Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muscle Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Development and chromosome mechanics in nematodes: Results from IML-1

A subset of the Caenorhabditis elegans nematodes flown aboard Biorack on IML-1 was analyzed for the fidelity of development and the mechanics of chromosomes at meiosis. To assess meiosis, mutant worms marked at two linked or unlinked loci were inoculated as heterozygous hermaphrodites and allowed to self fertilize. Mendelian segregation ratios and recombination frequency were measured for offspring produced at 1XG or in microgravity. To assess development, worms and embryos were fixed and stained with the DNA dye, Diamidinophenolindole (DAPI), or antibodies specific for antigens expressed in germ cells, pharyngeal and body wall muscles, and gut cells. The distribution of cytoplasmic determinants, cell nuclei counts and positions were scored to assess symmetry relations and anatomical features.

Nelson, G. A.↗

Gel stretch method: a new method to measure constitutive properties of cardiac muscle cells

Diastolic dysfunction is an important cause of congestive heart failure; however, the basic mechanisms causing diastolic congestive heart failure are not fully understood, especially the role of the cardiac muscle cell, or cardiocyte, in this process. Before the role of the cardiocyte in this pathophysiology can be defined, methods for measuring cardiocyte constitutive properties must be developed and validated. Thus this study was designed to evaluate a new method to characterize cardiocyte constitutive properties, the gel stretch method. Cardiocytes were isolated enzymatically from normal feline hearts and embedded in a 2% agarose gel containing HEPES-Krebs buffer and laminin. This gel was cast in a shape that allowed it to be placed in a stretching device. The ends of the gel were held between a movable roller and fixed plates that acted as mandibles. Distance between the right and left mandibles was increased using a stepper motor system. The force applied to the gel was measured by a force transducer. The resultant cardiocyte strain was determined by imaging the cells with a microscope, capturing the images with a CCD camera, and measuring cardiocyte and sarcomere length changes. Cardiocyte stress was characterized with a finite-element method. These measurements of cardiocyte stress and strain were used to determine cardiocyte stiffness. Two variables affecting cardiocyte stiffness were measured, the passive elastic spring and viscous damping. The passive spring was assessed by increasing the force on the gel at 1 g/min, modeling the resultant stress vs. strain relationship as an exponential [sigma = A/k(ekepsilon - 1)]. In normal cardiocytes, A = 23.0 kN/m2 and k = 16. Viscous damping was assessed by examining the loop area between the stress vs. strain relationship during 1 g/min increases and decreases in force. Normal cardiocytes had a finite loop area = 1.39 kN/m2, indicating the presence of viscous damping. Thus the gel stretch method provided accurate measurements of cardiocyte constitutive properties. These measurements have allowed the first quantitative assessment of passive elastic spring properties and viscous damping in normal mammalian cardiocytes.

Non-NASA Center↗

Bion-M2

Bion-M2, scheduled to launch in April 2023, continues the 30+ year collaboration between the Institute of Biomedical Problems of the Russian Academy of Sciences (IBMP RAS) and the National Aeronautics and Space Administration (NASA). Bion-M2 is the second biosatellite in the Bion-M series and its goal is to investigate how the space environment affects living organisms, with emphasis on physiological changes in rodents, gravitational biology using a wide variety of specimens, and radiation biology. The Bion-M2 biosatellite will complete a 30-day low earth orbit (LEO) flight to study the combined effects of microgravity and ionizing radiation (IR) on multiple organisms, where the payload may be exposed to IR at 20-30 times thedose rate seen on the International Space Station. Following return, nine U.S. collaborators selected through the NASA Space Biology Research Announcement will conduct post-flight rodent experiments using male C57BL/6 mice. The post-flight experiments will investigate the effects of the space environment on bone and skeletal muscle health, cardiac function, reproductive system function, neurovascular systems, protein composition in plasma, and thermoregulation in the mice. Currently, the Bion-M2 mission is in the development phase of theproject lifecycle. The mission objectives, constraints, requirements, and timeline have been defined in the project plan and contracts. Technology for the mission is under development and science procedures will be finalized by FY22. The aim of this presentation is to highlight the importance of the Bion-M2 mission and provide insight into the mission development process, including an overview of the project plan and the tissue sharing plan that will be utilized during the post-flight dissection procedures.

