Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

PERFORMING DIAGNOSTICS ON THE SPALLATION NEUTRON SOURCE VISION BEAM LINE TO ELIMINATE HIGH VIBRATION LEVELS AND PROVIDE A SUSTAINABLE OPERATION

The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) provides variable energy neutrons for a variety of experiments. The neutrons proceed down beam lines to the experiment hall, which houses a variety of experiments and test articles. Each beam line has one or more neutron choppers which filter the neutron beam based on the neutron energy by using a rotating neutron absorbing material passing through the neutron beam. Excessive vibration of the Vision beam line, believed to be caused by the T0 chopper, prevented the Vision beam line from operating at full capacity. This problem had been addressed several times by rebalancing/reworking the T0 beam chopper but the problem stubbornly persisted. To determine the cause of the high vibration, dynamic testing was performed. Twenty-seven accelerometer and motor current channels of data were collected during drive up, drive down, coast down, and steady-state conditions; resonance testing and motor current signature analysis were also performed. The data was analyzed for traditional mechanical/machinery issues such as misalignment and imbalance using time series analysis, frequency domain analysis, and operating deflection shape analysis. The analysis showed that the chopper base plate was experiencing an amplified response to the excitation provided by the T0 beam chopper. The amplified response was diagnosed to be caused by higher than expected base plate flexibility, possibly due to improper grouting or loose floor anchors. Based on this diagnosis, a decision was made to dismantle the beam line chopper and remount the base plate. Neutron activation of the beam line components make modifications to the beam line especially expensive and time consuming due to the radiation handling requirements, so this decision had significant financial and schedule implications. It was found that the base plate was indeed loose because of improper grouting during its initial installation. The base plate was modified by splitting it into multiple sections, isolating the T0 chopper from the rest of the beam line, and each section was then reinstalled and re-grouted. After these modifications, the vibration levels were reduced by a factor of 30. The reduction in vibration level was sufficient to allow the Vision beam line to operate at full capacity for the first time since its completed construction date.

: Diagnostics↗

Strongly paired fermions: Cold atoms and neutron matter

Experiments with cold Fermi atoms can be tuned to probe strongly-interacting fluids that are very similar to the low-density neutron matter found in the crusts of neutron stars. In contrast to traditional superfluids and superconductors, matter in this regime is very strongly paired, with gaps of the order of the Fermi energy. We compute the T=0 equation of state and pairing gap for cold atoms and low-density neutron matter as a function of the Fermi momentum times the scattering length. Results of quantum Monte Carlo calculations show that the equations of state are very similar. The neutron matter pairing gap at low densities is found to be very large but, except at the smallest densities, significantly suppressed relative to cold atoms because of the finite effective range in the neutron-neutron interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Energy Selective Neutron Imaging at the PULSTAR Reactor

Neutron imaging is complementary to X-ray imaging where both are used to investigate the internal features of objects nondestructively. Historically, it only began three years after discovery of the neutron in 1932, however, neutron radiographs with reasonable quality were first made in the mid-fifties. Conventionally, the image is produced by placing the object between the neutron source and a two-dimensional position sensitive detector. The source commonly has a full energy spectrum (white beam) of thermal or cold neutrons to obtain high intensity in the sample and short exposure time. As a result, all neutron energies contribute to the obtained radiograph. Since the interaction of the neutron with matter is energy dependent, different energies produce different contrast on the radiographic image, hence, additional information about the object can be obtained. Neutron imaging that utilizes a narrow spectrum of energy instead of white beam is called energy selective neutron imaging. Many techniques have been explored to select a narrow band of neutron energy for the use in imaging such as the use velocity selectors, double crystal Monochromators, and time of flight techniques (at pulsed neutron sources). The PULSTAR reactor of North Carolina State University (1 MWth) currently has an operational neutron powder diffractometer (NPD) installed on beam tube no. 4, which was designed for neutron scattering experiments and can provide a monoenergetic beam of neutrons. The neutron energy could be selected by diffraction means using a Si bent perfect crystal as a Monochromator. In this work, an investigation of energy selective neutron imaging at the NPD is discussed in terms of the system performance and the ability of material discrimination on a test sample by observing the contrast variations of the neutron radiographs obtained using different neutron energies. Energy selective neutron imaging experiment was successfully tested at the PULSTAR reactor's NPD. Although, the uniform region is small and the exposure time is long in comparison with the NIF, both facilities exhibit similar spatial resolution which is a very important characteristic for any imaging facility. The contrast variation of neuron radiographs for the test sample obtained at different energies indicated a potential advantage for using energy selective neutron imaging over the white beam. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Detection in the A2 Collaboration Experiment on Neutral Pion Photo-production on Neutron

