Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

ICONS: Solid-State Composite Neutron Detector

Neutron detection is essential for identifying and monitoring nuclear materials and nuclear reactions. Most deployed neutron-detection systems rely on helium-3 ( 3 He) gas-filled tubes, which have been the standard technology for decades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron energy spectrum from 120 GeV protons on a thick copper target

Neutron energy spectrum from 120 GeV protons on a thick copper target was measured at the Meson Test Beam Facility (MTBF) at Fermi National Accelerator Laboratory. The data allows for evaluation of neutron production process implemented in theoretical simulation codes. It also helps exploring the reasons for some disagreement between calculation results and shielding benchmark data taken at high energy accelerator facilities, since it is evaluated separately from neutron transport. The experiment was carried out using a 120 GeV proton beam of 3E5 protons/spill. Since the spill duration was 4 seconds, protoninduced events were counted pulse by pulse. The intensity was maintained using diffusers and collimators installed in the beam line to MTBF. The protons hit a copper block target the size of which is 5cm x 5cm x 60 cm long. The neutrons produced in the target were measured using NE213 liquid scintillator detectors, placed about 5.5 m away from the target at 30{sup o} and 5 m 90{sup o} with respect to the proton beam axis. The neutron energy was determined by time-of-flight technique using timing difference between the NE213 and a plastic scintillator located just before the target. Neutron detection efficiency of NE213 was determined on basis of experimental data from the high energy neutron beam line at Los Alamos National Laboratory. The neutron spectrum was compared with the results of multiparticle transport codes to validate the implemented theoretical models. The apparatus would be applied to future measurements to obtain a systematic data set for secondary particle production on various target materials.

43 PARTICLE ACCELERATORS↗

High resolution measurement of tagged two-neutron energy and angle correlations in 252-Cf (sf)

Spontaneous fission events emit prompt neutrons correlated with one another in emission angle and energy. Measurements of these correlations can shed light on the partitioning of the excitation energy between the fragments, even if they are not directly measured. Purpose: We explore the relationship in energy and angle between correlated prompt neutrons emitted from 252 Cf spontaneous fission. Methods: Measurements with the Chi-Nu array provide experimental data for coincident neutrons tagged with a fission chamber signal with 10° angular resolution and 1-ns timing resolution for time-of-flight energy calculations. The experimental results are compared to simulations produced by the fission event generators cgmf, freya, and mcnpx-polimi ipol(1) = 1. Results: We find that the measurements and the simulations all exhibit anisotropic neutron emission, although differences between fission event generators are evident. In conclusion, this work shows that the dependence of detected neutron energy on the energy of another neutron detected in coincidence, although weak, is non-negligible, indicating that there may be correlations in energy between two neutrons emitted in the same fission event..

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boron nitride neutron detector with the ability for detecting both thermal and fast neutrons

The detection of fast neutrons is regarded technically challenging because the interaction probability of fast neutron with matter is extremely low. Based on our recent development of hexagonal boron nitride (BN) semiconductor thermal neutron detectors with a record high efficiency of 59%, we report here the feasibility studies of BN detectors for detecting fast neutrons. A BN detector with a detection area of 2.1 cm 2 was fabricated from a 90 $μ$m thick BN epilayer. In the presence of a bare Cf-252 source emitting fast neutrons ranging from 1 to 9 MeV, the detection efficiency was estimated to be about 0.1%. Furthermore, the measured mean free path of fast neutron in BN is about 7.6 cm. Together with the capability of BN for thermal neutron detection, the present results indicate that by incorporating BN with a large thickness, BN neutron detectors are expected to possess the unique capability of directly detecting thermal to fast neutrons as well as outstanding features resulting from the ultrawide bandgap of BN. The identification of a single material that is sensitive to both thermal and fast neutrons is valuable for the development of novel neutron detection technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

{sup 4}H-SiC neutron sensors based on ion implanted {sup 10}B neutron converter layer

In the framework of the I{sub S}MART project the main aim is to develop an innovative complete radiation detection system based on silicon carbide technology in view to detect neutrons (thermal and fast) and photons for harsh environments. In the present work two geometries have been realized based on ion implantation of boron. In the first geometry, {sup 10}B ions have been implanted into the Al metallic contact to create the neutron converter layer. In the second geometry one single process has been used to realize both the p+-layer and the neutron converter layer. The technological processes followed to fabricate these detectors, with a study of their electrical behavior and their responses under thermal neutron irradiations are addressed in this paper. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study Of Short-Range Correlations With 6-9 GeV/c Protons

