Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Damage tolerance in the graphite cores of UK power reactors and implications for new build

The United Kingdom has been operating graphite-moderated gas-cooled commercial nuclear power reactors for more than 60 years. Both Generation I Magnox reactors and Generation II Advanced Gas-cooled Reactors have operated beyond their nominal design lifetimes and the safety cases for continued operation have had to address the issue of damage tolerance of the graphite cores. This review describes the designs of the reactors and the methodologies employed for their assessment. Emerging issues arising from extended operation and ageing of the cores are discussed together with the evolution of assessment methodologies to address predicted and observed damage. The UK nuclear regulator perspective is summarised and some conclusions are drawn on the implications for new build.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Making the Most Out of an Indoor Environmental Quality Assessment

This document is for federal agencies, building owners, and building managers and operators who are considering conducting indoor environmental quality (IEQ)assessments at their facilities. The following information explains what value IEQ assessments can provide and how to plan for one.

Ackerman, Allison↗

Direct quantification of ion composition and mobility in organic mixed ionic-electronic conductors

Ion transport in organic mixed ionic-electronic conductors (OMIECs) is crucial due to its direct impact on device response time and operating mechanisms but is often assessed indirectly or necessitates extra assumptions. Operando x-ray fluorescence (XRF) is a powerful, direct probe for elemental characterization of bulk OMIECs and was used to directly quantify ion composition and mobility in a model OMIEC, poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) (PEDOT:PSS), during device operation. The first cycle revealed slow electrowetting and cation-proton exchange. Subsequent cycles showed rapid response with minor cation fluctuation (~5%). Comparison with optical-tracked electrochromic fronts revealed mesoscale structure–dependent proton transport. The calculated effective ion mobility demonstrated thickness-dependent behavior, emphasizing an interfacial ion transport pathway with a higher mobile ion density. The decoupling of interfacial effects on bulk ion mobility and the decoupling of cation and proton migration elucidate ion transport in conventional and emerging OMIEC-based devices and has broader implications for other ionic conductors writ large.

42 ENGINEERING↗

Techno-Economic Analysis of Large-Scale Hydrogen Production from Solid Oxide Electrolysis Cell Systems

The objective of this study is to establish a detailed techno-economic analysis to assess the effectiveness of incremental technology improvements needed for solid oxide electrolysis cell (SOEC) technology to achieve the U.S. DOE’s Hydrogen Shot goal of hydrogen production at less than $1 per kilogram. The pathway considers incremental technology improvements to key system parameters, with system performance and cost assessed for each pathway step. Briefly, the steps include cell voltage degradation rate improvements, operational current density increases, operating temperature reduction, improved steam utilization, increased system capacity factor, and reduced cell/stack capital costs. Each step is assessed at both atmospheric and pressurized (8 bar) operating conditions. To supplement assessment at each of these discrete stepwise improvements, sensitivity studies are conducted to understand the relative impact of each parameter and identify avenues for additional cost reductions. System efficiency and levelized costs of hydrogen (LCOH) for each case are presented. For the end-of-pathway case, which includes all the incremental research and development improvements, the cost of hydrogen produced is reduced by 50 percent from the state-of-the-art case.

08 HYDROGEN↗

Demonstration of MELCOR and MACCS Capabilities for Molten Salt Reactor Decay Heat Removal During both Normal Operations and Salt Spill Scenarios

This report provides a demonstration of MELCOR and MELCOR Accident Consequence Code System (MACCS) capabilities to perform a dose assessment for a Molten Salt Reactor (MSR) off-gas system. A primary containment system salt spill is used as the off-normal scenario, along with a normal operation dose assessment for comparison. This report discusses the tools, methods, and information used in this assessment so that it may be utilized as a starting point for future advanced reactor consequence analyses. This report also highlights several gaps, to include the need for reactor inventory information specific to advanced reactors, and the need for specific atmospheric transport models that take into account the unique deposition behaviors of tritium and carbon-14, and makes recommendations for closing these gaps. This report satisfies the DOE NE Milestone M4RD-21SN0601062.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A comprehensive framework to assess elemental mercury in the Department of Energy: A time series analysis