Bion-M2↗

Exploration Exercise System (EES) Physiology

Exploration class missions will be required to have an exercise device that is lightweight, has a small footprint, and is capable of providing enough physical stimulus and exercise variability to be an effective countermeasure against muscle, bone, aerobic fitness, and sensorimotor loss that results from the microgravity environment. Ground studies, inflight studies, and results analyses are required to inform Moon2Mars Design Reference Missions (DRMs) and vehicle designs. This activity encompasses two related projects, an evaluation study called Zero T2 and a requirements development for an exploration treadmill (ET). Exploration class missions’ mass/power/volume restrictions have resulted in the development of exercise devices that are motorized and flywheel-based to provide both aerobic and resistive training on one platform. These devices provide a variety of full body resistance exercise options as well as rowing and cycling for aerobic exercise, but do not provide ambulatory exercise via a treadmill. Because a treadmill has been available for use on the ISS since 2001, we do not understand the efficacy of exploration exercise modalities on muscle performance, aerobic fitness, bone health, or sensorimotor performance. A retrospective study was performed to quantify the association between total exercise (including specific contributions of treadmill exercise) and functional performance upon landing. Due to the relatively small variation in treadmill usage inflight, there is a need to do a controlled study where inflight crewmembers will not use the ISS treadmill (called T2) for the duration of their flights. There will be 3 arms to the Zero T2 study: 1) participants use all currently available exercise platforms aboard ISS (control group), 2) participants use only ARED and CEVIS, and 3) participants use only European Enhanced Exploration Device (E4D). (Please see the TechPort Entry for Exploration Exercise System Development for further detail on the E4D.) This study started in Oct 2020 and will continue through Sep 2027. In a parallel effort, a team will be developing requirements for an exploration treadmill. This project will be broken into two phases. Phase 1 will develop and implement energy prediction models based on available in-flight exercise data to quantify energy expenditure during 0g treadmill running. Phase 2 will then use the available biomechanical and metabolic evidence from Phase 1 to determine the hardware specification requirements essential to providing the desired exercise stimulus. Subject Matter Experts (SMEs) will then leverage the Standardized Process for Evaluating Exercise Devices (SPEED) developed by the team to 1) assess available technologies for candidate treadmills which meet defined requirements, 2) perform hands-on evaluations of top candidates, 3) provide evaluation outcomes and recommendations to developers. This project will begin in 2025 and continue through Sep 2030.

Kent Lawrence Kalogera↗

Five myofibrillar lesion types in eccentrically challenged, unloaded rat adductor longus muscle--a test model

Sarcomere disruptions are observed in the adductor longus (AL) muscles following voluntary reloading of spaceflown and hindlimb suspension unloaded (HSU) rat, which resemble lesions in eccentrically challenged muscle. We devised and tested an eccentric contraction (ECCON) test system for the 14-day HSU rat AL. Six to 7 hours following ECCON, ALs were fixed to allow immunostaining and electron microscopy (EM). Toluidine blue-stained histology semithin sections were screened for lesion density (#/mm2). Serial semithin sections from the ECCON group were characterized for myosin immunointensity of lesions. Five myofibrillar lesion types were identified in histological semithin sections: focal contractions; wide A-bands; opaque areas; missing A-bands; and hyperstretched sarcomeres. Lesion density by type was greater for ECCON than NonECCON ALs (P< or =0.05; focal contractions and opaque regions). Lesion density (#-of-all-five-types/mm2) was significantly different (ECCON: 23.91+/-10.58 vs. NonECCON: 5.48+/-1.28, P< or =0.05; ECCON vs. SHAM: 0.00+/-0.00; P< or = 0.025). PostECCON optimal tension decreased (Poi-drop, 17.84+/-4.22%) and was correlated to lesion density (R2=0.596), but prestretch tension demonstrated the highest correlation with lesion density (R2=0.994). In lesions, the darkly staining A-band lost the normally organized thick filament alignment to differing degrees across the different lesion types. Ranking the five lesion types by a measure of lesion length deformation (hypercontracted to hyperstretched) at the light microscopy level, related to the severity of thick filament registry loss across the lesion types at the electron microscopic level. This ranking suggested that the five lesion types seen in semithin sections at the light level represented a lesion progression sequence and paralleled myosin immunostaining loss as the distorted A-band filaments spread across the hyperlengthening lesion types. Lesion ultrastructure indicated damage involved calcium homeostasis loss (focal contraction lesions) and "thick-filament-centering" failure of titin (wide A-band lesions) in the early stages of lesion development.