Neutron detection is of crucial importance for the neutral pion photo-production study on a neutron target that now is in progress at MAMI. Two electro-magnetic calorimeters, based on NaI and BaF 2 crystals, are used in the A2 experiment. While these calorimeters are optimized for pion decay photon detection, they have a reason able efficiency for neutron detection also. The paper describes the method, which has been used to measure this efficiency using the same data taken for pion photo-production study on deuterium target with tagged photon been of 800 MeV maximal energy. As a result, the detection efficiency is a rising function of neutron momentum that reaches 40% near 1 GeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian estimation of cross-section and errors of experiment and calculation for accurate prediction of neutronic characteristics

In some experiments, there might be a correlation of experimental errors such as an error caused by fabrication. The correlation of calculation errors also might exist among analyses of experiments. In the present study, considering these correlations, the cross-section and errors of experiment and calculation are adjusted for the accurate prediction of neutronic characteristics. The adjustment method is derived based on Bayesian theory. The 'a posteriori' distributions of cross-section and errors of experiment and calculation are obtained by the derivation. The case study is performed by using the benchmarks of light-water moderated experiments reported in ICSBEP. The error from fuel rod fabrication and measurement are included in the experiment error, and the error from the simplification of the benchmark model is included in the calculation error. Since these errors have a positive correlation among the benchmarks, the prediction accuracy is expected to be improved by considering these correlations. For the sensitivity analysis of the correlation among benchmarks, the correlation coefficient of experiment error and that of calculation error is assumed from 0.0 to 0.9. The results indicate that the prediction accuracy of the multiplication factor can be improved by increasing the correlation coefficient of experiment error and that of calculation error. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal scattering law for ice based on neutron time-of-flight experiments carried out at the SEQUOIA spectrometer at the Oak Ridge National Laboratory

Precise estimation of neutron thermalization in moderators relies on high-fidelity thermal scattering cross-section data governed by the thermal scattering law (TSL). The Institut de Radioprotection et de Sûreté Nucléaire (IRSN) has been working on the development of improved TSL for light water ice. Many polymorphic phases of light water ice exist depending on the thermodynamic conditions. The most common type of ice at standard pressure and temperature below water freezing point (273.15 K) is ice-Ih. It is essential to have high-resolution experimental double differential data for developing and/or validating TSL for moderator materials.Existing experimental double-differential scattering data for ice-Ih are extremely sparse and of limited quality. New high-quality double-differential measurements for ice-Ih over multiple temperatures and incident neutron energies would directly support the validation and improvement of ice-Ih TSL models for criticality safety applications.Series of time-of-flight (TOF) inelastic neutron scattering experiments on ice-Ih at temperatures starting at 271 K and down to 6 K, have been carried out at the SEQUOIA spectrometer at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), United States. The experiments have been performed for incident neutron energies, Ei= 11, 55, 160, 250, and 600 meV, to explore different excitation energies in the vibrational phonon spectrum. This paper presents the thermodynamic conditions and the details of the TOF measurements on ice-Ih and the derived phonon spectrum from the experimentally measured double differential data. A study of the variation of the phonon spectrum of ice-Ih as a function of temperature is highlighted, and a preliminary TSL evaluation is developed based on the experimental phonon spectrum.