Objective: This study investigated whether seasonal categories affect airborne mercury concentrations in the U.S. Department of Energy operations. Methods: We conducted an initial assessment of the general variability of airborne elemental mercury time-weighted average (TWA) samples. Then, we performed a two-component time series analysis to determine whether long-term, cyclical temperature change patterns affect mercury concentrations. Results: Both ARIMA time series models demonstrated stationary, non-random means (χ² = 83.8, p < 0.001) and standard deviation (χ² = 55.8, p < 0.001) of mercury concentrations. Here, our results indicate that the seasonal factors did not influence mercury concentration. Conclusions: Our results demonstrate that mercury concentrations primarily emanate from operational activities, work practices, and/or transient environmental conditions rather than seasonal fluctuations.

Cannady, Ryan T. [Oak Ridge National Laboratory (O↗

Proposed Critical Thinking Metrics for Power Grid Trainees

The TRS Intro to Critical Thinking for Operational Decision-Making course for power grid operators seeks to help trainees improve their use of critical thinking skills in operation environments. To determine the effectiveness of this training, we have identified 3 categories of evaluation measures: critical thinking metrics, situation awareness (SA) evaluations, and behavioral observations. Critical thinking metrics seek to directly measure trainee’s ability to use critical thinking skills through their verbalized responses to different questions or scenarios. SA will be evaluated during various points throughout simulated exercises completed during the training. SA evaluations aim to determine the level of a trainee’s ability to perceive, comprehend and anticipate events in the operational environment. This construct will be assessed through verbalized responses to questions informed by the Situation Awareness Global Assessment Technique (SAGAT). Behavioral observations capture how trainees use the system, including which simulator displays or windows they use or actions they perform and in what order. These observations help us understand how the critical thinking training may inform operator action. We hypothesize that while these measures are correlated with each other, they provide different perspectives on each trainee’s ability to gain SA and use critical thinking skills in operation environments. By comparing these measures in a pre-assessment and a post-assessment, we can determine how much improvement a trainee gains through the training. These measures may also be used during the training as appropriate. This document specifies these 3 categories of measures, which components of these measures currently seem to be the best candidates to use in the training course, and which parts of the training course is related to each component.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Assessment of Alternate Chlorination Process

Recent advancements towards low-temperature chlorination with disulfur dichloride and thionyl chloride of Al-clad used nuclear fuel (UNF) have been summarized for work control technical expertise development at the Savannah River National Laboratory (SRNL). This technique aims to provide a more effective method for separating U from cladding or alloying elements. A preliminary assessment determined needs for unit operation developments in regard to reaction kinetics and reagent quality. Furthermore, an analysis of an Uruguay fuel plate (U-Al x fuel meat), with low-enriched uranium (LEU) and located at SRNL, was a potential candidate for future experiments with lightly irradiated (0.08% burnup) fuel to test for chlorination. Future proposed work would involve kinetic studies, reagent quality assessments, and the machining of the fuel plate down to an appropriate bench-scale size and testing the effectiveness of low-temperature chlorination on the fuel plate.

Chlorination↗

Modeling and Analysis of DC Microgrids as Stochastic Hybrid Systems

This study proposes a method of predicting the influence of random load behavior on the dynamics of dc microgrids and distribution systems. This is accomplished by combining stochastic load models and deterministic microgrid models. Together, these elements constitute a stochastic hybrid system. The resulting model enables straightforward calculation of dynamic state moments, which are used to assess the probability of desirable operating conditions. Specific consideration is given to systems based on the dual active bridge (DAB) topology. Bounds are derived for the probability of zero voltage switching (ZVS) in DAB converters. A simple example is presented to demonstrate how these bounds may be used to improve ZVS performance as an optimization problem. In conclusion, predictions of state moment dynamics and ZVS probability assessments are verified through comparisons to Monte Carlo simulations.