We studied the {sup 12}C(p,2p+n) reaction at beam momenta of 5.9, 8.0 and 9.0 GeV/c. For quasielastic (p,2p) events we reconstructed p{sub f}, the momentum of the knocked-out proton before the reaction;, p{sub f} was then compared (event-by-event) with p{sub n}, the measured, coincident neutron momentum. For |p{sub n}|>k{sub F} = 0.220 GeV/c(the Fermi momentum) a strong back-to-back directional correlation between p{sub f} and p{sub n} was observed, indicative of short-range n-p correlations. From these data we concluded that for nuclear protons with momenta >0.275 GeV/c, 92{+-}18% have correlated neutron partners. This result was recently corroborated by an experiment with 4.6 GeV electrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fissile and fertile nuclear material measurements using a new differential die-away self-interrogation technique

This paper presents a new technique for the measurement of fissile and fertile nuclear materials in spent fuel and plutonium laden materials such as mixed oxide (MOX) fuel. The technique, called differential die-away self-interrogation, is similar to traditional differential die-away analysis, but it does not require a pulsed neutron generator or pulsed beam accelerator, and it can measure the fertile mass in addition to the fissile mass. The new method uses the spontaneous fission neutrons from {sup 244}Cm in spent fuel and {sup 240}Pu effective neutrons in MOX as the 'pulsed' neutron source with an average of {approx} 2.7 neutrons per pulse. The time correlated neutrons from the spontaneous fission and the subsequent induced fissions are analyzed as a function of time to determine the spontaneous fission rate, the induced fast-neutron fissions, and the induced thermal-neutron fissions. The fissile mass is determined from the induced thermal-neutron fissions that are produced by reflected thermal neutrons that originated from the spontaneous fission reaction. The sensitivity of the fissile mass measurement is enhanced by the use of two measurements, with and without a cadmium liner between the sample and the hydrogenous moderator. The fertile mass is determined from the multiplicity analysis of the neutrons detected soon after the initial triggering neutron is detected. The method obtains good sensitivity by the optimal design of two different neutron die-away regions: a short die-away for the neutron detector region and a longer die-away for the sample interrogation region.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of using gallium nitride for ionizing radiation detection

With the largest band gap energy of all commercial semiconductors, GaN has found wide application in the making of optoelectronic devices. It has also been used for photodetection such as solar blind imaging as well as ultraviolet and even X-ray detection. Unsurprisingly, the appreciable advantages of GaN over Si, amorphous silicon (a-Si:H), SiC, amorphous SiC (a-SiC), and GaAs, particularly for its radiation hardness, have drawn prompt attention from the physics, astronomy, and nuclear science and engineering communities alike, where semiconductors have traditionally been used for nuclear particle detection. Several investigations have established the usefulness of GaN for alpha detection, suggesting that when properly doped or coated with neutron sensitive materials, GaN could be turned into a neutron detection device. Work in this area is still early in its development, but GaN-based devices have already been shown to detect alpha particles, ultraviolet light, X-rays, electrons, and neutrons. Furthermore, the nuclear reaction presented by {sup 14}N(n,p){sup 14}C and various other threshold reactions indicates that GaN is intrinsically sensitive to neutrons. This review summarizes the state-of-the-art development of GaN detectors for detecting directly and indirectly ionizing radiation. Particular emphasis is given to GaN's radiation hardness under high-radiation fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling Explosives and Contraband Detection with Neutron Resonant Attenuation. Year 1 of 3 Summary

Material Identification by Resonant Attenuation is a technique that measures the energy-dependent attenuation of 1-10 MeV neutrons as they pass through a sample. Elemental information is determined from the neutron absorption resonances unique to each element. With sufficient energy resolution, these resonances can be used to categorize a wide range of materials, serving as a powerful discrimination technique between explosives, contraband, and other materials. Our proposed system is unique in that it simultaneously down-scatters and time tags neutrons in scintillator detectors oriented between a d-T generator and sample. This allows not only for energy measurements without pulsed neutron beams, but for sample interrogation over a large range of relevant energies, vastly improving scan times. Our system’s core advantage is a potential breakthrough ability to provide detection discrimination of threat materials by their elemental composition (e.g. water vs. hydrogen peroxide) without opening the container. However, several technical and computational challenges associated with this technique have yet to be addressed. There are several open questions: what is the sensitivity to different materials, what scan times are necessary, what are the sources of background, how do each of these scale as the detector system is made larger, and how can the system be integrated into existing scanning technology to close current detection gaps? In order to prove the applicability of this technology, we will develop a validated model to optimize the design and characterize the uncertainties in the measurement, and then test the system in a real-world scenario. This project seeks to perform R&D and laboratory tests that demonstrate proof of concept (TRL 3) to establishing an integrated system and evaluating its performance (TRL 4) through both laboratory tests and a validated detector model. The validated model will allow us to explore our technology’s benefits to explosive detection in various applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact magnetic proton recoil spectrometer for measurement of deuterium-tritium neutrons

