Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

On the dependence of the efficiency of a 240 GHz high-power gyrotron on the displacement of the electron beam and on the azimuthal index

Two issues in the cavity design for a Megawatt-class, 240 GHz gyrotron are addressed. Those are first, the effect of a misaligned electron beam on the gyrotron efficiency and second, a possible azimuthal instability of the gyrotron. The aforementioned effects are important for any gyrotron operation, but could be more critical in the operation of Megawatt-class gyrotrons at frequencies above 200 GHz, which will be the anticipated requirement of DEMO. The target is to provide some basic trends to be considered during the refinement and optimization of the design. Self-consistent calculations are the base for simulations wherever possible. However, in cases for which self-consistent models were not available, fixed-field results are presented. In those cases, the conservative nature of the results should be kept in mind.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LANSCE-R WIRE-SCANNER ANALOG FRONT-END ELECTRONICS

A new AFE is being developed for the new LANSCE-R wire-scanner systems. The new AFE is implemented in a National Instruments Compact RIO (cRIO) module installed a BiRa 4U BiRIO cRIO chassis specifically designed to accommodate the cRIO crate and all the wire-scanner interface, control and motor-drive electronics. A single AFE module provides interface to both X and Y wire sensors using true DC coupled transimpedance amplifiers providing collection of the wire charge signals, real-time wire integrity verification using the normal dataacquisition system, and wire bias of 0V to +/-50V. The AFE system is designed to accommodate comparatively long macropulses (>1ms) with high PRF (>120Hz) without the need to provide timing signals. The basic AFE bandwidth is flat from true DC to 50kHz with a true first-order pole at 50kHz. Numeric integration in the cRIO FPGA provides real-time pulse-to-pulse numeric integration of the AFE signal to compute the total charge collected in each macropulse. This method of charge collection eliminates the need to provide synchronization signals to the wire-scanner AFE while providing the capability to accurately record the charge from long macropulses at high PRF.

Accelerator Design, Technology, and Operations↗

Noise limits for dc SQUID readout of high- Q resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.

Bosons↗

Single-Shot Readout Performance of Two Heterojunction-Bipolar-Transistor Amplification Circuits at Millikelvin Temperatures

High-fidelity single-shot readout of spin qubits requires distinguishing states much faster than the T 1 time of the spin state. One approach to improving readout fidelity and bandwidth (BW) is cryogenic amplification, where the signal from the qubit is amplified before noise sources are introduced and room-temperature amplifiers can operate at lower gain and higher BW. We compare the performance of two cryogenic amplification circuits: a current-biased heterojunction bipolar transistor circuit (CB-HBT), and an AC-coupled HBT circuit (AC-HBT). Both circuits are mounted on the mixing-chamber stage of a dilution refrigerator and are connected to silicon metal oxide semiconductor (Si-MOS) quantum dot devices on a printed circuit board (PCB). The power dissipated by the CB-HBT ranges from 0.1 to 1 μW whereas the power of the AC-HBT ranges from 1 to 20 μW. Referred to the input, the noise spectral density is low for both circuits, in the 15 to 30 fA/√Hz range. The charge sensitivity for the CB-HBT and AC-HBT is 330 μe/√Hz and 400 μe/√Hz, respectively. For the single-shot readout performed, less than 10 its is required for both circuits to achieve bit error rates below 10-3, which is a putative threshold for quantum error correction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Repetitively pulsed regime of Nd : glass large-aperture laser amplifiers

A repetitively pulsed operation regime of neodymium glass rod laser amplifiers with apertures of 4.5, 6, 8.5, and 10 cm is analysed using experimental data. The limits of an increase in the pulse repetition rates are determined. Universal dependences are obtained, which help finding a compromise between increasing the repetition rate and enhancing the gain for each particular case. In particular, it is shown that an amplifier 4.5-cm in diameter exhibits a five-fold safety factor with respect to a thermo-mechanical breakdown at a repetition rate of 1 pulse min{sup -1} and stored energy of above 100 J. A strong thermally induced birefringence in two such amplifiers is experimentally reduced to a 'cold' level by employing a 90 Degree-Sign optical rotator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generating Optical Orbital Angular Momentum in a High-Gain Free-Electron Laser at the First Harmonic

