fueled Pressurized Chemical Looping Combustion with a Spouting Fluidized Bed

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0025098. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UKy-CAER) (Recipient) has developed a coal-based combined cycle integrated with a pressurized chemical looping combustion (PCLC) technology to achieve high plant efficiency while capturing CO 2 at low cost. The project involved the design, fabrication, commissioning, parametric testing, and performance validation of the spouted bed approach as coal feeding to narrow the major near-term technical gaps that impede the application of PCLC into solid fuel and scale-up. Specifically, UKy-CAER provided detailed front-end design of a 50 kWth PCLC facility, produced approximately 500 lbs of oxygen carrier (OC) from industrial by-product, Red Mud in addition to commercially available ilmenite, and completed a 70+ hour-long experimental campaign to evaluate the coal feed system and performance and flexibility of the 50 kWth facility with various coal, operating pressures, fluidization agent, and OCs. Project results verified UKy-CAER’s proposed approach to address the major technical gaps of solid-fueled PCLC technology which includes: (1) cost-effective materials for OCs with high reactivity, cyclic capacity, chemical stability, and high resistance to agglomeration with coal ash; (2) fast reaction rates during solid-solid chemical looping combustion (CLC) for reduction of the OC inventory and reactor size; (3) simple and effective ash separation from binary mixtures of the OCs and solid fuel ash; (4) spouting bed coal feeding to suppress OC agglomeration in the reducer resulting from the initial coal devolatilization step, coal tar formation; and (5) pollutant removal to avoid sulfur accumulation in the system or their emission into the hot spent air stream which could result in a second train for SOx removal and potentially cause failure of the flue gas turbine blade. UKy-CAER’s economical cycling material and novel spouted bed reducer configuration shows promise, as summarized in this report, as an effective means for improved plant efficiency with reduced process complexity.

01 COAL, LIGNITE, AND PEAT↗

New Molecular Mechanisms for Greenhouse Gas Capture in Metal-Organic Frameworks: Carbon Dioxide and Beyond

Separations involving gaseous small molecules, including acid gases, nitrous oxide, and hydrofluorocarbons, are vital to U.S. energy and technological dominance. However, many current separations technologies are too energy-intensive for broad deployment. Sorptive separations, in which a mixture of gases is contacted with a porous solid material, leading to separation based on the differing affinity of the gases for the solid, promise lower energy requirements compared to many existing technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An explosion-proof battery case

Battery case, equipped with relief valve, connector, and two covers, separates the explosive mixture from all potential spark sources. Bottom ends of vent tubes are cemented into cell vents and upper ends fit through the gas barrier cover. This arrangement isolates generated gases from the electric power.

Keathley, W. H.↗

Evaluation of a spacecraft nitrogen generator

A method is discussed of generating nitrogen for cabin leakage makeup aboard space vehicles having longer duration missions. The nitrogen generation concept is based on using liquid hydrazine as the stored form of nitrogen to reduce the higher tankage and expendables weight associated with high pressure gaseous or cryogenic liquid nitrogen storage. The hydrazine is catalytically dissociated to yield a mixture of nitrogen and hydrogen. The nitrogen/hydrogen mixture is then separated to yield the makeup nitrogen. The excess supply of hydrogen would be available for use in the reduction of metabolic carbon dioxide. A detailed comparison was completed of Palladium/Silver and Polymer Electrochemical-based Nitrogen Generation Systems. The palladium/silver-based system was judged better than the Polymer Electrochemical Nitrogen Generation System because of lower expendable weight and palladium/silver nitrogen/hydrogen separation represents 'off-the-shelf' technology.

Marshall, R. D.↗

Fluid mass sensor for a zero gravity environment

A sensor for measuring the mass of fluids, is described which includes a housing having an inlet and outlet for receiving and dumping the fluid, a rotary impeller within the housing for imparting centrifugal motion to the fluid and a pressure sensitive transducer attached to the housing to sense the rotating fluid pressure. The fluid may be drawn into the housing by entrainment within a gas stream. The resulting mixture is then separated into two phases: gas and liquid. The gas is removed from the housing and the pressure of the liquid, under centrifugal motion, is sensed and correlated with the mass of the fluid.

