Search NASA⌕ Search

SEARCH · Search NASA

Results for “OSIRIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Widely Distributed Exogenic Materials of Varying Compositions and Morphologies on Asteroid (101955) Bennu

Using the multiband imager MapCam on board the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer) spacecraft, we identified 77 instances of proposed exogenic materials distributed globally on the surface of the B-type asteroid (101955) Bennu. We identified materials as exogenic on the basis of an absorption near 1 μm that is indicative of anhydrous silicates. The exogenic materials are spatially resolved by the telescopic camera PolyCam. All such materials are brighter than their surroundings, and they are expressed in a variety of morphologies: homogeneous, breccia-like, inclusion-like, and others. Inclusion-like features are the most common. Visible spectrophotometry was obtained for 46 of the 77 locations from MapCam images. Principal component analysis indicates at least two trends: (i) mixing of Bennu's average spectrum with a strong 1-μm band absorption, possibly from pyroxene-rich material, and (ii) mixing with a weak 1-μm band absorption. The end member with a strong 1-μm feature is consistent with Howardite-Eucrite-Diogenite (HED) meteorites, whereas the one showing a weak 1-μm feature may be consistent with HEDs, ordinary chondrites, or carbonaceous chondrites. The variation in the few available near-infrared reflectance spectra strongly suggests varying compositions among the exogenic materials. Thus, Bennu might record the remnants of multiple impacts with different compositions to its parent body, which could have happened in the very early history of the Solar system. Moreover, at least one of the exogenic objects is compositionally different from the exogenic materials found on the similar asteroid (162173) Ryugu, and they suggest different impact tracks.

minor planets↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements.

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Organic Matter in Itokawa Particles

The first Hayabusa mission returned samples from the near-Earth S-type asteroid 25143 Itokawa to Earth in 2010[1]. Although Itokawa has a lithology related to ordinary chondrites(OCs) that typically have low organic contents, several Itokawa particles were found to contain organic matter (OM)[2-5]. However, there was not an explicit conclusion to the origin of the observed OMin these early studies. We have extended our search for OM into other Itokawa grains. Here, we report extraterrestrial OM (macromolecular carbon and amino acids) observed in six Itokawa particles(including a category1 particle: RA-QD02-0162[#62; also nicknamed “Amazon”],and five category3 carbon-rich particles:RA-QD02-0012[#12], RA-QD02-0078[#78], RB-CV-0029[#29], RB-CV-0080 [#80] and RB-QD04-0052[#52]).All allocated Itokawa samples were initially analysed by spot and point-by-point mapping Raman spectroscopic analysis at the Open University, UK. Amazon was then transferred and mounted into indium on an aluminium stub, which was studied with a NanoSIMS 50L ion microprobe for its H,C,N isotopic compositions. The rest of the samples were mounted in sterile gold foils, and the amino acid contents of their acid hydrolysed hot water extracts were obtained with a liquid chromatography with tandem fluorescence and accurate mass detection at NASA Goddard Space Flight Center, USA. Based on the observation of the Raman parameters(e.g. the peak locations and widths of the defect (D) and graphite (G) bands)[6], a significant variety of carbonaceous materials has been observed in Amazon. The carbonaceous materials include primitive and unaltered OM that shares similarity with the IOM in primitive (CI,CM,CR) carbonaceous chondrites, as well as OM that has been heavily graphitised. The organic structure of the heated material is best represented by nanocrystalline graphite, comparable to that observed for metamorphosed meteorites (e.g., L3–6 Inman, Tieschitz and New Concord,CV3 Allende, and EH4 Indarch),suggesting peak metamorphic temperatures (PMT) of >~600°C. The thermal history recorded in the graphitic OM agrees with PMT estimates for returned Itokawa regolith grains (600–800°C)[7].We have obtained the H,C,N isotopic compositions for the primitive OM in Amazon, which exhibits unambiguously extraterrestrial isotopic signatures (δD = +4868±2288‰; δ13C = −24±5‰; δ15N = +344±20‰), contrasting to the typically negative isotopic values obtained for terrestrial organic matter[8]. The δD and δ13C values of the organic material in Amazon are comparable to OCs, however, the δ15N value is higher than that typically observed for OCs (δ15N = −47 to +36‰), and is similar to that of CRs (δ15N = +153 to +309‰)[9].Our data suggest a genetic link between the primitive organic material observed in Itokawa to CRs and IDPs for they share similar D, 13C and 15N enrichments[10].The high carbon contents of the five category 3 Itokawa particles suggest potentially higher OM abundances, hence we extracted and analysed amino acids in these samples. Although terrestrial contamination was observed primarily as L-protein amino acids, several terrestrially uncommon non-protein amino acids were also observed at low abundances, such as β-aminoisobutyric acid (β-AIB),β-amino-n-butyric acid (β-ABA), and β-alanine. Itokawa amino acid content observed here was dissimilar to thermally altered OCs, but preliminarily analogous to more aqueously altered CR2s.Continued evolution of Itokawa is evident by the in fall of primitive organic material derived from CRs/IDPs, accounting for a complex interplay between the remnant Itokawa silicates with exogenous organics. The results reported here are the first evidence of extraterrestrial OM in asteroid material from a sample-return mission, showcasing a working protocol for analysing samples returned by the Hayabusa2 and OSIRIS-REx missions

