Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nitrogen Dioxide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Planetary Aeronomy: NO2 In the Martian Atmosphere - 2

The transmission curve of the Martian atmosphere derived by Opik is compared with transmission curves of an atmosphere containing various amounts of nitrogen dioxide. It is found that the amount of 6 x l0(exp 18) sq cm column NO2 (or even less) given by Sinton as an upper limit for the Martian NO2 content could adequately explain the phenomenon of the blue haze. This finding made it worthwhile to investigate the effect of the temperature and pressure sensitive equilibrium 2 NO2 reversibly yields N204 upon the total NO2 content and the altitude-number density distributions of NO2 and N204. Computations were carried out for surface temperatures of 273 K, 243 K, 213 K, and 183 K and for three different temperature distributions. The discussion of the results leads to the suggestion of several important new experiments.

Warneck, P.↗

Experimental and Numerical Investigation of Adsorption/Desorption in Packed Sorption Beds Under Ideal and Non-Ideal Flows

The importance of the wall effect on packed beds in the adsorption and desorption of carbon dioxide, nitrogen, and water on molecular sieve 5A of 0.127 cm in radius is examined experimentally and with one-dimensional computer simulations. Experimental results are presented for a 22.5-cm long by 4.5-cm diameter cylindrical column with concentration measurements taken at various radial locations. The set of partial differential equations are solved using finite differences and Newman's method. Comparison of test data with the axial-dispersed, non-isothermal, linear driving force model suggests that a two-dimensional model (submitted to Separation Science and Technology) is required for accurate simulation of the average column breakthrough concentration. Additional comparisons of test data with the model provided information on the interactive effects of carrier gas coadsorption with CO2, as well as CO2-H2O interactions.

Mohamadinejad, H.↗

The nu(sub 2) and 2nu(sub 2) - nu(sub 2) bands of N-14 (16)O2: Electron Spin-Rotation and Hyperfine Contact Resonances in the (010) Vibrational State

High-resolution Fourier transform spectra covering the 720-9-10/ cm spectral region have been used to perform a reanalysis of the 2nu(sub 2) band ((010) - (000) vibrational transition) together with the first analysis of the nu(sub 2) - nu(sub 2) hot band of nitrogen dioxide ((020)-(010) vibrational transition). The high-quality spectra show that, for numerous nu(sub 2) lines, the hyperfine structure is easily observable in the case of resonances due to the hyperfine Fermi-type operator. By performing a full treatment of the spin-rotation and of the hyperfine operators, a near line list of the nu(sub 2) band (positions and intensities) has been generated, and it is in excellent agreement with the experimental spectrum. Also, a thorough analysis of the -2nu(sub 2) nu(sub 2) hot band has been performed leading to an extended set of new (020) spin-rotation levels, These levels, together with the (100), (020), (001) spin-rotation levels deduced previously from the analysis of thenu(sub 1), 2nu(sub 2), and nu(sub 3) cold bands performed in the 6.3 - to 7.5 microns spectral range were least-squares fitted, allowing one to derive a new set of vibrational band centers and rotational. spin-rotation, and interaction constants for the {(100)(020)(001)} interacting states of N-14(16)O2.

Perrin, A.↗

Indicator Devices for Detection of Trace Gaseous Hydrazines

The relatively recent decrease in the acceptable time-weighted-average for hydrazines from 100 parts-per-billion (ppb) to 10 ppb rendered many trace hydrazine detectors either insensitive or inaccurate. Development of a rapid detection method for hydrazines at the new 10-ppb concentration was necessary so that test area personnel could reliably assess airborne hydrazines concentrations of a potentially contaminated area prior to entry. The reduction of Au(III) to Au(0) by hydrazines is a well characterized reaction and application of the corresponding yellow to purple color change was selected as a potentially useful means for detection of trace hydrazines in air. Tests with small quantities of KAuCl4 deposited on a variety of substrates were conducted using verified sources of 1,1-dimethylhydrazine, methylhydrazine, and hydrazine at approximately 10 ppb in air. Substrates tested were glass fiber filter paper, glass beads, anion exchange resin (AuCl4- form), and diatomaceous earth. The most successful of these substrates were glass fiber filter paper and diatomaceous earth. The KAuC14 impregnated glass fiber filter paper appeared to be somewhat light sensitive so further tests were conducted using the diatomaceous earth substrate. KAuCl4 concentration, substrate particle size, and sampler configuration were evaluated. Based on these tests, the device selected for further evaluation was a 5mm OD by 50mm glass tube containing 0.02-0.03g of 45/60 mesh diatomaceous earth coated with 2 percent KAuCl4. When connected to a sampling pump, response of the device to changes in relative humidity, ambient light, and high levels of other fluids, which might also be found in a propellant test area, was evaluated. False positive responses were not detected for exposures to relative humidity changes from 10 to 80 percent, sunlight for greater than 10 minutes, or percent levels of ammonia, isopropyl alcohol, nitrogen dioxide, and hydrogen. In addition, body emissions did not produce a false positive response in view of potential application for use inside protective clothing. The device was shown to reliably detect less than 10 ppb of the hydrazines tested using a 10 to 20L sample followed by a 2 to 5 minute color development time. Some field tests were conducted in parallel with conventional acidic firebrick sorbent tubes. There was generally very good agreement between the devices and firebrick sorbent tubes when greater than 10 ppb of a hydrazine was present.

