Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mobile Measuring System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Testing and Improving a UAV-Based System Designed for Wetland Methane Source Measurements

Wetlands are the single highest emitting methane source category, but the magnitude of wetland fluxes remains difficult to fully characterize due to their large spatial extent and heterogeneity. Fluxes can vary with land surface conditions, vegetation type, and seasonal changes in environmental conditions. Unmanned aerial vehicles (UAVs) are an emerging platform to better characterize spatial variability in these natural ecosystems. While presenting some advantages over traditional techniques like towers and flux chambers, in that they are mobile vertically and horizontally, their use is still challenging, requiring continued improvement in sensor technology and field measurement approaches. In this work, we employ a small, fast response laser spectrometer on a Matrice 600 hexacopter. The system was previously deployed successfully for 40 flights conducted in a four-day period in 2018 near Fairbanks, Alaska. These flights revealed several potential areas for improvement, including: vertical positioning accuracy, the need for sensor health indicators, and approaches to deal with low wind speeds. An additional set of flights was conducted this year near Antioch in California. Flights were conducted several meters above ground up to 15-25 m in a curtain pattern. These curtains were flown both upwind and downwind of a tower site, allowing us to calculate a mass balance methane flux estimate that can be compared to eddy covariance fluxes from the tower. Testing will better characterize the extent to which altitude drifts in-flight and how GPS values compare with measurements from the onboard LIDAR, as well as the agreement between two-dimensional wind speed and direction on the ground versus measured onboard the UAV. Hardware improvements to the sensor and GPS are being considered to help reduce these sources of uncertainty. Results of this testing and how system performance relates to needs for quantifying wetland fluxes, will be presented.

Golston, Levi↗

Cyclotron resonance in the high mobility GaAs/AlGaAs 2D electron system over the microwave, mm-wave, and terahertz- bands

Abstract The reflected microwave power from the photo-excited high mobility GaAs/AlGaAs 2D device has been measured over the wide frequency band spanning from 30 to 330 GHz simultaneously along with diagonal magnetoresistance as a function of the magnetic field. Easily distinguishable resonances in the reflected power signal are observed at the same magnetic fields as a reduced amplitude in the Shubnikov-de Haas (SdH) oscillations of the diagonal magnetoresistance. The reflection resonances with concurrent amplitude reduction in SdH oscillations are correlated with cyclotron resonance induced by microwave, mm-wave, and terahertz photoexcitation. The magnetoplasma effect was also investigated. The results suggest a finite frequency zero-magnetic-field intercept, providing an estimate for the plasma frequency. The experimentally measured plasma frequency appears to be somewhat lower than the estimated plasma frequency for these Hall bars. The results, in sum, are consistent with an effective mass ratio of m*/m = 0.067, the standard value, even in these high mobility GaAs/AlGaAs devices, at very large filling factors. Preliminary findings from this article have been published as conference proceedings, see Kriisa, A., et al ., J. of Phys. Conf. Ser . 864 , 012057 (2017).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oxygen tank assemblies

Structural design considerations for O2 tank shells and suspension systems of ground based storage and mobile tank systems are outlined. Safety factors, chemical compatibility, liquid slosh strength, and cryogenic temperature properties are summarized. Finally, costs, quality control measures, and long life characteristics are examined.

Source record↗

Countercurrent distribution of biological cells

Detailed physiochemical studies of dextran/poly(ethylene glycol) (PEG) two phase systems were carried out to characterize and provide understanding of the properties of the systems which determine cell partition and the electrophoretic behavior of phase drops responsible for electric field driven phase separation. A detailed study of the electrostatic and electrokinetic potentials developed in these systems was carried out. The salt partition was examined both in phase systems and with pure polymer solutions via equilibrium dialysis and mechanism of sulfate, chloride and phosphate partition shown to be exclusion by PEG rather than binding by dextran. Salt partition was shown to have a strong effect on the polymer compositions of the phases as well, an effect which produces large changes in the interfacial tension between them. These effects were characterized and the interfacial tension shown to obey a power law with respect to its dependence on the length of the tie line describing the system composition on a phase diagram. The electrostatic potential differences measured via salt bridges were shown to obey thermodynamic predictions. The electrophoretic mobilities measured were utilized to provide a partial test of Levine's incomplete theory of phase drop electrophoresis. The data were consistent with Levine's expression over a limited range of the variables tested.