Jaiswal, V↗

Phase diagram and neutron spin resonance of superconducting NaFe 1 - x Cu x As

In this paper, we use transport and neutron scattering to study the electronic phase diagram and spin excitations of NaFe 1-x Cu x As single crystals. Similar to Co- and Ni-doped NaFeAs, a bulk superconducting phase appears near x≈2% with the suppression of stripe-type magnetic order in NaFeAs. Upon further increasing Cu concentration the system becomes insulating, culminating in an antiferromagnetically ordered insulating phase near x≈50%. Using transport measurements, we demonstrate that the resistivity in NaFe 1-x Cu x As exhibits non-Fermi-liquid behavior near x≈1.8%. Our inelastic neutron scattering experiments reveal a single neutron spin resonance mode exhibiting weak dispersion along c axis in NaFe 0.98 Cu 0.02 As. The resonance is high in energy relative to the superconducting transition temperature T c but weak in intensity, likely resulting from impurity effects. These results are similar to other iron pnictides superconductors despite that the superconducting phase in NaFe 1-x Cu x As is continuously connected to an antiferromagnetically ordered insulating phase near x≈50% with significant electronic correlations. Finally, therefore, electron correlations is an important ingredient of superconductivity in NaFe 1-x Cu x As and other iron pnictides.

36 MATERIALS SCIENCE↗

FY2018 Annual report on Darren Bleuel's research activities for neutron imaging facility development

The primary research activities in Fiscal Year 2018 by Dr. Darren Bleuel in support of the neutron imaging (NI) facility development can be categorized into three major projects: improvements in the analysis of equipment damage testing by neutron irradiation, experiments to measure the neutron production by deuterons of alternative gas targets and beam stopping volumes, and development of neutron spectral-measurement methods with non-pulsed beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Portable Neutron Sensors for Emergency Response Operations

This article presents the experimental work performed in the area of neutron detector development at the Remote Sensing Laboratory–Andrews Operations (RSL-AO) sponsored by the U.S. Department of Energy, National Nuclear Security Administration (NNSA) in the last four years. During the 1950s neutron detectors were developed mostly to characterize nuclear reactors where the neutron flux is high. Due to the indirect nature of neutron detection via interaction with other particles, neutron counting and neutron energy measurements have never been as precise as gamma-ray counting measurements and gamma-ray spectroscopy. This indirect nature is intrinsic to all neutron measurement endeavors (except perhaps for neutron spin-related experiments, viz. neutron spin-echo measurements where one obtains μeV energy resolution). In emergency response situations generally the count rates are low, and neutrons may be scattered around in inhomogeneous intervening materials. It is also true that neutron sensors are most efficient for the lowest energy neutrons, so it is not as easy to detect and count energetic neutrons. Most of the emergency response neutron detectors are offshoots of nuclear device diagnostics tools and special nuclear materials characterization equipment, because that is what is available commercially. These instruments mostly are laboratory equipment, and not field-deployable gear suited for mobile teams. Our goal is to design and prototype field-deployable, ruggedized, lightweight, efficient neutron detectors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Additive manufacturing of composite neutron absorbing components

Collimators and other components for use in neutron scattering experiments or to provide neutron shielding in nuclear reactors or accelerator based neutron sources are produced by additive manufacturing from multiple different types of material, such as boron carbide (B4C), steel, isotopically enriched boron carbide (10B4C), and blends thereof.

Anderson, David C.↗

Method for producing neutron collimators using additive manufacturing

Collimators and other components for use in neutron scattering experiments or to provide neutron shielding in nuclear reactors or accelerator based neutron sources are produced by additive manufacturing from neutron absorbing material, such as boron carbide (B4C) or isotopically enriched boron carbide (10B).

Anderson, David C.↗

Mott localization in a pure stripe antiferromagnet Rb 1 - δ Fe 1.5 - σ S 2

A combination of neutron diffraction and angle-resolved photoemission spectroscopy measurements on a pure antiferromagnetic stripe ${\mathrm{Rb}}_{1{-}{\delta}}{\mathrm{Fe}}_{1.5{-}{\sigma}}{\mathrm{S}}_{2}$ is reported here. A neutron diffraction experiment on a powder sample shows that a $98$% volume fraction of the sample is in the antiferromagnetic stripe phase with rhombic iron vacancy order and a refined composition of ${\mathrm{Rb}}_{0.66}{\mathrm{Fe}}_{1.36}{\mathrm{S}}_{2}$, and that only $2$% of the sample is in the block antiferromagnetic phase with $\sqrt{5}\times{}\sqrt{5}$ iron vacancy order. Furthermore, a neutron diffraction experiment on a single crystal shows that there is only a single phase with the stripe antiferromagnetic order with the refined composition of ${\mathrm{Rb}}_{0.78}{\mathrm{Fe}}_{1.35}{\mathrm{S}}_{2}$, while the phase with block antiferromagnetic order is absent. Angle-resolved photoemission spectroscopy measurements on the same crystal with the pure stripe phase reveal that the electronic structure is gapped at the Fermi level with a gap larger than 0.325 eV. The data collectively demonstrate that the extra $10$% iron vacancies in addition to the rhombic iron vacancy order effectively impede the formation of the block antiferromagnetic phase; the data also suggest that the stripe antiferromagnetic phase with rhombic iron vacancy order is a Mott insulator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvements in Fabrication of Elastic Scattering Foils Used to Measure Neutron Yield by the Magnetic Recoil Spectrometer