Q. H. S. Chan↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Extraterrestrial Amino Acids in the C2 Ungrouped Carbonaceous Chondrite Tarda: A Unique Distribution

Introduction: Meteorites provide a record of the chemical processes that occurred in the early solar sys-tem. The delivery of organic matter by carbonaceous chondrites to the early Earth could have been an im-portant source of amino acids and other prebiotic or-ganic molecules required for the emergence of life [1]. To date, 96 amino acids have been named in meteor-ites, most of which are rare or absent in the biosphere [2]. The variability in amino acid concentrations and isomer distributions measured in carbonaceous chon-drites can be explained by differences in parent body chemistry and alteration conditions [3]. In addition, aqueous alteration was likely important in the amplifi-cation of some left-handed amino acids over their right-handed forms (L-excesses up to ~60%) in the Tagish Lake meteorite [3], suggesting that the origin of life on Earth and possibly elsewhere in the solar sys-tem was biased towards L-amino acids. On August 25, 2020, a fireball was witnessed in southern Morocco and the first pieces of the meteorite fall were recovered the following day near the town of Tarda [4]. Thousands of individual fragments were recovered from the strewn field totaling ~4 kg [4]. Based on petrographic observations, bulk mineralogy, and chemical and O-isotopic analyses, Tarda has been classified as a C2 ungrouped carbonaceous chondrite with similarities to Tagish Lake (though more primi-tive), as well as CI, CY, and CR chondrites [4,5]. The fall and rapid recovery of the Tarda stones provide an important opportunity to investigate a C-rich meteorite using the state-of-the-art techniques that will also be used to study the samples returned from asteroids Ryugu and Bennu by the Hayabusa2 and OSIRIS-REx missions, respectively. Here, we report the first amino acid analyses of the Tarda meteorite. The total concentrations, enantio-meric ratios and relative distributions of amino acids were determined using ultrahigh performance liquid chromatography with UV fluorescence and time-of-flight mass spectrometry (LC-FD/ToF-MS) at NASA GSFC. This analytical technique was employed on extracts from two different pre-rain Tarda meteorite fragments and a sample of sand collected from the Tarda fall site for the purpose of assessing potential terrestrial contamination. Bulk H, C, and N elemental and isotopic analyses were also conducted at the Car-negie Institution for Science (CIS) to assist with petro-logic type classification using elemental analysis iso-tope ratio mass spectrometry (EA-IRMS).

D P Glavin↗

Bennu Shape Model Validation Methods and Results

The OSIRIS-REx Independent Shape Modeling Team, staffed by the Jet Propulsion Laboratory (JPL), has used stereophotoclinometry (SPC) to produce a three-dimensional shape model of Bennu. The SPC process is informed by (but is separate from) orbit determination, so it is important to ensure that the resulting shape model is consistent with all available spacecraft tracking data. Specifically, checking the shape model’s consistency with LIDAR measurements can illuminate any discrepancies, because LIDAR measurements are highly correlated with the shape model. This study focuses on the JPL experience with these LIDAR measurements and the greater context of the shape model validation process.