Brooks, D. E.↗

The 32-GHz performance of the DSS-14 70-meter antenna: 1989 configuration

The results of preliminary 32 GHz calibrations of the 70 meter antenna at Goldstone are presented. Measurements were done between March and July 1989 using Virgo A and Venus as the primary efficiency calibrators. The flux densites of theses radio sources at 32 GHz are not known with high accuracy, but were extrapolated from calibrated data at lower frequencies. The measured value of efficiency (0.35) agreed closely with the predicted value (0.32), and the results are very repeatable. Flux densities of secondary sources used in the observations were subsequently derived. These measurements were performed using a beamswitching radiometer that employed an uncooled high-electron mobility transistor (HEMT) low-noise amplifier. This system was installed primarily to determine the performance of the antenna in its 1989 configuration, but the experience will also aid in successful future calibration of the Deep Space Network (DSN) at this frequency.

Gatti, M. S.↗

Verification of Ares I Liftoff Acoustic Environments via the Ares I Scale Model Acoustic Test

The Ares I Scale Model Acoustic Test (ASMAT) program was implemented to verify the predicted Ares I liftoff acoustic environments and to determine the acoustic reduction gained by using an above deck water sound suppression system. The test article included a 5% scale Ares I vehicle model and Mobile Launcher with tower. Acoustic and pressure data were measured by over 200 instruments. The ASMAT results are compared to Ares I-X flight data.

Counter, Douglas↗

The ISRU Field Tests 2010 and 2012 at Mauna Kea, Hawaii: Results from the Miniaturised Mossbauer Spectrometers Mimos II and Mimos IIA

The 2010 and 2012 In-Situ Resource Utilization Analogue Test (ISRU) [1] on the Mauna Kea volcano in Hawai'i was coordinated by the Northern Centre for Advanced Technology (NORCAT) in collaboration with the Canadian Space Agency (CSA), the German Aerospace Center (DLR), and the National Aeronautics and Space Administration (NASA), through the PISCES program. Several instruments were tested as reference candidates for future analogue testing at the new field test site at the Mauna Kea volcano in Hawai'i. The fine-grained, volcanic nature of the material is a suitable lunar and martian analogue, and can be used to test excavation, site preparation, and resource utilization techniques. The 2010 location Pu'u Hiwahine, a cinder cone located below the summit of Mauna Kea (19deg45'39.29" N, 155deg28'14.56" W) at an elevation of ~2800 m, provides a large number of slopes, rock avalanches, etc. to perform mobility tests, site preparation or resource prospecting. Besides hardware testing of technologies and systems related to resource identification, also in situ science measurements played a significant role in integration of ISRU and science instruments. For the advanced Mössbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform Xray fluorescence analysis simultaneously to Mössbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The 2010 and 2012 field campaigns demonstrated that in-situ Mössbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.

Klingelhoefer, G.↗

WRAP-RIB antenna technology development

The wrap-rib deployable antenna concept development is based on a combination of hardware development and testing along with extensive supporting analysis. The proof-of-concept hardware models are large in size so they will address the same basic problems associated with the design fabrication, assembly and test as the full-scale systems which were selected to be 100 meters at the beginning of the program. The hardware evaluation program consists of functional performance tests, design verification tests and analytical model verification tests. Functional testing consists of kinematic deployment, mesh management and verification of mechanical packaging efficiencies. Design verification consists of rib contour precision measurement, rib cross-section variation evaluation, rib materials characterizations and manufacturing imperfections assessment. Analytical model verification and refinement include mesh stiffness measurement, rib static and dynamic testing, mass measurement, and rib cross-section characterization. This concept was considered for a number of potential applications that include mobile communications, VLBI, and aircraft surveillance. In fact, baseline system configurations were developed by JPL, using the appropriate wrap-rib antenna, for all three classes of applications.

