Search NASA⌕ Search

SEARCH · Search NASA

Results for “Omega”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Use of d-{sup 3}He proton spectroscopy as a diagnostic of shell {rho}r in capsule implosion experiments with {approx}0.2 NIF scale high temperature Hohlraums at Omega

We present the calculations and preliminary results from experiments on the Omega laser facility using d-{sup 3}He filled plastic capsule implosions in gold Hohlraums. These experiments aim to develop a technique to measure shell {rho}r and capsule unablated mass with proton spectroscopy and will be applied to future National Ignition Facility (NIF) experiments with ignition scale capsules. The Omega Hohlraums are 1900 {mu}m lengthx1200 {mu}m diameter and have a 70% laser entrance hole. This is approximately a 0.2 NIF scale ignition Hohlraum and reaches temperatures of 265-275 eV similar to those during the peak of the NIF drive. These capsules can be used as a diagnostic of shell {rho}r, since the d-{sup 3}He gas fill produces 14.7 MeV protons in the implosion, which escape through the shell and produce a proton spectrum that depends on the integrated {rho}r of the remaining shell mass. The neutron yield, proton yield, and spectra change with capsule shell thickness as the unablated mass or remaining capsule {rho}r changes. Proton stopping models are used to infer shell unablated mass and shell {rho}r from the proton spectra measured with different filter thicknesses. The experiment is well modeled with respect to Hohlraum energetics, neutron yields, and x-ray imploded core image size, but there are discrepancies between the observed and simulated proton spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hard x-ray transmission crystal spectrometer at the OMEGA-EP laser facility

The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional simulations of the neutron yield in cryogenic deuterium-tritium implosions on OMEGA

Maximizing the neutron yield to obtain energy gain is the ultimate goal for inertial confinement fusion. Nonuniformities seeded by target and laser perturbations can disrupt neutron production via the Rayleigh-Taylor instability growth. To understand the effects of perturbations on the neutron yield of cryogenic DT implosions on the Omega Laser Facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], two-dimensional DRACO[P. B. Radha et al., Phys. Plasmas 12, 056307 (2005)] simulations have been performed to systematically investigate each perturbation source and their combined effects on the neutron-yield performance. Two sources of nonuniformity accounted for the neutron-yield reduction in DRACO simulations: target offset from the target chamber center and laser imprinting. The integrated simulations for individual shots reproduce the experimental yield-over-clean (YOC) ratio within a factor of 2 or better. The simulated neutron-averaged ion temperatures <T{sub i}> is only about 10%-15% higher than measurements. By defining the temperature-over-clean, its relationship to YOC provides an indication of how much the hot-spot volume and density are perturbed with respect to the uniform situation. Typically, the YOC in OMEGA experiments is of the order of {approx}5%. The simulation results suggest that YOC can be increased to the ignition hydroequivalent level of 15%-20% (with <{rho}R>=200-300 mg/cm{sup 2}) by maintaining a target offset of less than 10 {mu}m and employing beam smoothing by spectral dispersion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absorption of the omega and phi mesons in nuclei

The properties of hadrons, such as their masses and widths, are predicted to be modified in dense and/or hot nuclear matter. Particular attention has been given to the modifications of vector-meson properties in ordinary nuclear matter where chiral symmetry is predicted to be partially restored due to a change in the quark condensate. Different models predict relatively large measurable changes in the mass and/or the width of these mesons. The e{sup +}e{sup -} decay channel of these mesons has negligible final-state interactions (FSI), providing an ideal tool to study their possible in-medium modifications Due to its short lifetime, the {rho} meson has a substantial probability of decaying in the nucleus and its study has been previously reported. Due to their long lifetimes, the {omega} and {phi} mesons are ideal candidates for the study of possible modifications of the in-medium meson-nucleon interaction through their absorption inside the nucleus. These mesons have been photo-produced in several targets ranging from deuterium to lead. Nuclear transparencies ratios have been derived for different decay channels. These ratios indicate larger in-medium widths compared with what have been reported in other reaction channels. The absorption of the {omega} meson is stronger than that reported by the CBELSATAPS experiment. These results are compared to recent theoretical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-dimensional modeling of direct-drive cryogenic implosions on OMEGA