Dee, Lou A.↗

Tropospheric Formaldehyde Measurements from the ESA GOME Instrument

The Global Ozone Monitoring Experiment (GOME) was launched on the European Space Agency's ERS-2 satellite on April 20, 1995. GOME measures the Earth's atmosphere in the nadir geometry, using a set of spectrometers that cover the UV and visible (240-790 nm) at moderate resolution (0.2 nm in the UV, 0.4 nm in the visible), employing silicon diode array detectors. GOME takes some 30,000 spectra per day, obtaining full global coverage in three days. We directly fit GOME radiance spectra using nonlinear least-squares analysis to obtain column amounts of several trace species with significant tropospheric concentrations, including ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), and formaldehyde (HCHO). Measurements of HCHO due to biogenic activity in the troposphere are presented here.

Chance, K.↗

Monitoring Air Quality from Space using AURA Data

Measurements from the Earth Observing System (EOS) AURA mission will provide a unique perspective on air quality monitoring. Ozone, nitrogen dioxide, formaldehyde and aerosols from the Ozone Monitoring Instrument (OMI) and carbon monoxide from the Tropospheric Emission Spectrometer (TES) will be simultaneously measured with the spatial resolution and coverage needed for improving our understanding of air quality. AURA data products useful for air quality monitoring will be given.

Gleason, James F.↗

Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.

NASA Center ARC↗

Remote Sensing from Geostationary Orbit: GEO TROPSAT, A New Concept for Atmospheric Remote Sensing

The Geostationary Tropospheric Pollution Satellite (GEO TROPSAT) mission is a new approach to measuring the critical constituents of tropospheric ozone chemistry: ozone, carbon monoxide, nitrogen dioxide, and aerosols. The GEO TROPSAT mission comprises a constellation of three instruments flying as secondary payloads on geostationary communications satellites around the world. This proposed approach can significantly reduce the cost of getting a science payload to geostationary orbit and also generates revenue for the satellite owners. The geostationary vantage point enables simultaneous high temporal and spatial resolution measurement of tropospheric trace gases, leading to greatly improved atmospheric ozone chemistry knowledge. The science data processing, conducted as a research (not operational) activity, will provide atmospheric trace gas data many times per day over the same region at better than 25 km ground footprint. The high temporal resolution identifies short time scale processes, diurnal variations, seasonal trends, and interannual variation.

Little, Alan D.↗

Emissions of Trace Gases and Particles from Savanna Fires in Southern Africa

Airborne measurements made on initial smoke from 10 savanna fires in southern Africa provide quantitative data on emissions of 50 gaseous and particulate species, including carbon dioxide, carbon monoxide, sulfur dioxide, nitrogen oxides, methane, ammonia, dimethyl sulfide, nonmethane organic compounds, halocarbons, gaseous organic acids, aerosol ionic components, carbonaceous aerosols, and condensation nuclei (CN). Measurements of several of the gaseous species by gas chromatography and Fourier transform infrared spectroscopy are compared. Emission ratios and emission factors are given for eight species that have not been reported previously for biomass burning of savanna in southern Africa (namely, dimethyl sulfide, methyl nitrate, five hydrocarbons, and particles with diameters from 0.1 to 3 microns). The emission factor that we measured for ammonia is lower by a factor of 4, and the emission factors for formaldehyde, hydrogen cyanide, and CN are greater by factors of about 3, 20, and 3 - 15, respectively, than previously reported values. The new emission factors are used to estimate annual emissions of these species from savanna fires in Africa and worldwide.