Freeland, R. E.↗

Detection of THz radiation with devices made from wafers with HgTe and InSb quantum wells

In this study we present measurements of the Terahertz (THz) photoconductivity of 2D electron system realized at HgTe/HgCdTe and AlInSb/InSb/AlInSb quantum wells (QWs) in Corbino geometry (inner and outer radius: 500 {mu}m and 1500 {mu}m) with different mobilities and electron densities. To characterize the devices, the Shubnikov-de Haas (SdH) effect up to magnetic fields B of 7T and current-voltage (I-V) characteristics at various magnetic fields were measured. The THz radiation is provided by a p-Ge laser which operates with a magnetic field and a high voltage for the electrical pumping. The stimulated emission is caused by transitions between Landau levels of light holes [1]. The laser is tunable in the range between 1.7 to 2.5 THz (corresponding to wavelengths between 120 to 180 {mu}m or energies of 7 to 12 meV). The laser is pulsed with a pulse rate of 1 Hz and pulse lengths of about 1 {mu}s with low switching times (about 20 ns). The monochromatic THz radiation is transferred to our samples via a 0.32m long brass waveguide immersed in liquid Helium. The detection of a change in the conductivity of the sample due to absorption of THz-radiation (photoresponse) requires a low-noise circuit. For the Corbino-shaped samples the photoresponse (PR) is measured via a resistor R{sub V} of 1 k{Omega}. The signal is transferred via in a high-frequency cable and detected with a digital oscilloscope.

36 MATERIALS SCIENCE↗

Explanation and Application of the Evolving Contact Traction Fields in Shallow Foundation Systems

The present paper provides a qualitative discussion of the evolution of contact traction fields beneath rigid shallow foundations resting on granular materials. A phenomenological similarity is recognized in the measured contact traction fields of rigid footings and at the bases of sandpiles. This observation leads to the hypothesis that the stress distributions are brought about by the same physical phenomena, namely the development of arching effects through force chains and mobilized intergranular friction. A set of semi-empirical equations are suggested for the normal and tangential components of this contact traction based on past experimental measurements and phenomenological assumptions of frictional behaviors at the foundation system scale. These equations are then applied to the prescribed boundary conditions for the analysis of the settlement, resistance, and stress fields in supporting granular materials beneath the footing. A parametric sensitivity study is performed on the proposed modelling method, highlighting solutions to the boundary-value problems in an isotropic, homogeneous elastic half-space.

42 ENGINEERING↗

ATS-6 engineering performance report. Volume 5: Propagation experiments

Propagation experiments at 1550 MHz to 1650 MHz are reviewed, including the Integrated L-Band Experiments system and results, and the Mobile L-Band Terminals for Satellite Communication system. Experiments at 4 GHz to 6 GHz are reported, including the Radio Frequency Interferometer Measurements system and results, and Earth station antenna evaluations. Experiments above 10 GHz are discussed, including Comsat and ATS-6 millimeter wave propagation/experiments, and communication ATS-6 version at 20 and 30 GHz.

Wales, R. O.↗

Enhancing the Electron Mobility via Delta-Doping in SrTiO3

We fabricated high-mobility {delta}-doped structures in SrTiO{sub 3} thin films in order to investigate the low temperature electronic transport properties of confined carriers in this system. An enhancement of the electron mobility above the bulk value was observed as the doped layer thickness decreased. High-field Hall measurements revealed that this mobility enhancement originates from higher-mobility electrons in the undoped clean regions, which have quantum-mechanically broadened from the doped layer. Because of the absence of apparent lattice misfit between the layers, this structure is highly suitable for investigating two-dimensional electron gases in SrTiO{sub 3}

36 MATERIALS SCIENCE↗

Results of Outdoor to Indoor Propagation Measurements from 5-32GHz

The demand for wireless services has increased exponentially in the last few years and shows no signs of slowing in the near future. In order for the next generation wireless to provide seamless access, whether the user is indoors or out, a thorough understanding and validation of models describing the impact of building entry loss (BEL) is required. This information is currently lacking and presents a challenge for most system designers. For this reason empirical data is needed to assess the impact of BEL at frequencies that are being explored for future mobile broadband applications This paper present the results of measurements of outdoor-to-indoor propagation from 5-32 GHz in three different buildings. The first is a newer building that is similar in construction to modern residential home. The second is an older commercial office building. The last building is a very new commercial office building built using modern green building techniques. These three buildings allow for the measurement of propagation losses through both modern and older materials; such as glass windows and exterior block and siding. Initial results found that at particular spatial locations the BEL could be less than 1dB or more than 70dB with free space losses discounted (this is likely influenced by multipath). Additionally, it was observed that the PDF distributions of a majority of the measurements trended toward log-normal with means and standard deviations ranging from 8-38dB and 6-14dB, respectively.