The effects of large-scale (with Legendre modes ≲10) laser-imposed nonuniformities in direct-drive cryogenic implosions on the OMEGA laser system are investigated using three-dimension hydrodynamic simulations performed using a newly developed code ASTER. Sources of these nonuniformities include an illumination pattern produced by 60 OMEGA laser beams, capsule offsets (~10 to 20 μm), and imperfect pointing, energy balance, and timing of the beams (with typical σ rms ~10 μm, 10%, and 5 ps, respectively). Two implosion designs using 26-kJ triple-picket laser pulses were studied: a nominal design, in which a 880-μm-diameter capsule is illuminated by the same-diameter beams, and a “R75” design using a capsule of 900 μm in diameter and beams of 75% of this diameter. Simulations found that nonuniformities because of capsule offsets and beam imbalance have the largest effect on implosion performance. These nonuniformities lead to significant distortions of implosion cores resulting in an incomplete stagnation. The shape of distorted cores is well represented by neutron images, but loosely in x-rays. Simulated neutron spectra from perturbed implosions show large directional variations and up to ~ 2 keV variation of the hot spot temperature inferred from these spectra. The R75 design is more hydrodynamically efficient because of mitigation of crossed-beam energy transfer, but also suffers more from the nonuniformities. Furthermore, simulations predict a performance advantage of this design over the nominal design when the target offset and beam imbalance σ rms are reduced to less than 5 μm and 5%, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility

The particle-time-of-flight (pTOF) detector at the National Ignition Facility (NIF) is used routinely to measure nuclear bang-times in inertial confinement fusion implosions. The active detector medium in pTOF is a chemical vapor deposition diamond. Calibration of the detectors sensitivity to neutrons and protons would allow measurement of nuclear bang times and hot spot areal density (ρR) on a single diagnostic. This study utilizes data collected at both NIF and Omega in an attempt to determine pTOF’s absolute sensitivity to neutrons. At Omega pTOF’s sensitivity to DT-n is found to be stable to within 8% at different bias voltages. At the NIF pTOF’s sensitivity to DD-n varies by up to 59%. This variability must be decreased substantially for pTOF to function as a neutron yield detector at the NIF. As a result, some possible causes of this variability are ruled out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high-resolving-power x-ray spectrometer for the OMEGA EP Laser (invited)

A high-resolving-power x-ray spectrometer has been developed for the OMEGA EP Laser System based on a spherically bent Si [220] crystal with a radius of curvature of 330 mm and a Spectral Instruments (SI) 800 Series charge-coupled device. The instrument measures time-integrated x-ray emission spectra in the 7.97- to 8.11-keV range, centered on the Cu K{sub α1} line. To demonstrate the performance of the spectrometer under high-power conditions, K{sub α1,2} emission spectra were measured from Cu foils irradiated by the OMEGA EP laser with 100-J, 1-ps pulses at focused intensities above 10{sup 18} W/cm{sup 2}. The ultimate goal is to couple the spectrometer to a picosecond x-ray streak camera and measure temperature-equilibration dynamics inside rapidly heated materials. The plan for these ultrafast streaked x-ray spectroscopy studies is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the effects of laser imprint on plastic-target implosions on OMEGA

Understanding the effects of laser imprint on target performance is critical to the success of direct-drive inertial confinement fusion. Directly measuring the disruption caused by laser imprints to the imploding shell and hot-spot formation, in comparison with multidimensional radiation–hydrodynamic simulations, can provide a clear picture of how laser nonuniformities cause target performance to degrade. With the recently developed x-ray self-emission imaging technique and the state-of-the-art physics models recently implemented in the two-dimensional hydrocode DRACO , a systematic study of laser-imprint effects on warm target implosions on OMEGA has been performed using both experimental results and simulations. By varying the laser-picket intensity, the imploding shells were set at different adiabats (from α = 2 to α = 6). As the shell adiabats decreased, it was observed that (1) the measured shell thickness at the time the hot spot lit up became larger than the uniform one-dimensional (1-D) predictions; (2) the hot-spot core emitted earlier than the corresponding 1-D predictions; (3) the measured neutron yield first increased then decreased as the shell adiabat α was reduced; and (4) the hot-spot size reduced as α decreased for cases where SSD (smoothing by spectral dispersion) was on but became larger for low-α shots in cases where SSD was off. Most of these experimental observations are well reproduced by DRACO simulations with laser imprints including modes up to λ max = 200. In addition, these studies identify the importance of laser imprint as the major source of degrading target performance for OMEGA implosions of adiabat α ≤ 3. Mitigating laser imprints is required to improve low-α target performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional hydrodynamic simulations of OMEGA implosions