A scheme to generate intense coherent light that carries orbital angular momentum (OAM) at the fundamental wavelength of an x-ray free-electron laser (FEL) is described. The OAM light is emitted as the dominant mode of the system until saturation provided that the helical microbunching imposed on the electron beam is larger than the shot-noise bunching that leads to self-amplified emission. Operating at the fundamental, this scheme is more efficient than alternate schemes that rely on harmonic emission, and can be applied to x-ray FELs without using external optical mode conversion elements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent Transfer of Spin Angular Momentum by Evanescent Spin Waves within Antiferromagnetic NiO

Insulating antiferromagnets are efficient and robust conductors of spin current. To realise the full potential of these materials within spintronics, the outstanding challenges are to demonstrate scalability down to nanometric lengthscales and the transmission of coherent spin currents. Here, we report the coherent transfer of spin angular momentum by excitation of evanescent spin waves of GHz frequency within antiferromagnetic NiO at room temperature. Using element-specific and phase-resolved x-ray ferromagnetic resonance, we probe the injection and transmission of ac spin current, and demonstrate that insertion of a few nanometre thick epitaxial NiO(001) layer between a ferromagnet and non-magnet can even enhance the flow of spin current. Our results pave the way towards coherent control of the phase and amplitude of spin currents at the nanoscale, and enable the realization of spin-logic devices and spin current amplifiers that operate at GHz and THz frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Etching sharp tips from thin metallic wires for tuning-fork-based scanning probe microscopy

Sharp tips are critical for obtaining high resolution images in scanning probe microscopy (SPM), particularly in samples with large variations in topography. For tuning-fork-based SPM, such tips are commonly obtained by electrochemical etching of metallic wires (e.g., tungsten). Electrochemical etching of metallic wires is the preferred means of preparing tips for scanning tunneling microscopy (STM), and techniques for obtaining sharp tips have been investigated extensively. However, the requirements for STM and tuning-fork-based SPM are different. In particular, the wires used in STM are typically 250-500 μ m in diameter, while the wires used for tuning-fork-based SPM are usually an order of magnitude narrower in order to minimize loading of the tuning fork: 25-50 μ m and sometimes down to a few micrometers in diameter. Consequently, many of the recipes developed for etching thicker metallic wires for STM tips do not give optimal results for smaller diameter wires. The authors describe here a modification of the etching circuit of Ibe et al . that significantly improves the reproducibility and reliability of the etching process for thin wires, and discuss the parameters that affect the aspect ratio of produced tips.

42 ENGINEERING↗

Analysis of pump-to-signal noise transfer in two-stage ultra-broadband optical parametric chirped-pulse amplification

In optical parametric chirped-pulse amplification (OPCPA), pump temporal intensity modulation is transferred to the chirped-signal spectrum via instantaneous parametric gain and results in contrast degradation of the recompressed signal. We investigate, for the first time to our knowledge, the pump-to-signal noise transfer in a two-stage ultra-broadband OPCPA pumped by a single laser and show the dependence of pump-induced signal noise, characterized both before and after pulse compression, on the difference in pump-seed delay in the two stages. We demonstrate an up-to-15-dB reduction of the pump-induced contrast degradation via pump-seed delay optimization. Experiments and simulations show that, even when parametric amplifiers are operated in saturation, the pump-seed delay can be used to minimize the pump-induced contrast degradation that is attributed largely to the noises from the unsaturated edges of the pulse and that of the beam.