building entry loss↗

SU-E-I-21: Dosimetric Characterization and Image Quality Evaluation of the AIRO Mobile CT Scanner

Purpose: The AIRO Mobile CT system was recently introduced which overcomes the limitations from existing CT, CT fluoroscopy, and intraoperative O-arm. With an integrated table and a large diameter bore, the system is suitable for cranial, spine and trauma procedures, making it a highly versatile intraoperative imaging system. This study is to investigate radiation dose and image quality of the AIRO and compared with those from a routine CT scanner. Methods: Radiation dose was measured using a conventional 100mm pencil ionization chamber and CT polymethylmetacrylate (PMMA) body and head phantoms. Image quality was evaluated with a CATPHAN 500 phantom. Spatial resolution, low contrast resolution (CNR), Modulation Transfer Function (MTF), and Normalized Noise Power Spectrum (NNPS) were analyzed. Results: Under identical technique conditions, radiation dose (mGy/mAs) from the AIRO mobile CT system (AIRO) is higher than that from a 64 slice CT scanner. MTFs show that both Soft and Standard filters of the AIRO system lost resolution quickly compared to the Sensation 64 slice CT. With the Standard kernel, the spatial resolutions of the AIRO system are 3lp/cm and 4lp/cm for the body and head FOVs, respectively. NNPSs show low frequency noise due to ring-like artifacts. Due to a higher dose in terms of mGy/mAs at both head and body FOV, CNR of the AIRO system is higher than that of the Siemens scanner. However detectability of the low contrast objects is poorer in the AIRO due to the presence of ring artifacts in the location of the targets. Conclusion: For image guided surgery applications, the AIRO has some advantages over a routine CT scanner due to its versatility, large bore size, and acceptable image quality. Our evaluation of the physical performance helps its future improvements.

60 APPLIED LIFE SCIENCES↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Severe storm electricity

Severe storms and lightning were measured with a NASA U2 and ground based facilities, both fixed base and mobile. Aspects of this program are reported. The following results are presented: (1) ground truth measurements of lightning for comparison with those obtained by the U2. These measurements include flash type identification, electric field changes, optical waveforms, and ground strike location; (2) simultaneous extremely low frequency (ELF) waveforms for cloud to ground (CG) flashes; (3) the CG strike location system (LLP) using a combination of mobile laboratory and television video data are assessed; (4) continued development of analog-to-digital conversion techniques for processing lightning data from the U2, mobile laboratory, and NSSL sensors; (5) completion of an all azimuth TV system for CG ground truth; (6) a preliminary analysis of both IC and CG lightning in a mesocyclone; and (7) the finding of a bimodal peak in altitude lightning activity in some storms in the Great Plains and on the east coast. In the forms on the Great Plains, there was a distinct class of flash what forms the upper mode of the distribution. These flashes are smaller horizontal extent, but occur more frequently than flashes in the lower mode of the distribution.

Rust, W. D.↗

Satellite Ka-band propagation measurements in Florida

Commercial growth of interactive, high data rate communication systems is expected to focus on the use of the Ka-band (20/30 GHz) radio spectrum. The ability to form narrow spot beams and the attendant small diameter antennas are attractive features to designers of mobile aeronautical and ground based satellite communication systems. However, Ka-band is strongly affected by weather, particularly rain, and hence systems designs may require a significant link margin for reliable operations. Perhaps the most stressing area in North America, weatherwise, is the Florida sub-tropical climatic region. As part of the NASA Advanced Communications Technology Satellite (ACTS) propagation measurements program, beacon and radiometer data have been recorded since December 1993 at the University of South Florida (USF), Tampa, Florida.

Helmken, Henry↗

Diamond micro-Raman thermometers for accurate gate temperature measurements

Determining the peak channel temperature in AlGaN/GaN high electron mobility transistors and other devices with high accuracy is an important and challenging issue. A surface-sensitive thermometric technique is demonstrated, utilizing Raman thermography and diamond microparticles to measure the gate temperature. This technique enhances peak channel temperature estimation, especially when it is applied in combination with standard micro-Raman thermography. Its application to other metal-covered areas of devices, such as field plates is demonstrated. Furthermore, this technique can be readily applied to other material/device systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