Here, the effects of large-scale (with Legendre modes ≲10) asymmetries in OMEGA direct-drive implosions caused by laser illumination nonuniformities (beam-power imbalance and beam mispointing and mistiming), target offset, and variation in target-layer thickness were investigated using the low-noise, three-dimensional Eulerian hydrodynamic code ASTER. Simulations indicate that these asymmetries can significantly degrade the implosion performance. The most important sources of the asymmetries are the target offsets (~10 to 20 μm), beam-power imbalance (σ rms ~ 10%), and variations (~5%) in target-layer thickness. Large-scale asymmetries distort implosion cores, resulting in a reduced hot-spot confinement and an increased residual kinetic energy of implosion targets. The ion temperature inferred from the width of simulated neutron spectra is influenced by bulk fuel motion in the distorted hot spot and can result in up to an ~1 -keV increase in apparent temperature. Similar temperature variations along different lines of sight are observed. Demonstrating hydrodynamic equivalence to ignition designs on OMEGA requires a reduction in large-scale target and laser-imposed nonuniformities, minimizing target offset, and employing highly efficient mid-adiabat (α = 4) implosion designs, which mitigate cross-beam energy transfer and suppress short-wavelength Rayleigh–Taylor growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of cryogenic target position and implosion core offsets on OMEGA

Cryogenic target implosions currently performed on the University of Rochester’s OMEGA Laser System are of DT-filled polystyrene shells held at near the triple point temperature (~20 K) inside a cooled shroud that must be retracted from around the target just before the target is illuminated by OMEGA. As a consequence, impulses may be imparted to the target stalk, causing the target to depart from its ideal position centered at the aim point of the laser beams. The positions of cryogenic targets at the start of the laser pulse are determined in this work by comparing the positions of images of the cryogenic target implosion to that of a non-cryogenic target implosion that is accurately centered on the aim point of the beams. Images are from an array of up to five digitally recorded, x-ray pinhole cameras. Positions of the resultant implosion cores are determined along a single line of sight from x-ray images of these cores taken with an x-ray microscope operating in time-integrated mode. The offsets of the cryogenic-target cores relative to the non-cryogenic-target cores are found to have a magnitude and direction consistent with the core forming in the direction of the target offset at the start of the laser pulse. Here, the inferred offsets are therefore consistent to each other within errors. Neutron yields are seen to be affected by target offset although with considerable scatter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of apparent ion temperature using the magnetic recoil spectrometer at the OMEGA laser facility

The Magnetic Recoil neutron Spectrometer (MRS) at the OMEGA laser facility has been routinely used to measure deuterium-tritium (DT) yield and areal density in cryogenically layered implosions since 2008. Recently, operation of the OMEGA MRS in higher-resolution mode with a new smaller, thinner (4 cm 2 , 57 μm thick) CD 2 conversion foil has also enabled inference of the apparent DT ion temperature (T ion ) from MRS data. MRS-inferred T ion compares well with T ion as measured using neutron time-of-flight spectrometers, which is important as it demonstrates good understanding of the very different systematics associated with the two independent measurements. The MRS resolution in this configuration, $ΔE_{MRS}$ = 0.91 MeV FWHM, is still higher than that required for a high-precision T ion measurement. We show herein how fielding a smaller foil closer to the target chamber center and redesigning the MRS detector array could bring the resolution to $ΔE_{MRS}$ = 0.45 MeV, reducing the systematic T ion uncertainty by more than a factor of 4.

47 OTHER INSTRUMENTATION↗

The single-line-of-sight, time-resolved x-ray imager diagnostic on OMEGA

We present that the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI) on OMEGA is one of a new generation of fast-gated x-ray cameras comprising an electron pulse-dilation imager and a nanosecond-gated, burst-mode, hybrid complementary metal-oxide semiconductor sensor. SLOS-TRXI images the core of imploded cryogenic deuterium–tritium shells in inertial confinement fusion experiments in the ~4- to 9-keV photon energy range with a pinhole imager onto a photocathode. The diagnostic is mounted on a fixed port almost perpendicular to a 16 channel, framing-camera–based, time-resolved Kirkpatrick–Baez microscope, providing a second time-gated line of sight for hot-spot imaging on OMEGA. SLOS-TRXI achieves ~40-ps temporal resolution and better than 10 μm spatial resolution. Finally, shots with neutron yields of up to 1 × 10 14 were taken without observed neutron-induced background signal. The implosion images from SLOS-TRXI show the evolution of the stagnating core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a neutron time-of-flight detector with a rapid instrument response function for measurements of bulk fluid motion on OMEGA

A newly developed neutron time-of-flight (nTOF) diagnostic with a fast instrument response function has been fielded on the OMEGA laser in a highly collimated line of sight. In this study, by using a small plastic scintillator volume, the detector provides a narrow instrument response of 1.7 ns full width at half maximum while maintaining a large signal-to-noise ratio for neutron yields between 10 10 and 10 14 . The OMEGA hardware timing system is used along with an optical fiducial to provide an absolute nTOF measurement to an accuracy of ~56 ps. The fast instrument response enables the accurate measurement of the primary deuterium-tritium neutron peak shape, while the optical fiducial allows for an absolute neutron energy measurement. The new detector measures the neutron mean energy with an uncertainty of ~7 keV, corresponding to a hot-spot velocity projection uncertainty of ~12 km/s. Finally, evidence of bulk fluid motion in cryogenic targets is presented with measurements of the neutron energy spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpreting the electron temperature inferred from x-ray continuum emission for direct-drive inertial confinement fusion implosions on OMEGA