42 ENGINEERING↗

Special Analyses for the Hanford Integrated Disposal Facility Performance Assessment - 20102

In 2014, the Department of Energy (DOE) Office of River Protection and its contractors began to develop a performance assessment for the near-surface disposal of low-level and mixed low-level waste at the Hanford Site's Integrated Disposal Facility (IDF). The IDF is a doubly-lined landfill that was constructed between 2004 and 2006 to be the disposal facility for the vitrified low-activity waste that will be produced at the Waste Treatment and Immobilization Plant (WTP). IDF is also expected to receive solid secondary waste produced at the WTP and other solid wastes from site activities. The IDF has been in a preoperational state awaiting authorization from DOE and a RCRA permit modification from the State of Washington Department of Ecology to receive waste. Both the Disposal Authorization Statement and permit modification require a performance assessment demonstrating that the system of engineered and natural features will limit releases of radionuclides and hazardous chemicals from the IDF and be protective of human health and the environment. The simulated duration is 10,000 years. Based on the analyses presented in the 2017 Integrated Disposal Facility Performance Assessment, DOE issued a conditional Operating Disposal Authorization Statement for the IDF in June 2018. The long-term performance of the IDF to be protective of human health and the environment was evaluated under the requirements of DOE Order 435.1, Radioactive Waste Management. Computer simulations were performed to evaluate whether or not the IDF would comply with DOE requirements. In the time that has passed since the performance assessment was approved by DOE, new information has been discovered that had not been considered in the performance assessment. Since this new information has not been evaluated, the potential impact of the changes have not been taken into consideration in DoE's disposal authorization. DOE and its contractors follow a change control process to screen and, when necessary, evaluate new information that could potentially impact the conclusions of the completed performance assessment. This paper will describe the change control process and provide two examples of evaluations performed following the change control process. The first example evaluates a new waste form for liquid secondary waste that was not evaluated in the performance assessment. In the performance assessment, liquid secondary waste was assumed to be solidified with grout. A new recommendation to dispose of the liquid secondary waste after drying it to a powder was evaluated. The second example evaluates inventory implications from changes to the flow sheet that estimates the feed composition to the low-activity waste vitrification facility. The changes result in higher strontium concentrations in the vitrified waste stream. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Operational Modes of a 2.0 MWth Chloride Molten-Salt Pilot-Scale System

The limit of traditional solar-salt thermal stability is around 600 °C with ambient air as the cover gas. Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered to be state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. However, decomposition challenges occur with these salts for operation beyond 600 C. Although slightly higher limits may be possible with solar salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, molten-salt technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative salt chemistry composition, such as chlorides. In this investigation a 2.0MWth Pilot-scale CSP plant design is developed to assess thermodynamic performance potential for operation up to 720 C. Here, an Engineering Equation Solver (EES) model is developed with respect to 14 state-points from the base of a solar tower at the Sandia National Laboratories, National Solar Thermal Test Facility (NSTTF), to solar receiver mounted 120 ft. above the ground. The system design considers a ternary chloride ternary chloride (20%NaCl/40%MgCl/40%KCl by mol%) salt as the HTF, with 6 hrs. of storage and a 1 MWth primary salt to sCO2 heat exchanger. Preliminary system modelling results indicate a minimum non-dimensional Cv of 60 required for both cold and hot-side throttle recirculation valves for the operational pump operating between speeds of 1800 and 2400 RPM. Further receiver comparison study results suggest that the ternary salt requires an average 15.2% higher receiver flux with a slightly lower calculated receiver efficiency when compared to a binary carnelite salt to achieve a 2.0 MWth desired input power design.

associated liquids↗

High-Resolution South American Wind Resource Data Downscaled with Generative Machine Learning Conditioned on Near-Surface Observations