Fogal, G. L.↗

Study of the potential for improving the economics of hydrogen liquefaction through the use of centrifugal compressors and the addition of a heavy water plant

An approach to the liquefaction of hydrogen was developed which permits the application of standard centrifugal compressors in place of reciprocating machines. A second fluid, such as propane, is added to the hydrogen prior to compression to form a mixture having a molecular weight much greater than that of hydrogen alone, so that a standard centrifugal compressor can be used. After compression, the mixture is cooled to cryogenic temperature levels where the propane condenses out of the mixture and is separated as a liquid. Since a small amount of deuterium is produced during hydrogen liquefaction, the potential of recovering deuterium and selling it as a co-product was investigated. Deuterium, in the form of heavy water, can be used in certain nuclear reactors as a neutron moderator to reduce the neutron velocity and enhance the probability of neutron collision with uranium nucleii.

Baker, C. R.↗

Solar driven liquid metal MHD power generator

A solar energy collector focuses solar energy onto a solar oven which is attached to a mixer which in turn is attached to the channel of a MHD generator. Gas enters the oven and a liquid metal enters the mixer. The gas/liquid metal mixture is heated by the collected solar energy and moves through the MHD generator thereby generating electrical power. The mixture is then separated and recycled.

Lee, J. H.↗

Cloned Hemoglobin Genes Enhance Growth Of Cells

Experiments show that portable deoxyribonucleic acid (DNA) sequences incorporated into host cells make them produce hemoglobins - oxygen-binding proteins essential to function of red blood cells. Method useful in several biotechnological applications. One, enhancement of growth of cells at higher densities. Another, production of hemoglobin to enhance supplies of oxygen in cells, for use in chemical reactions requiring oxygen, as additive to serum to increase transport of oxygen, and for binding and separating oxygen from mixtures of gases.

Khosla, Chaitan↗

Oligomerizations of deoxyadenosine bis-phosphates and of their 3-prime-5-prime, 3-prime-3-prime, and 5-prime-5-prime dimers - Effects of a pyrophosphate-linked, poly(T) analog

The effect of a 3-prime-5-prime pyrophosphate-linked oligomer of pTp on oligomerizations of pdAp and of its 3-prime-5-prime, 3-prime-3-prime, and 5-prime-5-prime dimers was investigated, using HPLC to separate the reaction mixtures; peak detection was by absorbance monitoring at 254 nm. It was expected that the dimers would form stable complexes with the template, with the degree of stability depending upon the internal linkage of each dimer. It was found that, although the isomers differ substantially in their oligomerization behavior in the absence of template, the analog-template catalyzes the oligomerization to about the same extent in all three cases.

Visscher, J.↗

Laboratory investigations of the aerosols in the stratosphere of Titan

Results of experiments in which particles were produced from UV photolysis of C2H2, C2H4, or HCN, separately or in mixtures, modeling Titan's upper atmosphere, are presented. The particles were collected on disks and examined by Scanning Electron Microscopy (SEM). Measurements of particle sizes and shapes and of aggregation were determined from the SEM photographs.

Scattergood, Thomas W.↗

JPL research to develop a He-3/He-4 dilution refrigerator for space applications

A research program to develop a He-3/He-4 solution refrigerator for space applications is underway. The results of the effort to use an electric field as a substitute for gravity to control the He-3/He-4 mixture interface that separates phases in terrestrial units are described. Further, experimental results obtained from an engineering model of a single-cycle dilution refrigerator with a mixing chamber capable of operating in a zero-gravity environment are described. Future research and development plans are outlined, in particular the need to test the operation of a single-cycle as well as a continuously operating dilution refrigerator in space.

Petrac, D.↗

Definition of two-phase flow behaviors for spacecraft design

Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. A boiling and condensing experiment was built in which R-12 was used as the working fluid. A two-phase pump was used to circulate a freon mixture and allow separate measurements of the vapor and liquid flow streams. The experimental package was flown five times aboard the NASA KC-135 aircraft which simulates zero-g conditions by its parabolic flight trajectory. Test conditions included stratified and annual flow regimes in 1-g which became bubbly, slug, or annular flow regimes on 0-g. A portion of this work is the analysis of adiabatic flow regimes. The superficial velocities of liquid and vapor have been obtained from the measured flow rates and are presented along with the observed flow regimes.