In this paper, we present a theoretical framework for interpreting the hot-spot electron temperature ($T_e$) inferred from hard (10- to 20-keV) x-ray continuum emission for inertial confinement fusion implosions on OMEGA. We first show that the inferred $T_e$ represents the emission-weighted, harmonic mean of the hot-spot $T_e$ distribution, both spatially and temporally. A scheme is then provided for selecting a photon energy of which the emission weighting approximates neutron weighting. Simulations are then used to quantify the predicted relationship between the inferred T e , neutron-weighted T i , and implosion performance on OMEGA. In an ensemble of 1-D simulations, it was observed that hot-spot thermal nonequilibrium precluded a sufficiently unique mapping between the inferred $T_e$ and neutron-weighted T i . In 3-D simulations with low-harmonic-mode perturbations (i.e., laser beam power imbalance, target offset, and beam port geometry departures from spherical symmetry) and laser imprint (1 max = 200).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydro-scaling of direct-drive cylindrical implosions at the OMEGA and the National Ignition Facility

Deceleration-phase Rayleigh–Taylor instability (RTI) growth during inertial confinement fusion capsule implosions significantly affects the performance as it mixes cold ablator material into the fuel. Precise measurements of such instability growth are essential for both validating the existing simulation codes and improving our predictive capability. RTI measurements on the inner surface of a spherical shell are limited and are often inferred indirectly at limited convergence. In contrast, cylindrical implosions allow for direct diagnostic access to the converging interface by imaging down the cylinder axis while retaining the effects of convergence. We have performed direct-drive cylindrical implosion experiments at both the OMEGA and the NIF laser facilities using scaled targets. RTI growth is demonstrated to be scale-invariant between the cylindrical targets at OMEGA and similar targets at the NIF, which are scaled up by a factor of three in the radial dimension. Single-mode (m = 0) instability growth factors of ~14 are measured at a convergence ratio (CR) ~ 2.5 with nearly identical mode growth at both scales. The measurements are in agreement with xRAGE radiation-hydrodynamics simulations. In addition, we have developed the Bayesian-inference-engine method to account for the variations in the target alignment, magnification, and the parallax effect in the measurement, allowing a more precise comparison between the experimental data and the simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-radiography of imploded shells on OMEGA based on additive-free multi-monochromatic continuum spectral analysis

Radiographs of pure-DT cryogenic imploding shells provide critical validation of progress toward ignition-scalable performance of inertial confinement fusion implosions. Cryogenic implosions on the OMEGA Laser System can be self-radiographed by their own core spectral emission near ≈2 keV. Utilizing the distinct spectral dependences of continuum emissivity and opacity, the projected optical-thickness distribution of imploded shells, i.e., the shell radiograph, can be distinguished from the structure of the core emission distribution in images.Importantly, this can be done without relying on spectral additives (shell dopants), as in previous applications of implosion self-radiography. Furthermore, demonstrations with simulated data show that this technique is remarkably well-suited to cryogenic implosions and can also be applied to self-radiography of imploded room-temperature CH shells at higher spectral energy (hv ≈ 3–5 keV) based on the very similar continuum spectrum of carbon. Experimental demonstration of additive-free self-radiography with warm CH shell implosions on OMEGA will provide an important proof of principle for future applications to cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unabsorbed light beamlets for diagnosing coronal density profiles and absorption nonuniformity in direct-drive implosions on OMEGA

Laser light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. The 3ωGOI (gated optical imager) beamlets diagnostic images unabsorbed light from all 60 OMEGA beams as distinct “beamlet” spots for each beam. The implosion can be diagnosed using the position and intensity of these beamlets. The position of each beamlet in the image is determined by refraction and can be used to fit the coronal plasma density profile of the implosion. The inferred plasma density profiles are comparable to profiles predicted by the 1-D hydrodynamics code LILAC but suggest the predictions underestimate the density farther out in the corona. The intensity of light in each spot depends on the cumulative effects of absorption and cross-beam energy transfer along the beamlet’s path through the corona. Furthermore, the measured variation in intensity and polarization between similar spots indicates that absorption during OMEGA implosions is less uniform than previously known.

47 OTHER INSTRUMENTATION↗

Demonstration of plasma mirror capability for the OMEGA Extended Performance laser system

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 μm thick Cu foil, generating Bremsstrahlung and k α x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm –2 , and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 10 18 W cm –2 , which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