High-resolution historical wind data was developed for the entirety of South America using the innovative Super-Resolution for Renewable Resource Data (sup3r) machine learning framework. The publicly available Sup3rWind South America dataset represents a significant advancement in wind resource data generation, leveraging generative machine learning conditioned on near-surface observations from the Meteorological Assimilation Data Ingest System (MADIS) to efficiently and accurately downscale coarse reanalysis data from the European Centre for Medium-Range Weather Forecasts (ERA5). This approach produces fine-scale, spatially and temporally coherent wind and meteorological fields hundreds of times more computationally efficient than traditional numerical weather modeling methods, enabling access to high-fidelity wind information across both continental and offshore regions. Sup3rWind South America builds on the earlier Sup3rWind Ukraine dataset through improvements in model architecture and outputs conditioned on near-surface observation inputs. As with the Ukraine data release, this dataset includes wind speed, wind direction, temperature, relative humidity, and pressure at a horizontal resolution of ~2 km, representing a 15x spatial enhancement relative to the 31 km ERA5 grid. Wind speed and direction are provided at 5-minute resolution, a 12x temporal refinement compared to the hourly ERA5 data, while temperature, relative humidity, and pressure remain at hourly resolution. The data covers all years from 2005 to 2024. Before downscaling, ERA5 inputs were bias-corrected using long-term monthly means and a limited number of quality-controlled observations to align large-scale statistics with regional conditions. The resulting dataset is the first publicly available high-resolution timeseries wind record that provides full spatial coverage of South America. Model validation demonstrates strong agreement with observations across several statistical metrics, consistent with other state-of-the-art high-resolution wind resource datasets. The potential applications of Sup3rWind South America span renewable energy resource assessment, energy system modeling, and grid resilience analysis. The 20-year record and high spatial and temporal resolution support accurate estimation of long-term energy yield and the economic feasibility of potential wind development sites. Continuous coverage across both continental and offshore regions enables comprehensive site prospecting within exclusive economic zones. The 2 km, 5-minute resolution data provide the spatial and temporal variability required for power system simulation, operational planning, and regional risk assessments.

17 WIND ENERGY↗

Energy and Environmental Analyses of a Solar–Gas Turbine Combined Cycle with Inlet Air Cooling

Sensitivity to ambient air temperatures, consuming a large amount of fuel, and wasting a significant amount of heat dumped into the ambient atmosphere are three major challenges facing gas turbine power plants. This study was conducted to simultaneously solve all three aforementioned GT problems using solar energy and introducing a new configuration that consists of solar preheating and inlet-air-cooling systems. In this study, air was preheated at a combustion chamber inlet using parabolic trough collectors. Then, inlet air to the compressor was cooled by these collectors by operating an absorption cooling cycle. At the design point conditions, this novel proposed integration resulted in a 6.87% relative increase in generated power and a 10.53% relative decrement in fuel consumption, achieving a 19.45% relative increment in the plant’s thermal efficiency. This was accompanied by a reduction of 0.026 kg/s, 4.2 kg/s, and 0.278 kg/s in CO 2 , CO, and NOx emissions, respectively. Finally, spider diagrams were employed to assess the impact of the operating parameters on the overall system’s performance and its associated environmental implications.

14 SOLAR ENERGY↗

Impacts of climate change on subannual hydropower generation: a multi-model assessment of the United States federal hydropower plant

Abstract Hydropower is a low-carbon emission renewable energy source that provides competitive and flexible electricity generation and is essential to the evolving power grid in the context of decarbonization. Assessing hydropower availability in a changing climate is technically challenging because there is a lack of consensus in the modeling representation of key dynamics across scales and processes. Focusing on 132 US federal hydropower plants, in this study we evaluate the compounded impact of climate and reservoir-hydropower models’ structural uncertainties on monthly hydropower projections. In particular, instead of relying on one single regression-based hydropower model, we introduce another conceptual reservoir operations-hydropower model in the assessment framework. This multi-model assessment approach allows us to partition uncertainties associated with both climate and hydropower models for better clarity. Results suggest that while at least 70% of the uncertainties at the annual scale and 50% at the seasonal scale can be attributed to the choice of climate models, up to 50% of seasonal variability can be attributed to the choice of hydropower models, particularly in regions over the western US where the reservoir storage is substantial. The analysis identifies regions where multi-model assessments are needed and presents a novel approach to partition uncertainties in hydropower projections. Another outcome includes an updated evaluation of Coupled Model Intercomparison Project Phase 5 (CMIP5)-based federal hydropower projection, at the monthly scale and with a larger ensemble, which can provide a baseline for understanding future assessments based on CMIP6 and beyond.