47 OTHER INSTRUMENTATION↗

STREAK CAMERA MEASUREMENTS OF THE APS PC GUN DRIVE LASER

We report recent pulse-duration measurements of the APS PC Gun drive laser at both second harmonic and fourth harmonic wavelengths. The drive laser is a Nd:Glass-based chirped pulsed amplifier (CPA) operating at an IR wavelength of 1053 nm, twice frequency-doubled to obtain UV output for the gun. A Hamamatsu C5680 streak camera and an M5675 synchroscan unit are used for these measurements; the synchroscan unit is tuned to 119 MHz, the 24th subharmonic of the linac s-band operating frequency. Calibration is accomplished both electronically and optically. Electronic calibration utilizes a programmable delay line in the 119 MHz rf path. The optical delay uses an etalon with known spacing between reflecting surfaces and is coated for the visible, SH wavelength. IR pulse duration is monitored with an autocorrelator. Fitting the streak camera image projected profiles with Gaussians, UV rms pulse durations are found to vary from 2.1 ps to 3.5 ps as the IR varies from 2.2 ps to 5.2 ps.

LASER↗

A Prototype Wire Position Monitoring System

The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1{micro}m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1{micro}m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

43 PARTICLE ACCELERATORS↗

Modeling of a Compact Terahertz Source based on the Two-Stream Instability

THz radiation straddles the microwave and infrared bands of the electromagnetic spectrum, thus combining the penetrating power of lower-frequency waves and imaging capabilities of higher-energy infrared radiation. THz radiation is employed in various elds such as cancer research, biology, agriculture, homeland security, and environmental monitoring. Conventional vacuum electronic sources of THz radiation (e.g., fast- and slow-wave devices) either require very small structures or are bulky and expensive to operate. Optical sources necessitate cryogenic cooling and are presently capable of producing milliwatt levels of power at THz frequencies. We propose a millimeter and sub-millimeter wave source based on a well-known phenomenon called the two-stream instability. The two-beam source relies on lowenergy and low-current electron beams for operation. Also, it is compact, simple in design, and does not contain expensive parts that require complex machining and precise alignment. In this dissertation, we perform 2-D particle-in-cell (PIC) simulations of the interaction region of the two-beam source. The interaction region consists of a beam pipe of radius ra and two electron beams of radius rb co-propagating and interacting inside the pipe. The simulations involve the interaction of unmodulated (no initial energy modulation) and modulated (energy-modulated, seeded at a given frequency) electron beams. In addition, both cold (monoenergetic) and warm (Gaussian) beams are treated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exclusive-or logic circuit has useful properties

Single, simple exclusive-or logic connective eliminates excessive hardware and the number of interconnections between logic modules. This circuit performs the necessary switching for the exclusive-or operation and amplifies, restores, and inverts the signal.

Batte, W. G.↗

Amplification of microwaves by superconducting microbridges in a four-wave parametric mode

Parametric amplification of microwaves was observed using thin-film junctions of the Anderson-Dayem type. A series of 80 such junctions were incorporated into the upper conductor of a broadband 50-ohm microstrip transmission line with no DC bias. The amplifier was operated in the 'doubly degenerate' mode with signal, pump, and idler frequencies closely and equally spaced. An electronic gain of 12 dB at 10 GHz was observed. The bandwidth was measured to be 1 GHz and the noise temperature to be less than 20 K.

Parrish, P. T.↗

Satellite power system (SPS) magnetron tube assessment study

Taks performed to extend the data base and to define a technology development program for the magnetron directional amplifier for the SPS are reviewed. These include: (1) demonstrating the tracking of phase and amplitude of the microwave output to phase and amplitude references; (2) expanding the range of power over which the directional amplifier will operate; (3)recognizing the importance of amplitude control in overall system design and in simplifying power conditioning; (4) developing a preliminary design for the overall architecture of the power module; (5) demonstrating magnetron starting using the amplitude control system; (6) mathematically modelling and performing a computerized study of the pyrolytic graphite radiating fin; (7) defining the mass of the magnetic circuit for the SPS tube; (8) noise measurement; (9) achieving harmonic suppression by notch reflection filters; (10) estimating the mass of the transmitting antenna; (11) developing a magnetron package with power generation, phase control, and power condition functions; and (12) projecting magnetron package characteristics.

Source record↗