Lauretta, Dante S.↗

Mars Sample Receiving Facility Research and Development to Enable Preservation, Safe Containment, and Scientific Research of Martian Samples on Earth

NASA and ESA are working together to plan a joint campaign to potentially bring back the first Martian samples to Earth in the early 2030s. On the surface of Mars, the Mars 2020Perseverance Rover is selecting and packaging samples that could be returned to Earth for careful examination by an international team of scientists. In preparation for this historic sample return, advance planning is underway to design and build a Mars Sample Receiving Facility (SRF) in the mid-2020s. In 2022, a Mars Sample Receiving Facility Assessment Study(MSAS) will be conducted to further define construction modality and capability options for a facility in the conterminous United States. Since Mars Sample Return (MSR) is currently categorized as a planetary protection restricted Earth return, this new facility would feature biosafety level 4 (BSL-4)-like high containment to protect Earth’s biosphere from any potential hazard. In addition, the facility also requires integration of cleanroom technologies to mitigate against terrestrial contamination and preserve sample integrity for science investigations. The integration of both clean handling and high containment requires significant technology research and development (R&D) by the mid-2020s to support the definition and planning of a SRF before commencing the site specific design phase. The SRF project will need to solidify the inorganic, organic, and biological contamination control (CC) requirements for the facility. This could entail a translation of Mars 2020 mission CC requirements for geologic material to engineering requirements for surfaces and airborne molecular contamination inside isolators and cleanrooms. In tandem, the project will need to determine precision cleaning and sterilization approaches for cleanrooms, isolators, equipment, and tools. Initial material selections for the facility construction materials, cleanrooms, isolators, and BSL-4 suits/garments are an important activity. The recent construction of the OSIRIS-REx and Hayabusa2 curation cleanroom laboratories greatly benefited from early materials testing, before the design phase, to reduced organic outgassing and particulate shedding inside the laboratory. While the early biohazard investigations in the SRF may deem the samples safe to release to laboratories throughout the world, sterilization methods need to be defined to safely release Martian samples. One key aspect of enabling simultaneous sample containment and cleanliness is the concept of a Double-Walled Isolator (DWI) that ESA has been pursuing. Further R&D is needed about DWIs, sample handling, and instrumentation interfaces before beginning the SRF site specific design phase. A working isolator/DWI engineering model should be developed and fabricated. Isolator sizes, connections, pass-through antechambers, and configurations and basic interfaces with instruments and tools as well as the use of robotic, mechanical, and/or human manipulation need to be considered. Inert high purity gas supply (one-pass or recirculation) and other isolator utilities must be determined. Special accommodations for large instruments (e.g., XCT,SEM, etc.) need to be developed. Techniques for opening the sample tubes packaged by M2020and extracting the headspace gas while keeping samples pristine will be challenging, requiring additional R&D, and engagement of the M2020 project. In addition, careful micromanipulation for subdivision and packaging of samples will also need to be included. These combined R&D activities are important before commencing the SRF design phase to ensure safe biohazard containment, sample preservation, and science integrity for the samples that would be studied in the SRF and in laboratories around the world.

mars sample return↗

Keck/OSIRIS Paβ High-contrast Imaging and Updated Constraints on PDS 70b

We present a high-contrast imaging search for Paβ line emission from protoplanets in the PDS 70 system with Keck/OSIRIS integral field spectroscopy. We applied the high-resolution spectral differential imaging technique to the OSIRIS J-band data but did not detect the Paβ line at the level predicted using the parameters of Hashimoto et al. (2020). This lack of Paβ emission suggests the MUSE-based study may have overestimated the line width of Hα. We compared our Paβ detection limits with the previous Hα flux and Hβ limits and estimated AV to be ∼0.9 and 2.0 for PDS 70 b and c, respectively. In particular, PDS 70 b’s AV is much smaller than implied by high-contrast near-infrared studies, which suggests the infrared-continuum photosphere and the hydrogen-emitting regions exist at different heights above the forming planet.