NASA Discipline Musculoskeletal↗

Biomechanical Modeling of Split-leg Squat and Heel Raise on the Hybrid Ultimate Lifting Kit (HULK)

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and musculoskeletal forces that occur during exercises performed on the prototype devices. Computational models currently use OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from subjects for estimation of muscle and joint loads. Subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the loads on the body. Multiple exercises are performed and evaluated during a test session such as a full squat, single leg squat, heel raise and dead lift. Variables for these exercises include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data from free weights are compared to the resistively loaded exercise device. The focus of this presentation is to summarize the results from the single-leg squat and heel raise exercises performed during three sessions occurring in 2015. Differences in loading configuration, cadence and stance produce differences in kinematics, joint toques and force and muscle forces.

computational modeling↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗

Correlation of macro and micro cardiovascular function during weightlessness and simulated weightlessness

The investigation of cardiovascular function necessarily involves a consideration of the exchange of substances at the capillary. If cardiovascular function is compromised or in any way altered during exposure to zero gravity in space, then it stands to reason that microvascular function is also modified. We have shown that an increase in cardiac output similar to that reported during simulated weightlessness is associated with a doubling of the number of post-capillary venules and a reduction in the number of arterioles by 35%. If the weightlessness of space travel produces similar changes in cardiopulmonary volume and cardiac output, a reasonable expectation is that astronauts will undergo venous neovascularization. We have developed an animal model in which to correlate microvascular and systemic cardiovascular function. The microcirculatory preparation consists of a lightweight, thermo-neutral chamber implanted around intact skeletal muscle on the back of a rat. Using this technique, the performed microvasculature of the cutaneous maximus muscle may be observed in the conscious, unanesthetized animal. Microcirculatory variables which may be obtained include venular and arteriolar numbers, lengths and diameters, single vessel flow velocities, vasomotion, capillary hematocrit anastomoses and orders of branching. Systemic hemodynamic monitoring of cardiac output by electromagnetic flowmetry, and arterial and venous pressures allows correlation of macro- and microcirculatory changes at the same time, in the same animal. Observed and calculated hemodynamic variables also include pulse pressure, heart rate, stroke volume, total peripheral resistance, aortic compliance, minute work, peak aortic flow velocity and systolic time interval. In this manner, an integrated assessment of total cardiovascular function may be obtained in the same animal without the complicating influence of anesthetics.

NASA Discipline Number 00-00↗

A new animal model for modulating myosin isoform expression by altered mechanical activity

The purpose of this study was to develop a new rodent model that is capable of delineating the importance of mechanical loading on myosin heavy chain (MHC) isoform expression of the plantar and dorsi flexor muscles of the ankle. The essential components of this system include 1) stimulating electrodes that are chronically implanted into a muscle, allowing for the control of the activation pattern of the target muscle(s); 2) a training apparatus that translates the moment of the ankle into a linear force; and 3) a computer-controlled Cambridge 310 ergometer. The isovelocity profile of the ergometer ensured that the medial gastrocnemius (MG) produced forces that were > 90% of maximal isometric force (Po), and the eccentric contractions of the tibialis anterior (TA) were typically 120% of Po. Both the concentric and eccentric training programs produced statistically significant increases in the muscle mass of the MG (approximately 15%) and TA (approximately 7%) as well as a decrease in myofibrillar adenosinetriphosphatase activity. Both the white and red regions of the MG and TA exhibited significant increases in the relative content of the type IIa MHC and concomitant decreases in type IIb MHC expression. Although the red regions of the MG and red TA contained approximately 10% type I MHC, the training programs did not affect this isoform. It appears that when a fast-twitch muscle is stimulated at a high frequency (100 Hz) and required to contract either concentrically or eccentrically under high loading conditions, the expression of the type IIa MHC isoform will be upregulated, whereas that of the type IIb MHC will be concomitantly downregulated.

NASA Discipline Musculoskeletal↗

Microwave Treatment of Prostate Cancer and Hyperplasia

Microwave ablation in the form of microwave energy applied to a heart muscle by a coaxial catheter inserted in a vein in the groin area can be used to heat and kill diseased heart cells. A microwave catheter has been developed to provide deep myocardial ablation to treat ventricular tachycardia by restoring appropriate electrical activity within the heart and eliminating irregular heartbeats. The resulting microwave catheter design, which is now being developed for commercial use in treating ventricular tachycardia, can be modified to treat prostate cancer and benign prostatic hyperplasia (BPH). Inasmuch as the occurrence of BPH is increasing currently 350,000 operations per year are performed in the United States alone to treat this condition this microwave catheter has significant commercial potential.