54 ENVIRONMENTAL SCIENCES↗

Bat Smart Curtailment: Efficacy and Operational Testing

Curtailment, or blanket curtailment, is a leading method to mitigate the impacts to bats from operating wind turbines. Although this strategy results in considerable decreases in bat fatalities, it also results in decreased energy production. In 2019, Natural Power was awarded funding by the Department of Energy to assess the readiness of the informed smart curtailment technology, EchoSense (formerly referred to as Detection and Active Response Curtailment, [DARC]). The research undertaken by this project expands the understanding of alternative methods, known as smart curtailment, to maintain a reduction in bat fatalities while simultaneously recovering lost energy associated with blanket curtailment. The overall project was composed of three major tasks; Task 1 was focused on cybersecurity compliance of the EchoSense system in accordance with the North American Electric Reliability Corporation Critical Infrastructure Protection (“NERC CIP”) standards, Task 2 assessed the mechanical loads exerted on turbines when operating under a smart curtailment regime, and Task 3 assessed the efficacy of the EchoSense system at an operational wind farm. Regarding Task 1, an external review by the National Renewable Energy Laboratory determined that the EchoSense system did not create any new cybersecurity weaknesses and was compliant with the NERC CIP standards. As a result of this process, Natural Power developed some best practices (10.1) for wind- wildlife technology developers. In conjunction with the National Renewable Energy Laboratory, the results (10.2) of the loads testing demonstrated that the periodic curtailment and release of turbines by the EchoSense system did not have any detrimental impact on the mechanical components of a wind turbine (Task 2). During the late summer to fall of 2020 and 2021, Natural Power demonstrated that the use of the EchoSense smart curtailment system resulted in no significant difference in bat fatalities compared to blanket curtailment with cut-in speeds at 6.9 m/s (2020) and 5.0 m/s (2021) while resulting in a significant difference in decreased lost energy (Task 3). This translates to an average of 41% (2020) and 56% (2021) reduction in per turbine energy loss compared to blanket curtailment. The reduction in energy loss that would have been achieved by EchoSense curtailment compared to blanket curtailment, if applied across all 69 turbines, is roughly equivalent to having an additional turbine on site. These results are notable for finding a balance between the environmental impact of wind energy and the economic feasibility in energy production associated with mitigating that impact. https://www.naturalpower.com/us/expertise/service/engineering-operations/echosense

17 WIND ENERGY↗

The Technical, Economic, Risk, and Adoption Assessment for Evaluating Work Reduction Opportunities in the Nuclear Industry

Automation and cost-saving initiatives, such as process automation with advances in artificial intelligence, are gaining traction in modernization efforts across the nuclear industry. As these innovations are increasingly adopted, it becomes crucial to evaluate their impacts comprehensively. Various technical and economic attributes, along with risk and human readiness factors, must be achieved to ensure that innovative projects enabling automation and modernization are successful. However, no systematic or integrated framework exists that allows plants to evaluate these innovative projects. To address this gap, the Technical, Economic, Risk, and Adoption (TERA) assessment offers a structured method to evaluate innovative technologies, ensuring solutions meet both operational and safety standards. The TERA framework integrates the disparate perspectives to assess modernization opportunities in nuclear operations. It combines qualitative and quantitative models to evaluate the relationship between performance and business impacts, while also enabling continuous re-evaluation during project development. This approach helps plant owners identify high-priority opportunities, optimize cost savings, and minimize risks, ensuring projects remain on track to achieve desired returns. By providing a comprehensive, systematic methodology, TERA enables informed, data-driven decisions that support successful modernization efforts, enhancing efficiency, safety, and cost savings across nuclear operations. This paper explains the TERA framework and its benefits for the nuclear industry.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

An Assessment of the Materials of Construction for the Transfer Lines and Unit Operations Equipment Associated with the Recycle Diversion Process

The Defense Waste Processing Facility (DWPF) processes and vitrifies radioactive waste that it receives from the Concentration, Storage, and Transfer Facility (CSTF) and Salt Waste Processing Facility (SWPF). As a result of the evaporation of water during both the melter feed preparation and the melter feed vitrification steps in DWPF, a recycle waste stream is generated, neutralized, and sent back to the CSTF. The recycle waste is a dilute water stream originating from the collection of condensate liquids containing some minor sludge and frit solids and other waste components primarily resulting from entrainment into the condensate during foam-over events. The recycle stream volume is significant and is expected to approach 3 million gallons per year once the SWPF reaches full operation. Diverting the bulk of the recycle waste stream from the CSTF is essential for the eventual closure of the waste tanks, and hence the completion of the SRS liquid waste mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