Taichi Uyama↗

Non-Protein Amino Acids Identified in Carbon-Rich Hayabusa Particles

Amino acid abundances in acid-hydrolyzed hot water extracts of gold foils containing five Category 3 (carbon-rich) Hayabusa particles were studied using liquid chromatography with tandem fluorescence and accurate mass detection. Initial particle analyses using field emission scanning electron microscopy with energy-dispersive X-ray spectrometry indicated that the particles were composed mainly of carbon. Prior to amino acid analysis, infrared and Raman microspectroscopy showed some grains possessed primitive organic carbon. Although trace terrestrial contamination, namely L-protein amino acids, was observed in all Hayabusa extracts, several terrestrially uncommon non-protein amino acids were also identified. Some Hayabusa particles contained racemic (D≈L) mixtures of the non-protein amino acids β-aminoisobutyric acid (β-AIB) and β-amino-n-butyric acid (β-ABA) at low abundances ranging from 0.09 to 0.31 nmol g −1 . Larger abundances of the non-protein amino acid β-alanine (9.2 nmol g −1 , ≈4.5 times greater than background levels) were measured in an extract of three Hayabusa particles. This β-alanine abundance was ≈6 times higher than that measured in an extract of a CM2 Murchison grain processed in parallel. The comparatively high β-alanine abundance is surprising as asteroid Itokawa is similar to amino acid-poor LL ordinary chondrites. Elevated β-alanine abundances and racemic β-AIB and β-ABA in Hayabusa grains suggested these compounds have non-biological and plausibly non-terrestrial origins. These results are the first evidence of plausibly extraterrestrial amino acids in asteroid material from a sample-return mission and demonstrate the capabilities of the analytical protocols used to study asteroid Ryugu and Bennu samples returned by the JAXA Hayabusa2 and NASA OSIRIS-REx missions, respectively.

Eric T. Parker↗

Qualification of Domestic Lyocell Based Phenolic Impregnated Carbon Ablator (PICA-D) for NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flag-ship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars Lander missions such as Mars Science Lab (MSL) and Mars 2020. The rayon-based carbon precursor raw material used in PICA preform manufacturing has experienced multiple supply chain issues. The challenge involved in finding a replacement fiber source is in processing as well as in the final performance of the ablator. Each replacement necessitates the requalification of the PICA. This has happened at least twice in the past 25 years, and a third substitution is now needed. Due to the obsolescence of the input foreign rayon fiber source, a new variant of PICA has been developed using a domestic rayon-like fiber source, Lyocell. Due to its flight heritage and proven capability, PICA is baselined as the Thermal Protection System (TPS) for Dragonfly and Mars Sample Return Sample Retrieval Lander mission and is being considered for the backshell of the Mars Sample Return Earth Entry System. All three missions are due to be launched between 2026 and 2028. The challenge this time is to ensure the PICA made with domestic material is a suitable replacement to the heritage PICA used in MSL and Mars 2020 so that the design of the heatshield can be matured without much risk. Results are presented from the recent efforts of 22 PICA-D billets that were Lot Acceptance Tested. Thermal, mechanical, and representative environment arc-jet tests have been conducted. Testing of PICA-Domestic (PICA-D) indicates very comparable performance with respect to “heritage” PICA materials and thus PICA-D is expected to be a sustainable and nearly a “drop-in” replacement solution for future NASA missions.