Arndt, G. Dickey↗

Development of life sciences equipment for microgravity and hypergravity simulation

The mission of the Life Science Division at the NASA Ames Research Center is to investigate the effects of gravity on living systems in the spectrum from cells to humans. The range of these investigations is from microgravity, as experienced in space, to Earth's gravity, and hypergravity. Exposure to microgravity causes many physiological changes in humans and other mammals including a headward shift of body fluids, atrophy of muscles - especially the large muscles of the legs - and changes in bone and mineral metabolism. The high cost and limited opportunity for research experiments in space create a need to perform ground based simulation experiments on Earth. Models that simulate microgravity are used to help identify and quantify these changes, to investigate the mechanisms causing these changes and, in some cases, to develop countermeasures.

Mulenburg, G. M.↗

Industrial and biomedical use of aerospace personal cooling garments

Liquid-cooled garments (LCG) have been developed which utilize liquid-cooled modules rather than the network of tygon tubing typical of Apollo LCG's. The ultra-thin, heat-sealed, polyurethane modules are situated over the body to cover 50 percent of the body surface area with special emphasis on the 'working' muscles and the head-neck area. These garments are being designed specifically for industrial and biomedical uses, such as: a head-neck cooling system which is being tested for race-car drivers, tractor drivers, truck drivers, or a head-neck cooling system tested for the reduction of the scalp hair loss which normally accompanies cancer treatments. A combined head-neck and thorax unit is being developed for use during mine distaster rescue operations, and for other hazardous hot applications. Finally applications for head-neck and partitional cooling are anticipated for military pilots, tank drivers, and heavy equipment operations.

Williams, B. A.↗

Methodologies to determine forces on bones and muscles of body segments during exercise, employing compact sensors suitable for use in crowded space vehicles

A complete description of an instrumented ergometer system, including the sensors, the data acquisition system, and the methodologies to calculate the kinematic parameters were initially developed at Tulane University. This work was continued by the PI at NASA Johnson Space Center, where a flight ergometer was instrumented and tested during a KC-135 Zero-Gravity flight. The sensors that form part of the system include EMG probes and accelerometers mounted on the subject using the ergometer, load cells to measure pedal forces, and encoders to measure position and orientation of the pedal (foot). Currently, data from the flight test is being analyzed and processed to calculate the kinematic parameters of the individual. The formulation developed during the initial months of the grant will be used for this purpose. The system's components are compact (all sensors are very small). A salient feature of the system and associated methodology to determine the kinematics is that although it uses accelerometers, position is not determined by integration. Position is determined by determining the angle of two frames of reference for which acceleration at one point is known in coordinates of both frames.

Figueroa, Fernando↗

An Earthling to an Astronaut: Medical Challenges

Humans can travel safely into space in low Earth orbit (LEO) or to near-Earth objects if several medical, physiological, environmental, and human factors issues risks are mitigated. Research must be performed in order to set standards in these four areas, and current NASA standards are contained in the Space Flight Human System Standards volumes 1 and 2, and crew medical certification standards. These three sets of standards drive all of the clinical, biomedical research and environmental technology development for the NASA human space flight program. These standards also drive the identification of specific risks to crew health and safety, and we currently manage 65 human system risks within the human space flight program. Each risk has a specific program of research, technology development, and development of operational procedures to mitigate the risks. Some of the more important risks tat will be discussed in this talk include exposure to radiation, behavioral health due to confinement in a closed cabin, physiological changes such as loss of bone, muscle and exercise capability, reduction in immune system capability, environmental threats of maintaining an adequate atmosphere and water for drinking, avoidance of toxic or infectious material, protection of hearing, and human factors issues of equipment and task design. A nutritious and varied food supply must also be provided. All of these risks will be discussed and current strategies for mitigating these risks for long-duration human space flight. In mitigating these 65 human system risks, novel approaches to problem solving must be employed to find the most appropriate research and technology based applications. Some risk mitigations are developed internally to NASA while others are found through research grants, technology procurements, and more recently open innovation techniques to seek solutions from the global technical community. Examples and results will be presented from all of these approaches including the more recent use of prizes to stimulate innovation.