Sinha, Parikhit↗

High Resolution Spectroscopy to Support Atmospheric Measurements

The major research activities performed during the cooperative agreement enhanced our spectroscopic knowledge of molecules of atmospheric interest such as H2O (water vapor), O3 (ozone), HCN (hydrogen cyanide), CH4 (methane), NO2 (nitrogen dioxide) and CO (carbon monoxide). The data required for the analyses were obtained from two different Fourier Transform Spectrometers (FTS); one of which is located at the National Solar Observatory (NSO) on Kitt Peak, Arizona and the other instrument is located at the Pacific Northwest National Laboratories (PNNL) at Richland, Washington. The data were analyzed using a modified multispectrum nonlinear least squares fitting algorithm developed by Dr. D. Chris Benner of the College of William and Mary. The results from these studies made significant improvements in the line positons and intensities for these molecules. The measurements of pressure broadening and pressure induced line shift coefficients and the temperature dependence of pressure broadening and pressure induced shift coefficients for hundreds of infrared transitions of HCN, CO3 CH4 and H2O were also performed during this period. Results from these studies have been used for retrievals of stratospheric gas concentration profiles from data collected by several Upper Atmospheric Research Satellite (UARS) infrared instruments as well as in the analysis of high resolution atmospheric spectra such as those acquired by space-based, ground-based, and various balloon- and aircraft-borne experiments. Our results made significant contributions in several updates of the HITRAN (HIgh resolution TRANsmission) spectral line parameters database. This database enjoys worldwide recognition in research involving diversified scientific fields. The research conducted during the period 2003-2006 has resulted in publications given in this paper. In addition to Journal publications, several oral and poster presentations were given at various Scientific conferences within the United States and abroad.

Venkataraman, Malathy Devi↗

Zeeman Tuning Rates in the v3 Band of NO2

Zeeman spectra of the v3 fundamental (at approximately 1620 c/m) of nitrogen dioxide (14N02) have been recorded with magnetic fields of approximately 500 Gauss using a FTS (at the Kitt Peak National Observatory), as well as a tunable diode laser. At low magnetic fields the Zeeman effect is small compared to the spin-rotation interaction, and the Zeeman tuning rates are expected to be linear with magnetic field. Measured tuning rates of the Q-branch (KA = 2 - 9, N = 2 - 6) sigma transitions are compared to those expected for 2Sigma transitions in low magnetic fields, 2mu ogB/(2N+l). These measurements are required in the data analysis of an ultra-sensitive (pptv) in situ detector based on magnetic-rotation spectroscopy.

Mahon, C. H.↗

UV Induced Oxidation of Nitric Oxide

Nitric oxide in a gaseous stream is converted to nitrogen dioxide using oxidizing species generated at least in part using in situ UV radiation sources. The sources of the oxidizing species include oxygen and/or hydrogen peroxide. The oxygen may be a component of the gaseous stream or added to the gaseous stream, preferably near a UV radiation source, and is converted to ozone by the UV irradiation. The hydrogen peroxide is decomposed through a combination of vaporization and UV irradiation. The hydrogen peroxide is preferably stored at stable concentration levels, i.e., approximately 50% by volume and increased in concentration in a continuous process preceding vaporization within the flow channel of the gaseous stream and in the presence of the UV radiation sources.

Parrish, Clyde, F.↗

Algorithm for NO2 Vertical Column Retrieval from the Ozone Monitoring Instrument

We describe the operational algorithm for the retrieval of stratospheric, tropospheric, and total column densities of nitrogen dioxide NO2 from earthshine radiances measured by the Ozone Monitoring Instrument (OMI), aboard the EOS-Aura satellite. The algorithm uses the DOAS method for the retrieval of slant column NO densities. Air mass factors (AMFs) calculated from a stratospheric NO2 profile are used to make initial estimates of the vertical column density. Using data collected over a 24-h period, a smooth estimate of the global stratospheric field is constructed. Where the initial vertical column densities exceed the estimated stratospheric field, we infer the presence of tropospheric NO2, and recalculate the vertical column density (VCD) using an AMF calculated from an assumed tropospheric NO2 profile. The parameters that control the operational algorithm were selected with the aid of a set of data assembled from stratospheric and tropospheric chemical transport models. We apply the optimized algorithm to OMI data and present global maps of NO2 VCDs for the first time.

Bucsela, Eric J.↗

What You Need to Know About the OMI NO2 Data Product for Air Quality Studies

The standard nitrogen dioxide (NO2) data product, produced from measurements by the Ozone Monitoring Instrument (OMI), are publicly available online from the NASA GESDISC facility. Important data fields include total and tropospheric column densities, as well as collocated data for cloud fraction and cloud top height, surface albedo and snow/ice coverage, at the resolution of the OMI instrument (12 km x 26 km, at nadir). The retrieved NO2 data have been validated, principally under clear-sky conditions. The first public-release version has been available since September 2006. An improved version of the data product, which includes a number of new data fields, and improved estimates of the retrieval uncertainties will be released by the end of 2007. This talk will describe the standard NO2 data product, including details that are essential for the use of the data for air quality studies. We will also describe the principal improvements with the new version of the data product.