A new compact magnetic proton recoil (MPR) neutron spectrometer has been designed for precise measurement of deuterium-tritium (DT) neutrons. This design is presented emphasizing the magnetic analyzing system, which is based on a compact quadrupole-dipole (QD) electromagnet. The focal plane detector (FPD) is also discussed with respect to application for the next step. The characteristics of the MPR spectrometer were calculated by using Monte Carlo simulation. A preliminary experiment was performed to test the magnetic analyzing system and the proton images of the FPD. Since the QD electromagnet design allows for a larger foil thickness and solid angle to be utilized, the MPR spectrometer defined in this paper can achieve neutron detection efficiency more than 5 × 10{sup −7} at an energy resolution of 1.5% for measuring DT neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-10 ABUNCL Prototype Initial Testing

The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Coincidence Counting With Boron-Based Alternative Neutron Detection Technology at Pacific Northwest National Laboratory (PNNL) for the development of a 3 He proportional counter alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a system based upon 10 B-lined proportional tubes in a configuration typical for 3 He-based coincidence counter applications. This report provides results of initial testing of an Alternative Boron-Based Uranium Neutron Coincidence Collar (ABUNCL) design built by General Electric Reuter-Stokes. Several configurations of the ABUNCL models, which use 10 B-lined proportional counters in place of 3 He proportional counters for the neutron detection elements, were previously reported. The ABUNCL tested is of a different design than previously modeled. Initial experimental testing of the as-delivered passive ABUNCL was performed, and modeling will be conducted. Testing of the system reconfigured for active testing will be performed in the near future, followed by testing with nuclear fuel.

Kouzes, Richard T.↗

Lithium indium diselenide: A new scintillator for neutron imaging

Lithium indium diselenide, 6 LiInSe 2 or LISe, is a newly developed neutron detection material that shows both semiconducting and scintillating properties. The 24% atomic density of 6 Li yields a thermal neutron mean free path of only 920 μm. This paper reports on the performance of LISe crystals in scintillation mode for its potential use as a converter screen for thermal/cold neutron imaging. The spatial resolution of LISe, determined using a 10% value of the Modulation Transfer Function (MTF), was found to not scale linearly with thickness. Crystals having a thickness of 450 μm or larger resulted in an average spatial resolution of 67 μm, and the thinner crystals exhibited an increase in spatial resolution down to the Nyquist frequency of the CCD. The highest measured spatial resolution of 198 μm thick LISe (27 μm) outperforms a commercial 50 μm thick ZnS(Cu): 6 LiF scintillation screen (100 μm) by more than a factor of three. For the thicknesses considered in this study, it has been found that the light yield of LISe did not scale with its thickness, suggesting the need for optimizing the synthesis to enhance the scintillation mechanism. Absorption measurements indicate that the 6 Li concentration is uniform throughout the samples and its absorption efficiency as a function of thickness follows general nuclear theory, indicating that the variation in apparent brightness is likely due to a combination of particle escape, light transport, and activation of the scintillation mechanisms. As a result, the presence of 115 In and its long-lived 116 In activation product did not result in ghosting (memory of past neutron exposure), demonstrating potential for using LISe for imaging transient systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

DHS-STEM Summer Internship Report

Over the course of the last twelve weeks, I have been contributing to efforts in high efficiency solid state thermal neutron detection at Lawrence Livermore National Laboratory (LLNL) as a DHS HS-STEM intern. Reliable, high efficiency solid state thermal neutron detectors are desired to replace conventional 3 He gas filled tube technologies which have fieldability issues due to size, high operating voltage requirements, sensitivity to microphonics, and the recently rapidly diminishing supply of 3 He gas. Under the supervision of Rebecca Nikolić and Qinghui Shao, I have been developing an experimental plan to modify the doping profile of LLNL’s silicon-based pillar structured thermal neutron detector. The overall goal of this work is to reduce the capacitance and leakage current of the Pillar detector to enable the device area to be increased while maintaining a high thermal neutron detection efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Surrogate Measurements of Actinide (n,2n) Cross Sections with NeutronSTARS