Reinarts, Thomas R.↗

Compression-ignition engine performance with undoped and doped fuel oils and alcohol mixtures

Several fuel oils, doped fuel oils, and mixtures of alcohol and fuel oil were tested in a high-speed, single-cylinder, compression-ignition engine to determine power output, fuel consumption, and ignition and combustion characteristics. Fuel oils or doped fuel oils of high octane number had shorter ignition lags, lower rates of pressure rise, and gave smoother engine operation than fuel oils or doped fuel oils of low octane number. Higher engine rotative speeds and boost pressures resulted in smoother engine operation and permitted the use of fuel oils of relatively low octane number. Although the addition of a dope to a fuel oil decreased the ignition lag and the rate of pressure rise, the ensuing rate of combustion was somewhat slower than for the undoped fuel oil so that the effectiveness of combustion was practically unchanged. Alcohol used as an auxiliary fuel, either as a mixture or by separate injection, increased the rates of pressure rise and induced roughness. In general, the power output decreased as the proportion of alcohol increased and, below maximum power, varied with the heating value of the total fuel charge.

Moore, Charles S↗

Development of an advanced spacecraft tandem mass spectrometer

The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

Drew, Russell C.↗

Mars Solar Balloon Landed Gas Chromatograph Mass Spectrometer

A Mars surface lander Gas Chromatograph Mass Spectrometer (GCMS) is described to measure the chemical composition of abundant and trace volatile species and isotope ratios for noble gases and other elements. These measurements are relevant to the study of atmospheric evolution and past climatic conditions. A Micromission plan is under study where a surface package including a miniaturized GCMS would be delivered to the surface by a solar heated hot air balloon based system. The balloon system would be deployed about 8 km above the surface of Mars, wherein it would rapidly fill with Martian atmosphere and be heated quickly by the sun. The combined buoyancy and parachuting effects of the solar balloon result in a surface package impact of about 5 m/sec. After delivery of the package to the surface, the balloon would ascend to about 4 km altitude, with imaging and magnetometry data being taken for the remainder of the daylight hours as the balloon is blown with the Martian winds. Total atmospheric entry mass of this mission is estimated to be approximately 50 kg, and it can fit as an Ariane 5 piggyback payload. The GCMS would obtain samples directly from the atmosphere at the surface and also from gases evolved from solid phase material collected from well below the surface with a Sample Acquisition and Transport Mechanism (SATM). The experiment envisioned in the Mars Micromission described would obtain samples from a much greater depth of up to one meter below the surface, and would search for organic molecules trapped in ancient stratified layers well below the oxidized surface. Insitu instruments on upcoming NASA missions working in concert with remote sensing measurement techniques have the potential to provide a more detailed investigation of mineralogy and the extent of simple volatiles such as CO2 and H2O in surface and subsurface solid phase materials. Within the context of subsequent mission opportunities such as those provided by the Ariane 5 piggyback payload based Micromissions, it is essential to implement an even broader chemical analysis and to enable a significant extension of previous isotope measurements. Such a development would enhance the presently very active study of questions of atmospheric evolution and loss and past climatic conditions. The method selected to implement this program can be based on well-established mass spectrometry techniques. Sampled gas is chemically and physically processed to separate the gas mixture into components using gas chromatograph and related enrichment techniques. This allows trace species to be identified and reveals isotopic distributions in many cases with improved precision. Samples of interest, such as organic molecules, may lie deep below the highly oxidized surface layer and the suggested program includes enhanced sampling techniques to measure volatiles preserved in solid phase material deep below the surface as well as gas from the well mixed atmosphere.

Mahaffy, P.↗

Gas Analyzer

The M200 originated in the 1970's under an Ames Research Center/Stanford University contract to develop a small, lightweight gas analyzer for Viking Landers. Although the unit was not used on the spacecraft, it was further developed by The National Institute for Occupational Safety and Health (NIOSH). Three researchers from the project later formed Microsensor Technology, Inc. (MTI) to commercialize the analyzer. The original version (Micromonitor 500) was introduced in 1982, and the M200 in 1988. The M200, a more advanced version, features dual gas chromatograph which separate a gaseous mixture into components and measure concentrations of each gas. It is useful for monitoring gas leaks, chemical spills, etc. Many analyses are completed in less than 30 seconds, and a wide range of mixtures can be analyzed.

Source record↗

Portable Gas Analyzer

The Michromonitor M500 universal gas analyzer contains a series of miniature modules, each of which is a complete gas chromatograph, an instrument which separates a gaseous mixture into its components and measures the concentrations of each gas in the mixture. The system is manufactured by Microsensor Technology, and is used for environmental analysis, monitoring for gas leaks and chemical spills, compliance with pollution laws, etc. The technology is based on a Viking attempt to detect life on Mars. Ames/Stanford miniaturized the system and NIOSH funded further development. Three Stanford researchers commercialized the technology, which can be operated by unskilled personnel.

Source record↗