Celarier, E. A.↗

Evaluation of GOME Satellite Measurements of Tropospheric NO2 and HCHO using Regional Data from Aircraft Campaigns in the Southeastern United States

We compare tropospheric measurements of nitrogen dioxide (NO2) and formaldehyde (HCHO) from the Global Ozone Monitoring Experiment (GOME) satellite instrument with in situ measurements over eastern Texas and the southeast United States. On aveiage, the GOME and in situ measurements of tropospheric NO2 and HCHO columns are consistent despite pronounced sampling differences. The geometric mean in situ to GOME ratios over the campaign are 1.08 for NO2 and 0.84 for HCHO, with corresponding geometric standard deviations of 1.27 and 1.38. The correlation of the observed column spatial variability between the two NO2 measurement sets is encouraging before (r2 = 0.54, n = 18) and after (r2 = 0.67, n = 18) correcting for a sampling bias. Mean relative vertical profiles of HCHO and NO2 calculated with a global three-dimensional model (GEOS-CHEM) and used in the GOME retrieval are highly consistent with in situ measurements; differences would affect the retrieved NO2 and HCHO columns by a few percent. GOME HCHO columns over eastern Texas include contributions from anthropogenic volatile organic compound (VOC) emissions but are dominated by biogenic VOC emissions at the regional scale in August-September when HCHO columns are within 20% of those over the southeastern United States. In situ measurements show that during summer the lowest 1500 m (the lower mixed layer) contains 75% of the tropospheric NO2 column over Houston and Nashville, and 60% of the HCHO column over Houston. Future validation of space-based measurements of tropospheric NO2 and HCHO columns over polluted regions should include coincident in situ measurements that span the entire satellite footprint, especially in the heterogeneous mixed layer.

Martin, R. V.↗

The Sensitivity of U.S. Surface Ozone Formation to NOx, and VOCs as Viewed from Space

We investigated variations in the sensitivity of surface ozone formation in summer to precursor species concentrations of volatile organic compounds (VOCs) and nitrogen oxides (NO(x)) as inferred from the ratio of tropospheric columns of formaldehyde and nitrogen dioxide from the Aura Ozone Monitoring Instrument (OMI). The data indicate that ozone formation became: 1. more sensitive to NO(x) over most of the U.S, from 2005 to 2007 because of substantial decreases in NO(x) emissions primarily from stationary sources, and 2. more sensitive to NO(x) with increasing temperature, in part because emissions of highly reactive, biogenic isoprene increase with temperature, thus increasing the total VOC reactivity. Based on our interpretation of the data, current strategies implemented to reduce unhealthy levels of surface ozone should focus more on reducing NO(x) emissions, except in some downtown areas which have historically benefited from reductions in VOC emissions.

Duncan, Bryan N.↗

Carbon Nanotube Based Chemical Sensors for Space and Terrestrial Applications

A nanosensor technology has been developed using nanostructures, such as single walled carbon nanotubes (SWNTs), on a pair of interdigitated electrodes (IDE) processed with a silicon-based microfabrication and micromachining technique. The IDE fingers were fabricated using photolithography and thin film metallization techniques. Both in-situ growth of nanostructure materials and casting of the nanostructure dispersions were used to make chemical sensing devices. These sensors have been exposed to nitrogen dioxide, acetone, benzene, nitrotoluene, chlorine, and ammonia in the concentration range of ppm to ppb at room temperature. The electronic molecular sensing of carbon nanotubes in our sensor platform can be understood by intra- and inter-tube electron modulation in terms of charge transfer mechanisms. As a result of the charge transfer, the conductance of p-type or hole-richer SWNTs in air will change. Due to the large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors potentially can offer higher sensitivity, lower power consumption and better robustness than the state-of-the-art systems, which make them more attractive for defense and space applications. Combined with MEMS technology, light weight and compact size sensors can be made in wafer scale with low cost. Additionally, a wireless capability of such a sensor chip can be used for networked mobile and fixed-site detection and warning systems for military bases, facilities and battlefield areas.

Li, Jing↗

Enriched Storable Oxidizers for Rocket Engines

The name "enriched storable oxidizers" (ESOs) has been coined for a family of optimized mixtures of between two and four oxidizer fluids. For most applications, the constituents of these mixtures would be nitrogen tetroxide (N2O4), nitrous oxide (N2O), and nitrogen dioxide (NO2); in some applications, the mixtures might include inhibited red fuming nitric acid [IRFN (which consists of red fuming nitric acid to which some hydrogen fluoride is added to reduce its corrosive effect]. The optimum proportions of these constituents would be different for different applications. ESOs were originally proposed for use in spacecraft and launch-rocket propulsion systems: ESOs could be especially useful in advanced spacecraft propulsion systems that could operate in multiple modes. ESOs might also be useful in special terrestrial applications that could include ramjet and scramjet aircraft engines.

Sackheim, R. L.↗