Directly measuring (n,2n) cross sections on short-lived actinides presents a number of experimental challenges. The surrogate reaction technique is an experimental method for measuring cross sections on short-­lived isotopes, and it provides a unique solution for measuring (n,2n) cross sections. This technique involves measuring a charged-­particle reaction cross section, where the reaction populates the same compound nucleus as the reaction of interest. To perform these surrogate (n,2n) cross section measurements, a silicon telescope array has been placed along a beam line at the Texas A&M University Cyclotron Institute, which is surrounded by a large tank of gadolinium-doped liquid scintillator, which acts as a neutron detector. The combination of the charge-particle and neutron-detector arrays is referred to as NeutronSTARS. In the analysis procedure for calculating the (n,2n) cross section, the neutron detection efficiency and time structure plays an important role. Due to the lack of availability of isotropic, mono-energetic neutron sources, modeling is an important component in establishing this efficiency and time structure. This report describes the NeutronSTARS array, which was designed and commissioned during this project. It also describes the surrogate reaction technique, specifically referencing a 235 U(n,2n) commissioning measurement that was fielded during the past year. Advanced multiplicity analysis techniques have been developed for this work, which should allow for efficient analysis of 241 Pu(n,2n) and 239 Pu(n,2n) cross section measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plutonium measurements with a fast-neutron multiplicity counter for nuclear safeguards applications

Measurements were performed at the Joint Research Centre in Ispra, Italy to field test a fast-neutron multiplicity counter developed at the University of Michigan. The measurements allowed the assessment of the system's photon discrimination abilities, efficiency when measuring neutron multiplicity, ability to characterize 240 Pu eff mass, and performance relative to a currently deployed neutron coincidence counter. We describe how this work is motivated by the need to replace and improve upon 3 He neutron detection systems for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron spectrometry with He-3 proportional counters

Helium filled proportional counters are widely used in the field of neutron detection and spectrometry. In this work the response of a commercially available He-3 counter is studied experimentally and calculated with Monte Carlo for the neutron energy range from 230 keV up to about 7 MeV. The calculated response of the system is used to determine neutron yield energy distribution emitted from an extended {sup nat}U/Pb assembly irradiated with 1.6 GeV deuterons. The results are in acceptable agreement with the calculated neutron distribution with DCM-DEM code. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational Safeguards Analysis of PWR Spent Nuclear Fuel in Dry Storage - 17435

The master plan for spent nuclear fuel (SNF) management in Korea recently adopted by Korean atomic energy promotion council. According to the master plan, the detailed practical and R and D strategies for SNF transferring, storage and disposal should be determined in the near future. Besides, it is also necessary to make plan how to secure SNF at each step in terms of nuclear safeguards, safety, security and nonproliferation. Several nondestructive analysis (NDA) techniques have been studied for assuring the safety of SNF in PWR methods. Obviously, gamma-ray is most dominant radiation emitted by SNF so several gamma-ray measurement methods have been developed and applied for the purpose of SNF monitoring. Those methods, however, suffer from a lack of nuclear data and interfering background radiation. To date, several neutron measurement methods have been developed as a solution to the problem of gamma-ray methods. Korea Institute of Nuclear Nonproliferation and Control (KINAC) currently develops a new novel technique of fast neutron detection for spent fuel monitoring at dry spent fuel storage facilities. As the first step, a computational program has been developed in order to evaluate neutron flux on the surface of PWR dry storage cask and study for some potential sabotage events. Typically, neutron flux on the surface of dry storage cask can be evaluated via two steps. The source term, based on burn-up rate of SNF, its cooling time and others related to operation condition at nuclear power plants, can be firstly defined by ORIGEN code. The surface flux can be then evaluated via MCNP code. These two separated steps are complicated and time consuming so KINAC developed a new algorithm and user-interface, coupled ORIGEN and MCNP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A technique for studying (n,p) reactions of astrophysical interest using radioactive beams with SECAR

The formation of nuclei in slightly proton-rich regions of the neutrino-driven wind of core-collapse supernovae could be attributed to the neutrino-p process (νp-process). As it proceeds via a sequence of (p,γ) and (n,p) reactions, it may produce elements in the range of Ni and Sn, considering adequate conditions. Recent studies identify a number of decisive (n,p) reactions that control the efficiency of the νp-process. The study of one such (n,p) reaction via the measurement of the reverse (p,n) in inverse kinematics was performed with SECAR at NSCL/FRIB. Proton-induced reaction measurements, especially at the mass region of interest, are notably difficult since the recoils have nearly identical masses as the unreacted projectiles. Such measurements are feasible with the adequate separation level achieved with SECAR, and the in-coincidence neutron detection. Adjustments of the SECAR system for the first (p,n) reaction measurement included the development of new ion beam optics, and the installation of the neutron detection system. The aforementioned developments along with a discussion on the preliminary results of the p(58Fe,n)58Co reaction measurement are presented.

Tsintari, P↗