Matt Gasch↗

Qualification of Domestic Lyocell Based Phenolic Impregnated Carbon Ablator (PICA-D) for NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flag-ship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars Lander missions such as Mars Science Lab (MSL) and Mars 2020. The rayon-based carbon precursor raw material used in PICA preform manufacturing has experienced multiple supply chain issues. The challenge involved in finding a replacement fiber source is in processing as well as in the final performance of the ablator. Each replacement necessitates the requalification of the PICA. This has happened at least twice in the past 25 years, and a third substitution is now needed. Due to the obsolescence of the input foreign rayon fiber source, a new variant of PICA has been developed using a domestic rayon-like fiber source, Lyocell. Due to its flight heritage and proven capability, PICA is baselined as the Thermal Protection System (TPS) for Dragonfly and Mars Sample Return Sample Retrieval Lander mission and is being considered for the backshell of the Mars Sample Return Earth Entry System. All three missions are due to be launched between 2026 and 2028. The challenge this time is to ensure the PICA made with domestic material is a suitable replacement to the heritage PICA used in MSL and Mars 2020 so that the design of the heatshield can be matured without much risk. Results are presented from the recent efforts of 22 PICA-D billets that were Lot Acceptance Tested. Thermal, mechanical, and representative environment arc-jet tests have been conducted. Testing of PICA-Domestic (PICA-D) indicates very comparable performance with respect to “heritage” PICA materials and thus PICA-D is expected to be a sustainable and nearly a “drop-in” replacement solution for future NASA missions.

PICA↗

Effect of a Synchrotron X-ray Microtomography Imaging Experiment on the Amino Acid Content of a CM Chondrite

X-ray microcomputed tomography and synchrotron X-ray microcomputed tomography (μCT) are becoming popular tools for the reconnaissance imaging of chondrites. However, there are occasional concerns that the use of μCT may be detrimental to organic components of a chondrite. Soluble organic compounds represent ~2–10% of the total solvent extractable carbon in CI and CM carbonaceous chondrites and amino acids are among the most abundant compounds in the soluble organic fraction. We irradiated two samples of the Murchison CM2 carbonaceous chondrite under conditions slightly harsher (increased beam exposure time) than those typically used for x-ray μCT imaging experiments to determine if detectable changes in the amino acid abundance and distribution relative to a nonexposed control sample occurred. After subjecting two meteorite portions to ionizing radiation dosages of 1.1 kiloGray (kGy) and 1.2 kGy with 48.6 and 46.6 keV monochromatic X-rays, respectively, we analyzed the amino acid content of each sample. Within analytical errors, we found no differences in the amino acid abundances or enantiomeric ratios when comparing the control samples (nonexposed Murchison) and the irradiated samples. We show with calculations that any sample heating due to x-ray exposure is negligible. We conclude that a monochromatic synchrotron X-ray μCT experiment at beamline 13-BM-D of the Advanced Photon Source, which imparts ~1 kGy doses, has no detectable effect on the amino acid content of a carbonaceous chondrite. These results are important for the initial reconnaissance of returned samples from the OSIRIS-REx and Hayabusa 2 asteroid sample return missions.

Jon M. Friedrich↗

A Comparison of Stratospheric Smoke Events Seen by SAGE II (1984-2005) and SAGE III (2017-2021)

The ongoing Stratospheric Aerosol and Gas Experiment aboard the International Space Station (SAGE III/ISS) has mostly occurred during a period of relatively low aerosol loading. At the same time, it has almost observed a number of small to moderate injections of volcanic material in the stratosphere from the Aoba/Ambae eruption of 2018 to that of Karymsky in 2022. In addition, two of the largest known smoke intrusions into the stratosphere have occurred during the SAGE III/ISS mission (the British Columbia fire of August 2017 and the Australian Wildfire Event of 2019/2020). At least two other much smaller smoke events have also been observed in the SAGE III data (California Creek in September 2020 and McKay Creek in June 2021). Particularly with the two large events, it is tempting to speculate that these events are increasing in intensity and frequency possibly due to ongoing climate change. Realistically, change is difficult to assess since instrument data sets that can be used for quantifying historical events can be quite different in what and where they provide measurements. This complicates comparing one event to another potentially separated by many years. An exception to this issues are the measurements by SAGE III/ISS and those of its predecessor SAGE II (1984-2005). Both use the same measurement strategy, measure aerosol extinction coefficient at 1020 nm, and have similar spatial/temporal coverage. Both instruments are known to observe smoke events in the stratosphere. However, both have the same low observation density characteristic of solar occultation such that near-global coverage takes almost a month and characterizing effectively instant events like smoke and volcanic events take a matter of weeks depending on the vagaries of where the observations are being made at a critical juncture unlike instruments with high temporal/spatial resolution like limb-scatter instruments such as OMPS and OSIRIS. The goal of this work will be to use the same analysis approach to both the SAGE II and SAGE III data and compare both the frequency and intensity of smoke events observed by these instruments. While we do not expect to be able to make conclusions about change between the periods, the analysis is a first step in interpreting changes in the contribution of smoke to the stratospheric aerosol budget between the time frames encompassed by these instruments.