The magnetic recoil spectrometer uses a deuterated polyethylene polymer (CD 2 ) foil to measure neutron yield in inertial confinement fusion experiments. Higher neutron yields in recent experiments have resulted in primary signal saturation in the detector CR-39 foils, necessitating the fabrication of thinner CD 2 foils than established methods could provide. A novel method of fabricating deuterated polymer foils is described. The resulting foils are thinner, smoother, and more uniform in thickness than the foils produced by previous methods. Here, these new foils have successfully been deployed at the National Ignition Facility, enabling higher neutron yield measurements than previous foils, with no primary signal saturation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microphase separation in thin films of lamellar forming polydisperse di-block copolymers

Despite the ubiquity of polydispersity in chain lengths of di-block copolymers, its effects on microphase separation in thin films have eluded a clear understanding. In this paper, we have studied effects of polydispersity on the microphase separation in thin films of lamellar forming di-block copolymers using self-consistent field theory (SCFT) and neutron reflectivity experiments. Di-block copolymers containing a polydisperse block of poly(glycidylmethacrylate) (PGMA) connected to a near-monodisperse block poly(2-vinyl-4,4-dimethyl-d 6 azlactone) (PVDMA-d 6 ) are considered in this work. Effects of chain length polydispersity, film thickness, substrate–monomer and monomer–monomer interactions on the microphase segregation are studied using SCFT. The theoretical study reveals that in comparison to a film created with monodisperse di-block copolymers, an increase in polydispersity tends to decrease the number of lamellar strata that can be packed in a film of given thickness. This is a direct consequence of an increase in lamellar domain spacing with an increase in polydispersity index. Furthermore, it is shown that polydispersity induces conformational asymmetry and an increase in the polydispersity index leads to an increase in the effective Kuhn segment length of the polydisperse blocks. It is shown that the conformational asymmetry effects, which are entropic in origin and of increasing importance as film thickness decreases, drive the polydisperse blocks to the middle of the films despite favorable substrate interactions. These predictions are verified by results from neutron reflectivity experiments on thin films made from moderately polydisperse PGMA-PVDMA-d 6 di-block copolymer deposited on silicon substrates. In conclusion, results from SCFT are used to predict neutron reflectivity profiles, providing a facile and robust route to obtain useful physical insights into the structure of polydisperse diblock copolymers at interfaces.

36 MATERIALS SCIENCE↗

Response to 'Comment on 'Elastic incoherent neutron scattering operating by varying instrumental energy resolution: Principle, simulations, and experiments of the resolution elastic neutron scattering (RENS)'' [Rev. Sci. Instrum. 83, 107101 (2012)]

Recently [S. Magazu et al., Rev. Sci. Instrum. 82, 105115 (2011)] we have proposed a new method for characterizing, by neutron scattering, the dynamical properties of complex material systems, such as, the ones of interest in the biophysical field. This approach called Resolution Elastic Neutron Scattering, in short RENS, is based on the detection of the elastically scattered neutron intensity as a function of the instrumental energy resolution. By experimental, theoretical, and numerical findings, we have pointed out that an inflection point occurs in the elastic intensity when the system relaxation time approaches the instrumental energy resolution time. This approach, differently from quasi-elastic neutron scattering (QENS), gives the chance to evaluate the system relaxation times without using pre-defined models that can be wrong and/or misleading. Here, we reply to a Comment on the above-mentioned main paper in which Wuttke proposes a different approach to evaluate the above-mentioned inflection point; on this regard, it should be noticed that the existence of the inflection point, which is the main topic of our work, is not questioned and that the approach proposed by Wuttke in the Comment, although valid for a class of dynamical processes, is not applicable when different and distinct processes occur simultaneously at different time scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