Davis, Jeffrey R.↗

Electroactive Polymer (EAP) Actuators for Future Humanlike Robots

Human-like robots are increasingly becoming an engineering reality thanks to recent technology advances. These robots, which are inspired greatly by science fiction, were originated from the desire to reproduce the human appearance, functions and intelligence and they may become our household appliance or even companion. The development of such robots is greatly supported by emerging biologically inspired technologies. Potentially, electroactive polymer (EAP) materials are offering actuation capabilities that allow emulating the action of our natural muscles for making such machines perform lifelike. There are many technical issues related to making such robots including the need for EAP materials that can operate as effective actuators. Beside the technology challenges these robots also raise concerns that need to be addressed prior to forming super capable robots. These include the need to prevent accidents, deliberate harm, or their use in crimes. In this paper, the potential EAP actuators and the challenges that these robots may pose will be reviewed.

biomimetics↗

Changes in diaphragm muscle collagen gene expression after acute unilateral denervation

The purpose of the present study was to examine the effects of acute (3 days) unilateral diaphragm denervation (DNV) on 1) levels of alpha 1(I) and alpha 1(III) procollagen mRNA; 2) collagen concentration [hydroxyproline (HYP)]; 3) amount of the nonreducible collagen cross-link hydroxylysylpyridinoline (HP); and 4) the passive force-length relationship of the muscle. The levels of alpha 1(I) and alpha 1(III) procollagen mRNA, HYP concentration, and amount of HP were measured in muscle segments from the midcostal region of DNV and intact (INT) hemidiaphragms of adult male Fischer 344 rats (250-300 g). The in vitro passive force-length relationship of DNV and INT hemidiaphragm was determined by lengthening and shortening the diaphragm muscle segments from 85 to 115% of optimal length at a constant velocity (0.6 optimal length/s). Three days after DNV, the level of alpha 1(I) procollagen mRNA was increased over 15-fold in the DNV hemidiaphragm compared with INT (P < 0.05), whereas the level of alpha 1(III) procollagen mRNA was increased by approximately sixfold in the DNV hemidiaphragm compared with INT (P < 0.05). Collagen (HYP) concentration did not differ between groups, averaging 8.7 and 8.9 micrograms/mg dry wt for the DNV and INT hemidiaphragms, respectively. In addition, there was no difference in the amount of the mature nonreducible collagen cross-link HP between the DNV and INT hemidiaphragms (0.66 vs. 0.76 mole HP/mole collagen, respectively). The amount of passive force developed during lengthening did not differ between DNV and INT hemidiaphragms. These data indicate that acute DNV of the hemidiaphragm is associated with an increase in the mRNA level of the two principal fibrillar collagen phenotypes in skeletal muscle. However, despite extensive muscle remodeling, the passive force-length relationship of the DNV hemidiaphragm is unaffected compared with the INT muscle.

Non-NASA Center↗

Effects of Spaceflight and Hindlimb Suspension on the Posture and Gait of Rats

Instability of posture and gait in astronauts following spaceflight (SF) is thought to result from muscle atrophy and from changes in sensory-motor integration in the CNS (central nervous system) that occur during adaptation to microgravity (micro-G). Individuals are thought to have developed, during SF, adaptive changes for the processing of proprioceptive, vestibular and visual sensory inputs with reduced weighting of gravity-based signals and increased weighting of visual and tactile cues. This sensory-motor rearrangement in the CNS apparently occurs to optimize neuromuscular system function for effective movement and postural control in micro-G. However, these adaptive changes are inappropriate for the 1 g environment and lead to disruptions in posture and gait on return to Earth. Few reports are available on the effects of SF on the motor behavior of animals. Rats studied following 18.5 - 19.5 days of SF in the COSMOS program were described as being ..'inert, apathetic, slow'.. and generally unstable. The hindlimbs of these rats were ..'thrust out from the body with fingers pulled apart and the shin unnaturally pronated'. On the 6th postflight day motor behavior was described as similar to that observed in preflight observations. Improved understanding of the mechanisms leading to these changes can be obtained in animal models through detailed analysis of neural and molecular mechanisms related to gait. To begin this process the posture and gait of rats were examined following exposure to either SF or hindlimb suspension (HLS), and during recovery from these conditions.

Fox, R. A.↗