L. W. Thomason↗

Revisiting GloSSAC Using Space Based Measurements

We revisit Global Space-based stratospheric aerosol climatology (GloSSAC) and extend the dataset through 2021 in the latest version (version 2.2). Several space-based measurements have been used to construct GloSSAC. For version 2.2, important changes include implementation of a revised aerosol/cloud categorization for The Stratospheric Aerosol and Gas Experiment (SAGE III/ISS). SAGE III/ISS began its mission in June 2017. While SAGEIII/ISS makes reliable and robust solar occultation measurements in stratosphere—similar to its predecessors, interpreting aerosol extinction measurements in the vicinity of tropopause and in the troposphere have been a challenge for all SAGE measurements. Here, we study the challenges associated with the discrimination of aerosols and clouds from the extinction measurements. Here, we describe the methods implemented to categorize Clouds and aerosols using available SAGEIII/ISS aerosol measurements. We use version 5.2 of SAGE III/ISS extinction coefficients for the analysis. The current algorithm now classifies standard (background) and non-standard (enhanced) aerosols in the stratosphere and identify enhanced aerosols and aerosol/cloud mixture in the tropopause region. Extinction coefficient measurements from SAGE series of observations make an important contribution in the GloSSAC data base and therefore, the impact of cloud-filtered aerosol extinction coefficient measurements on the latest version of GloSSAC (version 2.2) is also discussed. Additionally, we discuss minor version changes occurred in other space-based measurements that include Optical Spectrograph and InfraRed Imaging System(OSIRIS) and Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation(CALIPSO). We also plan on evaluating and using aerosol extinction profiles from other satellite data sets such as Ozone Mapping Profiler Suite (OMPS) in a future version.

stratospheric aerosol↗

Development of Advanced Conformal and Soft Pica for Future Nasa Missions and Commercial Space

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flag-ship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars Lander missions such as MSL and Mars 2020. Continued development of a more mass efficient and compliant versions of PICA that use a carbon felt as the substrate will be presented. The felt based versions of PICA known as Conformal PICA (C-PICA) and Soft PICA (S-PICA), are very comparable in terms of peak heat-flux capabilities compared to standard PICA. The lower density and of C-PICA and S-PICA further show a much higher thermal protection efficiency and hence more mass savings. The compliant nature of these materials allows for use on a wide variety of substrates and therefore makes it very attractive for commercial low earth orbit missions as well as NASA’s aerocapture missions to Ice Giants. NASA is currently working with several commercial partners (Varda and Inversion Space) to Technology Transfer C/S-PICA variants for commercial LEO missions. Thermal, mechanical, and representative environment arc-jet tests have been conducted comparing the performance of Conformal and Soft-PICA materials.

Matthew J Gasch↗

Insights From Routine Microbiological Monitoring of Air in Astromaterials Curation Cleanrooms

NASA maintains nine separate cleanrooms at the Johnson Space Center to curate and preserve astromaterials samples. Routine microbial monitoring of the surfaces in these cleanrooms began in 20181. Until recently, materials compatibility requirements prevented monitoring airborne biological particles in all but one of these cleanrooms. New astromaterials collections from carbon rich asteroids are more susceptible to biological degradation than previous collections. Therefore, it is important to monitor the bioburden in the air and on surfaces in these labs. Establishing a comprehensive microbial monitoring program will help inform the monitoring and curation plans for Mars sample return which will include samples that are extremely biologically sensitive. In April of 2022 we began routinely collecting air samples in seven of the nine curation cleanrooms (Meteorite ISO 7 equivalent, Lunar ISO 6 equivalent, Stardust, Hayabusa2, OSIRIS-REx ISO 5 equivalent, and Genesis ISO 4 equivalent) using a sampling device that collects airborne biological particles on an electret filter instead conventional sampler that collect cells in a liquid media or onto organic rich Petri dishes. Electret is a generic term for electrostatically charged media. The charge on these materials increases particle trapping when compared to non-charged filters of similar thickness. N95 respirators also use electret filters. This dry sample collection method allows us to meet materials requirements for all the curation labs and reduces the risk of inadvertently introducing contamination as part of our monitoring effort. This method also allows us to preserve a portion of each sample for DNA extraction and next generation sequencing. DNA sequencing helps us to characterize the portion of the cleanroom microbiome that we cannot culture. We will present the results of our first 8 months of monitoring, compare these results to particle counts in the labs and to measurements made directly onto Petri dishes when possible. We will also make recommendations for modifications to the sampling method to improve sampling efficiency and preserve diversity.

A. B. Regberg↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

The Old, Unique C1 Chondrite Flensburg – Insight Into the First Processes of Aqueous Alteration, Brecciation, and the Diversity of Water-Bearing Parent Bodies and Lithologies

On September 12, 2019 at 12:49:48 (UT) a bolide was observed by hundreds of eye-witnesses from the Netherlands, Germany, Belgium, Denmark and the UK. One day later a small meteorite stone was found by accident in Flensburg. The presence of short-lived cosmogenic radionuclides with half-lives as short as 16 days proves the recent exposure of the found object to cosmic rays in space linking it clearly to the bolide event. An exceptionally short exposure time of ∼5000 years was determined. The 24.5 g stone has a fresh black fusion crust, a low density of <2 g/cm(exp 3), and a magnetic susceptibility of logχ = 4.35 (χ in 10−9 m(exp 3)/kg). The rock consists of relict chondrules and clusters of sulfide and magnetite grains set in a fine-grained matrix. The most abundant phases are phyllosilicates. Carbonates (∼3.9 vol.%) occur as calcites, dolomites, and a Na-rich phase. The relict chondrules (often surrounded by sulfide laths) are free of anhydrous silicates and contain abundant serpentine. Lithic clasts are also surrounded by similar sulfide laths partly intergrown with carbonates. Mn-53-Cr-53 ages of carbonates in Flensburg indicate that brecciation and contemporaneous formation of the pyrrhotite-carbonate intergrowths by hydrothermal activities occurred no later than 4564.6 ± 1.0 Ma (using the angrite D'Orbigny as the Mn-Cr age anchor). This corresponds to 2.6 ± 1.0 or 3.4 ± 1.0 Ma after formation of CAIs, depending on the exact absolute age of CAIs. This is the oldest dated evidence for brecciation and carbonate formation, which likely occurred during parent body growth and incipient heating due to decay of Al-26. In the three oxygen isotope diagram, Flensburg plots at the 16O-rich end of the CM chondrite field and in the transition field to CV-CK-CR chondrites. The mass-dependent Te isotopic composition of Flensburg is slightly different from mean CM chondrites and is most similar to those of the ungrouped C2 chondrite Tagish Lake. On the other hand, Ti-50 and Cr-54 isotope anomalies indicate that Flensburg is similar to CM chondrites, as do the ∼10 wt.% H2O of the bulk material. Yet, the bulk Zn, Cu, and Pb concentrations are about 30% lower than those of mean CM chondrites. The He, Ne, and Ar isotopes of Flensburg show no solar wind contribution; its trapped noble gas signature is similar to that of CMs with a slightly lower concentration of Ne(sub tr)-20. Based on the bulk H, C, and N elemental abundances and isotopic compositions, Flensburg is unique among chondrites, because it has the lightest bulk H and N isotopic compositions of any type 1 or 2 chondrite investigated so far. Moreover, the number of soluble organic compounds in Flensburg is even lower than that of the brecciated CI chondrite Orgueil. The extraordinary significance of Flensburg is evident from the observation that it represents the oldest chondrite sample in which the contemporaneous episodes of aqueous alteration and brecciation have been preserved. The characterization of a large variety of carbonaceous chondrites with different alteration histories is important for interpreting returned samples from the OSIRIS-REx and Hayabusa 2 missions.

C1 chondrite↗